1. 527 0313 or visit www homedepot com CE TECH Questions problems missing parts Before returning to store call Commerial Electric Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HOMEDEPOT COM Safety Information IMPORTANT SAFETY INSTRUCTIONS Save These Instructions This portable luminaire has a polarized plug one blade is wider than the other as a feature to reduce the risk of electric shock This plug will fit only one way into a polarized outlet If the plug does not insert fully into the outlet reverse the plug If it still does not fit contact a qualified electrician for assistance Never use with an extension cord unless plug can be fully inserted Do not alter the plug in any way as serious injury or damage may result WARNING To reduce the risk of FIRE ELECTRIC SHOCK EXPOSURE TO EXCESSIVE UV RADIATION OR WARNING Do not install this lighting A system in a wet location INJURY TO PERSONS 1 The bulb becomes hot quickly Only contact the switch plug when turning the light on 2 Do not touch hot lens guard or enclosure 3 Do not remain in the light if skin feels warm 4 Do not look directly at a lit bulb 5 Use only with a 20 watt G8 Xenon bulb 6 Do not operate the unit with a missing or damaged guard lamp containment barrier or UV filter 7 Use only insulated staples or plastic ties to WARNING The National Electrical Code NEC does not per
2. de INCENDIO DESCARGA EL CTRICA EXPOSI CI N A RADIACI N EXCESIVA DE RAYOS ULTRAVIOLETA O LESIONES A LAS PERSONAS ADVERTENCIA No instale este sistema de iluminaci n en un entorno h medo ADVERTENCIA El C digo El ctrico 1 El foco se calienta r pidamente S lo toque el Nacional NEC no permite que los cables interruptor enchufe cuando encienda la luz queden ocultos si al da arse el material 2 No toque el lente caliente la cubierta o la aislante pudiera pasar desapercibido Para protecci n evitar el riesgo de incendio no pase los 3 No permanezca bajo la luz si la piel se siente cables por detr s de las paredes ni de los caliente pa eee 0 P en donde y er odian quedar inaccesibles para revisarlos E ne e rectamente El 1000 encendido oia el cable se Hite revisar 5 Utilice solo focos de xenon G8 de 20 vatios visualmente y hay que sustituirlo de 6 No encienda la unidad si falta la cubierta la inmediato si se observa algun da o barrera de protecci n de la l mpara o el filtro UV o si estos est n da ados 3 7 Para sujetar los cables use s lo grapas A PRECAUCION Apague y desenchufe la aislantes o amarres de pl stico l mpara y deje que se enfr e antes 8 Extienda y fije los cables de tal manera que de cambiar el foco no queden ocultos prensadas o que se da en 9 No pase el cable de suministro de energ a del PRECAUCI N Mantenga la l mpara voltaje de l nea a trav s de orificios de la
3. Item 148 407 148 652 Model EC5930BK XC EC5930WH XC CE TECH USE AND CARE GUIDE 3 PACK CABINET LIGHT KIT THANK YOU We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this under cabinet light kit We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Commercial Electric Warranty The manufacturer warrants this lighting fixture against defects in materials and workmanship for a period of one year from the date of purchase If within this period the product is found to be defective in material or workmanship the product must be returned with a copy of the bill of sale as proof of purchase to the original place of purchase The manufacturer will at its option repair replace or refund the purchase price to the original purchaser or consumer This warranty does not cover light bulbs or the fixture becoming damaged due to misuse accidental damage improper handling and or installation and specifically excludes liability for direct incidental or consequential damages As some states do not allow exclusions or limitations on an implied warranty the above exclusions and limitations may not apply This warranty gives you specific rights and you may also have other rights that vary from state to state Contact the Customer Service Team at 1 877
