Home

Spectra UL633-14 User's Manual

image

Contents

1. 17 CALIBRATION Checking Calibration of the Y and X Axes 1 Setup the laser 30 m 100 ft from a wall and allow it to level E e 2 Set the grade to 0 000 in both axes 3 Raise lower the receiver until you get an on grade reading for the Y axis Using the on grade marking notch as a reference make a mark on the wall ZE LE Note For increased precision use the fine sensitivity setting 1 5 mm 1 16 in on o the receiver a 4 Rotate the laser 180 Y axis toward the wall and allow the laser to re level 5 Raise lower the receiver until you get an on grade reading for the Y axis Using the on grade marking notch as a reference make a mark on the wall 6 Measure the difference between the two marks If they differ more than 3 mm at 30 m 1 8 inch at 100 feet the laser needs calibrating 7 After checking the Y axis rotate the laser 90 Repeat the above starting with the HN X axis facing the wall Kom Checking Calibration of the Z vertical Axis To check vertical calibration you need a plumb bob with at least 10m 30ft of string 1 Suspend the plumb bob in front of a house i e attached to a window frame whose window height is at least 10m 30ft 2 Setup the laser in vertical so thatthe laser beam strikes the receiver s on grade position at the top of the string 3 Look for any deviation using the receiver from the top of the string to the bott
2. Corrections up and down can be done using button 5 8 for left right corrections use button 6 7 Press and release the manual button to change the unit back to full automatic mode Beam Plunge Beam Plunge centers the rotor vertically and can be used to align the plumb beam to a desired vertical position e g when doing Interior layout Press and release the MENU button at the Standard Display and select Beam Plunge Pressing and releasing button 4 activates the Beam Plunge mode while the rotor checks the limits of the Y axis and stops at the center position Pressing button 3 ESC stops the movement and changes the unit into manual mode Corrections up and down can be done using button 5 8 for left right corrections use button 6 7 Press and release the manual button to change the unit back to full automatic mode Setting Menu Press and release the MENU button at the Standard Display and select Settings CH Press and release button 4 to open the Setting Menu select the desired function then press button 4 to open the selected submenu function OR start the selected function The Setting Menu offers the following functions se D ZA 7 SE an Pairing Mask Mode Grade Entry Grade Display Sensitivity R 1 yy CODE mut P HI Alert Information Set Password Password On Off RF Channel Pairing When in Settings press and release button 4 to open the Pairing menu The display shows the
3. If not already set to UL press Units button and then press Deadband or Audio button until UL is displayed Press Units button again to enter selection Press and release the Audio button display shows PAIR Press the Units button again the display shows PAIR and a rotating bar After completing PAIR OK will be displayed The UL633 pairs now automatically with the new receiver Press and release the Power button two times to exit the menu A laser symbol is lit to confirm the receiver works in UL mode Mask mode Select the Mask icon and press and release button 4 to open the Mask setting menu Depending on which side or corner the beam should be turned off the reguired sector can be selected Press and release the buttons 5 to 8 for moving a short flashing line around the mask mode symbol For selecting the sector where the bar is flashing press and release button 1 SET After setting the first sector button 1 changes to show CLR which offeres the capability of deleting the selected mask sector again Use button 5 to 8to move the flashing bar to other reguired areas and repeat the setting process When all areas have been set press button 4 to store the mask sector selection until the unit will be turned off Hask Sectors Hask Sectors DN Hinweis The unit always powers up with the mask mode deactivated default 15 Grade Entry Select the Grade Entry icon and press and release button 4 to open the Grade
4. Entry menu AA Buttons 6 7 can be used to toggle between Step and Go and Digit Select Press and release button 4 to confirm the selection Step and Go Digit Select Grade Display te Select the Grade Display icon and press and release button 4 to open the Grade Display menu LI P The desired Grade Display Mode Percent Permille Degree can be selected using the buttons 6 7 Gch Press and release button 4 to confirm the selected display mode D D O D a Sensitivity Selection Select the Sensitivity icon and press and release button 4 to open the Sensitivity menu The SE desired Sensitivity Low Mid Default and High can be selected using the buttons 6 7 Press and release button 4 to confirm the selected Sensitivity fk Hl alert Selection Select the HI icon and press and release button 4 to open the Hl alert menu The desired Hl alert 5 min Default 30 seconds and HI Off can be selected using the buttons 6 7 Press and release button 4 to confirm the selected Hl alert SHIN SESEC OFF 16 User Name Select the User name icon and press and release button 4 to open the User name menu One row for typing names in big font 15 and one row in small font 18 for letters or numbers are available Button 5 and 8 can be used to toggle between both rows Changing the characters can be done using the buttons 1 and 2 Pr
