Home
        SPT SF-613 Use and Care Manual
         Contents
1.                                                           D  SELECTION OF FUNCTIONS    1     ON OFF  Turns unit ON or OFF   e Press once to turn ON  Following indicator lights will illuminate  POWER   IONIZER  and SPEED  Unit operates in default High fan speed  LCD  panel will display rotating fan at High speed    e Press again to turn OFF    e IONIZER turns on automatically when unit is powered on    FLOW  Horizontal swing of vertical louvers    e Press once to engage auto swing of louvers  FLOW indicator light will  illuminate and LCD panel will display auto swing indicator    e Press again for fixed air direction    e 10 directing vertical airflow  adjust the horizontal louvers manually    Speed  Selects fan speed    e Press to select desired fan speed  High     Medium     Low  in turn  LCD  panel will display the corresponding air speed    Sleep  Unit operates according to preset computer program  alternating   between different fan speeds    e Press to engage in Sleep Mode  SLEEP indicator will illuminate and LCD  panel displays the sleep  moon  indicator    e To return to regular fan mode  press either SLEEP or SPEED button    Cool  For cool air   humidify function    e Press once to start the evaporative cooling function  COOL indicator light  will illuminate and LCD panel displays the cool  snowflake  indicator    e Press again to stop function and operate in regular fan mode    e Make sure water is added before turning on this function  Unit cycles the  water to blow
2.       Instruction Manual    Evaporative Swamp Cooler                                                                                              It is important that you read these  instructions thoroughly before using  your new air cooler and we strongly  recommend that you keep them in a  safe place for future reference     Model No  SF 613    CONTENTS    TABLE OF CONTENTS                                                      1  A  PRODUCT INTRODUCTION                                         2  B  TECHNICAL PARAMETER                                           2    C  CONTROL PANEL  LCD  amp  CONSTRUCTION DIAGRAM    3    D  SELECTION OF FUNCTIONS                                  4 5  E  CARE AND MAINTENANCE                                         5  F  CAUTIONS                                                                6  G  PACKING LIST                                                           8  DEFECTIVE NOTICE                                                   8  WARRANTY                                                               9    A  PRODUCT INTRODUCTION    SF 613 Air cooler is our latest design with microcomputer control system  It has  device for storing water and ice cubes  It can lower surrounding temperature  freshen  the air with equipped anion  humidify the air through the principle of water  evaporation and melting ice  LCD panel makes it luxurious and easy to use  Also  equipped with double layered  filtration mesh water curtain to remove odor and dust 
3.     This unit will provide you a comfortable and healthy environment     BRIEF INTRODUCTION OF FEATURES    Remote control     0 5 to 7 5 hours timer control    3 fan speeds  High     Medium     Low   Water tank for cooler air output   Activated carbon removes odor     O 8     08     GO              w    TECHNICAL PARAMETER    High grade computer control system with LCD panels     Functions include  cool fan  humidifier  air filtration  and ionizer   Energy saving and effective  input power of cooler is 60W     Filter to remove harmful tiny substances  such as dust and pollen        Main technical parameter                      Rating voltage frequency 120V   60Hz  Input power 60W  Water consumption 0 5 0 6L h  Max air volume  gt 20m8 min  Fan Speeds 7 4 m s  N  W  19 9 lbs          Dimension  L x W x H        14 5 x 11 5 x 31 75 in           CONTROL PANEL  LCD DISPLAY AND CONSTRUCTION DIAGRAM    1  Control panel and functions  Same with remote controller     CONTROL PANEL       LCD DISPLAY    Sleep Mode Indicator Timer Indicator       ot T  i            fol  U  USU  10      bagil 7    off TTI  N 2        7    o Ww              fol                                                                      Fan Speed Indicator Auto Swing Indicator       Cool Indicator    2  Construction diagram     Control buttons       LCD  Outlet of      air flow  Filter    Handle of  front door    Water level window                                                       Caster                       
4.   3  Clean under lukewarm water and mild detergent    4  Make sure filter is completely dry before operating unit     Cleaning the Water Curtain   1  Disconnect the power supply    2  Remove the 3 screws located on the back frame  one in each top corner and  one at bottom center  Do not remove back panel yet    3  Panel is connected to the unit by a water tube  gently remove end of tube  that is connected to the water pump   Fig  3  Remove back panel    4  Remove water curtain by first removing the bottom rod     push in gently   Then remove from top rod by separating the Velcro attachment    5  Wash water curtain in a mild detergent and warm water solution  then rinse   in clean water   Fig  4    Replace water curtain  make sure tube is firmly connected to the pump     D    Storage   If you plan not to use the unit for a long period of time  drain the water tank and  wipe clean  Clean the filter and water curtain  Operate the unit in normal fan  mode for approximately 30 60 minutes on a sunny day  This will dry the interior  and prevent mold from growing  It is recommended to pack the unit in its original  box and store in a dry  cool place    F  CAUTIONS        Fig  5   Fig  6   Fig  7   1  Use normal supply of 120V   60Hz  Plug into dedicated socket with minimum  rating current of 3A     10     Unplug power source when not in use   12   13   14     11    15   16     After filling with water  do not tilt unit and avoid moving unit     which may  cause water to overflow the 