4. lace the switch O The quick connector plug may O Unplug the fixture and ensure the not be properly installed fixture wire is properly pierced inside the quick connector plug O The power is off O Check that the power supply is on and check the circuit breakers m Art culo 654 102 659 097 CEM TECH moio secscsosicnos Ecsesowh xc GU A DE USO Y CUIDADO JUEGO DE 3 LUCES PARA GABINETE GRACIAS Agradecemos la confianza que ha puesto en Commercial Electric con la compra de este juego de luces para debajo del gabinete Nos esforzamos continuamente para crear productos de calidad dise ados para mejorar su hogar Vis tenos en l nea para ver nuestra l nea completa de productos disponibles para sus necesidades de mejoramiento del hogar Gracias por elegir a Commercial Electric Garant a El fabricante garantiza que esta l mpara estar libre de defectos en materiales y mano de obra por un periodo de un a o a partir de la fecha de su compra Si durante este lapso el producto resulta defectuoso en cuanto a material o mano de obra deber devolverlo al lugar de la compra original junto con una copia de la factura de venta como comprobante de la compra El fabricante seg n su criterio reparar sustituir o reembolsar el precio de la compra al comprador o consumidor original Esta garant a no cubre los focos ni que la luminaria resulte da ado debido a un mal uso da o accidental manejo o instalaci n inapr
5. mbiar el foco de la luminaria O Desconecte la l mpara O Retire la cubierta del lente B del cuerpo de la luminaria D girando en contra de las manecillas del reloj O Retire el foco C jale directamente de manera horizontal O Inserte en el cuerpo de la luminaria socket D el foco nuevo no se incluye utilice un pa uelo desechable o un pa o suave PRECAUCI N Riesgo de incendio Utilice focos de xen n tipo G8 de 20 vatios y 120 voltios NO USE focos de voltaje bajo 12 voltios en esta luminaria Instalaci n 3 Para montar empotrado O Retire la cubierta del lente B del cuerpo de la luminaria D girando en contra de las manecillas del reloj O Separe el cuerpo de la luminaria D de la protecci n de pl stico E O Instale la junta de caucho CC en la parte inferior del cuerpo de la luminaria D O Perfore un orificio de 2 3 8 pulg en la ubicaci n deseada del gabinete de madera O Instale el soporte de montaje EE con los tornillos cortos de montaje DD O Pase el cable de la luminaria F a trav s del orificio y oprima el cuerpo de la luminaria D en el orificio O Coloque de nuevo la cubierta del lente B en el a luminaria D 2 Para montar sobre una superficie O Retire la cubierta del lente B del cuerpo de la luminaria D girando en contra de las manecillas del reloj O Fije el cuerpo de la luminaria D en la ubica ci n deseada debajo del gabinete de madera
6. mit cords to be concealed where damage to insulation may go unnoticed To prevent the risk of fire do not run the cord behind walls ceilings soffits or cabinets where it may be inaccessible for examinatioh The cord should be visually examined periodically and immediately replaced when any damage is noted secure cords 8 Route and secure cords so that they will not be concealed pinched or damaged 9 Do not run the Line Voltage power supply cord A CAUTION Turn off unplug the light and allow it to cool before replacing the bulb through holes in walls ceilings or floors 10 Not intended for recessed installation in ceilings or soffits A CAUTION Keep the lamp away from materials that may burn 11 This cabinet light is not intended for installation in plastic cabinets CAUTION The lit lamp is hot 12 This cabinet light is not intended for installation inside enclosed furnishings such as aquariums kitchen cabinets china cabinets or trophy cases CAUTION Do not touch the bulb at any time Use a soft cloth Oil from skin may damage the lamp Pre Installation PACKAGE CONTENTS ED Se 3 A Glass UV lens preassembled to lens cover B Lens cover preassembled to fixture body D C Bulb preassembled to fixture body D 3 3 Ew Fixture body amp Socket preassembled to plastic housing E 3 Plastic housing Fixture wire preassembled t
7. nd push the fixture body D into the hole O Reinstall the lens cover B to the fixture body D body D optional The fixture wire F can be cut to the desired length if necessary This helps to minimize the amount of wire underneath the cabinets Remove the plug cover 1 from the plug G Press the fixture wire F with grooved side 2 to the right neutral side down and into the front of the plug G Press the fixture wire F down onto the metal prongs Slide the plug cover 1 back onto the plug over the fixture wire F are and Cleanin Before attempting to clean the fixture disconnect the power to the fixture by unplugging the fixtur To clean the fixture use a dry or slightly dampened clean cloth Do not use any cleaners with chemicals solvents or harsh abrasives as damage to the fixture may occur Do not touch a new or existing light bulb with bare hands Oil from skin will damage the bulb and shorten the life of the bulb Bulb replacement Use 20 watt 120 volt G8 Xenon or Halogen bulb A CAUTION Do not use chemical solvents or harsh abrasives to clean the fixture as damage to the fixture or various components may occur rendering the fixture inoperable Troubleshooting The fixture does not work Problem O The light bulb is burned out O Replace the bulb O There is a bad wire connection O Check the wire connections O There is a faulty switch O Test or rep
