Home

Summer Infant 3170 User's Manual

image

Contents

1. sign 89 is displayed You can repeat the process again from step 3 onwards 4 Power off e Power will be automatically turned if the thermometer is left Unattended for 1 minute TROUBLESHOOTING If you encounter problems with the operation of your Ear Thermometer please check the following points to see if they can be rectified If the problem still persists please contact the service center for servicing Do not disassemble or attempt to repair the thermometer yourself e Nothing is displayed after O I Battery may be worn out button pressed Replace with new battery Battery may not be placed in the correct polarities Place batteries according to the polarities indicated TROUBLESHOOTING continued sign is displayed 10 Measurement cannot be made or abnormal value is displayed is displayed Measurement will not start after pressing the button Measured result is Hi or Lo Possible cause and solution Low battery signal Replace with new battery Tip of probe may be dirty or damaged Clean the probe Excessive earwax in the ear canal Clean the ear canals with a cotton swab Probe may be insterted incorrectly Insert the probe correctly Follow inserting the probe into the ear canal under use of your product page 8 If the problem still persists send to service center for repair There may be a short circuit Please contact service center The ambient temp
2. 03170 Sse Please read the following instructions Summer and warnings carefully Keep this instruction manual for future reference Requires 2 AAA batteries included For Technical Support Call 1 800 268 6237 or E Mail at bo customerservice summerinfant com For use with children from birth and up INSTRUCTION MANUAL ONE SECOND EAR THERMOMETER Thank you for purchasing the One Second Ear Thermometer Before you start using your new Ear Thermometer please read this operation manual thoroughly for the correct methods of usage especially section on Safety This manual should be kept on hand for easy future reference A WARNING e Use of this thermometer is not intended as a substitute for consultation with your physician e The thermometer is not waterproof NEVER immerse into liquids A CAUTION THIS PRODUCT IS NOT A TOY ADULT SUPERVISION IS REQUIRED STORE AWAY FROM CHILD S REACH CONTENTS Safety Page 2 Notes on Temperature Page 3 Parts and Accessories Index Page 4 Features and Effectiveness Page 4 Preparation Before Use Page 5 Use of Your Product Page 7 Troubleshooting Page 8 Product Care and Storage Page 9 Specifications Page 10 SAFETY Safety Precautions During Use Do not drop step on or subject the ear thermometer to any shock or vibration Do not submerge this product in water or any other liquid Do not use excessive force to insert the probe into the ear Use of excessive force ma
3. e measuring position is different The following drawing is taken from ASTM E1965 for your reference Fig 1 PARTS AND ACCESORIES INDEX a 2 Main Body 1 Probe 2 Start Button 3 LCD 4 O I Button 5 Battery Cover 5 FEATURES AND EFFECTIVENESS Features The ear thermometer is simple and convenient to use with one button operation Loading of a probe cover is not required before taking a measurement making the thermometer more user friendly and more cost effective Measures temperature in one second Unique and slim design following the contour of human s palm for easy handling Comes with a large LCD for easy reading Operated by two AAA batteries for easy replacement Auto off function helps you to save energy in the batteries The ear thermometer is light and compact allowing you to take it everywhere Effectiveness Compared to traditional thermometers which require several minutes to take the temperature the ear thermometer takes only one second to display the measurement It is safer to take the temperature in the ear as there is no risk of infection caused by contact with mucous membrane in the oral cavity or the rectum as in conventional measurement Operating environment from 41 F 104 F 5 C 40 C makes it easy for you to take a measurement PREPARATION BEFORE USE 1 General Ensure that your ear is clean If your ear is clogged with excessive earwax measurement may be inaccura
4. ease contact our Customer Service Department at 1 800 268 6237 or e mail us at customerservice summerinfant com Summer Infant Inc Summer Infant Europe LTD 6 Blackstone Valley Place Suite 206 20 Sparrows Herne Lincoln RI 02865 USA 1 800 268 6237 Bushey Hertfordshire www summerinfant com WD23 1FX UK 44 0 20 8420 4429 2005 Summer Infant Inc Colors and styles may vary 12 MADE IN CHINA 7 05
