1. Calibration Function Occasionally the scale s accuracy should be verified by measuring a known weight of the scale s approximate capacity Tare the scale by pressing ZERO SET place the weight on the platform and note the reading Calibrate the scale if necessary Calibration Procedure You must use a 5 Ib or a 2000g calibrated weight ONLY to properly recalibrate the scale 1 Remove any weight from the scale platform 2 Turn the scale on Select the weight unit to be calibrated lb or g 3 Turn the scale off The weight unit selected will be stored in memory 4 Press and hold down the TARE MODE button While holding down TARE MODE also press the ON OFF button The displays shows CAL then zero Release both buttons 5 Press the TARE MODE button The display shows 5 lb or 2000g Place either the calibrated 5 lb or 2000g weight on the platform depending on which weight unit was selected in Step 2 7 Press the TARE MODE button The display shows CAL F if recalibration is successful The scale returns to weighing mode NOTE if the display shows CAL E recalibration was unsuccessful Repeat above steps d Troubleshooting e If there are no items on the platform but the LCD does not show zero press the TARE MODE button to reset the scale to zero e Overload Warning Should Err appear on the display during a weighing this indicates that the maximum w
2. Lo aparecer en la pantalla LCD o si las lecturas pierden intensidad o se vuelven irregulares recargue la bater a por 24 horas Nota Si la compuerta de la bater a no est cerrada adecuadamente puede entrar agua en el compartimento de la bater a causando que la unidad no funcione correctamente
3. Esta b scula en particular re ne los requisitos a prueba de agua IP67 para que la unidad entera se pueda lavar con agua o hasta en una lavadora de platos Esto permite una f cil limpieza y condiciones sanitarias superiores para servicio de comida y uso de venta al por menor Para Dejar Lista la B scula 1 Quite la b scula de la caja junto con la cubierta de la plataforma de acero inoxidable 2 Coloque la b scula sobre una superficie plana y dura Las superficies desparejos pueden afectar la precisi n Si se usa el adaptador de corriente alterna aseg rese de que la b scula no est puesta sobre el cable de lo contrario puede estar inestable 3 Coloque la cubierta de la plataforma sobre la base de la plataforma en la parte superior de la b scula Quite la pel cula protectora de la plataforma Medici n de peso general 1 Coloque la b scula sobre una superficie plana y dura 2 Presione el bot n ON OFF encendido apagado para se encender la b scula El visualizador primero muestra 18 888 y a continuaci n cero Si la pantalla no muestra cero presione el bot n TARE MODE tara modo para reiniciar tarar la b scula a cero 3 La b scula ha sido ajustada en f brica para mostrar el peso en libras Mientras la b scula est encendida presione el bot n UNIT LIGHT unidad luz para cambiar a kilogramos grammes unidades de medida Nota La b scula retenar la ltima unidad utilizada cuando s
4. 2000 grammes para calibrar adecuadamente la b scula 1 Quite cualquier peso de la plataforma de la b scula 2 Encienda la b scula Seleccione la unidad de peso que se va a calibrar libras o gramos 3 Apaga la b scula La unidad de peso seleccionada se almacenar en la memoria 4 Presione sin soltar el bot n TARE MODE tarar modo Mientras mantiene presionado TARE MODE tambi n presione el bot n ON OFF encendido apagado La pantalla muestre CAL luego cero Suelte ambos botones 5 Presione el bot n TARE MODE La pantalla muestre 5 Ib o 2000g Ponga el peso calibrado de 5lbs 2000g en la plataforma dependiendo de qu unidad de peso se seleccion en el Paso 2 7 Presione el bot n TARE MODE La pantalla muestra CAL F si la recalibraci n fue exitosa La b scula vuelve al modo de peso Nota Si la pantalla muestra CAL E la recalibraci n fall Repita los pasos anteriores o Diagn stico y resoluci n de Problemas e Sino hay art culos en la plataforma pero la pantalla LCD no muestra cero presione el bot n TARE MODE tarar modo para restablecer la b scula a cero e Advertencia de Sobrecarga Si la pantalla presenta Err durante una medida esto indica se ha excedido la capacidad de peso m xima de la b scula Retire el peso de inmediato de lo contrario se ocasionar un da o permanente a la b scula e Advertencia de bater a b