5. between these two points aligns the plumb beam automatically to the SF601 center point both axes and moves back to Z axis automatic mode while displaying the measured Z axis grade value Note When Automatic Spot Alignment and Automatic Spot Match have been completed the UL633 turns off the fan beam automatically Note With a quick press and release of the SF601 power button the fan beam lens at the UL633 will be activated deactivated while a previous activated auto mode will be exited SF601 Manual Display Mode With a quick press and release of the SF601 power button the fan beam lens at the UL633 will be activated deactivated while a previous activated automatic mode will be exited Manual Display Spot Search mode If the fan beam lens will be activated and no automatic mode has been started the SF601 is in manual display mode where the RED direction LEDs guide the user to the center position of the fan beam Note IR communication is disabled The direction LEDs work similar like using the pipe laser target e g if the left top LED is on the SF601 has to be moved to the left up position to bring the center hole into the center of the beam All 4 LEDs are solid red when the beam is centered 22 PROTECTING THE UNIT Do not expose the unit to extreme temperatures or temperature changes do not leave inside the car The unit is very robust and can resist damage if dropped even from tripod height Before continui
6. life Operating temp Storage temp Tripod attachments Dust and Water proof Weight Low voltage indication Low voltage disconnection 1 at 21 Celsius 2 under optimal atmospheric circumstances 3 along the axis 4 depending on sun light conditions Remote Control RC 603 Radio Operating ranget IR Operating range Power source Battery life Dust and Water proof Weight Spot Finder SF601 Operating range Power source Battery life Dust and Water proof Weight 24 0 5 mm 10 m 1 16 100 ft 10 arc seconds 1 0 mm 10 m 1 8 100 ft 20 arc seconds 0 900 rpm 5 preset sizes variable adjustment appr 400 m 1300 feet radius with detector red diode laser 650 nm Class 3A 3R lt 5mW appr 14 25 both axes not simultaneously 25 LCD indications and LED flashes up to 80 m 260 ft NiMH battery pack 35 hours NiMH 40 hours alkaline 20 C to 50 C 4 F to 122 F 20 C to 70 C 4 F to 158 F 5 8 x 11 horizontally and vertically IP67 3 1 kg 6 8 lbs LCD battery indicator unit shuts off up to 100 m 330 ft up to 80 m 260 ft 2 x 1 5V AA alkaline batteries 130 hours IP66 0 26 kg 0 4 Ibs up to 80 m 260 ft 4 x 1 5V AA alkaline batteries 30 hours IP67 0 43 kg 0 4 Ibs gt Trimble Spectra Precision Division 8261 State Route 235 Dayton Ohio 45424 6383 U S A 1 937 245 5010 Phone C E Gus 2012 Trimbl
7. select Fa a Reference Check Pressing and releasing button 4 starts the Reference Check considering the current temperature inside the housing While the rotor checks the correct position the rotation will be stopped Centering the Rotor Press and release the MENU button at the Standard Display and select Centering where the rotor will be centered 90 perpendicular to the bottom housing L d is Pressing and releasing button 4 starts the rotor centering function while the rotor checks the limits of both axes then it stops at the center position and changes the unit into manual mode Setting Menu Press and release the MENU button at the Standard Display and select Settings Press and release button 4 to open the Setting Menu select the desired function then press button 4 to open the selected submenu function OR start the selected function Please see the Setting Menu details at the end of the user guide Info T Press and release the MENU button at the Standard Display and select Info t Buttons 6 7 can be used to toggle between UL RC and Runtime Press and release button 4 to confirm the selection The UL RC information software version ID etc or the runtime of the UL will be displayed Runtines Overall 154324 About UL Feu AZA ID 46ESEEEDVESOAF AP Addie 115 343 175 166 IR Key 4866 About RC Few 66 261 ID 4469652640617573 el ER E IF Bey 4HH LT I IX b Press and releas
