Home

Vanguard Heating VS18PR User's Manual

image

Contents

1. 103448 WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No Date Purchased Always specify model and serial numbers when communicating with the factory We reserve the right to amend these specifications at any time without notice The only warranty applicable is our standard written warranty We make no other warranty expressed or implied LIMITED WARRANTY VENT FREE PROPANE GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for three 3 years and five 5 years on stainless steel burners from the date of first purchase provided that the product has been properly installed operated and maintained in accordance with all applicable instructions There is no warranty on the batteries To make a claim under this warranty the Bill of Sale or cancelled check must be presented This warranty is extended only to the original retail purchaser This warranty covers the cost of part s required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center Warranty part s MUST be obtained through authorized dealers of this product and or DESA International who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qualified i
2. LOG SIZING REQUIREMENTS Minimum Firebox Size Log Front Size Height Depth Width 18 17 14 20 24 17 14 26 30 17 14 32 Carefully follow the instructions below This will ensure safe installation into a masonry or U L listed manufactured fireplace or an AGA listed vent free firebox approved for use with these gas log heaters Minimum Wall and Ceiling Clearances see Figure 4 A Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches B Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches 42 16 Figure 4 Minimum Clearance to Wall and Ceiling Minimum Non Combustible Material Clearances If Not Using Mantel Note If using a mantel go to page 10 If not using a mantel follow the information on this page You must have non combustible material s above the fireplace opening Non combustible materials such as slate marble tile etc must be at least 1 2 inch thick With sheet metal you must have non combus tible material behind it Non combustible material must extend at least 8 up for all models If non combustible material is less than 12 you must install the fireplace hood accessory See chart and Figure 5 on page 10 for minimum clearances Continued o 103448 INSTALLING Continued Non Combustible Material Distance
3. VANGUARD UNVENTED VENT FREE PROPANE LP GAS LOG HEATER This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by state or local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer OWNER S OPERATION AND INSTALLATION MANUAL 18 24 and 30 Remote Ready Models vst 8PR VS24PR VS30PR WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational proce dures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage per sonal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING These gas log sets are for installa WHAT TO DO IF YOU SMELL GAS tion in a masonry solid fuel burning fireplace a Do not try to light any appliance U L listed manufactured solid fuel burning Do not touch any electrical switch do fireplace or an AGA design certified vent free not use any phone in your building firebox including LogMate series fireboxes Immediately call your gas supplier and stoves listed for use with these gas log from a neighb
4. Check all joints from propane supply tank to manual shutoff valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak Correct all leaks at once Pressure Testing Heater Gas Connections l NN Open manual shutoff valve see Figure 14 2 Open propane supply tank valve 3 4 Check all joints from manual shutoff valve to gas control see Figure 14 Apply mixture of liquid soap Make sure control knob of heater is in the OFF position and water to gas joints Bubbles forming show a leak Correct all leaks at once Light heater see Operating Heater pages 18 through 21 Check all other internal joints for leaks Turn off heater see To Turn Off Gas to Appliance page 20 Open Manual _ Shutoff Valve Closed Figure 14 Manual Shutoff Valve Manual Shutoff Gas Control Location Valve Propane TP Supply Tank Figure 15 Checking Gas Joints 103448 INSTALLING Continued INSTALLING LOGS A WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury Each log is marked with a number These numbers will help you identify the log when installing It is very important to install these logs exactly as instructed Do not modify logs Only use logs supplied w
5. Provide extra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Ventilated Air Attic Outlet il Alt To Attic eh To Crawl Inlet Air i Ventilated Inlet Air Crawl Space Figure 3 Ventilation Air from Outdoors INSTALLING NOTICE A qualified service person must install heater Follow all local codes NOTICE State or local codes may only allow operation of this appliance in a vented configuration Check your state or local codes A WARNING Make sure the remote selector switch is in the OFF position before installing heater A WARNING Before installing in a solid fuel burning fireplace the chimney flue and firebox must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage If damaged operate heater with flue damper closed A WARNING Seal any fresh air vents or ash clean out doors located on floor or wal
6. 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by local natural gas company 3 Observe minimum installation clearances see pages 9 12 4 Clean burners see Cleaning and Maintenance page 23 or replace burner orifice s A WARNING If you smell gas e Shut off gas supply instructions e Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s e If you cannot reach your gas supplier call the fire department IMPORTANT Operating heater where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cements and glues new carpet or textiles etc create fumes These fumes may mix with combustion air and create odors These odors will disappear over time OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Heater produces a click ing ticking noise just after burners are lit or shut off 1 Metal expanding while heating or contracting while cooling 1 This is common with most heaters If noise is excessive contact qualified service person Heater produces unwanted odors 1 Heater burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply 3 Gas