5. la pile rechargeable dans le compartiment 4 Replacez bien le couvercle du compartiment de pile 5 Pour charger la pile ins rez la fiche du connecteur de l adaptateur dans le jack l arri re de la balance Bouchez l autre extr mit de l adaptateur dans la bonne sortie lectrique Une ic ne de pile clignotera sur le relev de l ACL indiquant que la pile se charge Lorsque l ic ne de pile cesse de clignoter la pile est enti rement charge 6 Pr voyez 24 heures pour la charge compl te de la balance La balance fonctionnera continuellement pendant environ 14 heures 7 Le cycle de vie de la pile est d environ 500 recharges Si la balance ne fonctionne pas correctement apr s 24 heures de charge la pile devra peut tre tre remplac e La balance fonctionnera encore avec l adaptateur si la pile n est pas charg e 8 L appareil est maintenant pr t utiliser 9 Si Lo appara t l cran ACL ou si les relev s sont plus faibles ou irr guliers rechargez la pile pendant 24 heures Remarque Si la porte de pile n est pas ferm e correctement l eau pourrait entrer dans le compartiment de pile et mener un mauvais fonctionnement Gracias por comprar una b scula electr nica Taylor Su b scula Taylor es un ejemplo de dise o y mano de obra superiores Antes de usarla s rvase leer con atenci n este manual de instrucciones Guarde estas instrucciones en un lugar de f cil acceso para referencia futura
6. n HOLD mantener la pantalla LCD continuar indicando el peso de que el art culo es quitado de la plataforma Para activar la funci n Hold 1 2 Mientas la b scula est encendida coloque el art culo que desea pesar sobre la plataforma Presione los botones ZERO SET cero configurar y UNIT LIGHT unidad luz al mismo tiempo Cuando el peso quede fijo parpadear el icono O indicando que el peso sera mantenido en la pantalla LED cuando se retire el art culo Para quitar la funci n de mantener antes de que la b scula se apague presione el bot n ZERO SET La pantalla vuelve a cero La b scula puede ser apagada manualmente presionando el bot n ON OFF encendido apagado La funci n de mantener se desactiva autom ticamente cuando se apaga la b scula Nota La funci n HOLD mantener solo puede funcionar si el art culo pesado est estable en la plataforma Si el art culo no est estable verifique que la plataforma de la b scula est apoyada correctamente sobre la b scula Si fuera necesario mueva el art culo levemente en la plataforma hasta que el peso queda fijo Operaci n de l mite de peso Alto Bajo Si lo desea puede establecer un rango l mite en el peso La b scula le alertar cuando un objeto que se est pesando est por debajo o por encima del l mite establecido 1 a Nota La funci n de l mite alto bajo no operar si la
7. not closed properly water can get into the battery compartment causing the unit to malfunction gt Merci de votre achat d une balance num rique Taylor Votre balance Taylor est un exemple de design et de travail sup rieurs Afin d en soutirer le maximum veuillez lire attentivement votre manuel d instructions avant d utiliser l appareil Conservez ces instructions port e de la main titre de r f rence Cette balance r pond aux exigences d tanch it IP67 alors toute l unit peut se laver avec de l eau ou m me nettoy e au lave vaisselle Ceci permet de nettoyer facilement et d atteindre des conditions hygi niques pour le service alimentaire et l utilisation au d tail Pr paration de la balance 1 Retirez la balance ainsi que l enveloppe de la plate forme en acier inoxydable de la bo te 2 Placez la balance sur une surface rigide et horizontale L utilisation de la balance sur une surface in gale affectera la pr cision de l appareil Si vous utilisez l adaptateur de c a assurez vous que la balance ne repose pas sur le cordon car elle sera instable 3 Placez le couvercle de plate forme sur la base de plate forme sur le dessus de la balance Enlevez toute pellicule protectrice de plate forme Fonctionnement G n ral de Pes e 1 Placez la balance sur une surface rigide et horizontale 2 Appuyez sur la touche ON OFF marche arr t pour mettre la balance sous tension L affichage indiqu
8. ou 20009 6 Placez soit le poids calibr de 5 lb ou 2 000 g sur la plate forme selon l unit de poids choisie l tape 2 7 Appuyez la touche TARE MODE L affichage montre CAL F si le recalibrage r ussit La balance revient au mode de pes e Remarque Si l affichage montre CAL E si le recalibrage n a pas r ussi R p tez les tapes precedents D pannage e S il n y a pas d items sur le plate forme mais que l afficheur ACL n indique pas z ro appuyez sur la touche TARE MODE tarage mode pour remettre la balance z ro e Avertisseur de surcharge Si Er appara t sur l afficheur ACL durant une op ration de pesage ceci signifie que la capacit maximale de la balance a t d pass e Enlevez imm diatement l item se trouvant alors sur le plate forme de la balance d faut de quoi des dommages permanents la balance pourraient s ensuivre e Avertissement de pile faible Si Lo appara t sur l afficheur ACL o les relev s seront plus faibles ou irr guliers rechargez la pile pendant 24 heures Funci n de Calibraci n Debe verificar ocasionalmente la precisi n de la b scula midiendo un peso conocido de la capacidad aproximada de la b scula Tare la b scula presionando ZERO SET cero configurar coloque el peso en la plataforma y tome nota de la lectura Calibre la b scula si fuera necesario Procedimiento de Calibraci n Debe usar SOLAMENTE un peso calibrado de 5 libras ou
