Home

ZyXEL Dimension Ethernet Switches User's Manual

image

Contents

1. 9 COM1 COM2 gt VT100 gt 8 gt 9600 1 gt 20 Ethernet Dimension
2. LNK ACT Ethernet 100 21
3. OPRANE UTP STP RJ 45 B 100 328 KIR Table 1 EEE RAR 10Mbps 1000 2 pair UTP STP Category 3 4 or 5 100Mbps 1000 2 pair UTP STP Category 5 1000Mbps 1000 4 pair UTP STP Category 5 BEHES U0 LNK ACT PERLE 9 FLAT gt gt gt VT100 fi BEBE 9600 TERCAS ESRI MESIA A SAT AF COMI COM2 REE COM Ba BUE FAITES sb
4. 19 Ethernet Dimension RJ 45 Fast Ethernet 10 100 Gigabit 10 100 1000 10 100 Ethernet
5. 1 2 3 4
6. RJ 45 Ethernet UTP STP 100 1 10 1000 2 UTP STP 3 4 5 100 1000 2 UTP STP 5 1000 1000 4 UTP STP 5 LNK ACT PWR
7. 1 EE sb A SES 8 Dimension SU IE BC Wa aa anata Eq UE SRE Ea gs 6 BE HT Fa LNK ACT 7 z aid WE Ee Wa ai Bea ESA 100 328 IR Dimension Ethernet Switches DEUTSCH Einleitung Diese Kurzanleitung dient der Verwendung aller ZyXEL Ethernet Switche Das Aussehen ihres Ger tes kann von den unten gezeigten Abbildungen abweichen Installation Alle Switche k nnen als Einzelger te verwendet werden wobei einige alternativ in 19 Zoll Standardracks montiert werden k nnen F r eine ausreichende Bel ftung sollte vor dem Switch ein Freiraum von mindestens 10 cm und hinter dem Switch ein Freiraum von mindestens 8 cm gelassen werden Wenn Sie Switche bereinander anordnen lassen Sie einen Freiraum zwischen den Ger ten Tisch Montage 1 Legen Sie den Switch auf eine g
8. Contatti il suo rivenditore l alimentazione II LED LNK ACT non si Verificare che la periferica collegata sia accesa e correttamente collegata accende o lampeggia allo switch Inoltre assicurarsi che la scheda di rete sia attiva con i quando viene collegata dispositivi collegati Verificare che i cavi di rete non superino i 100 metri una periferica 15 Switches Ethernet Dimension FRANGAIS Introduction Ce Guide de Prise en Main est destin l utilisation des swithces Ethernet Dimension Votre appareil peut diff rer des illustrations ci dessous Installation Tous les switches peuvent tre utilis s comme appareils autonomes sur un bureau tandis que certains peuvent tre mont s dans des chassis au standard Pour une bonne ventilation laissez 10 cm d espace libre devant et 8 cm derri re le switch Laissez de entre les switches si vous les montez en cascade Installation sur un bureau 1 Posez le switch sur une surface plate et droite 2 Si votre switch est livr avec des pieds non attach s collez les sur chaque coin du socle du switch Ces pieds permettent de prot ger le switch contre les vibrations de chocs et assurent l espace n cessaire si vous montez plusieurs switches en cascade Installation en Ch ssis 1 Placez un angle sur les trous d un c t du switch et fixez le avec les vis qui sont plus petites que les vis
9. 3 4 or 5 100Mbps 1000 2 paires UTP STP Categorie 5 1000Mbps 100 0 4 paires UTP STP Categorie 5 La LED LNK ACT doit clignoter lorsque des donn es sont transmises entre votre switch et un appareil connect Connexion du Courant Connectez une extr mit du c ble courant ou de l adaptateur d alimentation fourni sur la prise courant du switch et l autre extr mit sur la prise de courant appropri e La LED PWR doit tre allum e si le switch re oit du courant Port Console Switches Manageables Uniquement Si votre switch a un port console vous pouvez utiliser un mulateur de terminal pour la gestion locale Connectez l extr mit m le 9 broches d un c ble console sur le port console de votre switch Connectez l extr mit femelle sur un port s rie COM1 COM2 ou autre port COM de votre ordinateur Configurez l ordinateur avec un logiciel d mulation de terminal sur les param tres suivants gt Emulation de Terminal VT100 gt Sans parit 8 bits de donn es 1 bit gt 9600 bps d arr t gt Aucun contr le de flux 17 witches Ethernet Dimension R solution d Erreurs PROBLEME ACTION CORRECTIONNELLE Aucune des LEDs est V rifiez que le cable ou l adaptateur d alimentation fourni est correctement allum e lorsque le branch sur la prise du switch et la prise lectrique Si l erreur persiste courant est connect vous avez peut tre un probl me mat riel veuillez alors con
