Home
        AireRyder FN56308AW Instructions / Assembly
         Contents
1.  IMPORTANT   BEFORE YOU BEGIN INSTALLING THE FAN  CAREFULLY READ ALL INFORMATION ON THE SEPARATE  SHEET  SAFETY INSTRUCTIONS  AS WELL AS THE FOLLOWING  INSTALLATION INSTRUCTIONS   IF IN    DOUBT  CONSULT A QUALIFIED ELECTRICIAN   THIS FAN MUST BE INSTALLED WITH A WALL CONTROL SWITCH   SAVE ALL INSTRUCTIONS        NOTE  The fan weight is 21 Ib  9 5 kg   Be sure the outlet box you are using is securely attached to the building structure  and can support the full weight of the fan  Failure to do so can result in serious injury     Installation Steps         Tighten the hanger bracket to the outlet  box with 2 mounting screws   To reduce  the risk of fire electric shock  or personal    Outlet Box injury  mount to the outlet box marked  rare  Acceptable for fan support  and use  Baka SS at screws provided with the outlet   OX        Turn OFF the electric power at the  main fuse or circuit breaker box     Downrod    Canopy    Lock 7       Remove the Lock Pin and take off Thread the motor wires through the Insert the Downrod into the Collar   the Hanger Pin  canopy  downrod stand cover and Slide Hanger Pin through holes of  downrod  Collar and Downrod     Hanger Bracket       Insert and tighten the two Collar Hang the fan on hanger bracket     Screws  Slide Lock Pin into Hanger and make sure the slot of hanger  Pin until it locks into position  ball is snapped into the chip of    hanger bracket exactly    Note  For slope ceiling installation   make sure the slot of hanger ball  and 
2. aireRyder   LIMITED LIFETIME WARRANTY    Model No   FN56308    aireRyder ORIGINAL CEILING FAN LIMITED LIFETIME WARRANTY    The limited lifetime warranty covers this ceiling fan  for residential use by the original purchaser  against defects in  material or workmanship as follows     If your aireRyder Ceiling Fan motor fails at any time during the lifetime of the original purchaser due to defects in  material or workmanship  we will provide a replacement part free of charge     If your Fan motor fails at any time within one year after the original date of sale to the original purchaser due to defects  in material or workmanship  we will provide labor to repair the defect  with the exception of take down reinstallation   free of charge  The original purchaser will be responsible for all labor costs after this one year period     If no replacement parts are provided for any part of your Fan motor that fails at any time during your lifetime due to  defects in material or workmanship  we will refund the original purchase price of your Fan     If your Fan blades  pull chain switch  reverse switch  or any accessory  except glass globes and light bulbs  fails at any  time within one year after the original date of purchase due to a defect in material and workmanship  we will repair or  if  we choose  replace the defective blades  switch  or accessory free of charge  with the exception of take  down reinstallation services     If the original purchaser ceases to own the Fan  this warr
3. anty and any implied warranty  including but not limited to any  implied warranty of merchantability or fitness for a particular purpose  become void  This warranty and any implied  warranty  including but not limited to any implied warranty of merchantability or fitness for a particular purpose  do not  cover glass globes  light bulbs  or finish on any metal portions of the Fan     This warranty is in lieu of express warranties  The duration of any implied warranty of merchantability or fitness for a  particular purpose  with respect to any aireRyder Ceiling Fan motor  blades  switch  or accessories  is expressly  limited to the period of the express warranty set forth above for such motor  blades  switch  or accessories     This warranty excludes defects  malfunctions  or failures of any aireRyder Ceiling Fan that are caused by repairs by  persons not authorized by us  use of parts or accessories not authorized by us  mishandling  improper installation   modifications or damage to the Fan while in your possession  or unreasonable use  including failure to provide  necessary maintenance     In no event shall aireRyder Fan be liable for consequential or incidental damages     Some states do not allow the exclusion or limitation of consequential or incidental damages  in which case the above  limitation or exclusion may not apply     This warranty gives you specific legal rights and you may also have other rights which vary from state to state        aireRyder        Package C