9. will automatically turn off after approximately 4 minutes of nonuse Press the ON OFF button to turn the scale off manually If the scale is operating on adapter power it will remain on until the ON OFF button is manually pressed Tare Operation You may wish to weigh ingredients in a bowl or other container not included In this case you will need to tare or offset the weight of the bowl so that only the weight of the ingredients is displayed 1 Choose a container that will safely balance on the platform without tipping or falling Do not use a heavy container as this might reduce the maximum capacity of the scale 2 While the scale is off place the empty container on the scale platform Turn the scale on The display will show 18 888 then 0 0 The weight of the container has been zeroed out 3 Add the ingredient to be weighed The weight of the ingredient alone will display 4 The weight of additional ingredients may be tared out as well For example to measure e lb rice and lb beans together place the rice into the bowl Once the correct amount of rice is weighed press the TARE MODE button until the display resets to zero Add 2 Ib of beans Both ingredients have been accurately weighed in the same bowl 5 Press ZERO SET and TARE MODE at the same time to view the total weight of all ingredients 6 When weights have been tared out the display will show a negative numbe
10. Precision Products and its affiliated companies all rights reserved Taylor and Leading the Way in Accuracy60 are registered trademarks of Taylor Precision Products and its affiliated companies All rights reserved Made to our exact specifications in China NOT LEGAL FOR TRADE TEJOSSW 10 09 TE10SSW TAYLOR Waterproof Digital Scale Leading the Way in Accuracy e Instruction Manual Fonction d talonnage On devrait l occasion v rifier la pr cision de la balance en pesant un objet don t le poids connu se rapproche de la capacit maximale de la balance Appuyez sur la touche ZERO SET z ro r gler pour r initialiser tarage la balance placez le poids sur le plate forme et effectuez une lecture Si n cessaire proc der l talonnage de la balance Proc dure de recalibrage Vous devez utiliser UNIQUEMENT un poids talonn de 5 Ib ou 2000g afin de proc der au recalibrage de la balance 1 Retirez tout poids de la plate forme de la balance 2 Allumez la balance Choisissez l unit de poids calibrer lb ou g 3 teindre la balance L unit de poids choisie sera stock e en m moire 4 Appuyez et maintenez enfonc e la touche TARE MODE tarage mode Tout en maintenant enfonc e la touche TARE MODE appuyez la touche ON OFF marche arr t L affichage pr sente CAL puis z ro Rel chez les deux touches 5 Appuyez la touche TARE MODE L affichage pr sente 5 lb
11. aja Si la pantalla presenta Lo o las lecturas se volver n borrosas o irregulares recargue la bater a por 24 horas Pr cautions 1 Toujours lire le guide d utilisation afin de permettre de soutirer le maximum des possibilit s de l appareil 2 PR CAUTIONS DE LAVAGE Avant de laver la balance retirez toujours l adaptateur Assurez vous que le bouchon de caoutchouc couvrant le jack de l adaptateur est bien pouss dans le jack Assurez vous que le couvercle du compartiment de pile est bien install Si vous ne le faites pas vous pourriez avoir de l eau qui entre dans la balance menant des dommages permanents qui annuleront votre garantie 3 NE PAS nettoyer l appareil avec des mat riaux abrasifs ou corrosifs Ceci peut rayer les composantes en plastique de l apporeil et corroder les circuits lectroniques 4 NE PAS soumettre l appareil une force abusive des chocs la poussi re et des extr mes de temp rature et d humidit Ceci pourrait causer un mauvais fonctionnement de l appareil une d formation des pi ces une diminution de la dur e de vie des composantes lectroniques ou des dommages la pile 5 NE PAS utiliser ou entreposer l appareil dans des conditions de temp rature ou d humidit lev es La chaleur et l humidit peuvent affecter les composantes internes de la balance 6 NE PAS tenter de modifier ou r parer vous m mes les composantes internes de l appareil Ceci annulera la ga
12. appuyez sur la touche ZERO SET L afficheur ACL sera remis z ro On peut mettre la balance hors tension manuellement en appuyant sur la touche ON OFF marche arr t La fonction de garde est automatiquement d sactiv e lors de la mise hors tension de la balance Remarque La fonction de garde Hold peut tre utilis e seulement si le poids sur le plate forme est stable Si l item n est pas stable v rifiez d abord que le plate forme repose correctement sur la balance Si n cessaire d placez l item l g rement sur le plate forme jusqu le poids est verrouill Fonctionnement de limite de poids haute basse Vous pouvez choisir de r gler une limite de plage de poids La balance vous avisera lorsqu un article pes est inf rieur ou sup rieur la limite r gl e 1 Alors que la balance est sous tension enfoncez et gardez la touche TARE MODE tarage mode enfonc e pendant 3 secondes La balance fasse entendre un bip et l affichage montrera Lo puis z ro Placez la charge limite INF RIEURE sur la plate forme Appuyez sur la touche ZERO SET z ro r gler jusqu ce que la balance fasse entendre un bip La imite INF RIEURE est r gl e Placez la charge limite SUP RIEUR sur la plate forme Appuyez sur la touche ZERO SET jusqu ce que la balance fasse entendre un bip La limite SUPERIEUR est r gl e Placer l item peser sur le plate forme La balance fera entendre un bip si art