10. i tipi di cavi di rete usati per le diverse velocit di collegamento Tavola 1 Tipi di cavo di rete VELOCITA TIPI DI CAVO DI RETE 10Mbps 1000 2 pair UTP STP Categoria 3 4 or 5 100Mbps 1000 2 pair UTP STP Categoria 5 1000Mbps 1000 4 pair UTP STP Categoria 5 Il LED LNK ACT dovrebbe illuminarsi quando i dati iniziano ad essere trasmessi fra lo switch e le periferiche collegate Collegamenti di Alimentazione Collegare un capo del cavo di alimentazione fornito o del trasformatore ad una presa di corrente adatta Il LED PWR dovrebbe accendersi se lo switch viene alimentato Porta Console Solo Switch programmabili Se lo switch ha una porta console si pu usare un emulatore di controllo locale Collegare il capo maschio 9 pin del cavo console alla porta console dello switch Collegare il capo femmina alla porta seriale COMI o altre porte COM del computer Configurare il computer tramite un software di emulazione di terminale con i seguenti parametri gt Emulazione di terminale VT100 gt 9600 bps gt Nessuna parit 8 bit dati 1 bit di stop gt Nessun controllo di flusso 14 Dimension Ethernet Switches Analisi dei guasti PROBLEMA AZIONE CORREYTIVA Nessun LED si Verificare che l adattatore fornito o il cavo di alimentazione dello switch sia accende quando viene collegato alla presa di corrente Se il problema persiste potrebbe trattarsi di collegata un guasto hardware
11. k nnen Netzwerkkabel F r RJ 45 Ports k nnen Sie UTP unshielded twisted pair oder STP shielded twisted pair Netzwerkkabel verwenden Achten Sie darauf dass die Kabell nge zwischen den Anschliissen weniger als 100 Meter betragt Die folgende Tabelle verdeutlicht die fiir die verschiedenen Geschwindigkeiten verwendeten Netzwerkkabel typen Tabelle 1 Netzwerkkabeltypen GESCHWINDIGKEIT NETZWERKKABELTYP 10Mbit s 1000 2 paarig UTP STP Cat 3 4 oder 5 100Mbit s 1000 2 paarig UTP STP Cat 5 1000Mbit s 1000 4 paarig UTP STP Cat 5 Die LNK ACT LED sollte aufblinken wenn Daten zwischen Ihrem Switch und einem angeschlossenen Ger t versendet werden Stromversorgung Verbinden Sie das eine Ende des mitgelieferten Stromkabels oder Netzteils mit dem daf r vorgesehenen Anschluss am Switch Verbinden Sie nun das andere Ende mit der entsprechenden Stromquelle Die PWR LED sollte leuchten wenn der Switch mit Spannung versorgt wird Konsolen Port nur managebare Switche Besitzt Ihr Switch einen Konsolen Port so k nnen Sie zu Konfigurationszwecken eine Terminal Emulation verwenden Verbinden Sie den m nnlichen 9 Pin Stecker eines Konsolenkabels mit dem Konsolen Port des Switch Verbinden Sie entsprechend den weiblichen Stecker mit einem seriellen Port COM1 COM2 oder anderer COM Port Ihres Computers Richten Sie die Terminal Emulations Software auf Ihrem Rechner mit den folgenden Parametern ein gt VT100 Te
12. Dimension Ethernet Switches Quick Start Guide 3 2005 English Haar Deutsch Espanol Italiano Frangais ZyXEL Unleash Networking Power Dimension Ethernet Switches Quick Start Guide Contents ENGLISH geniali let baa 2 listelli 4 DEUTSCH pri A 7 ESPANOL Eee 10 IRALIANO cana 13 FRANCAIS Senat 16 Se ee 19 Dimension Ethernet Switches ENGLISH Introduction This Quick Start Guide is for use with all ZyXEL Ethernet switches Your device may differ from the illustrations below Installation All switches can be used as a standalone device while some can alternately be mounted on standard EIA racks For proper ventilation allow at least 4 inches 10 cm of clearance at the front and 3 4 inches 8 cm at the back of the switch Leave space between switches if stacking Desktop Installation 1 Set the switch on a smooth level surface 2 If your switch comes with unattached rubber feet attach them to each corner on the bottom of the switch These rubber feet help protect the switch from shock or vibration and ensure space between devices when stacking Rack mounted Installation 1 Align one bracket with the holes on one side of the switch and secure it with bracket screws smaller than the rack mounting screws Similarly attach the other bracket 2 After attaching both mounting brackets position the switch in the rack by lining up th