5. erature has exceeded the specific range of 41 F 104 F 5 C 40 C Measurement is made when the lt a is not displayed Measure again after the sign is displayed Hi is displayed when the body temperature is more than 107 6 F 42 C Lo is displayed when the body temperature is less than 95 F 35 C PRODUCT CARE AND STORAGE WN General Clean off dirt in the main body with a clean soft and dry cloth Do not clean the main body with water nor a cleaner containing abrasive agents thinner or benzene Before and after each use clean the thermometer Batteries If the low battery indicator flashes during use replace with new batteries refer to page 5 under preparation before use point 2 on the procedure for replacement of new batteries Remove the batteries if you will not be the product for a long period of time Probe Clean the probes surface with a cotton swab slightly moistened with alcohol and immediately dry it with a clean cotton swab After cleaning allow at least 5 minutes to dry before using it again Do not clean the probe with a paper towel or paper as it contains glass fiber which may damage the lens at the tip of the probe After cleaning dry the probe thoroughly before store it To assure a high level of accuracy it is very important to keep the probe clean dry and unchanged Fingerprints earwax dust and other soiling compounds reduces the transparency of the w
6. indow and results in lower temperature reading Avoid touching the probe except when cleaning is required As the probe is the most sensitive and delicate part of the thermometer it is extremely important to ensure that a probe cover is always on the probe to protect it from dirt and damage 4 Storage Do not store the ear thermometer under direct sunlight or in places where temperature and humidity are very high or very low in dusty or wet places or where the product be affected by a vibrating shock BATTERY WARNING Keep battery out of child s reach Swallowing battery could be fatal Battery should not be charged or placed in extreme heat as it may rupture Used batteries should be disposed of properly 11 NOTES ON TEMPERATURE Product One Second Ear Thermometer Battery Type 2xAAA 1 5V Accuracy 36 F 0 2 C Measuring Range 89 6 F 109 22 F 32 C 42 9 C Display Resolution 0 1 Operating Ambient Temperature Range 41 F 104 F 5 C 40 C Relative Operating Humidity 15 to 95 RH Storage Environment 13 F 131 F 25 C to 55 C Relative Storage Humidity 30 to 95 RH The ear thermometer meets American Society for Testing and Materials accuracy standards ASTM with requirements specified in ASTM stands E 1965 98 as it pertains to infrared thermometers and when used under normal operating conditions We at Summer Infant stand behind all of our products If you are not completely satisfied or have any questions pl
7. is recommended that you take the temperature three times in the same ear If the temperature happens to differ use the highest reading Be aware that slight variations 36 F 54 F 0 2 0 3 C can occur if consecutive measurements are taken e Infants 3 months and below e Children under 3 years who have a condition such as a compromised immune system and for whom the presence or absence of fever is critical e When you are first learning to use the ear thermometer until you are comfortable with the technique and are obtaining consistent readings Caution For individuals who have hair in their ears please note that the measured temperature may be lower than the actual temperature USE OF YOUR PRODUCT 1 Power on e Press the O I button e The thermometer will show the following display UD 4r j e There will be a display for an automatic function test as indicated below e After the completion of the automatic function test a beep sound will indicate the thermometer is ready for measuring the temperature Caution If no further operation is activated the display goes off automatically 1 minute after activation or after measuring the temperature USE OF YOUR PRODUCT continued 2 Inserting the probe into the ear canal Gently Pull Outer Ear Straighten Ear Canal Less than 1 Year S 1 Year and older Fully Insert Thermometer Probe Gently into Ear For children aged 1 year or above and f
8. or adults e Pull the ear slightly backwards and insert the probe along the ear canal in a straight direction e Insert the probe until the body of the probe fully seals the ear canal and hold it there until measurement is completed For an infant less than 1 year old e Pull the ear diagonally behind to make the ear canal straight e Apply the tip of the probe straight against the ear canal Hold in this position until measurement is completed For measuring your own temperature e Hold the main body of the thermometer and insert the probe along your own ear canal Push the probe naturally against the ear canal and insert it further After confirming that the probe and the ear canal are in close contact start the measurement USE OF YOUR PRODUCT continued 3 Starting the measurement e Press and release the O I button e Ensure that the ready to measure sign 8l is displayed and a beep sound is heard before measurement If the START button is pressed before the sign is displayed the thermometer will not start the measurement e It will beep once and measurement will begin e After one second the ear thermometer will give out a beeping sound to signal completion of measurement Remove the ear thermometer from the ear canal and check the reading on the display panel e If you want to repeat the measurement start measuring after it beeps about 10 seconds after the last measurement and the ready to measure