8. o fixture body D G__ Quick connector plug preassembled to fixture wire Extension cord 3 1 1 F Pre Installation TOOLS REQUIRED Phillips Drill Hammer Hole saw Pencil screwdriver Scissors Safety goggles HARDWARE INCLUDED A NOTE Hardware not shown to actual size AA Bor CC DD EE FF GG HH Wire clip Long mounting Rubber Short mounting Mounting Switch Switch Switch x2 screw x 9 gasket x3 screw x 6 bracket x 3 x1 holder x 1 mounting screw X 1 Installation 1 Installing the optional switch Hot Wire 2 A NOTE use only with wire type SPT 2 O Unsqew andremove the swith cover FF O With scissas separate the neutal wire 1 parallel ridge from the hot wa 2 smooth with printedords of theextension cod F O Cut the hot we 2 and push in to connect bothrwends O Apply foce to the hot wes 2 to m amp e sure the conductive sharp points pi e the wre insulation O0 Route the neual wire 1 through the switch housing O Replace and secue the swith cover FF with a scewdrive O Install the swith holder GG optional to a convenient and accessible location with the sew HH povided F O Secure the swith into the holde Installation 5 Installing the wire clips 6 Installing multiple units O The fixtures can be plugged directly into a standard outlet or the extension cord H O Wire clips AA are provided to secure the fixture wire F to the bottom
9. of the cabinet O Insert the fixture wire F into the wire clips AA and secure to the wood cabinet with a hammer not included I Installing or relamping the fixture O Unplug the fixture O Remove the lens cover B from the fixture body D by turning counterclockwise O Remove the bulb C by pulling straight out in a horizontal direction O Insert the new bulb not included into the fixture body socket D using a tissue or soft cloth Oil from the skin may damage bulb CAUTION Risk of fire Use 20 watt 120 volt type G8 base Xenon bulbs Do not use low voltage 12 volt bulbs in this fixture Installation 2 Installing on a surface mount O Remove the lens cover B from the fixture O A Installing the quick connector plug O C O O O Secure the fixture body D to the desired 3 Installing on a recessed mount O Remove the lens cover B from the fixture body D by turning counterclockwise O Separate the fixture body D from the plastic body D by turning counterclockwise location under the wood cabinet with the housing E three long mounting screws BB O Install the rubber gasket CC to the underside of Reinstall the lens housing B to the fixture the fixture body D O Drill a 2 3 8 in hole into the desired location in the wood cabinet O Install the mounting bracket EE with short mounting screws DD O Route the fixture wire F through the hole a
10. opiados y asimismo de manera especifica excluye la responsabilidad por da os directos incidentales o emergentes Puesto que algunos estados no permiten las exclusiones o limitaciones en una garant a impl cita es posible que las exclusiones y limitaciones anteriores no se apliquen Esta garant a le brinda derechos legales especificos y usted podr a tener tambi n otros derechos que var an seg n el estado Comun quese con el equipo de Atenci n al Cliente al 1 877 527 0313 o visite www homedepot com CE TECH Tiene preguntas problemas o le faltan piezas Antes de devolver a la tienda comun quese a Atenci n a Clientes de Commercial Electric entre las 8 00 a m y las 6 00 p m EST de lunes a viernes 1 877 527 0313 HOMEDEPOT COM Informaci n sobre la seguridad INSTRUCCIONES IMPORTANTES DE SEGURIDAD Conserve este instructivo Esta luminaria port til cuenta con un enchufe polarizado una clavija es m s ancha que la otra con el fin de reducir el riesgo de descarga el ctrica Este enchufe encajar s lo de una forma en un tomacorriente polarizado Si el enchufe no se inserta completamente en el tomacorriente volt elo Si aun as no encaja bien comun quese con un electricista autorizado para pedirle asistencia Nunca la utilice con una extensi n a menos que el enchufe pueda insertarse completamente No altere el enchufe ya que esto puede provocar lesiones o da os graves ADVERTENCIA Para reducir el riesgo