13. Questi piedini aiutano a proteggere lo switch da shock vibrazioni assicurano lo spazio fra le periferiche se incolonnate Installazione in armadio Rack 1 Allineare una staffa i buchi su un lato dello switch e fissarla con viti da staffa pi piccole di quelle per il montaggio dell armadio Similarmete attaccare le altre staffe 2 Dopo aver fissato entrambe le staffe posizionare lo switch nell armadio allineando i fori delle staffe con quelli dell armadio Fissare lo switch all armadio con le viti di montaggio 13 Dimension Ethernet Switches Collegamenti Hardware Porte RJ 45 Auto negozianti e Auto invertenti Le porte dello switch sono auto negozianti e auto invertenti A seconda del modello le porte possono essere di tipo Fast Ethernet 10 100 Mbps Gigabit 10 100 1000 Mbps Le porte auto negozianti inoltre riconoscono automaticamente la velocita di trasmissione dati e supportano sia la modalita di trasferimento dati half duplex solo 10 100 Mbps sia full duplex Auto invertente significa che lo switch essere collegato ad un computer a hub utilizzando sia un cavo Ethernet dritto che uno crossover incrociato Cavi di rete Si possono usare cavi a coppia incrociata non schermati UTP o a coppia incrociata schermati STP per port RJ 45 Assicurarsi che la lunghezza dei cavi fra i collegamenti non superi i 100 metri La seguente tabella descrive
14. de montage en ch ssis De la m me mani re attachez l autre angle 2 Apr s avoir attach les deux angles positionnez le switch dans le ch ssis en alignant les trous des angles avec les trous appropri s sur le ch ssis Fixez le switch sur le ch ssis avec les vis de montage en ch ssis 16 Switches Ethernet Dimension Connexions Mat rielles Ports RJ 45 a n gociation et croisement automatiques Votre switch est livr avec des ports n gociation et croisement automatiques Selon le mod le ces ports sont des ports soit fast Ethernet 10 100 Mbps soit Gigabit 10 100 1000 Mbps Les ports a n gociation automatique peuvent d tecter la vitesse des transmissions entrantes et autoriser soit le mode de transfert half duplex 10 100 Mbps seulement soit le mode de transfert full duplex Le croisement automatique signifie que vous pouvez connecter le switch un ordinateur ou un hub en utilisant soit un cable Ethernet droit soit un cable Ethernet crois Cables R seau Vous pouvez utiliser des cables Ethernet paire de cuivre non blind s UTP ou blind s STP pour les ports RJ 45 Assurez vous que la longueur entre les connexions ne d passe pas 100 m tres Le tableau suivant d crit les types de c bles r seau utilis s pour diff rentes vitesses de connexions Tableau 1 Types de Cables R seau VITESSE TYPE DE CABLE RESEAU 10Mbps 1000 2 paires UTP STP Categorie
15. e holes in the brackets with the appropriate holes on the rack Secure the switch to the rack with the rack mounting screws Hardware Connections Auto negotiating and Auto crossover RJ 45 ports Dimension Ethernet Switches Your switch comes with auto negotiating auto crossover ports Depending on the model these ports are either fast Ethernet 10 100 Mbps or Gigabit 10 100 1000 Mbps ports Auto negotiating ports can detect the speed of incoming transmissions and allow either half duplex transfer mode 10 100 Mbps only or full duplex mode Auto crossover means that you can connect the switch to a computer or hub using either a straight through or a crossover Ethernet cable Network Cables You can use unshielded twisted pair UTP or shielded twisted pair STP Ethernet cables for RJ 45 ports Make sure the cable length between connections does not exceed 100 meters 328 feet The following table describes the types of network cable used for different connection speeds Table 1 Network Cable Types SPEED NETWORK CABLE TYPE 10Mbps 1000 2 pair UTP STP Category 3 4 or 5 100Mbps 1000 2 pair UTP STP Category 5 1000Mbps 1000 4 pair UTP STP Category 5 The LNK ACT LED should flash when data is being sent between your switch and a connected device Power Connection Connect one end of the supplied power cable or power adaptor to the power receptacle on the switch and the other end to the appro
16. eZ BER 4 10 ER 3 4 8 BIER ZAHN TEEN ERIRE 1 RES AE EI 2 f BBG HED Be IAEA gt pu o ur BE 1 FERRER E 2 METIA IA LS EIA LEE Dimension RJ 45 HU I RJ 45 J 7 1 10Mbps 100Mbps 1000Mbps ELAP SEE 10Mbps