9. rsus traditional sites e Axillary temperature readings only reflect skin temperature which may not indicate the internal body temperature e Rectal temperature often lag significantly behind internal body temperature changes especially at times of rapidly changing temperatures e Oral temperature is often influenced by eating drinking breathing through the mouth or the inability of the person to close his her mouth completely Normal body temperature Normal temperature refers to the body temperature of a healthy person It differs among individuals and is affected by environmen tal conditions such as time of day atmospheric temperature activity before measurement site of measurement e g ear mouth or armpit We recommend that you determine your normal body temperature by measuring several times under the same conditions How Does the Ear Thermometer Work The Ear Thermometer measures the infra heat generated by the eardrum and surrounding tissues Clinical research has shown that the ear is an ideal site for taking body temperature since the eardrum shares blood vessels with the hypothalamus the part of the brain that controls body temperature To help ensure accuracy the Ear Thermometer takes 6 measurements within one second and displays the average temperature Measuring difference for ear themometer for reference only According to the explanation of ASTM E1965 there might be some differences in reading results if th
10. te Sudden change of ambient temperature may influence the measurement accuracy For accurate measurement try to store the ear thermometer in the same room where you usually take your temperature For accurate measurement take the temperature while you relax Your temperature may increase after exercise or a bath The right ear reading may differ from the left ear Therefore always take the temperature using the same ear External factors may influence ear temperatures including when an individual has been lying on one ear or the other had their ear covered been exposed to very hot or very cold temperatures has just finished swimming or bathing has been wearing hearing aids or ear plugs Should any of the above mentioned situations occurs wait for 20 minutes prior to taking the temperature 2 Inserting batteries Your Ear Thermometer requires two AAA batteries To insert remove the battery cover by sliding it away from the probe as shown in fig 3 PREPARATION BEFORE USE continued e Place the battery in the battery compartment making sure that it is positioned correctly according to the polarities indicated on the thermometer Fig 4 e Replace the battery cover by sliding it into place Fig 5 3 Correct Holding Posture e Hold the main body as shown in fig 6 so that you can press the button with your index finger PREPARATION BEFORE USE continued In the following situations it
11. y injure the ear canal or the eardrum Do not use a portable phone near the thermometer when you are taking the temperature as it will cause the thermometer to malfunction Caution Do not disassemble or repair or remodel the ear scan Do not discard batteries into the fire When the Product Should Not be Used This thermometer is designed to take your body temperature through the ear canal only Do not use it for any other purpose Do not use the product on people suffering from ear diseases Do not use the product while the ear canal is wet e g after a swim or a bath This product is not waterproof Therefore keep the product dry at all times Do not operate the device outside the specified ambient temperature range 41 F 104 F 5 C to 40 C and humidity range 15 95 RH Do not store the ear thermometer outside the specified ambient temperature range 13 F 131 F 25 C to 55 C and humidity range 15 95 RH NOTES ON TEMPERATURE Why Measure in the Ear Clinical studies have shown that the ear is an excellent site for taking body temperature because the temperature taken in the ear reflects the body s core temperature Body temperature is regulated by the hypothalamus which shares the same blood supply as the tympanic membrane Changes in core body temperature are usually seen sooner in the tympanic membrane than in other places such as rectum mouth or under the arm Advantages of taking temperature in the ear ve

Download Pdf Manuals