Home
Texas Instruments ZIGBEE SWRU157D User's Manual
Contents
1. 00 21 1c 00 00 15 31 16 0A 46 87 70 79 01 00 02 00 14 17 00 00 15 31 17 OA 46 87 6f 79 01 00 02 00 14 1e 00 00 Playback is done in two steps e Open a log file using the button This will active the O button e Click on the O button to start the playback During playback the network view background will differ from when capturing data online The figure below is an example of playing back already recorded data 10 j de ZigBee Sensor Monitor 1 2 0 E O x 000 nm Pon comiy YO 420 000 4 4 Help The User s Manual is a file which opens when the help button Y is clicked The About button can be clicked to obtain information about the application 4 5 Configuration Click on the Configuration button and the settings dialog will appear 11 Configuration settings Temperature Unit e Celsius Fahrenheit Time interval for Mode removal 20 Sec Temperature unit Celsius or Fahrenheit can be selected Time interval The timestamp of each node will be checked regularly to see if any message has been received within the given time interval If the elapsed time is longer than specified the Node will be removed from the screen 12 4 6 Network View The PC demo will always display one node on the top of the screen the Sink Below the Sink the presence of additional network nodes will be displayed as they are detected Be aware that nodes may place themselves on top of existin
2. a license from a third party under the patents or other intellectual property of the third party or a license from TI under the patents or other intellectual property of TI Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties conditions limitations and notices Reproduction of this information with alteration is an unfair and deceptive business practice Tl is not responsible or liable for such altered documentation Information of third parties may be subject to additional restrictions Resale of Tl products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice Tl is not responsible or liable for any such statements Tl products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have executed an agreement specifically governing such use Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications and acknowledge and agree that they are solely responsible for all legal regulatory and safety related requirements concerning t
3. installation are available The PC application will communicate with the eZ430 RF2480 dongle over a virtual COM port The first time the dongle is connected to the PC the new HW will be detected and the wizard will appear and ask to install the necessary software The required inf file will be installed when installing the PC application Please follow the guidelines in this section based on your PC s operating system 3 1 Windows XP Found New Hardware Wizard Welcome to the Found New When the dialog box appears select Hardware Wizard a s No not this time and Click next Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows connect to Windows Update to search for software O Yes this time only O Yes now and every time connect a device Click Next to continue Found New Hardware Wizard Select Install the software automatically and click next This wizard helps you install software for MSP430 Application UART If your hardware came with an installation CD lt 6 or floppy disk insert it now What do you want the wizard to do Install from a list or specific location Advanced Click Next to continue Found New Hardware Wizard Please select the best match for your hardware from the list below SE If the IAR kickstart f
4. ABLE TO START THE APPLICATION A dde ira 17 DOCUMENT IIS TOKYO S 18 1 Introduction ZigBee Sensor Monitor or ZSensorMonitor is a PC application that will be used to monitor the sensors in a ZigBee Network ZSensorMonitor can be used together with either the CC2530ZDK or an eZ430 RF2480 kit The network is formed when setting up the basic out of the box demo included either of the kits In the case of eZ430 RF2480 this includes the ZigBee Accelerator Sample Application This document will only describe the user interface of the ZSensorDemo PC application 1 1 CC2530ZDK Further details about the CC2530ZDK and the Sensor Demo sample application can be found on the CC2530ZDK website www ti com cc2530zdk 1 2 ez430 RF2480 Further details about the hardware platform and the ZigBee Accelerator Sample Application ZASA can be found on the eZ430 RF2480 Demo kit website at www ti com eZ430 RF2480 Formerly known as eZ430 RF2480 Sensor Monitor 2 Installation The installation of ZSensorMonitor is very straight forward Download the zip file from internet and unzip the setup file Double click on the setup file and follow the instructions 3 eZz430 RF2480 Driver Installation This section is only relevant if the eZ430 RF2480 kit platform is used Note When using eZ430 RF2480 the PC application should be installed before the eZ430 RF2480 dongle is connected to the PC This is to be sure that the required files for the driver