8. Error message Grade Match has Failed which can be deleted with button 4 OK The HL750 goes back to standard elevation indication a Manual Grade Match In Manual Grade Match the beam on both axes can be adjusted to the receiver s on grade position e g when other receivers as the HL750 are used The grade for the Y axis can be adjusted with button 5 8 while button 6 7 adjust the X axis During Manual Grade Match a crossed vial and angle symbol appear next to the continuously changing Y and X axis grade value After adjusting to the receiver s on grade position press button 2 OK to go back to automatic mode where the final grade value will be shown for both axes GM Note Pressing button 3 ESC exits Manual Grade Match and changes the unit to manual mode Automatic Axis Alignment Automatic Axis Alignment mode adjusts automatically the direction the grade axis is pointing to the receiver s location by an electronically Eg simulation of rotating the unit on its base to match the hub Using Axis T i O d Alignment the laser axes can be aligned to one or two direction hubs d up to 80 m 260 ft located on one or both axes at each side of the laser SEE 1 Set up the laser over the reference point 2 Place the grade rod with the attached HL750 receiver at the desired direction hub 3 Use the sighting guides on the top of the laser to align the laser to the receiver Turn the laser on the tripod unt
9. SF601 eingeschaltet wird durch kurzes Drucken der Ein Aus Taste die Fanbeam Linse aktiviert deaktiviert eine vorher gestartete Automatikfunktion wird sofort gestoppt LED s 2 LED1 solid green when SF601 is on and battery OK blinking red if battery voltage is 3 8V lt V bat lt 4V solid red if battery voltage is lt 3 8V SF601 turns off automatically after 5 min 3 Mode LED2 yellow solid automatic mode flashing none or lost signal off manual mode 4 Direction LEDs red Manual mode pointing towards the center of the plumb beam All 4 LEDs are solid red when the beam is centered Automatic Spot Lock mode solid for 5 min then LED s flash every 5 seconds Using the SpotFinder SF601 for vertical UL applications With the UL633 using IR connection the SF601 can be used in three different automatic modes Automatic Spot Alignment SpotLok and Spot Match and in addition in a manual display Spot Search mode to detect the plumb beam fan beam Automatic S pot Alignment SF601 guides the beam to the target point in the horizontal axis while the Z axis grade value will be maintained Used for first and second day alignment pipe laying applications 21 Using SpotLok mode like PlaneLok aligns and holds the plumb beam automatically to the SF601 center point both axes until exiting this mode Automatic Spot Match like Grade Match two existing elevation points will be connected to measure the grade value
10. UL 633 User Guide Bedienungsanleitung Manuel de l utilisateur Guida per l uso G ia del usuario Gebruikershandleiding Operat rshandbok Brugermanual Guia do Usu rio Bruksanvisning K ytt j n opas Instrukcja obs ugi PyKOBOACTBO nonb3o0BaTenA WA e www trimble com Trimble 1 ik hl A L WA i E E ki a J Printed in Germany Q104735 Rev A 01 12 Service and Customer Advice North Latin America Trimble Spectra Precision Division 8261 State Route 235 Dayton Ohio 45424 U S A 1 888 272 2433 Toll Free in U S A 1 937 482 0030 Fax www trimble com www spectraprecision com www spectra productivity com Africa amp Middle East Trimble Export Middle East P O Box 17760 JAFZ View Dubai UAE 971 4 881 3005 Phone 971 4 881 3007 Fax Europe Trimble Kaiserslautern GmbH Am Sportplatz 5 67661 Kaiserslautern GERMANY 49 6301 711414 Phone 49 6301 32213 Fax Asia Pacific Trimble Navigation Singapore PTE Ltd 80 Marine Parade Road 22 06 Parkway Parade Singapore 449269 65 6348 2212 Phone 65 6348 2232 Fax China Trimble Beijing Room 2805 07 Tengda Plaza No 168 Xiwai Street Haidian District Beijing China 100044 86 10 8857 7575 Phone 86 10 8857 7161 Fax www trimble com cn TABLE OF CONTENTS Introduction FOR YOUR SAFETY COMPONENTS How to use the Laser System Powering the Laser RC603 Radio IR Remote Control Turning On O
11. ain 6 Special MENU Features Menu Functions Radio controlled Press and release button 1 at the Standard Display to enter the MENU The menu offers always only the features which can be selected depending on the setup horizontal or vertical The icon of the selected function will be highlighted A down arrow at the the right site indicates that the user can scroll down through the menu using the button 8 down arrow After going to the next menu row an up down arrow at the the right site indicates that the user can scroll up down through the menu 4 different screens using the buttons 5 8 up down arrows Pressing and releasing button 3 changes the unit always back to the standard or previous display Press and release the buttons 6 7 until the desired icon at the selected menu row is highlighted Press and release button 4 to open the submenu OR start the selected function Menu functions when set up horizontal Plane Lok Spot Search Centering Ge he hes Ss Menu functions when set up vertical Spot Align Spot Hatch Reference Check Settings Li al LL ee ee ee ee ti ofle Menu Functions IR controlled If the RC603 is paired with a transmitter and the radio connection doesn t work e g through a pipe the IR connection offers the following functions f IE p Ze sch poe Zi CH E Bi s n tn r 7 11 A ef Gi RC 99 291 Cer Get Ge Je 4 pv 8 Se zi ri E au 118 33 175 184 j Spot Align Spot Hatch F
