Home

American Standard 4508.201.295 Installation Guide

image

Contents

1. If spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 g PA care INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M968843 Rev 1 3 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If ah does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise
2. or 3 8 0 D BULL NOSE RISERS 3 E Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length E Connect 1 1 4 O D tailpiece on POP UP DRAIN to 1 2 PIPE ZA waste outlet THREAD FLEXIBLE SUPPLIES 3 8 O D BULL NOSE RISERS 3 8 COMPRESSION CONNECTION COMPRESSION NUT M968843 Rev 1 3 1 0 TEST INSTALLED FITTING With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks Remove AERATOR 3 Replace AERATOR 3 CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions KY q vara el Release POP UP KNOB 4 down and check all drain connections and P trap for leaks m Tighten if necessary A TAZ Ss i lee OUTLET 7 W P TRAP pE service To change direction of handle rotation proceed as follows Turn VALVE in OFF position Loosen HANDLE SCREW 1 Pull HANDLE 2 off ADAPTER 3 Loosen ADAPTER SCREW 4 and pull off ADAPTER 3 Turn ADAPTER 3 90 in a way that flat in ADAPTER 3 catches the other flat on VALVE STEM 5 Reinstall ADAPTER SCREW 4 and LEVER HANDLE 2 Tighten HANDLE SCREW 1
3. American Standard Installation Instructions PRINCETON 4508 201 Centerset Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Speed Connect Drain Certified to comply with ANSI A112 18 1 e Fewer parts installs in less time M968843 Rev 1 3 e Never needs adjustment e Guaranteed to seal properly the first time every time To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Required tools J CT NE p ri ba Screwdriver Channel Locks Adjustable Wrench Tubing Cutter main supply Turn off hot and cold water supplies before beginning Note Putty is not required unless mounting surface is uneven Apply a bead of PUTTY along the edge of the underside of the BODY 1 if required Insert FAUCET 4 and CABLE CONNECTOR 2 through mounting holes of Sink or mounting surface Fig A Assemble LOCKNUTS 3 onto SHANKS 4 from under side of Sink Hand tighten firmly Fig B HAND TIGHTEN SINK OR MOUNTING SURFACE 2 POP UP DRAIN Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B Le A N fka W 3 REMOVE FLANGE Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 from dra
4. f the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof in Locked mode and not be removable Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J yj Loop toward FRONT OF SINK Re install the Cam Cap making sure the guide teeth are facing Cor outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Unlocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP M968843 Rev 1 3
5. in body Fig A Thread LOCKNUT 3 clock wise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE From under side of SINK AU Vy Tighten LOCKNUT 1 firmly with Adjustable install DRAIN BODY 1 up Se Wrench or Channel Locks through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly FLANGE GASKET AND POP UP KNOB Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A POP UP KNOB 1 must be fully down Fig B WHITE FOAM GASKET NOT VISIBLE M968843 Rev 1 3 F ATTACH CABLE CONNECTOR m Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 O D Fig B 8 CHECK OPERATION OF POP UP E Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 9 MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS MUST BE PURCHASED SEPARATELY m Connect water supply to FAUCET 1 with 1 2 IPS FLEXIBLE SUPPLIES 2
6. onto the Drain Body Connection 2 and hand tighten Fig A STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F Mo tam REMOVE CAM CAP M968843 Rev 1 3 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J LOOP TOWARD REAR OF SINK Re install the Cam Cap making sure the guide teeth are facing Cor outward I

Download Pdf Manuals

image

Related Search

Related Contents

Rapport annuel 2011-2012  Televisor a color guía del usuario Para el modelo:  PDF downloaden - SFM  Technika LCD22-921 Flat Panel Television User Manual  DDF459 - Kieskeurig  Betriebsanleitung WS200-UMB WS300-UMB WS400  pnevmatski čepi pneumatic pipe plugs pneumatische  formulaciones numéricas para el cálculo, diseño y evaluación de la  

Copyright © All rights reserved.
Failed to retrieve file