5. a ZigBee Coordinator Routers and End Devices where the Coordinator is operating as a data Sink and all remaining devices are operating as data Sources ZigBee Sensor Monitor 20 a ES i E A A LE 2 A d ommi I oh AAA 4 1 Toolbar mis ZigBee Sensor Monitor 1 2 0 Communications Port COMM N Drop down list with all the available COM ports Stop capturing data from Refresh list of serial the serial COM port COM ports Pause capturing data from Start logging to the serial COM port file Open log file for Start capturing data D playback the serial COM port Configuration Open application user manual About information The list of available COM ports will automatically be updated when the eZ430 RF2480 dongle is connected or disconnected It is also possible to force refresh of the list by clicking on the green refresh button av Start playback of log file 4 2 Data capture If the applicable COM port can be found when refresh has been clicked the application will automatically try to capture data from the COM port If communication is successfully established the capture button will be disabled and both the Pause capture button Dana the Stop capture button Q will be enabled If more than one device with the applicable COM port is connected to the PC it could be that wrong COM port gets selecte
6. d In this case the first port in the list will be selected If this was not the intended device to connect to the appropriate COM port must be selected manually Using the Stop capture button will cause the nodes on display to be removed from the screen once the Start capture button is clicked This differs from the Pause capture button which will maintain the nodes on the screen when the Start capture button is clicked 4 3 Data logging and playback It is possible to capture the data traffic on the serial port to a log file for debugging and playback purposes The log file is pure ASCII text which displays a time stamp and the raw data in hexadecimal format Data logging is started by clicking the button ca The user will then be requested to provide a file using the standard File Save dialog The log file shown below is a sample ZigBee PRO log file included in the distribution as ZSensorMonitor_pro log 15 30 27 02 61 01 41 00 15 30 45 03 46 82 01 00 58 15 30 45 OA 46 87 01 00 01 00 02 00 le Ic 00 00 15 30 53 03 46 82 6f 79 19 15 30 55 OA 46 87 01 00 01 00 02 00 1f 1c 00 00 15 30 55 OA 46 87 6f 79 01 00 02 00 14 1e 00 00 15 31 03 03 46 82 70 79 19 15 31 04 OA 46 87 70 79 01 00 02 00 14 17 00 00 15 31 05 OA 46 87 01 00 01 00 02 00 20 1c 00 00 15 31 06 OA 46 87 70 79 01 00 02 00 14 17 00 00 15 31 12 03 46 82 71 79 58 15 31 12 OA 46 87 71 79 01 00 02 00 17 1d 00 00 15 31 15 OA 46 87 01 00 01 00 02
7. en the eZ430 RF2480 is removed these device drivers should disappear from the view in the Device Manager If they don t disappear a restart of the PC will be necessary Check that the MSP430 device is available in the drop down list of available COM ports 16 5 6 Not able to start the application If an error message about missing the msvcp80 dll is received or the error message shown below appears when attempting to start the application you may be required to install an additional package from Microsoft The package contains some additional runtime components needed by applications developed with Visual C To resolve this problem install the package by running the file vcredist_x86 exe file found in the folder vcredist of the ZSensorMonitor installation Alternatively the package can be downloaded from the web http www microsoft com downloads details aspx familyid 9B2DA534 3E03 4391 8A4D 074B9F2BC1BF amp displaylang en 17 Document History Revision ate BesoriptiowChanges 08 03 2008 Initial release Added logging and playback Changed document name swul 08 05 2009 Added support for CC2530 Z Stack Sensor Demo Added status bar swru157d 25 08 2009 Changed document title 18 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries Tl reserve the right to make corrections modifications enhancements improvements and other changes to its products and services at any time and