12. airing MENU Sel IL LT Let 4 Press and release the MENU button at the Standard Display Pressing and releasing button 3 changes the unit always back to the standard or previous display Press and release the buttons 5 to 8 until the desired icon is highlighted Press and release button 4 to open the submenu OR start the selected function Note Pairing function is needed to pair an already paired remote with a new transmitter The new transmitter has to be set to the pairing dialog for this operation Otherwise the pairing can not be Successful processed The pairing information of the previous pairing is still stored in the previous paired transmitter and should be deleted in the pairing dialog of this transmitter Note If a remote is paired with a transmitter the IR signals of the remote in case of an interrupted radio connection will transmitted in a private mode so that only the paired transmitter can received these IR commands Automatic PlaneLok mode The PlaneLok mode can be activated in horizontal and vertical automatic and manual mode In PlaneLok mode when set up horizontal the beam will be locked to a fixed elevation point up to 80 m 260 ft located on one or both axes at each side of the laser For keeping vertical alignments fixed to a direction point PlaneLok can be used in both directions on the X axis 1 Set up the laser over the reference point 2 Attach the HL750 receiver to a grade rod Place th
13. apacity resulting in loss of performance and shortened life expectancy RC603 Radio IR Remote Control Powering the RC603 1 Open the battery door using a coin or similar pry device to release the battery door tab on the RC603 RC603 will be shipped with alkaline batteries Rechargeable batteries can be used optional but need to be charged externally 2 Insert two AA batteries noting the plus and minus diagrams inside the battery housing 3 Close the battery door Push down until it clicks into the locked position Turning On Off the Radio IR Remote Control The radio IR remote control is a hand held device that allows you to send operational commands to the laser from a remote location Press the power button to turn on the radio IR remote control A T and additional vertical bars appear in the right corner of the remote s top display line indicating the radio connection status between the laser and the remote control If the RC603 is outside the radio operating range the remote switches automatically into the IR connection capability Note When the remote control is initially turned on the standard display model number and software version appear for the first 3 seconds then the axes symbols and last entered grade for each axis briefly appear in the LCD With every button press the LCD backlight is activated and turns off automatically if no button is pressed for 8 seconds To turn off the radio remote c
14. beam can be detected automatically and manually using the additional S potF inder For Your Safety For hazardless and safe operation read all the user guide instructions LASER RADIATION AVOID DIRECT EYE EXPOSURE CLASS 3A 3R LASER PODUCT Use of this product by people other than those trained on this product may result in exposure to hazardous laser light Do not remove warning labels from the unit The UL633 is Class 3A 3R lt 5mW 600 680 nm Never look into the laser beam or direct it to the eyes of other people Always operate the unit in a way that prevents the beam from getting into people s eyes e If initial service is required which results in the removal of the outer protective cover removal must only be performed by factory trained personnel Caution Use of other than the described user and calibration tools or other procedures may result bg in exposure to hazardous laser light Caution Using different than described at the UL633 user guide may result in unsafe operation COMPONENTS Keypad LCD Display Handle Rotor with fan beam lens Sunshade Axes Alignment Marks Sighting Guides Scope Mounts Battery door Rubber Cover Recharge J ack 5 8 x 11 Tripod Mounts Rubber Feet Turnable Legs Plus and Minus Battery Diagrams fm DOC HOA EI Oo HOW TO USE THE LASER SYSTEM POWERING THE LASER Batteries WARNING Ni MH batteries may contain small amounts of harmful substances Be sure
15. currently paired units up to two receivers and two remote controls If already 2 remote controls have been paired one of them has to be deleted using button 1 CLR Turn on the RC603 and select the Pairing menu and press button 4 The UL633 pairs now automatically with the new remote control Pairing the transmitter with remote control The chain symbol at button 1 indicates the remote has never been paired before which means no radio connectivity is given Pressing the pairing button 1 will initiate a pairing request The transmitter has to be in pairing mode as shown above Pairing Ni RCI 118 93 10 104 RC GZ 9 717 RC m HLI 75005558 UEL Le Gil Note Make sure that pairing mode is selected only at one transmitter which is within the radio range of the remote during a pairing reguest Otherwise pairing procedure can be confused Pairing the transmitter with receiver To pair the transmitter and the receiver select Settings and press and release button 4 to open the Pairing menu The display shows the currently paired units up to 2 receivers If already 2 receivers have been paired one or both of them have to be deleted using button 1 CLR PSA SS HL2 75005529 Next turn on the receiver then press and hold the Deadband A and the Audio B buttons for two seconds After two seconds the display shows MENU first then RDIO Press and release the Units C button display shows the current radio mode