7. 103587 01CK M11084 26 103284 02 099387 09 101004 01 101004 02 103783 01 099998 01 103580 03 103580 02 103576 02 103577 03 103578 03 103579 01 M11084 26 103778 01 098249 01 103780 01 101330 06 101008 01 101007 01 100999 03 103984 03 098271 06 102445 01 103588 01 103782 01 M12461 26 103781 02 097264 02 103784 02 103784 01 103587 01CK M11084 26 103284 02 099387 09 101004 02 101004 06 103783 01 099998 01 DESCRIPTION PA Left Front Log 1L Right Front Log 1R Bottom Middle Log Rear Log 3 Top Middle Log 4 Crossover Log Screw O D S Pilot Nut Pilot Bracket Front Burner Assembly Crossover Burner Gasket Crossover Burner Rear Burner Assembly Base Assembly and Decal Ignitor Cable Piezo Ignitor Heat Shield Valve Bracket Screw Gas Control Male Fitting Flame Adjustment Knob Control Knob Switch Plate Screw Wiring Harness Pilot Tube Rear Burner Injector Front Burner injector Remote Burner Tube Switch PARTS AVAILABLE NOT SHOWN 100563 01 103877 01 100565 01 100639 01 101137 02 101416 27 GA6060 100563 01 103877 01 100565 01 100639 01 101137 02 101416 27 GA6060 Warning Plate Lighting Instructions Plate Warning Plate Fastener Caution Decal Hardware Kit Information Video Lava Rock a Ce CC es CC Ce CC me CC CC es Ce ee Cg EC gt a a ee eo 103448 ACCESSORIES Purchase these heater accessories from your local dealer If they can
8. A Requirements for Safe Installation 12 or more Non combustible material OK Between 8 and 12 Install fireplace hood accessory GA6050 or GA6052 see Acces sories page 30 Less than 8 Non combustible material must be extended to at least 8 See Between 8 and 12 above A WARNING Non combustible material must extend 8 above the fireplace opening Heat Resistant Material Figure 5 Heat Resistant Material Slate Marble Tile etc Above Fireplace Minimum Non Combustible Material Clearances If Using Mantel You must have non combustible material s above the fireplace opening Non combustible materials such as slate marble tile etc must be at least 1 2 inch thick With sheet metal you must have non combus tible material behind it Non combustible material must extend at least 8 inches up If non combustible material is less than 12 you must install the fireplace hood accessory Even if non combustible material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See chart below and Figures 6 and 7 page 11 for minimum clearances Non Combustible Requirements for Material Distance A Safe Installation 12 or more Non combustible material OK Between 8 and 12 Install fireplace hood accessory GA6050 or GA6052 see Acces sories page 30 Less than 8 Non combustible material must be extended to at least 8 See Betwe
9. INSTALLING Continued Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 13 Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves A CAUTION Use pipe joint sealant that is resistant to liquid petroleum LP gas Install sediment trap in supply line as shown in Figure 13 Locate sediment trap where it is within reach for cleaning Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly A CAUTION Avoid damage to gas control Hold gas control with wrench when connecting it to gas piping and or fittings From A G A Design Certified External Regulator Manual Shutoff Valve With 11 W C to 1 8 NPT Tap 14 W C Pressure A Approved Flexible Gas Hose if allowed by local codes Gas Control a Tee Joint Pipe Nipple Cap Sediment Trap Figure 13 Gas Connection Purchase the optional A G A design certified manual shutoff valve from your dealer See Accessories page 30 Minimum inlet pressure for purpose of input adjustment
10. page 19 2 Depress control knob and light pilot with match 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Now follow step 9 above 103448 OPERATING HEATER Continued zi OPTIONAL GHRCT HAND HELD REMOTE OPERATION es NOTICE You must light the pilot before using the hand held remote control unit See Lighting Instructions on page 19 Control Knob in On Position Flame Adjustment Knob oj REMOTE Remote Selector Switch in Remote Position Figure 23 Setting the Remote Selector Switch Control Knob and Flame Adjustment Knob for Remote Operation Note The GHRCT receiver and hand held remote control must be purchased separately see Accessories page 30 Follow instructions included with the remote control 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjustment knob anywhere between HI and LO Slide the remote selector switch to the REMOTE position The burners will come on You can now turn the burners on and off with the hand held remote control unit IMPORTANT Do not leave the remote selector switch in the REMOTE or ON position when the pilot is not lit This will drain the battery 2 Select the MANUAL or AUTO button on the hand held remote control unit In MANUAL mode turn burners on or off by pressing the ON or OFF buttons on the hand held remote c
11. AT HIGH POSITION Figure 27 Correct Front Burner Flame Pattern Yellow _ _ Tipping At Top of Blue Flame INCORRECT FLAME PATTERN AT HIGH POSITION Figure 28 Incorrect Front Burner Flame Pattern If front burner flame pattern is incorrect as shown in Figure 28 e turn heater off see To Turn Off Gas to Appliance page 20 e see Troubleshooting pages 23 through 25 103448 CLEANING AND A WARNING MAINTENANCE Turn off heater and let cool before cleaning A CAUTION You must keep control areas burners and circulating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessive lint from carpet ing bedding material etc ODS PILOT AND BURNERS e Use a vacuum cleaner or small soft bristled brush to clean LOGS e If you remove logs for cleaning refer to Installing Logs pages 17 and 18 to properly replace logs e Replace log s if broken or chipped dime sized or larger TROUBLE A WARNING SHOOTING Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater Note All troubleshooting items are listed in order of operation A CAUTION Never use a wire needle or similar object to clean ODS pilot This can damage ODS pilot unit OBSERVED PROBLEM POSSIB