8. g nodes when they first appear but can easily be dragged away with the mouse The various states of the nodes are described below Sink node not connected to the PC An attempt to read from the COM port has been made but no response received Sink node connected to the PC but reading from the COM port is not active Sink node connected to the PC and reading from the COM port The difference with a Sink not connected to the PC can be seen from the black and white outline Y a A combined router and source node in the network The short address temperature voltage and a timestamp is shown within the node The timestamp is from the last message received from the node The node will blink each time a message is received by the connected Sink node A dummy router If we don t receive any message from a router within the configured time interval it can be assumed that the node is out of service However if the node has child nodes that are still alive the node will not be removed it will be changed to a dummy router Source node with information about the short address temperature Only applicable for the eZ430 RF2480 13 voltage and a timestamp from when the last message was received from this node The source node will blink each time a message is received by the connected Sink node The role of each node is also indicated if the mouse is held over the node for more than a second T
9. he nodes are connected with arrows to show the relationship between parent and child nodes based on the CSKIP addressing scheme This relationship is with respect to addressing and does not necessarily reflect the path taken for routing messages between a source and the sink 4 6 1 Zoom The user can zoom in and out of the network view by using the wheel on the mouse or by clicking on the or buttons The focus for zooming in and out will be based on the location of the mouse pointer 4 6 2 Scroll bars The Horizontal and Vertical scroll bars can be used to navigate the network lf the Network view is zoomed out far enough to make the outline of the rectangular background visible the scroll bar will disappear 4 6 3 Moving a Node The nodes can be moved around with the mouse To move a node click and hold the left mouse button while pointing to the node Hold the left mouse button and drag the node to the required position Release the left mouse button when the node is in the desired position 4 6 4 Removal of a Node A node will be removed from the screen if no message has been received within the time interval given in the settings dialog 4 7 Status bar The status bar shows the status of the application connection state mode of operation serial port traffic statistics and protocol information PLAYBACK Collecting data Packets 21 Last packet 15 31 04 Profile ZigBee PRO gt Applies only t
10. heir products and any use of TI products in such safety critical applications notwithstanding any applications related information or support that may be provided by TI Further Buyers must fully indemnify Tl and its representatives against any damages arising out of the use of TI products in such safety critical applications Tl products are neither designed nor intended for use in military aerospace applications or environments unless the TI products are specifically designated by Tl as military grade or enhanced plastic Only products designated by TI as military grade meet military specifications Buyers acknowledge and agree that any such use of TI products which TI has not designated as military grade is solely at the Buyer s risk and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use Tl products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO TS 16949 requirements Buyers acknowledge and agree that if they use any non designated products in automotive applications Tl will not be responsible for any failure to meet such requirements Following are URLs where you can obtain information on other Texas Instruments products and application solutions Products Applications Amplifiers amplifier ti com Audio www ti com audio Data Converters dataconverter ti com Automo
11. nded to first start the PC application and then to plug in the eZ430 RF2480 dongle It is also possible to manually select the COM port from the drop down list Search for device starting with MSP430 and select this one Then push the capture button to establish the communication If still no success it is time to check the device in the device manager If the device drivers have been successfully installed there should be one Composite USB device and one serial COM port Correctly installed devices should look like the screen shot below 15 Es Device Manager File Action View Help E8 Dell Wireless 1390 WLAN Mini Card PCMCIA adapters Ports COM amp LPT a AEE Port COM1 The serial COM port 24 Toshiba BT Port COM11 24 Toshiba BT Port COM12 24 Toshiba BT Port COM13 24 Toshiba BT Port COM14 24 Toshiba BT Port COMZ0 24 Toshiba BT Port COM21 24 Toshiba BT Port COME 4 Toshiba BT Port COM e Processors a Smart card readers sound video and game controllers A System devices Universal Serial Bus controllers Dell Wireless 350 Bluetooth Internal Card Generic USE Hub Generic USE Hub Generic USE Hub Intel R 828016 ICH Family USB Universal Host Controller 2708 Intel R 828016 ICH Family USB Universal Host Controller 279 Intel R 828016 ICH Family USB Unive a 828016 ICH Farnily USB Unive nb Family 4562 Enhanced Host Controller aa Wh