13. b scula est en modo HOLD Mientas la b scula est encendida presione sin soltar el bot n TARE MODE tarar modo durante 3 segundos La b scula sonar y la pantalla parpadear Lo y luego cero Ponga la carga de l mite BAJO en la plataforma Presione el bot n ZERO SET cero configurar hasta que la b scula pite El l mite BAJO est establecido Ponga la carga de l mite ALTO en la plataforma Presione el bot n ZERO SET hasta que la b scula pite El l mite ALTO est establecido Coloque el art culo que desea pesar sobre la plataforma La b scula pitar si el art culo est por encima o por debajo del l mite Bajo Alto establecido Para borrar el l mite Bajo Alto presione sin soltar los botones TARE MODE y ZERO SET al mismo tiempo La b scula pitar y mostrar ceros cuando el l mite est borrado De lo contrario los l mites se borrar n cuando la b scula se apague Fuentes de Energ a Esta b scula funciona con un adaptador de CA incluido o una bater a recargable incluida Energ a el ctrico Para encender la b scula usando el adaptador de CA jale suavemente el tap n de hule del tomacorriente del lado izquierdo de la b scula Inserte el enchufe en el tomacorriente despu s conecte el otro extremo en el tomacorriente el ctrico adecuado Nota importante antes de lavar la b scula siempre quite el enchufe y coloque adecuadamente el tap n de hule
14. contains no user serviceable parts 7 This scale is an extremely sensitive weighing device To avoid damage to the unit or the battery do not store anything on the scale 8 This scale operates on an AC adapter included or a rechargeable battery included Do not dispose of this scale or batteries in fire as the batteries may explode or leak Remove the battery if the scale will not be used for a long period of time One Year Limited Warranty This product is warranted against defects in materials or workmanship for one 1 year for the original purchaser from date of original purchase It does not cover damages or wear resulting from accident misuse abuse or unauthorized adjustment and or repair Should this product require service or replacement at our option while under warranty please pack the item carefully and return it prepaid along with receipt showing date of purchase and a note explaining reason for return to Taylor Precision Products 2220 Entrada Del Sol Suite A Las Cruces New Mexico 88001 USA Customer Service Phone 1 800 225 4834 Customer Service Fax 1 575 526 4347 www taylorusa com There are no expressed warranties except as listed above This warranty gives you specific legal rights and you may also have other rights which vary from state to state For additional product information or warranty information in Canada or elsewhere outside the USA please contact us through www taylorusa com 2009 Taylor
15. e apaga y enciende de nuevo 4 Coloque el art culo que desea pesar sobre la plataforma La pantalla contar y luego mostrar el peso del art culo A medida que agrega peso el peso que se indica aumenta El peso queda fijo cuando aparece un cono O estable Cuando se retira todo el peso el visualizador vuelve a cero 5 Sila b scula est funcionando con bater a se apagar autom ticamente despu s de aproximadamente 4 minutos de no usarse Presione el bot n ON OFF para apagar la b scula en forma manual Si la b scula est funcionando con adaptador de corriente seguir encendida hasta que el bot n de ON OFF se presione manualmente Operaci n de Tara Puede pesar ingredientes en un recipiente no incluido En este caso necesitar tarar o compensar el peso del recipiente para que se muestre solamente el peso de los ingredientes 1 Elija un recipiente que quede equilibrado sobre la plataforma en forma segura sin tambalearse ni caerse No utilice un recipiente pesado ya que esto puede reducir la capacidad m xima de la b scula 2 Mientras la b scula est apagada coloque el recipiente vac o en la plataforma de la b scula Encienda la b scula La pantalla mostrar 18 888 y luego cero El peso del recipiente se puso en cero 3 Agregue el ingrediente que desea pesar Se mostrar el peso del ingrediente solo 4 El peso de los ingredientes adicionales tambi n se tarar Por ejemplo s