17. latte ebene Unterlage 2 Sollte Ihr Switch mit nicht montierten Gummif en geliefert worden sein bringen Sie diese an jeder Ecke der Ger teunterseite an Diese Gummif e dienen dem Schutz vor St en und Vibrationen und gew hrleisten den Freiraum zwischen den Ger ten wenn diese bereinander angeordnet werden Rack Montage 1 Richten Sie die B gel an den seitlich angeordneten L chern des Switch aus und sichern Sie diese mit den daf r vorgesehenen Schrauben die kleiner sind als die Schrauben die daf r verwendet werden um das Ger t im Rack zu befestigen Gehen Sie analog dazu mit dem anderen B gel vor 2 Nachdem beide Montageb gel angebracht sind positionieren Sie den Switch im Rack indem Sie die L cher der Montage b gel an den Montagel chern des Rack ausrichten Sichern Sie den Switch mit den Rack Schrauben Dimension Ethernet Switches Hardware Anschl sse 10Base T 100Base TX RJ 45 Ports mit Auto Negotiating Auto Sensing MDI MDIX Funktion Ihr Switch ist mit 10 100 1000 Mbit s RJ 45 Ports mit Auto Negotiating Funktion ausgestattet die die Geschwindigkeit empfangener Datenpakete automatisch erkennen und entsprechend einstellen Sie erm glichen Datentransferraten von 10 100 oder 1000 Mbit s im Halb oder Vollduplex Modus Auto Sensing bedeutet dass Sie den Switch tiber ein Straight Through oder Crossover Netzwerkkabel mit einem Computer oder einem Hub verbinden
18. luci n de problemas PROBLEMA ACCI N Ning n LED est activo Verifique que el cable de alimentaci n o cable adaptador de alimentaci n y el cable de est conectado al conector de alimentaci n del switch y a la toma de alimentaci n est alimentaci n adecuada Si el error persiste seguramente debe tener un conectado problema de hardware contacte con su distribuidor El LED LNK ACT no se Verifique que los dispositivos conectados est n encendidos enciende y no correctamente conectados a su switch Tambi n aseg rese de que las parpadea cuando el tarjetas Ethernet de los dispositivos conectados funcionan correctamente switch est encendido Verifique que los cables de red no superan los 100 metros 12 Dimension Ethernet Switches ITALIANO Introduzione La guida utente generalizzata per tutti gli switch Ethernet ZyXEL suo prodotto potrebbe essere differente rispetto alle illustrazioni seguenti Installazione Tutti gli switch possono essere usati come periferica standalone ma possono anche essere montati in armadi standard EIA Per una ventilazione adeguata lasciare almeno 10 cm di spazio di fronte e 8 cm sul retro dello switch Lasciare spazio fra gli switch se incolonnati Installazione Desktop 1 Posizionare lo switch su una superficie regolare e livellata 2 Se lo switch dovesse arrivare senza i piedini di gomma attaccarli in ogni angolo sul fondo dello switch
19. nzados UTP o pares trenzados apantallados STP para los puertos RJ 45 Aseg rese de que la longitud de los cables no supera los 100 metros 328 pies La siguiente tabla describe los tipos de cable usados para las diferentes velocidades de conexi n Tabla 1 Tipos de cables de red VELOCIDAD TIPO DE CABLE DE RED 10Mbps 1000 2 pares UTP STP Categoria 3 4 5 100Mbps 100 2 pares UTP STP Categor a 5 1000Mbps 1000 4 pares UTP STP Categor a 5 El LED LNK ACT debe parpadear cuando se env an o reciben datos entre su switch y otros dispositivos Conexi n de alimentaci n Conecte un extremo del cable de alimentaci n o adaptador de alimentaci n suministrado a la conexi n de alimentaci n del switch y el otro extremo a la toma de corriente apropiada El LED PWR debe permanecer encendido si el switch est recibiendo alimentaci n Puerto consola Solo switches gestionables Si su switch tiene puerto consola puede usar un emulador de terminal para gesti n local Conecte el extremo macho de 9 pines del cable consola al puerto consola del switch Conecte el extremo hembra al puerto serie COMI COM2 o otro puerto COM de su ordenador Configure el puerto serie de su ordenador con un software emulador de terminal con los siguiente par metros gt emulador de terminal VT100 gt 9600 bps gt Sin paridad 8 bits de datos 1 bit de parada gt Sin control de flujo 11 Switches Ethernet Dimension So