12. o the ZigBee 2006 protocol used in eZ430 RF2480 14 5 Troubleshooting 5 1 Incorrect temperature values lf the temperature is much different from the expected value this is because the temperature sensor is not calibrated 5 2 Status of the connected dongle NB This section only applies to the eZ430 RF2480 It is possible for the status of the connected dongle to get out of synchronization if the dongle gets disconnected and connected rapidly without any delay in between In this case the start stop capturing data should be used manually to get the capture operational again 5 3 More than one dongle connected to the PC NB This section only applies to the eZ430 RF2480 lf more than one dongle is connected to the PC make sure that the correct dongle is selected in the list of COM ports 5 4 Connect Disconnect other USB device on same PC NB This section only applies to the eZ430 RF2480 lf any USB device is connected or disconnected while the eZ430 RF2480 dongle is connected and Capture data is active the capture of data could get deactivated In this case the Capture must be re activated manually 5 5 USB dongle not automatically detected when connected NB This section only applies to the eZ430 RF2480 If the eZ430 RF2480 dongle is not automatically detected try to remove the dongle and to connect it again Windows is sometimes slow in detecting a new dongle so don t do this in quick succession It is also recomme
13. or MS P430 has been installed before this E application it might be that this MSP430 Application UART F dialog will pop up and ask the user to select one of the two inf MSP430 Application UAAT Unknown Texas Instruments cando nf oe files Both inf fi les are equal and MSP430 Application UAT Unknown Texas Instruments c andowest in dl It doesn t matter which one that is selected Either should work fine Description Version Manufacturer Location This driver 13 not digitally signed Tell me why driver signing ls importarit Found New Hardware Wizard Please wait while the wizard searches M The installation will start without any further selections MSP430 Application UART Cancel Hardware Installation lf this warning appears the option Sontinue Anyway must be selected in A The software you are installing for this hardware order to install the driver MSP430 Application UART hat not passed Windows Logo testing to verify its compatibility with Windows 4P Tell me why this testing ls important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that haz passed Windows Logo testing Continue Anyway Found New Hardware Wizard This dialog will be shown when Completing the F
14. ound New everything has been successfully Hardware Wizard installed The wizard has finished installing the software for F MSP430 Application UART Click Finish to close the wizard Click Finish to close the wizard 3 2 Windows Vista Windows needs to install driver software for your MSP430 Application UART Locate and install driver software recommended Windows will guide you through the process of installing driver software for your device Ask me again later Windows will ask again the next time you plug in your device or log on Don t show this message again for this device Your device will not function until you install driver software Select I don t have the The first time the USB dongle sink is connected to the PC the new HW is detected and the system will ask to install driver software Select Locate and install driver software disc Show me other Insert the disc that came with your MSP430 Application UART options If you have the disc that came with your device insert it now Windows will automatically search the disc for driver software gt I don t have the disc Show me other options Windows couldn t find driver software for your device Check for a solution Windows will check to see if there are steps you can take to get your device working Browse my computer for driver software advanced Locate and install driver software manually Select Bro
15. tive www ti com automotive DSP dsp ti com Broadband www ti com broadband Clocks and Timers www ti com clocks Digital Control www ti com digitalcontrol Interface interface ti com Medical www ti com medical Logic logic ti com Military www ti com military Power Mgmt power ti com Optical Networking www ti com opticalnetwork Microcontrollers microcontroller ti com Security www ti com security RFID www ti rfid com Telephony www ti com telephony RF IF and ZigBee Solutions www ti com lprf Video amp Imaging www ti com video Wireless www ti com wireless Mailing Address Texas Instruments Post Office Box 655303 Dallas Texas 75265 Copyright 2008 Texas Instruments Incorporated 19