12. CHECKING GAS CONNECTIONS A WARNING Test all gas piping and connections for leaks after installing or servicing Correct all leaks at once A WARNING Never use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all leaks at once A CAUTION Make sure external regulator has been installed between propane supply and heater See guidelines under Connecting to Gas Supply page 14 Continued 15 103448 INSTALLING Continued Pressure Testing gas Supply Piping system Test Pressures In Excess Of 1 2 PSIG l Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 5 6 Pressurize supply piping system by either using compressed air or Opening propane supply tank valve Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak Correct all leaks at once Re connect heater and manual shutoff valve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG l 2 3 4 Close manual shutoff valve see Figure 14 Pressurize supply piping system by either using compressed air or opening propane supply tank valve
13. Switch in OFF Position Figure 21 Control Knob and Ignitor Button Location 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 6 Press in and turn control knob counterclockwise y to the PILOT position Press in control knob for five 5 seconds see above Note You may be running this heater for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds or less This will allow air to bleed from the gas system 7 With control knob pressed in press and release ignitor button This will light pilot The pilot is attached to the front burner If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure on page 20 Continued 19 9 103448 OPERATING HEATER Continued 8 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob e If control knob does not pop out when released contact a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 Pilot Burner Ignitor Electrode Figure 22 Pilot 9 Sli
14. The information on pages 5 through 7 will help you classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventila tion However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm 6x10 per pa sec m or less with openings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings If your home meets all of the three criteria above you must provide additional fresh air See Ventilation Air From Outdoors page 7 If your home does not meet all of the three criteria above continue reading Confined Unconfined Space The National Fuel Gas Code ANSIZ223 1 1992 Section 5 3 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic fe
15. e purchase date Usually we will ask you to return the defective part to the factory Parts Not Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA International s Parts Department at 1 800 972 7879 for referral information When calling DESA International have ready e model number of your heater e the replacement part number 103448 ILLUSTRATED PARTS BREAKDOWN Variable Control Model VS18PR VS24PR VS30PR 103448 PARTS LIST Variable Control Model KEY NO 1L This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 30 of this manual PART NUMBERS VS18PR VS24PR VS30PR 103580 04 103576 01 103577 02 103578 02 103579 02 M11084 26 103778 01 098249 01 103780 01 101330 04 101008 01 101007 01 100999 02 103984 01 098271 06 102445 01 103588 01 103782 01 M12461 26 103781 02 097264 02 103784 02 103784 01 103587 01CK M11084 26 103284 02 099387 09 101004 10 101004 10 103783 01 099998 01 100563 01 103877 01 100565 01 100639 01 101137 02 101416 27 GA6060 103580 01 103580 02 103576 02 103577 01 103578 01 103579 01 M11084 26 103778 01 098249 01 103780 01 101330 05 101008 01 101007 01 100999 02 103984 02 098271 06 102445 01 103588 01 103782 01 M12461 26 103781 02 098264 02 103784 02 103784 01
16. leak See Warning state ment above 1 Open window to ventilate room Stop using odor causing products while heater is running 2 Refill supply tank 3 Locate and correct all leaks see Checking Gas Connections page 15 Heater shuts off in use ODS operates 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventila tion 2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 23 Gas odor even when control knob is in OFF position 1 Gas leak See Warning state ment above 2 Gas control defective 1 Locate and correct all leaks see Checking Gas Connections page 15 2 Replace gas control Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning state ment above 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Connections page 15 Log set cycles to pilot but room temperature drops to a lower than ideal level before log set comes back on 1 Hand held remote control unit needs to be moved away from heater 1 Move hand held remote control unit farther away from the heater 103448 SPECIFICATIONS 18 Variable 24 Variable 30 Variable Btu Variable 16 000 26 000 20 000 33 000 21 500 36 000 Type Gas Propane Only Propane Only Propane Only Ignition Piezo Pie
17. not supply these accessories call DESA International s Parts Department at 1 800 972 7879 for referral information You can also write to the address listed on the back page of this manual MANUAL SHUTOFF VALVE GA5010 For all models Manual shutoff valve with 1 8 NPT tap Fits 1 2 NPT pipe BLACK FIREPLACE HOOD GA6050 For all models Helps deflect heat away from mantel or wall above fireplace BRASS FIREPLACE HOOD GA6052 For all models Helps deflect heat away from Ses mantel or wall above fireplace LAVA ROCK GA6060 For all models Order when additional rock is desired 3 1b bag RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT GHRCT For all models Allows the gas log heater to be operated in a manually or thermostatically controlled mode You can turn the gas log heater on and off without ever leaving the comfort of your easy chair RECEIVER AND HAND HELD REMOTE CONTROL KIT GHRC For all models Allows the gas log heater to be turned on and off by using a hand held remote control WALL MOUNT ON OFF SWITCH GWMS2 For all models Allows the gas log heater to be turned on and off with a wall switch WALL MOUNT THERMOSTAT SWITCH GWMS1 For all models The desired comfort setting can be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected 103448 NOTES