11. ornillo de para cable para montaje decaucho para montaje de montaje x1 el interruptor montaje para x2 x9 x3 x6 x3 x1 el interruptor x1 Instalaci n 1 C mo instalar el interruptor opcional Cable de carga 2 A NOTA Use s lo con cable tipo SPT 2 O Destornille y retire la cubierta del interruptor FF O Con unas tijeras separe el cable neutro 1 borde paralelo del cable de carga 2 liso con palabras impresas de la extensi n F O Corte el cable de carga 2 y presione para conectar ambos extremos del cable O Aplique fuerza a los cables de carga 2 para asegurar de que las puntas conductoras atraviesen el aislante del cable O Extienda el cable neutro 1 por la cubierta del interruptor O Con un destornillador coloque de nuevo la cubierta del interruptor FF y f jela O Instale el soporte para el interruptor GG opcional en F una ubicaci n pr ctica y accesible con el tornillo HH incluido O Fije el interruptor en el soporte Instalaci n C mo instalar las grapas para cable O Las grapas para cable AA se proporcionan para fijar el cable de la luminaria F a la parte inferior del gabinete O Inserte el cable de la luminaria F en las grapas para cable AA y con un martillo no incluido fijelo al gabinete de madera 6 Para instalar varias unidades O Las luminarias pueden conectarse directa mente a un tomacorriente est ndar o a la extensi n H C mo instalar o ca
12. pared A lejos de material que pueda quemarse del techo o del piso 10 No apto para instalaci n empotrada en techos o plafones hi PRECAUCI N La l mpara encendida est caliente 11 Esta luz para gabinete no es apta para instalarse en gabinetes de pl stico IN 7 12 Esta luz para gabinete no es apta para instalar A toc O ois iis tail Use un pa o suave La grasa de la piel dentro de mobiliario cerrado como peceras gabinetes de cocina vitrinas o vitrinas para trofeos puede da ar la l mpara Previo a la instalaci n CONTENIDO DEL PAQUETE Descripci n Cantidad A Lente de cristal UV premontado a la tapa del lente B B Cubierta del lente premontado al cuerpo de la luminaria D c ia D c Foco premontado al cuerpo de la luminaria D Cuerpo de la luminaria y Socket premontado al protector de pl stico E F Cable de la luminaria premontado al cuerpo de la luminaria D G Enchufe de conector r pido premontado al cable de la luminaria F H Extensi n w 3 E protector de plstico ooo T EN Previo a la instalaci n Lentes Tijeras Destornillador Taladro Martillo Sierra L piz protectores Phillips perforadora HERRAJE INCLUIDO pANOTA Los herrajes no se muestran en su tama o real PT AA BB CC DD EE FF GG HH Grapa Tornillo largo Junta Tornillo corto Soporte Interruptor Soporte para T
13. roblema Causa posible Soluci n La luminaria O El foco se ha fundido O Sustituya el foco no funciona O Hay una mala conexi n de O Revise las conexiones de los cables los cables O Hay un interruptor defectuoso O Verifique o cambie el interruptor O Es posible que el enchufe de O Desenchufe la luminaria y aseg rese conector r pido no est de que el cable est debidamente instalado correctamente perforado dentro del enchufe de conector r pido O El suministro de energ a el ctrica est apagado O Verifique que el suministro de energ a el ctrica est prendido y revise los disyuntores
14. utilizando los tres tornillos largos de montaje BB O Coloque de nuevo la protecci n del lente B en el cuerpo de la luminaria D C mo instalar el enchufe de conector r pido opcional O Si es necesario el cable de la luminaria F puede cortarse a la longitud deseada Esto ayuda a reducir la cantidad de cable por debajo de los gabinetes O Retire la cubierta 1 del enchufe G O Presione el cable de la luminaria F con el lado estriado 2 hacia la derecha lado neutro en el frente del enchufe G O Presione el cable de la luminaria F sobre las clavijas met licas O Deslice la cubierta 1 en el enchufe sobre el cable de la luminaria F Cuidado y limpieza O Antes de que intente limpiar esta luminaria desconecte la electricidad del dispositivo desenchufe la luminaria O Para limpiarlo utilice un pa o seco o ligeramente h medo O No use limpiadores que contengan sustancias qu micas disolventes o abrasivos fuertes ya que pueden da ar la luminaria O No toque los focos nuevos o el que est en uso con las manos sin protecci n La grasa de la piel da a el foco y reduce su duraci n O Para reemplazar el foco Utilice un foco de xen n G8 o hal gena de 20 vatios y 120 voltios PRECAUCI N No utilice disolventes qu micos o abrasivos fuertes para limpiar esta luminaria ya que ste o sus componentes pueden da arse lo cual har a que no funcione Resoluci n de problemas P

Download Pdf Manuals

image

Related Search

Related Contents

  User's manual, JED AVR595 SBC using Atmel's ATmega2561  JVC KW-XC777 User's Manual  vacon nx convertisseurs refroidis par liquide manuel d`utilisation  Manual - SISGEO North America  DOMIS ALARMES 2060470  Aiptek PocketDV AHD Z500 Plus  Bike Helmet Manual 5+ Layed out SP  Bedienungsanleitung/Garantie KB 3538 KÜHLBOX  SmartZone EZ Manual - Super Products Co.,Ltd.  