Home

Sea Gull Lighting 5104-07 Installation Guide

image

Contents

1. WHITE HOUSE WIRE HOUSE WIRE BLACK WHITE o J PARALLEL WIRE ROUND amp SMOOTH PARALLEL WIRE SQUARE amp RIDGED WHITE OR GREY WITH TRACER WHITE OR GREY WITHOUT TRACER CO OOOO BROWN GOLD OR BLACK WITH TRACER c wa a en BROWN GOLD OR BLACK WITHOUT TRACER Note When parallel wire is used the tracer wire is square shaped or ridged and less tracer wire is round in shape or smooth Seen best when viewed from wire end To separate wires grasp the ends of each wire and pull apart B Take your fixture wire s from group A and place evenly against the black wire from the outlet box DO NOT twist wires together before using wire connectors C Fit a wire connector not supplied over the wires and screw the connector clockwise until you feel a firmness D Try gently to pull the connector off the wires If you can pull the connector off carefully re do steps B and C as above and check again for a firm connection E Connect the fixture wire from group B to the white wire from the outlet box in the same manner STEP 6 GROUNDING INSTRUCTIONS The green grounding screw D is to be inserted into the hole with two raised dimples provided on the mounting bar A Wrap the ground wire F from the fixture if supplied and the ground wire from the outlet box bare metal or green insulated wire around the green grounding screw D on the mounting bar A if uninsulated wire is on the mounting bar A connect
2. the ground wire F from the fixture if supplied and the outlet box to it using a small wire connector not supplied NOTE Underwriters Laboratories U L does not require all fixtures to have ground wires These fixtures still meet all U L specifications The listing mark of Underwriters on the product identifies products manu factured under its listing and Follow Up Service Programs NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER SUPPLY WIRES FINAL ASSEMBLY Make sure no bare wires can be seen outside wire connectors STEP 1 After wires are connected tuck them carefully inside outlet box and then raise the canopy H against ceiling and screw the screw collar ring G to the screw collar E STEP 2 Install lamps CLEANING To clean wipe fixture with a soft cloth Clean glass with a mild soap Do not use abrasive materials such as scouring pads or powders steel wool or abrasive paper ORDERING PARTS Keep this sheet for future reference and in case you need to order replacement parts All parts for this fixture can be ordered from place of purchase Be sure to use exact wording from illustration when ordering parts
3. INSTALLATION AND SAFETY INSTRUCTIONS WARNING BE SURE THE ELECTRICITY TO THE WIRES YOU ARE WORKING ON IS SHUT OFF EITHER THE FUSE REMOVED te pee need ee are to ag ae fixture Be sure to OR THE CIRCUIT BREAKER OFF ollow the steps in the order given Under no circumstances should a fixture be hung on house electrical wires nor should a swag type fixture be installed on a ceiling which contains a radiant type heating system Read instructions carefully If you are unclear as to how to proceed consult a qualified electrician OUTLET BOX WIRE CONNECTORS GROUND WIRE lt lt MOUNTING BAR A OUTLET BOX OUTLET BOX SCREWS gt GROUND WIRE WIRE CONNECTORS PA ee A lt _______ SCREW COLLAR 5 BAR A RING G A a OUTLET BOX SCREWS GROUNDING AND MOUNTING BAR LOCK UP z 5 lt CHAIN S R GROUNDING SCREW D lt NIPPLE C CANOPY LOOP I NOT INCLUDED CANOPY HOOK M i WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT ARM J TO OUTLET BOX OR SUPPORTING SYSTEM ABLE TO SUPPORT THE WEIGHT OF THE FIXTURE HOOK L FIXTURE FRAME N DIFFUSER 0 FIGURE 1 ASSEMBLY cba gull Lighting Carefully remove the fixture from the carton and check that all parts are included as shown in Figure 1 amp 2 Be careful not to misplace o any of the screws or parts which are needed to install this fixture n stal f at l O n An d STE
4. P 1 Place glass diffuser O into fixture frame N Safety n st ru ct l O n STEP 2 Attach arms J to canopy hooks M H C 3 5 6 100298 STEP 3 Attach loops K to fixture hooks L STEP 4 Attach loops K Fill In Item Number On Carton And File This Sheet For Fixture Reference ITEM oO to arms J INSTALLATION HC 356 IMPORTANT DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET BOX STEP 1 Secure mounting bar A to outlet box with outlet box screws not supplied Thread nut B on nipple C so that 3 threads are exposed above nut B Thread nipple C into mounting bar A and secure with nut B Attach screw collar E to nipple C STEP 2 Using 2 pairs of pliers open one link of chain S and connect it to the fixture loop I at the top of the fixture STEP 3 Slide the screw collar ring G and canopy H in that order over chain S Open one link on the other end of the chain S and attach it to the screw collar E which has been mounted to the ceiling nipple C BE SURE TO CLOSE ALL CHAIN LINKS COMPLETELY STEP 4 Lace wires up through chain S and pass wires through holes in screw collar E We recommend lacing wire up through every other link of chain S STEP 5 A Take note of the color of the wire s on your fixture Identify which group your fixture wire s falls into and connect the wires according to the directions below GROUP A CONNECT TO BLACK GROUP B CONNECT TO

Download Pdf Manuals

image

Related Search

Related Contents

URC62440 - CimTel!  XtraDrive-DP User Manual  Samsung SNV-3082 surveillance camera  Legislación provincial de BC para niños pasajeros  Samsung NP-R411 用户手册(Windows 7)  Samsung Galaxy Mega 2 User Manual  calefon tiro forzado master 10-13 litros con display  Kraft Newsletter Diciembre PREVIEW  GXP User Manual - Cheap IP Phones  cori-gps gps current interrupter user`s manual rcs pn 720600  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.