18. that vary from state to state For information about this warranty write DI S A INTERNATIONAL 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 103448 01 Rev B 05 97
19. LE CAUSE REMEDY When ignitor button is 1 Ignitor electrode not connected 1 Reconnect ignitor cable pressed there is no spark to ignitor cable at ODS pilot 2 Ignitor cable pinched or wet 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Piezo ignitor nut is loose 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Broken ignitor cable 4 Replace ignitor cable 5 Bad piezo ignitor 5 Replace piezo ignitor 6 Ignitor electrode positioned 6 Replace ignitor wrong 7 Ignitor electrode broken 7 Replace ignitor When ignitor button is 1 Gas supply turned off or 1 Turn on gas supply or open manual pressed there is spark at manual shutoff valve closed shutoff valve ODS pilot but no ignition 2 Control knob not in PILOT 2 Turn control knob to PILOT position position 3 Control knob not pressed in 3 Press in control knob while in PILOT while in PILOT position position 4 Air in gas lines when installed 4 Continue holding down control knob Repeat igniting operation until air is removed 5 Depleted gas supply 5 Contact local propane LP gas company 6 ODS pilot is clogged 6 Clean ODS pilot see Cleaning and Maintenance above or replace ODS pilot assembly 7 Gas control setting is not correct 7 Replace gas control Continued 103448 TROUBLE SHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY ODS pilot lights
20. ake sure you have the items listed below e external regulator supplied by installer see e test gauge connection Figure 12 e sediment trap e piping check local codes e tee joint e sealant resistant to LP gas e pipe wrench e manual shutoff valve An A G A design certified manual shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional A G A design certified manual shutoff valve from your dealer See Accessories page 30 The installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 inches of water If you do not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing rain or sleet Propane Supply Tank External Regulator Vent Pointing Down Figure 12 External Regulator With Vent Pointing Down A WARNING Never connect heater to private non utility gas wells This gas is commonly known as wellhead gas A CAUTION Use only new black iron or steel pipe Internally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur 103448
21. but flame goes out when control knob is released 1 Control knob not fully pressed in 2 Control knob not pressed in long enough 3 Manual shutoff valve not fully open 4 Pilot flame not touching thermo couple which allows thermo couple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 5 Thermocouple connection loose at control valve 6 Thermocouple damaged 7 Gas control damaged 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in 30 seconds 3 Fully open manual shut off valve 4 A Contact local propane gas company B Clean ODS pilot see Cleaning and Maintenance page 23 or replace ODS pilot assembly 5 Hand tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace gas control One or both burners do not light after ODS pilot is lit 1 Inlet gas pressure is too low 2 Burner orifice s clogged 3 Mislocated crossover tube 4 Burner orifice s diameter is too small 5 Remote selector in OFF position 6 Wire disconnected from gas control 1 Contact local propane LP gas company 2 Clean burner s see Cleaning and Maintenance page 23 or replace burner orifice s 3 Contact qualified service person 4 Replace burner orifice s 5 Put remote selectorin ON position 6 See Wiring Diagram page 26 Delayed ignition o
22. d space You will need no additional fresh air ventilation 103448 103448 AIR FOR COMBUSTION AND VENTILATION Continued A WARNING If the area in which the heater may be operated is smaller than that defined as an uncon fined space provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code ANSI 2223 1 1992 Section 5 3 VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining uncon fined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options and 2 Figure 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANSI 2223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts A WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces WS SSS SSS Ventilation if Grills Ventilation Grills Into Adjoining Or Into Adjoining Room Bice Remove Option 2 pron Door into Adjoining Room Option 3 N ja Figure 2 Ventilation Air from Inside Building Ventilation Air From Outdoors
23. e Control Kit see Accessories page 30 before installing gas log heater See installation instructions included with the kit 1 Apply pipe joint sealant lightly to male threads of gas fitting Connect approved flexible gas hose to inlet side of gas control see Figure 10 2 Position heater base assembly in fireplace W Mark screw locations through holes in front panel of base see Figure 11 If installing in a brick bottom fireplace mark screw locations in mortar joint of bricks Remove heater base from fireplace Drill holes at marked locations using 3 16 masonary drill bit Attach base to fireplace floor using masonry screws in hardware package NWN WN Ff Connect to gas supply See Connecting To Gas Supply page 14 Gas Control Flexible Gas Hose if allowed by local codes Figure 10 Attaching Flexible Gas Hose to Heater Gas Regulator gt 6 A Masonry Screw Masonry Screw Figure 11 Attaching Base to Fireplace Floor Continued 13 103448 INSTALLING Continued CONNECTING TO GAS SUPPLY NOTICE A qualified service person must connect heater to gas supply Follow all local codes A CAUTION Never connect heater directly to the propane supply This heater requires an external regulator not supplied Install the external regulator between the heater and propane supply Installation Items Needed Before installing heater m