16. ee that the scale platform rests properly on the scale If necessary move the item slightly on the platform until the weight locks in High Low Limit Weighing Operation You may wish to set a weight range limit The scale will alert you when an item weighed is under or over the set limit 1 2 While the scale is on press and hold the TARE MODE button for 3 seconds The scale will beep and the display will show Lo then zero Place the LOW limit load on the platform Press the ZERO SET button until the scale beeps The LOW limit is set Place the HIGH limit load on the platform Press the ZERO SET button until the scale beeps The High limit is set Place the item to be weighed on the platform The scale will beep if the item is over or under the set Low High limit To clear the Low High limit press the TARE MODE and ZERO SET buttons at the same time The scale will beep and show zeros when the limit is cleared Otherwise the limits will clear when the scale is turned off Note The high low limit function will not operate if the scale is in the HOLD mode Power Sources This scale operates on an AC adapter included or one rechargeable battery included Electrical Power To power the scale using the AC adapter gently pull back the rubber stopper from the jack on the left side of the scale Insert the connector plug into the jack then plug the other end into the pr
17. eighing capacity of the scale has been exceeded Remove the weight immediately otherwise permanent damage could occur e Low Battery Warning Should Lo appear on the LCD or readings grow dim or irregular recharge the battery for 24 hours Precautions This scale is engineered to give you years of satisfactory service if you handle it carefully Here are a few precautions 1 Always read instructions thoroughly to ensure that you have the full benefit of all the unit s features 2 WASHING PRECAUTIONS Before washing the scale always remove the adapter Be certain the rubber plug covering the adapter jack is securely pushed into the jack Be certain the battery compartment cover is securely attached Failure to do either may result in water entering the scale and causing permanent damage which will void your warranty 3 DO NOT clean the unit with an abrasive or corrosive material This may scratch the plastic parts and corrode the electronic circuits 4 DO NOT subject the units to excessive force shock dust temperature or humidity This may result in malfunction shorter electronic life span damaged battery and distorted parts 5 DO NOT operate or store the scale in high temperature or humidity conditions The heat or moisture may interfere with the scale s internal components 6 DO NOT tamper with the unit s internal components Doing so will invalidate the warranty on the units and may cause damage The unit
18. en el tomacorriente Si no hace esto puede ocasionar que entre agua en la b scula y que cause da o permanente Energ a de la bater a Para encender la b scula usando una bater a recargable incluida 1 2 A Quite la tapa del compartimento de la bater a que se encuentra en la parte de abajo de la b scula Conecte el conector macho de la bater a recargable en el conector hembra que est localizado en el compartimento de la bater a Coloque la bater a recargable en el compartimiento de la bater a Vuelva a colocar la tapa del compartimiento de la bater a Para cargar la bater a inserte el enchufe conector del adaptador en el tomacorriente de la parte trasera de la b scula Conecte el otro extremo del adaptador en el tomacorriente el ctrico adecuado Un cono de una bater a va a parpadear en la pantalla LCD indicando que la bater a se est cargando Cuando el cono de la bater a deje de parpadear la bater a est cargada por completo D 24 horas para que la b scula se cargue completamente La b scula trabajar continuamente por 14 horas aproximadamente El ciclo de vida de la bater a es de aproximadamente 500 recargas Si la b scula no funciona adecuadamente despu s de 24 horas de carga puede ser que la bater a tenga que reemplazarse La b scula seguir trabajando con el adaptador de corriente si la bater a no est cargada Su b scula est ahora lista para usar Si
19. era d abord 18 888 suivi de z ro Si l affichage n indique pas z ro appuyer nouveau sur la touche TARE MODE tarage mode pour r initialiser tarage la balance z ro 3 La balance est r gl e en usine indiquer les poids en livres Pour modifier l affichage au lb 0z oz ou grammes appuyez sur la touche UNIT LIGHT unit clairage lorsque la balance est sous tension Remarque La balance conservera la derni re unit utilis e en l teignant et la rallumant 4 Placer l item peser sur le plate forme Les chiffres de l afficheur ACL changeront jusqu ce que l affichage indique le poids de l item Que vous ajouterez des items sur le plate forme le poids indiqu augmentera Le poids est verrouill lorsque l ic ne O droite appara t Lorsque tous les items auront t enlev s de le plate forme l affichage indiquera nouveau z ro 5 Si la balance fonctionne pile elle s teindra automatiquement apr s environ 4 minutes de non utilisation Appuyez sur la touche ON OFF pour mettre la balance hors tension manuellement Si la balance fonctionne avec le courant de l adaptateur elle restera en marche jusqu ce que la touche ON OFF soit enfonc manuellement Op ration de Tarage Vous pouvez vouloir peser des ingr dients dans un bol ou un autre contenant non inclus Dans ce cas vous devez d duire le poids du bol ou du contenant de sorte que seul le poids des ingr dients sera affich le