5.  cool  humidified air    e Add ice to the water tank for added cooling    Timer  Sets timer off in increment of 0 5 hours    e Timer can be set between 0 5 to 7 5 hours    e TIMER indicator will illuminate and LCD panel will display the set time    e To remove timer and operate unit continuously  press button repeatedly  until indicator light and display goes off    Oxygen Bar with Negative ion    e Fan releases negative ions into the air    e Operates automatically when unit is turned on     NOTE  Water must be added to the water tank before using the COOL function     Open the front door by the pulling gently on the handle    Add water to the tank  Do not overfill    For added cooling  add ice to the tank   Fig  1    Power supply should be disconnected before filling to prevent electrical parts  from damage        Fig 1    E  CARE AND MAINTENANCE  Always power OFF and unplug the unit before cleaning and maintenance     Clean the housing with a damp cloth  Never spray water directly onto the  housing or control panel LCD or use harsh chemicals    After long time operation  the Filter and Water Curtain becomes clogged with  dust and dirt  which will greatly affect the unit   s performance  Sometimes  mold and mildew may also occur  due to lack of water changes  It is  recommended to clean the filter and water curtain once every two weeks        Cleaning the Dust Filter   1  Disconnect the power supply    2  Push down on the two handles of the filter and pull outwards   Fig 2 
6. cations to the product     Improper installation or failure to perform the necessary maintenance     This GUARANTEE is in addition to your Statutory Rights    
7. on an  empty tank  as this may cause water pump to malfunction                              PACKING LIST  No  NAME QUANTITY  1 Air Cooler 1  2 Remote Controller 1  3 Instructions Manual 1                   DEFECTIVE NOTICE  If this product is defective or not working properly  Please DO NOT return to your retail store    Please contact us directly with any Service or Technical Assistance  Contact us toll free at   1 800 330 0388          SPT    Your Guarantee    If this product is found to be faulty as a result of faulty materials or workmanship    within one year from date of purchase  it will be repaired free of charge     This guarantee is subject to the following terms     Sunpentown must be notified of the fault    Proof of purchase must be presented to Sunpentown   s nominated  representative    The warranty will be void if the product if modified  misused or repaired by an  unauthorized person    The warranty after repair will not be extended beyond the original one year  period    All replacement parts will be new or reconditioned    Parts  which are replaced  become the property of Sunpentown    The warranty applies for the use of the product in the USA only     What is NOT COVERED     Warranty does not include freight charges    Incidental or consequential damage caused by possible defects with this  product    Damage to product caused by improper power supply voltage  accident  fire   floods or acts of nature    Failure of product resulting from unauthorized modifi
8. sides of the tank and leak  If unit needs to be  moved a little  push on the side gently   Fig  5    Never turn the unit on its sides   Fig  6    Do not place any heavy objects on top of the Air Cooler  The air outlet must  not be obstructed   Fig  7           Fig  8 Fig 9 Fig  10 Fig 11  Keep a minimum space of 6 inches around the unit   Fig  8   Suitable ambient temperature range is 68 104F  The body of this Air Cooler  should not be placed in area with extremely high or low temperature  When    ambient temperature is high  change water frequently to prevent mildew and  mold growth   Fig  9    Never wet the unit or spray water onto the control panel or LCD   Fig  10    Do not use any corrosive cleaner or solvent   Fig  11    If using unit as a humidifier during cold weathers  below 32f   be sure to  empty and dry up the water tank after use to prevent water freezing  After  emptying water from the drain  use a towel to suck up remaining water   Empty the water tank before moving the Air Cooler     Do not use the COOL function if unit is used in a damp and closed space   Do not place fingers or insert foreign objects into the louver during operation   Do not operate unit with a damage power cord or plug  Contact Sunpentown   do not attempt to repair on your own    Basic precautions should be taken when operating unit near young children   When operating in COOL mode  pay attention to water level and add water  when water level is less than 1 3 full  Do not operate COOL mode 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
AC15CC1CC1X_OM_EFGSJ1  MANUAL DE INSTALAÇÃO, CONFIGURAÇÃO E USO  Central de compresores de 5 etapas + 2 salidas de variador    オフィスシュレッダー  2 - Panasonic  SUPER MICRO Computer 5015A-EHF Security Camera User Manual  IM 21445 - Norauto  SEG Boombox BB 1210 (bl)  Smeg FA162MX User's Manual    Copyright © All rights reserved. 