24. een selected F Figure 24 GHRCT Thermostat Hand Held Remote Control Unit Selections 103448 INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often PILOT FLAME PATTERN Figure 25 shows a correct pilot flame pattern Figure 26 shows an incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down Thermocouple Pilot Burner Thermocouple Pilot NOD ae P Figure 25 Correct Pilot Flame Pattern Figure 26 Incorrect Pilot Flame Pattern If pilot flame pattern is incorrect as shown in Figure 26 turn heater off see To Turn Off Gas to Appliance page 20 e see Troubleshooting pages 23 through 25 FRONT BURNER FLAME PATTERN Figure 27 shows correct front burner flame pattern Figure 28 shows incorrect front burner flame pattern The incorrect burner flame pattern shows yellow tipping at top of blue flame A WARNING If yellow tipping occurs your heater could produce increased levels of carbon monoxide If front burner flame pattern shows yellow tipping follow instructions at bottom of this page Yellow flame on rear burner is normal NOTICE Do not mistake orange flames with yellow tipping Dirt or other fine particles are burned by heater causing brief patches of orange flame exten CORRECT FLAME PATTERN
25. en 8 and 12 above A WARNING Non combustible material must extend 8 above the fireplace opening 103448 INSTALLING Continued Mantel Clearances If you meet minimum clearance between mantel shelf and top of fireplace opening a hood is not required see Figure 6 Mantel Shelf Underside of Mantel Shelf All minimum distances are in inches A 12 20 2412 2712 30 TUS To Of Fireplace e Opening Minimum Non Distances to Combustible Underside of Material Height Mantel Minimum Non gt Combustible Material Figure 6 Minimum Mantel Clearances Without Using Hood If above minimum clearances are not met you must have a hood Follow minimum clearances shown in Figure 7 when using hood Mantel Shelf Underside of Mantel Shelf All minimum distances are in inches Minimum Non gt Combustible Material 3 12 15 18 20 E eee Top of Fireplace WS Opening Distances to GA6050 GA6052 Underside of Mantel Figure 7 Minimum Mantel Clearances When Using Hood If your installation does not meet the above minimum clearances you must e raise the mantel to an acceptable height OR e remove the mantel 103448 Continued INSTALLING Continued Floor Clearances A If installing appliance on the floor level you must maintain the minimum distance of 14 to combus tibles see Figure 8 Combustible 14 Ma
26. et per 1 000 Btu per hour 4 8 m per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them Continued 103448 AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height cu ft volume of space Example Space size 20 ft length x 16 ft width x 8 ft ceiling height 2560 cu ft volume of space If additional ventilation to adjoining room is supplied with grills or openings add the volume of these rooms to the total volume of the space 2 Divide the space volume by 50 cubic feet to determine the maximum Btu Hr the space can support volume of space 50 cu ft Maximum Btu Hr the space can support Example 2560 cu ft volume of space 50 cu ft 51 2 or 51 200 maximum Btu Hr the space can supp
27. f one or both burners 1 Manifold pressure is too low 2 Burner orifice s clogged 3 Mislocated crossover tube 1 Contact local propane LP gas company 2 Clean burner s see Cleaning and Maintenance page 23 or replace burner orifice s 3 Contact qualified service person Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas control defective 1 Clean burner see Cleaning and Maintenance page 23 or replace burner orifice 2 Replace damaged burner 3 Replace gas control Yellow flame in front burner during burner combustion 1 Not enough air 2 Gas control defective 1 Check burner s for dirt and debris If found clean burner s see Cleaning and Maintenance page 23 2 Replace gas control Slight smoke or odor during initial operation 1 Residues from manufacturing processes and logs curing 1 Problem will stop after a few hours of operation Moisture condensation noticed on windows 1 Not enough combustion ventilation air 1 Refer to Air for Combustion and Ventilation requirements page 5 103448 TROUBLE SHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Heater produces a whistling noise when burners are lit 1 Turning control knob to HI position when burners are cold 2 Air in gas line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner orifice s
28. fire explosion electrical shock and carbon monoxide poison ing A DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the heater may not be working properly Get fresh air at once Have heater serviced Some people are more affected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Propane Gas Propane gas is odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you read and understand all Warnings Keep this manual for reference It is your guide to safe and proper operation of this heater Safety Information continues on next page 103448 SAFETY A WARNINGS Continued INFORMATION WARNING Any change to this heater or its controls can be dangerous Continued 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases 2 Do not place propane supply tank s inside any structure Locate propane supply tank s outdoors 3 If you smell gas e shut off gas supply e do not try to light any appliance e d