20. f requirements so the entire unit can be washed down with water or even cleaned in a dishwasher This allows for easy cleaning and high sanitary conditions for food service and retail use To Ready Scale for Use 1 Remove the scale from its box along with its stainless steel platform cover 2 Place the scale on a hara flat surface Uneven surfaces will affect accuracy If using the AC adapter make sure the scale is not resting on the cord otherwise it may be unstable 3 Place the platform cover over the platform base on top of the scale unit Remove any protective film from the platform General Weighing Operation 1 Place the scale on a hard level surface 2 Press the ON OFF button to turn the scale on The display first shows 18 888 followed by zero If the display does not show zero press the TARE MODE button to reset tare the scale to zero 3 The scale is set at the factory to weigh in pounds While the scale is on press the UNIT LIGHT button to switch to lb 0z oz or gram units of measurement Note The scale will retain the last unit used when it is turned off and on again 4 Place the item to be weighed onto the platform The display will count up to the weight of the item As you add weight the weight displayed increases When all the weight is removed the display will return to zero The weight is locked in when the O icon appears 5 If the scale is operating on battery power it
21. i una receta requiere lb de arroz y e lb de frijoles coloque el arroz en el recipiente Una vez que se haya pesado la cantidad correcta de arroz presione el bot n TARE MODE tarar modo hasta que la pantalla vuelva a cero Agregue la Y lb de frijoles Ambos ingredientes se han pesado en forma precisa en el mismo recipiente 5 Presione ZERO SET cero configurar y TARE MODE tarar modo al mismo tiempo para ver el peso total de todos los ingredientes 6 Cuando los pesos se hayan tarado la pantalla mostrar un n mero negativo cuando los art culos se retiren de la b scula Para reiniciar la b scula a cero para una nueva medici n presione el bot n TARE MODE hasta que la pantalla se reinicie a cero Caracter stica de iluminaci n posterior Su b scula Taylor est equipada con un caracter stica de iluminaci n posterior para facilitar la visualizaci n Presione sin soltar el bot n UNIT LIGHT unidad luz durante 3 segundos para activar el iluminaci n posterior Presione sin soltar el bot n UNIT LIGHT durante tres segundos otra vez para desactivar la iluminaci n trasera Funci n de Apagado Autom tico La b scula se apagar autom ticamente luego de 4 minutos sin uso para la conservaci n de la bater a Tenga en cuenta que la funci n de apagado autom tico no puede desactivarse en esta balanza en particular Funci n Hold mantener Cuando est encendida la funci
22. icle est au dessus ou au dessous de la limite r gl e Basse Haute Pour effacer la limite basse haute enfoncez TARE MODE et ZERO SET et en m me temps La balance fera entendre un bip et montrera des z ros lorsque la imite est effac e Sinon les limites s effaceront lorsque la balance est teinte Remarque La fonction limite haute basse ne fonctionnera pas si la balance est en mode HOLD MAINTIEN Sources d alimentation lectrique Cette balance fonctionne lorsque branch e une prise de courant r guli re l aide d un adaptateur courant alternatif ou CA inclus ou l aide d une pile rechargeable incluse Alimentation par branchement une prise de courant To power the scale using the AC adapter gently pull back the rubber stopper from the jack on the left side of the scale Insert the connector plug into the jack then plug the other end into the proper electrical outlet Important note before washing the scale always remove the plug and securely replace the rubber stopper into the jack Failure to do so may result in water entering the scale and causing permanent damage Le courant de pile Pour utiliser votre balance en utilisant une pile rechargeable comme source d alimentation pile incluse 1 Retirez le couvercle du compartiment de pile au bas de la balance 2 Bouchez le collecteur m le de la pile rechargeable sur le connecteur femelle qui se trouve dans le compartiment de pile 3 Placez
23. ndedor minorista S rvase empacar el art culo cuidadosamente y env elo con el franqueo pagado junto con el recibo de la tienda en el que aparezca la fecha de compra y una nota explicando el motivo de la devoluci n Taylor Precision Products 2220 Entrada Del Sol Suite A Las Cruces New Mexico 88001 USA Tel fono del Servicio al cliente 1 800 225 4834 Fax del Servicio al cliente 1 575 526 4347 www taylorusa com No existen garant as expresas excepto las enunciadas anteriormente Esta garant a le otorga derechos legales espec ficos y es posible que usted tenga otros derechos que var en de un estado a otro Para obtener informaci n adicional sobre el producto o informaci n de la garant a en Canad o en otro sitio fuera de los EE UU s rvase contactarnos a trav s de www taylorusa com Fabricado en China seg n nuestras especificaciones exactas No es legal para uso comercial TE10SSW TAYLOR Balance num rique tanche Leading the Way in Accuracy e Manuel d instructions TE10SSW TAYLOR B scula digital a prueba de agua Leading the Way in Accuracy e Manual de instrucciones Thank you for purchasing a Taylor Digital Scale Your scale is an example of superior design and craftsmanship In order to optimize ts function be sure the read this instruction manual carefully before use Keep these instructions handy for future reference This particular scale meets IP67 Waterproo