20. parte posterior del switch Deje alg n espacio entre switches si los estaca Instalaci n de sobremesa 1 Coloque el switch en un espacio liso nivelado y firme 2 Si su switch incorpora pies de caucho eng nchelos a cada esquina de la superficie inferior del switch Los pies de caucho protegen el switch de golpes o vibraciones y crean un espacio entre dispositivos en caso de estacar Instalaci n en Rack 1 Alinee uno de los anclajes con los agujeros en un lado del switch y f jelo con los tornillos Haga lo mismo con el otro anclaje en el otro lado del switch 2 Despu s de colocar los dos anclajes posicione el switch en el rack alineando apropiadamente los agujeros de los anclajes con los agujeros del rack Fije el switch al rack con los tornillos de fijaci n al rack 10 Switches Ethernet Dimension Conexiones Hardware Puertos 10Base T 100Base TX RJ 45 autonegociables MDI MDIX autodetectables Su switch incorpora puertos RJ 45 10 100 1000 Mbps con auto negociaci n lo que permite que el switch detecte la velocidad de transmisi n entrante y ajustar autom ticamente sin intervenci n de configuraci n manual Ello permite transferencias de datos 10 100 1000 Mbps tanto en modo half duplex como en modo full duplex La auto detecci n permite conectarse a un PC o hub usando tanto un cable Ethernet directo como cruzado Cables de red Puede usar cables Ethernet de pares tre
21. priate power source The PWR LED should turn steady on if the switch is receiving power Console Port Managed Switches Only If your switch has a console port you can use a terminal emulator for local management Connect the male 9 pin end of a console cable to the console port of the switch Connect the female end to a serial port COMI or other COM port of your computer Configure the computer with terminal emulation software to the following parameters gt VT100 terminal emulation gt No parity 8 data bits 1 stop bit gt 9600 bps gt No flow control Troubleshooting PROBLEM CORRECTIVE ACTION None of the LEDs are Verify that the included power cable adaptor is connected to the switch s on when the power is power receptacle and appropriate power source If the error persists you connected may have a hardware problem and should contact your vendor The LNK ACT LED Verify that the attached device s is turned on and properly connected to does not light up or your switch Also make sure the Ethernet cards are working on the attached flash when a device is devices Verify that the network cable does not exceed 100 meters connected Dimension
22. rminal Emulation gt Flow gt 9600 Bit s Control Datenflusskontrolle gt Keine Parit t Parity 8 Datenbits 1 Stopp Bit Dimension Ethernet Switches Fehlersuche PROBLEM KORREKTURMASSNAHME Nach Anschluss der Stellen Sie sicher dass das mitgelieferte Stromkabel oder Netzteil mit dem Stromversorgung dafur vorgesehenen Anschluss am Switch bzw mit der entsprechenden leuchtet keine der LEDs Stromquelle verbunden ist Sollte das Problem weiterhin bestehen haben Sie m glicherweise Hardwareproblem Wenden Sie sich in diesem Fall an Ihren Handler Bei Anschluss eines Ger tes leuchtet bzw blinkt die LNK ACT LED nicht auf Stellen Sie sicher dass die angeschlossenen Gerate angeschaltet und ordnungsgem mit Ihrem Switch verbunden sind Achten Sie auch darauf dass die Netzwerkkarten der angeschlossenen Gerate funktionieren Uberpriifen Sie ob die Lange des Netzwerkkabels 100 Meter nicht berschreitet Switches Ethernet Dimension ESPANOL Introduccion Esta Guia de Instalacion Rapida puede usarse con todos los switches Ethernet de ZyXEL Su equipo puede ser diferentes al de las ilustraciones de abajo Instalacion Todos los switches pueden usarse como dispositivo independiente mientras que algunos modelos alternativamente pueden ser montados en racks estandares Para una ventilaci n correcta deje al menos 10 cm de espacio libre al frente 8 cm en la
23. tacter votre revendeur local La LED LNK ACT ne V rifiez que les appareils connect s sont allum s et bien connect s sur s allume pas ou votre switch Assurez vous galement que les cartes Ethernet des appareils clignote pas lorsqu un connectes fonctionnent correctement V rifiez que votre cable r seau ne appareil est connect d passe pas 100 m tres 18 Ethernet Dimension Ethernet ZyXEL 10 8

Download Pdf Manuals

image

Related Search

Related Contents

EIB-001 Dry-Type Distribution Transformer  User Manual - Howard Store  Ricoh Aficio MPc2051AD  Communications Modbus Série Akros  JVC HR-S9500E User's Manual  Anais do III ENIC FAMINAS-BH  PDFファイル/124KB  Guía del administrador de Document Portal  Pocket PC  IDEC ONC Series OpenNet Controller User`s Manual  

Copyright © All rights reserved.
Failed to retrieve file