4. eable  interchanging two adjacent  side by side   blades can redistribute the weight and possibly result in smoother operation     1  Check blue wire from fan to make sure it is connected to hot wire from house   2  Check for loose or disconnected wires in fan switch housing   3  Check for loose or disconnected wires in light kit   4  Check for faulty light bulbs   CAUTION  Make sure main power is turned off before entering switch housing     aireRyder      PAGE  4 4 070414    
5. en screws against rubber band    5  Some fan motors are sensitive to signals from Solid State variable speed  controls  DO NOT USE a Solid State variable speed control    6  Allow  break in  period of 24 hours  Most noises associated with a new fan will  disappear after this period     All blades are weighed and grouped by weight  Natural woods vary in density  which could cause the fan to wobble even though all blades are weight matched   The following procedures should eliminate most of the wobble  Check for wobble  after each step    1  Check that all blades are screwed firmly into blade holders    2  Check that all blade holders are tightened securely to motor    3  Make sure that canopy and mounting bracket are tightened securely to ceiling  junction box and junction box is mounted firmly to ceiling joist    4  Most fan wobble problems are caused when blade levels are unequal  Check  this level by selecting a point on the ceiling above the tip of one of the blades   Keeping measure within 1 8 in  rotate the fan until the next blade is positioned  for measurement  repeat for each blade  If all blade levels are not equal  you  can adjust blade levels by the following procedure  To adjust a blade tip down   insert a washer  not supplied  between the blade and blade holder at the screw  closest to the motor  To adjust a blade tip up  insert washer  not supplied   between the blade and blade holder at the two screws farthest from the motor    5  If blade wobble is still notic
6. ontact separation of at least 3 mm in all poles  that  means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules    e NOTE  The safeguards provided by these safety instructions and by the separate installation  instructions are not meant to cover all possible conditions and situations that may occur  It must be  understood that common sense  caution and care are factors which can not be built into this product   These factors must be supplied by the person s  installing  caring for and operating the fan     WARNING  e TO AVOID RISK OF ELECTRIC SHOCK  BE SURE TO SHUT OFF POWER AT THE MAIN  FUSE OR CIRCUIT BREAKER BOX BEFORE INSTALLING OR SERVICING THIS  FIXTURE  TURNING OFF THE ELECTRICAL POWER BY USING THE LIGHT SWITCH  IS NOT SUFFICIENT TO PREVENT ELECTRICAL SHOCK   e TO REDUCE THE RISK OF INJURY  INSTALL THE FAN SO THAT THE BLADES ARE  AT LEAST 7 FEET  2 1 METERS  ABOVE THE FLOOR AND AT LEAST 18 INCHES     0 5 METERS  FROM THE TIP OF THE BLADES TO THE WALL    e TO REDUCE THE RISK OF FIRE  ELECTRIC SHOCK  OR PERSONAL INJURY  MOUNT  TO OUTLET BOX MARKED  ACCEPTABLE FOR FAN SUPPORT  AND USE MOUNTING  SCREWS PROVIDED WITH THE OUTLET BOX    e THE INSTALLATION HAS TO BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL  CODE  ANSI NFPA 70 1999 AND LOCAL CODES  IF YOU ARE UNFAMILAR WITH THE  METHODS OF INSTALLING ELECTRICAL WIRING  SEEK THE SERVICES OF A    QUALIFIED LICENSED ELECTRICIAN        aireRyder    070414    INSTALLATION INSTRUCTIONS   
7. ontents        Unpack your fan and check the contents  You should have the following items   1   Hanger Bracket   2   Canopy   3   Downrod Stand Cover   4   Downrod Set Included Hanger Ball 6 in Downrod Hanger Pin  amp  Lock Pin   5   Fan Fixture Set   6   Blade Holder  X5    7   Fan Blade X5    8   Decorations Slice X5    9   Switch Box   10   Assembly Kit   11  Remote Controller  Receiver  amp  Tramsmitter     Dimension Reference  Installed with 6 in  Downrod         A  19in  B 17 in  C 2 3 4in  D 13 in  E  5 1 8 in     aireRyder    070414    Exploded View Detail    Blade Holder MES   LS Fl  OR       A    Blade    amg  C      Hanger Bracket  Receiver    Canopy       Hanger Ball       Downrod       Downrod Stand Cover    Lock Pin          Collar          Housing       aireRyder     070414    Safety Instructions    READ ALL SAFETY INFORMATION AND INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN  INSTALLING THE FAN  SAVE INSTRUCTIONS     e   ll set screws of the fan must be checked and retightened where necessary before installation    e To reduce the risk of personal injury  do not bend the blade brackets when installing the brackets   balancing the blades or cleaning fan  Do not insert foreign objects in between rotating fan blades    e Before changing the fan direction  turn off the fan and wait for the fan blades to stop completely    e  f a stationary appliance is not provided with a supply cord and a plug  or with other means for  disconnection from the mains supply having a c