29. ghtly push in and turn control knob counterclockwise y to the ON position 10 Wait one minute and switch remote selector switch to the ON position to light burner 11 Set flame adjustment knob to any level between HI and LO A CAUTION Do not try to adjust heating levels by using the manual shutoff valve A WARNING Make sure the remote selector switch is in the OFF position when you are away from home for long periods of time Heater will come on automatically with remote selector switch in the ON position ESS TO TURN OFF GASTO APPLIANCE P Shutting Off Heater 1 Turn control knob clockwise to the OFF position 2 Set remote selector switch in the OFF position to prevent draining battery Shutting Off Burners Only pilot stays lit You may shut off the burners and keep the pilot lit by doing one of the following e Turn control knob clockwise A to the PILOT position e Use remote control manual OFF button e Set remote selector switch in the OFF position E HERmMosTATcontROL operation M The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO The Burners will turn on and off automatically to maintain the comfort level you select The ideal comfort setting will vary by household depending upon the amount of space to be heated the output of the central heating system etc D ANUAL LIGHTING PROCEDURE M 1 Follow steps 1 through 6 under Lighting Instructions
30. hes batteries or other sources to light heater 103448 AIR FOR COMBUSTION AND VENTILATION A WARNING This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air Read the following instructions to insure proper fresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from the house to operate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following is exerpts from National Fuel Gas Code NFPA 54 ANSI 2223 1 Section 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Contruction 2 Unconfined Space 3 Confined Space
31. ing to Gas Supply s iscicccesecdeso cesecd shoes seak on EEEE AEE E EEEE EEE EEEE 14 Checking Gas Connections ssiciscssesssatesvses cases riire EEE E E EE E tied co ETEN a 15 Tnnstallinn S10 88 ses secs ic sect irreais ea ieke totus date iro ees E AE EEE EE E E EES 16 Operating Tate hz seccsces ceeds rnes ee soe satus neies ee aree OEE Sones Sous E OE ENEE ER SE e SEET sep EE 17 Inspecting BONETS sennen taea r E E E EE AE E E E 22 Cleaning and Maintenance 00 sinoni sineren s ree cresnes oer rssint isror eeso esre Peress retien rotit sr arot 23 Troublesh otin Ess ieie e nira o EE ote sabes EEE A E EE EEE E Sule E EE EEE EEOSE 23 SPCC CALL ONS vegen ia erron SEE AREER E EE E N EEEE E EE AE EAE N NEEE 26 Wiring Dia grain 5ssessess esrtis nacese t i taria poreo oaea eiaa E ETE EEEE EEE EE oE SS oR ENE S 26 Technical Service nenene aes tens E E teenies EA a R oe te E E 26 Service Hints usscsnarsnd anena E a EA ea eE ca dunce E E a Aa EA aS i Eiei 26 Replacement Parts oerna nna ee E A Eae a E E S SERA e E TEE 27 Ilustrated Parts Lists reon esn aA E egos E AE A a aE EEE 28 29 IN CCESSOTIES ei ced vn Ses AEREE E EE EA AA FREE rE N AOE ERTER 30 Warranty Information eers ioc cig Biases o E EERE EE E E E EE eE E EE EEE EE EEES Back Cover A WARNINGS IMPORTANT Read this owner s manual carefully and completely before trying to as semble operate or service this heater Improper use of this heater can cause serious injury or death from burns
32. ith heater 1 Place front logs 1L and 1R on top of the grate Make sure the notches in the bottom of the logs fit over the grate prongs see Figure 16 Push back of logs flush with metal grate bar Note 18 model has only one front log 2 Rest bottom middle log 2 behind metal posts on front burner Make sure the grooves in the bottom of the log fit over the grate Bring the log forward next to the metal posts The pegs on the log must be on top see Figure 17 3 Slide the grooves in the back of the rear log 3 against the rear grate prongs Make sure the peg on the log is on top see Figure 18 4 Place the top middle log 4 on the bottom middle log 2 Make sure the pegs of the bottom middle log fit securely in the holes of the top middle log see Figure 19 Front Log 1L Peg To Pi Middle Log 2 Groove Figure 16 Installing Front Logs Figure 17 Installing Bottom 1L and 1R Middle Log 2 Groo ve in Back of Log Grate Prong Hole Bottom Middle Log Figure 18 Installing Rear Log 3 Figure 19 Installing Top Log 4 103448 INSTALLING Continued OPERATING HEATER 4 Place the crossover log 5 on the back log and the top middle log Make sure the peg on the rear log is in the hole in the bottom of the crossover log The crossover log should fit in the cutout of the top middle log see Figure 20 ees Crossover Log 4 A Hole Cutout Fig
33. l of fireplace If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper A WARNING Never install the heater in a bedroom or bathroom ina recreational vehicle where curtains furniture clothing or other flammable objects are less than 36 inches from the front top or sides of the heater e in high traffic areas e in windy or drafty areas A CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities in the air such as tobacco smoke exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation pages 5 through 7 CHECK GAS TYPE Use only propane LP gas If your gas supply is not propane LP gas do not install heater Call dealer where you bought heater for proper type heater 103448 INSTALLING INSTALLATION AND CLEARANCES Continued A WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining wall MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size Side Wall Ceiling Floor 1 8 24 30 1 6 42 5
34. nstaller in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MER CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THREE 3 YEARS ON ALL COMPONENTS AND FIVE 5 YEARS ON STAINLESS STEEL BURNERS FROM THE DATE OF FIRST PURCHASE AND DESA INTERNATIONAL S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDI RECT INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages so the above limitation on implied warranties or exclusion or limitation on damages may not apply to you This warranty gives you specific legal rights and you may also have other rights