16. to discontinue any product or service without notice Customers shouldobtain the latest relevant information before placing orders and should verify that such information is current and complete All products aresold subject to Tl s terms and conditions of sale supplied at the time of order acknowledgment Tl warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with Tl s standardwarranty Testing and other quality control techniques are used to the extent Tl deems necessary to support this warranty Except wheremandated by government requirements testing of all parameters of each product is not necessarily performed Tl assumes no liability for applications assistance or customer product design Customers are responsible for their products andapplications using TI components To minimize the risks associated with customer products and applications customers should provideadequate design and operating safeguards TI does not warrant or represent that any license either express or implied is granted under any TI patent right copyright mask work right or other TI intellectual property right relating to any combination machine or process in which TI products or services are used Information published by Tl regarding third party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof Use of such information may require
17. vis TEXAS INSTRUMENTS User s Guide ZigBee Sensor Monitor SWRU157D 2008 Low Power RF Contents ZIGBEE SENSOR MONTTOR eee ae ee eee 1 E INTRODUCTION uds 2 1 1 AE ARA sear tect tenet Ne eve AN nT PS ESN NTN BE ir ETN SPE TOR TREN TEE PON ATT RE CE NTE 2 Ls EZASOSR EDAD E ETE N E EE E E A EA ssn Sad ace ee 2 Ze INSTALLATION cion 3 3 EZ430 RF2480 DRIVER INSTALLATION o cocccccccoccoccnccncconcncnoccoconocononocooccccnccnccnoccocnoccnccnccnccnoccneso 3 Jel WINDOWSA P ceraian a a a aa tests 3 See ALI ES A A cE OT Mr ve Oe eT 6 A USER INTERFACE aio 8 4 1 TOOLBAR beet A aaa hase ro A A A 9 4 2 DATA CATRE a e S a do E s 9 4 3 DATA LOGGINGAND PLAYBACK Sua atlas 10 4 4 HEE ooo sd tao wey Ome da ot du tada ooo de 11 4 5 CONFIGURATION an le o ere 11 4 6 NETWORK VIEW nic ironia 13 4 6 1 LOOM AN E A OO 14 4 6 2 VE AIR A 104 e ARA A A A NR A II A A oe EO 14 4 6 3 MOVING O NOUO iS dalla lisis 14 4 6 4 REMOVAL O AAN OC NN 14 4 7 STATUS BAR veg ca ad accio 14 5 TROUBLESHOOTING ai oie 15 5 1 INCORRECT TEMPERATURE VALUES susi rara narra 15 a STATUS OF THE CONNEC IED DONGLE e bes 15 5 3 MORE THAN ONE DONGLE CONNECTED TO THE PC cccecesceccsceccececcsceccscecscscscscusescusescecescs 15 5 4 CONNECT DISCONNECT OTHER USB DEVICE ON SAME PC 0ccecceccecescecceccecescescescecescescesceses 15 5 5 USB DONGLE NOT AUTOMATICALLY DETECTED WHEN CONNECTED cecescececcscescececcscecescececs 15 5 6 INOT
18. wse my computer for driver software The required inf file will be installed together with Browse for driver software on your computer the application Browse to the directory of the Search for driver software in this location application and select Files Texas Instruments eZ430 RFZACC06 Sensor M the sub directory Include subfolders Drivers Click Next to continue x K Windows can t verify the publisher of this driver software Select Install this driver software anyway gt Don t install this driver software You should check your manufacturer s website for updated driver software for your device 2 Install this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information v See details At the end the software should be successfully installed The software for this device has been successfully installed Windows has finished installing the driver software for this device Click Close to end the 7 MSP430 Application UART installation 4 User Interface The user interface is developed to be as simple as possible with only a few buttons and input fields When the eZ430 RF2480 dongle is connected to the PC the application will search for an applicable COM port and start reading if a connection is successfully established Below is a screenshot showing
Download Pdf Manuals
Related Search
Related Contents
Trisa Electronics Fresh Juice HD-SDI User Manual 2003 forester service manual quick reference index engine 2 section Virtu USA GS-6048-CAB-WH Installation Guide Kingston Technology HyperX Memory HyperX 1GB 750MHz DDR2 CL4 Kane 450 combustion flue gas analyser user manual GE 1018959 Network Card User Manual 取扱説明書 Manual de Serviço - Wiki Karat Copyright © All rights reserved.