8. re nut     OR SPLICE 0 l Lao Bal Make sure all of wire nuts are connected firmly              xxx Tuck all wire nuts and wires carefully up into the Outlet Box   EXCEPT antenna  which should remain outside Outlet Box           Secure the canopy to hanger bracket Tighten blades to blade holders by  with screws  using blade screws and washers     aireRyder      PAGE  2 4 070414                                           Plastic Insert i Blade Holder          i Motor Screw C eee  Secure blade holders to the motor with Connect the two terminals respectively Assembly without fan light  motor screws and washers  from the motor and the switch box  Make sure the lead wire of fan light      in switch box is sealed with a wire  Daa akat hade z nut exactly  Secure the switch box  remove the plastic hede cover with the switch box screws   Turn ON the electric power at the Install the battery to the transmitter  9V  not included      main fuse or circuit breaker box    Press  HI  to turn on the fan at high speed     Press  MED  button to turn the fan in medium speed     Press  LOW  button to turn the fan in low speed     Press  OFF  button to turn off the fan     Press  LIGHT  button to turn on off the fan light  and press and  hold the  LIGHT  button to adjust the illumination of light     aireRyder       070414  PAGE  3 4    Trouble Shooting Guide    If you have difficulty operating your new ceiling fan  it may be the result of incorrect assembly  installation  or wiring  In some cases  
9. the chip of hanger bracket is  face down     aireRyder    PAGE  1 4 070414    Receiver Antenna    There is a code switch respectively in   the transmitter and receiver  This  DIP  Switch  is a 4 key unit  Fig 9   All keys   were set at  ON  position in the beginning   Set the keys to a different code  Make sure  the same numbered keys are switched  ON   for both DIP Switches  Fig 9a   Take note  that the  ON  position may have different  orientation in each        Code example   1 ON 2 OFF 3 ON 4 OFF  on both DIP Switches        Move Ground Wires  a   Outlet Box wires  b   and  Motor Wires  c  away from the center of the Hanger  Bracket  Then slide Receiver through Hanger  Bracket as shown  Antenna end first  until it is  centered  Finally  cut Motor Wires  c  to length  needed for connections     Hanger Bracket    Make wire connections   1  The Motor white wire to the white  To Motor N  wire from  Receiver with a wire nut   2  The Motor black wire to the black  To Motor L  wire from  Receiver with a wire nut   3  The Motor blue wire to the blue  For Light  wire from Receiver  with a wire nut   4  The white wire from Outlet Box to the red  AC in N  wire  i Hanger from Receiver with a wire nut   CO N Bracket 5  The red wire from Outlet Box to the red  AC in L  wire from  J Receiver with a wire nut   FA 6  The ground wire from Outlet Box to the green ground wire  Antenna       BA from the Hanger Ball and the green ground wire from the  DO NOT CUT Hanger Hanger Bracket with a wi
10. these installation errors may be mistaken for defects  If you experience any faults    please check this Trouble Shooting Guide  If a problem cannot be remedied or you are experiencing difficulty  in installation  please call our Customer Service Department     TROUBLE    1  If fan does not start     2  If fan sounds noisy     3  If fan wobbles     4  If light does not work     SUGGESTED REMEDY    1  Check main and branch circuit fuses or circuit breakers    2  Check line wire connections to fan and switch wire connections in switch  housing   CAUTION  Make sure main power is turned off    3  Make sure forward reverse switch is firmly in up or down position  Fan will not  operate when switch is in the middle    4  Make sure that the wall controler is turned  ON      1  Make sure all screws in motor housing are snug   not over tightened    2  Make sure the screws which attach the fan bladeholder to the motor are tight    3  Make sure wire nut connectors in switch housing are not rattling against each  other or against the interior wall of the switch housing   CAUTION  Make sure main power is turned off before entering switch housing    4  If using an optional ceiling fan light kit  check to be sure the screws securing  the glassware are finger tight  Check to be sure light bulb is tight in socket and  not touching glass shade s   If vibration persists from glass  remove glass and  install a 1 4 in  wide rubber band on glass neck to act as an insulator  Replace  glass and tight
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Manuel d`utilisation du J  Massive Ceiling light 30096/43/10  Crucial Lexar 16GB JumpDrive TwistTurn  Residential Estimator Program Getting Started  MANUEL DE PROPRIETAIRE ET D`UTILISATION  4面 - 東京消防庁  f. mode d`emploi 20w rechargeable led flood light xflr-0    Copyright © All rights reserved. 
   Failed to retrieve file