24. oper electrical outlet Important note before washing the scale always remove the plug and securely replace the rubber stopper into the jack Failure to do so may result in water entering the scale and causing permanent damage Battery Power To power the scale with a rechargeable battery includea Remove battery compartment cover on the bottom of the scale 2 Plug the male connector of the rechargeable battery onto the female connector which is located in the battery compartment 3 Place the rechargeable battery into the battery compartment Replace the battery compartment cover 5 To charge the battery insert the connector plug of the adaptor into the jack at the back of the scale Plug the other end of the adaptor into the proper electrical outlet A battery icon will flash on the LCD readout indicating the battery is charging When the battery icon stops flashing the battery is completely charged 6 Allow 24 hours for the scale to charge completely The scale will then operate continuously for approximately 14 hours 7 The battery life cycle is approximately 500 recharges If the scale does not function properly after 24 hours of charging the battery may need to be replaced The scale will still operate on adaptor power if the battery is not charged 8 Your scale is now ready for use 9 If Lo appears on the LCD or readings grow dim or irregular recharge the battery for 24 hours Note If the battery door is
25. out abus utilisation commerciale ou r glage interdit et ou r paration interdite Si ce produit doit tre r par ou remplacement notre discr tion ne le retournez pas au d taillant Veuillez l emballer avec soin et le retourner frais pr pay s avec la facture du magasin indiquant la date d achat et une note expliquant la raison du retour l adresse suivante Taylor Precision Products 2220 Entrada Del Sol Suite A Las Cruces New Mexico 88001 USA T l phone de Service la client le 1 800 225 4834 Fax de Service la client le 1 575 526 4347 www taylorusa com Il n y a aucune garantie expresse sauf celle indiqu e pr c demment Cette garantie vous donne des droits pr cis mais vous pouvez aussi avoir d autres droits qui varient d une juridiction l autre Pour de l information suppl mentaire sur le produit ou sur la garantie au Canada ou ailleurs l ext rieur des E U veuillez nous contacter par www taylorusa com Fabriqu en Chine selon nos sp cifications exactes Non l gal pour le commerce Garant a limitada por un a o Taylor garantiza este producto contra defectos en los materiales y en la mano de obra durante 1 un a o a partir de la fecha de compra original No cubre da os ni desgastes que sean consecuencia de accidentes uso inadecuado abuso uso comercial ni ajustes y o reparaciones no autorizadas Si este producto requiere mantenimiento o cambio a nuestro entender no la devuelva al ve
26. r when the items are removed from the scale To reset the scale back to zero for a new measurement simply press the TARE MODE button again The scale will reset to zero Backlight Feature Your Taylor scale is equipped with a backlight feature for easy viewing Press and hold the UNIT LIGHT button for 3 seconds to activate the backlight Press and hold for 3 seconds again to deactivate the backlight Auto Shut off Feature The scale will automatically shut off after 4 minutes of nonuse to conserve the battery Please note the auto off function cannot be disabled on this particular scale Hold Function When the HOLD function is turned on the LCD screen will continue to display the weight after the item is removed from the platform To turn on the Hold function 1 2 While the scale is on place the item to be weighed on the platform Press ZERO SET and UNIT LIGHT at the same time When the weight is locked in an O icon flashes indicating the weight will be held on the LCD when the item is removed To release the hold function before the scale shuts off press the ZERO SET button The LCD will return to zero The scale may be turned off manually by pressing the ON OFF button The Hold function is automatically disabled when the scale turns off Note The HOLD function can only operate if the weight is stable on the platform If the weight is unstable check to s