35. o not touch any electrical switch do not use any phone in your building e immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e if you cannot reach your gas supplier call the fire department This heater shall not be installed in a bedroom or bathroom Never install the heater e in a recreational vehicle e where curtains furniture clothing or other flammable objects are less than 36 inches from the front top or sides of the heater e in high traffic areas e in windy or drafty areas 6 Before installing in a solid fuel burning fireplace the chimney flue and firebox must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage If damaged operate heater with flue damper closed 7 If fireplace has glass doors never operate this heater with glass doors closed If you operate heater with doors closed heat buildup inside fireplace will cause glass to burst Also if fireplace opening has vents at the bottom you must open the vents before operating heater 8 You must operate this heater with a fireplace screen in place Make sure fireplace screen is closed before running heater 9 This log heater is designed to be smokeless If logs ever appear to smoke turn off heater and call a qualified service person Note During initial operation slight smoking may occur due to log curing and heater bu
36. ontrol unit In AUTO mode the room temperature is controlled by the thermostat in the hand held remote control unit To increase the room temperature press the top arrow of the TEMP button To lower room the temperature press the bottom arrow to the TEMP button At higher settings the heater will run more IMPORTANT The hand held remote control unit must be near the heater Do not keep the hand held remote control unit too close the heater The thermostat on the hand held remote control unit will heat up too quickly and turn the heater off 3 Use the STATUS button on the hand held remote control unit to see the operation mode being used and the temperature setting selected A red light will come on beside the operation mode being used when the status button is pressed 4 To turn the burners off when operating in the MANUAL mode press the OFF button If operat ing in the auto mode press the manual button then press the OFF button The pilot will remain lit IMPORTANT To turn the pilot off manually turn the control knob on the heater to the OFF position or set remote selector switch to OFF position Shows Temperature Setting lickassee Adoi Temperature Turns Burners On and Off Shows Current Operation Mode i S a TEMP Allows Burners to be Turned Fle v aeaa T On and Off with the Hand UA Held Remote Unit Lo AUTO The log heater will automatically cycle between pilot and the heat setting that has b
37. or s phone Follow the models gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate Installation and service must be per combustion and ventilation air must be pro formed by a qualified installer service vided Refer to Air for Combustion and Venti agency or the gas supplier lation section in this manual Save this manual for future reference CONTENTS SAFETY INFORMATION SECTION PAGE Safety IMLOMMALOM s sessist irsin cdsdedssssacd soesessqcdasuss sscogdeabsssecudevshs SETAST ESEESE EEIE RE SES aS Ee SERES E Es 2 Product Id ntification setene e Ea E a i E E A EE OE E 4 Local Codes traii nten anea a A E EE Da AA E aA ETA E EE 4 Unpacking sc secssucsssescadesthassstasschassastddctbschages areae secapast rE aE Ee Esae E ESEE seuss sgelvsessapveetys suseoseabassas 4 Prod ct Features mennene oriee an E N A ei ann an hile 4 Air for Combustion and Ventilation ccesesessccescesseceseeceecesseceeeeceaeeesceseneecaeceeeeceeeesaeceaeeee 5 Wins teal a YEE E AE E AES EEE ede epoucen Sots caves sorted E EEEE 8 Check Gas TYPE orisirisi eop rea oen EEEa EEE E EE E ES E states EEE E 8 Installation and Clearances ie ivesccccscc ses niu inn na ia cs tv cus a a esa Ra 9 Installing Heater Base Assembly ireira ea a kai iai 12 Connect
38. ort 3 Add the Btu Hr of all fuel burning appliances in the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Example Gas water heater 40 000 Btu Hr Vent free heater 33 000 Btu Hr Total 73 000 Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used Btu Hr maximum the space can support Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 73 000 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space because the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between rooms See Ventilation Air From Inside Building page 7 B Vent room directly to the outdoors See Ventilation Air From Outdoors page 7 C Install a lower Btu Hr heater if lower Btu Hr size makes room unconfined If the actual Btu Hr used is less than the maximum Btu Hr the space can support the space is an uncon fine
39. r water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water 19 Do not operate heater if any log is broken Do not operate heater if a log is chipped dime sized or larger 20 Turn heater off and let cool before servicing installing or repairing When using the hand held remote accessory make sure the remote selector switch is in the OFF position Only a qualified service person should install service or repair heater 21 When using the hand held remote accessory make sure the remote selector switch is in the OFF position when you are away from home for long periods of time 22 This heater must not be connected to any external electrical source 23 Operating heater above elevations of 4 500 feet may cause pilot outage 24 To prevent performance problems the use of a propane fuel tank of less than 100 Ib capacity is not recommended ue 103448 PRODUCT IDENTIFICATION LOCAL CODES UNPACKING PRODUCT FEATURES Crossover Log Top Middle D MEA Log Left XS Front Branch Front Burner Sy y ee Aa PS J Rear WS Burner Piezo ignitor lt N Bottom Middle Log _sS ae ell Right Front ONS p NOSSA AN i A Remote Branch G SA LLI Control Control Knob Base Optional Flame pN R Assembly bs eei Remote no Selector Switch Optional Fig