27. rantie et pourrait causer des dommages Cet appareil ne contient aucune pi ce pouvant tre r par e par l utilisateur 7 Cette balance un appareil de mesure d une tr s grande sensibilit Afin d viter tout dommage l appareil ou la pile ne rien entreposer sur le plate forme de la balance 8 Cette balance fonctionne lorsque branch e une prise de courant r guli re l aide d un adaptateur courant alternatif ou CA inclus ou l aide d une pile rechargeable incluse Ne pas jeter cet appareil ou les piles au feu puisque les piles peuvent exploser ou engendrer des fuites de produits corrosifs Enlever la pile si l appareil n est pas utilis durant une p riode de temps prolong e Precauciones Esta b scula est dise ada para proporcionarle a os de servicio satisfactorio si la maneja con cuidado A continuaci n le presentamos algunas precauciones 1 Lea siempre las instrucciones por completo para asegurarse de disfrutar del beneficio completo de todas las funciones de esta unidad 2 PRECAUCIONES DE LAVADO Antes de lavar la b scula siempre quite el adaptador Aseg rese de que el tap n de hule que tapa el tomacorriente del adaptador est firmemente colocado en el tomacorriente Aseg rese de que el compartimento de la bater a est firmemente sujetado Si no hace ninguna de las dos cosas puede que entre agua en la b scula y que cause da o permanente lo cual invalidar la garant a 3 NO limpie la
28. terme fran ais pour ce type d op ration est tarage 1 Choisissez un contenant dont la forme et la grandeur lui permettent d tre en quilibre stable sur le plate forme de la balance N utilisez pas un contenant trop lourd qui r duirait la capacit maximum de la balance 2 Alors que la balance est hors tension placez le contenant vide sur le plate forme de la balance Mettre la balance sous tension L affichage indiquera 18 888 et ensuite z ro Cette op ration permet la balance d annulen le poids du contenant Ajoutez les ingr dients peser Seul le poids des ingr dients sera affich Le tarage peut galement tre utilis pour mesurer le poids d ingr dients additionnels Par exemple supposons que vous vouliez peser ensemble lb de riz et Y Ib de f ves Placez d abord le riz dans le contenant Lorsque la quantit correcte de riz a t atteinte appuyez sur la touche TARE MODE tarage mode jusqu ce que l affichage indique z ro Ajoutez 2 lb de f ves Les deux ingr dients auront alors t pr cis ment pes s dans le m me contenant Enfoncez ZERO SET z ro r gler et TARE MODE tarage mode en m me temps pour afficher le poids total de tous les ingr dients Lorsque les poids sont tar s l affichage montrera un chiffre n gatif lorsque les articles sont retir s de la balance Pour r initialiser la balance pour une nouvelle s rie de mesures simplement appuyez nouvea
29. u sur la touche TARE MODE La balance sera ainsi remise z ro a o a o Fonction de r tro clairage Votre balance Taylor est dot e d une fonction de r tro clairage pour faciliter l affichage Appuyez et gardez enfonc la touche UNIT LIGHT unit clairage pendant 3 secondes pour activer le fonction de r tro clairage Appuyez et gardez enfonc la touche UNIT LIGHT enfonc pendant 3 secondes nouveau pour d sactiver le r tro clairage Fonction de mise hors tension automatique Afin d conomiser la pile la balance se mettra automatiquement hors tension apr s 4 minutes si elle n est pas utilis e Veuillez noter que la fonction d arr t automatique ne peut pas tre d sactiv e sur ce type de balance Fonction de garde Hold Maintien Lorsque la fonction de garde Hold est activ e l afficheur ACL continuera d afficher le poids apr s que les ingr dients auront t enlev s de plate forme Pour activer cette fonction 1 Alors que la balance est sous tension placez le contenant vide sur le plate 2 forme de la balance Appuyez simultan ment les touches ZERO SET z ro r gler et UNIT LIGHT unit clairage Lorsque la mesure du poids est compl t e l ic ne O clignote indiquant ainsi que le poids sera gard sur l afficheur ACL lorsque l item sera enlev du plate forme Pour d sactiver la fonction de garde avant la mise hors tension de la balance
30. unidad con materiales abrasivos ni corrosivos Esto puede rayar las piezas pl sticas y corroer los circuitos electr nicos 4 NO exponga la unidad a fuerza choques polvo temperatura ni humedad en exceso Esto puede hacerla funcionar mal acortar la vida til electr nica da ar las bater as o deformer las piezas 5 NO haga funcionar ni guarde esta b scula en condiciones de alta temperatura o humedad El calor y la humedad pueden interferir con los componentes internos de la b scula 6 NO manipule los componentes internos de la unidad Hacerlo invalidar la garant a de este producto y puede causar da os Aparte del cambio las bater as esta unidad no contiene piezas que necesiten servicio por parte del usuario 7 Esta b scula es un dispositivo de pesaje extremadamente sensible Para evitar da o a la unidad o la bater a no almacene nada sobre la b scula 8 Esta b scula funciona con un adaptador AC incluido o con una bater as recargable incluida No tire esta b scula o las bater as al fuego Las bater as pueden explotar o tener p rdidas Retire la bater a si la b scula no se utilizar por un largo tiempo Garantie limit e d un an Taylor garantit que ce produit est libre de tout d faut de mat riaux ou de main d oeuvre pour une p riode d un 1 an pour l acheteur original partir de la date d achat original Elle ne couvre pas les dommages ou l usure suite un accident une mauvaise utilisation t