40. rning manufacturing residues 10 Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans may create drafts that alter burner flame patterns Altered burner patterns can cause sooting 11 Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater 12 This heater needs fresh outside air ventilation to run properly This heater has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 5 through 7 If heater keeps shutting off see Troubleshooting pages 23 through 25 13 Do not run heater e where flammable liquids or vapors are used or stored e under dusty conditions 14 Do not use this heater to cook food or burn paper or other objects 15 Never place any objects on the heater 16 Heater base assembly becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shutpdown Allow surface to cool before touching 17 Carefully supervise young children when they are in the room with heater When using the hand held remote accessory keep remote selector switch in the OFF position to prevent children from turning on burners with hand held remote control unit 18 Do not use heater if any part has been exposed to or unde
41. ss doors never operate this heater with glass doors closed If you operate heater with doors closed heat buildup inside fireplace will cause glass to burst Also if fireplace opening has vents at the bottom you must open the vents before operat ing heater You must operate this heater with a fireplace screen in place Make sure fireplace screen is closed before running heater NOTICE During initial operation of new heater burning logs will give off a paper burning smell Orange flame will also be present Open damper or window to vent smell This will only last a few hours Note Homeowners generally prefer to operate their heater with the chimney damper closed This will put all the heat into the room However there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive You can open the chimney damper if you have one fully or partially to release some of the heat WARNING Damper handle will be hot if heater has been running 1 STOP Read the safety information above 2 Make sure manual shutoff valve is fully open 3 Set remote selector switch in the OFF position A WARNING Burners will come on automatically within one minute when the remote selector switch is in the ON position 4 Press in and turn control knob clockwise AZN to the OFF position Control Knob Knob Flame Adjustment Knob O mor ned Ignitor Button Selector
42. terial Non Combustible Material Figure 8 Minimum Fireplace Clearances If Installed at Floor Level B If combustible materials are less than 14 to the fireplace you must install appliance at least 5 above the combustible flooring see Figure 9 Hearth A Combustible J Material 5 Min Figure 9 Minimum Fireplace Clearances Above Combustible Flooring INSTALLING HEATER BASE ASSEMBLY A WARNING You must secure this heater to fireplace floor If not heater will move when you adjust controls Moving heater may cause a gas leak A WARNING If installing in a sunken fireplace special care is needed You must raise the fireplace floor to allow access to heater control panel This will insure adequate air flow and guard against sooting Raise fireplace floor with non combustible material Make sure material is secure A CAUTION Do not pick up heater base assembly by burners This could damage heater Only handle base assembly by grates IMPORTANT Make sure the heater burners are level If heater is not level heater will not work properly 103448 INSTALLING Installation Items Needed Continued hardware package provided with heater e approved flexible gas hose not provided if allowed by local codes e sealant resistant to propane LP gas not provided e electric drill with 3 16 drill bit Note Install optional GHRCT Receiver and Hand Held Remot
43. ure 1 VS24PR Shown Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSI Z223 also known as NFPA 54 Available from American National Standards Institute Inc National Fire Protection Association Inc 1430 Broadway Batterymarch Park New York NY 10018 Quincy MA 02269 Note Where listed vented decorative logs are required thermostat operation is not permitted 1 Remove logs and heater base assembly from carton Note Do not pick up heater base assembly by burners This could damage heater Always handle base assembly by grate 2 Remove all protective packaging applied to logs and heater for shipment 3 Check all items for any shipping damage If damaged promptly inform dealer where you bought heater Operation This heater is clean burning It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by both realistic flames and glowing coals This heater is designed for vent free operation with flue damper closed State and local codes in some areas prohibit the use of vent free heaters Safety Pilot This heater has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The ODS pilot is a required feature for vent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air Piezo Ignition System This heater has a piezo ignitor This system requires no matc
44. ure 20 Installing Crossover Log 5 GE FOR YOUR SAFETY READ BEFORE LIGHTING M A WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance Do not touch any electric switch do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 103448 OPERATING HEATER Continued EE LIGHTING INSTRUCTIONS ia A WARNING If fireplace has gla
45. zo Piezo Pressure Manifold 7 9 W C 7 9 W C 7 9 W C Inlet Gas Pressure in of water Maximum 14 14 14 Minimum 11 11 11 For purpose of input adjustment Shipping Weight 32 lbs 34 Ibs 36 Ibs WIRING On DIAGRAM Off Switch Auto TPTH TH You may have further questions about installation operation or troubleshooting If so contact DESA y q p g SERVICE International s Technical Service Department at 1 800 DESA LOG 1 800 337 2564 Gas Control TPTH TP SERVICE HINTS When gas pressure is too low e pilot will not stay lit e burners will have delayed ignition e heater will not produce specified heat e propane LP gas supply may be low When gas quality is bad e pilot will not stay lit e burners will produce flames and soot e heater will backfire when lit You may feel your gas pressure is too low or gas quality is bad If so contact your local propane LP gas supplier 103448 REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA International s Technical Service Department at 1 800 323 5190 When calling DESA International have ready e your name e your address e model number of your heater e how heater was malfunctioning e type of gas used propane or natural gas