16. d automatically to one direction hub up to 80 m 260 ft located in front of the plumb beam 1 Set up the laser over the start point e g at the first pipe Ver or trench start point dl K 2 Place the SF601 Spot Finder at the last pipe or end of 2p Ok D I the trench Al O 3 Press and release the MENU button at the Standard oc HENI TEST Display select Spot Match and start the function using button 4 fan beam will be activated Note Spot Match can also be started via infrared using the RC603 Note The display falls back to the standard display while a Spot Finder and angle symbol is flashing The plumb beam will be automatically aligned to the center of the SF601 Elk 4 When Spot Match has been completed the fan beam will be turned off and the UL calculates the grade value between both elevation points The calculated grade value will be displayed at the UL s and RC s display Note Automatic Spot Match can be exited any time by pressing and releasing button 3 ESC 13 Line Scan Line Scan centers the rotor horizontally and can be used to align the plumb beam to a desired horizontal position Press and release the MENU button at the Standard Display and select Line Scan Pressing and releasing button 4 activates the Line Scan mode while the rotor checks the limits of the X axis and stops at the center position Pressing button 3 ESC stops the movement and changes the unit into manual mode
17. e Navigation Limited All rights reserved www trim ble com PN 0104735 Rev A 01 12 DECLARATION OF CONFORMITY Please disregard the declaration of conformity within the manual Following is the valid declaration We Trimble Kaiserslautern GmbH Declare under our sole responsibility that the products UL633 and RC603 SF601 To which this declaration relates is in conformity with the following standards EN300 440 2 V1 1 1 2004 EN301 489 03 V1 4 1 2002 EN301 489 01 V1 4 1 2002 EN50371 2002 EN60825 1994 A1 2002 A2 2001 following the provisions of directive R amp TTE 1999 5 EC The managing director ELECTRO MAGNETIC COMPATIBILITY Declaration of Conformity This digital apparatus does not exceed the Class B Limits for radio noise for digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications This device complies with part 15 off the FCC rules Operation is subject to the condition that this device does not cause harmful interference Note The product been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception w
18. e receiver at the second point and adjust it to the On grade position The receiver should be permanently mounted at this location and at the desired elevation 3 Use the sighting guides on the top of the laser to align the laser to the receiver Turn the laser on the tripod until it is roughly aligned to the receiver s position the alignment range for both axes is 40 4 Press and release the MENU button at the Standard Display and select PlaneLok In vertical mode PlaneLok can be started immediately by pressing button 4 Z a Am Horizontal setup Vertical setup 5 When set up horizontally press and release button 4 to open the PlaneLok submenu select the desired PlaneLok axis then press button 4 to start PlaneLok D D D Note The laser starts to search for the receiver Aflashing Receiver and Lock symbol appears at the selected axis and becomes solid when PlaneLok has been completed IS Note When used in vertical mode the receiver has to be placed with the photocell on the bottom side The HL750 display shows a flashing PL during the time the laser is searching and adjusting the beam to the on grade position When PlaneLok is complete PL stops flashing at the HL750 display il lt Note The laser continues to servo to the receiver s signals 6 Exiting of PlaneLok can be done by pressing button 3 ESC Automatic Grade Match The Grade Match mode can be activated in hori
19. e the MENU button at the Standard Display and select Service Buttons 6 7 can be used to toggle between Calibration Y and Calibration X OR Calibration Z when setup vertically L JI LEI TO TO Ki Ki Press and release button 4 to confirm the selection The calibration at the selected avis starts the field calibration procedure in Md CG Calibration Calibration amp Calibration 7 Initialization Initialization Initializatior OH CC M TES 11 The RC603 Service menu offers additional features RF IR options Press and release button 4 to confirm the selection and select one of the following options RF On IR auto gt Radio on all times IR will be activated automatically after radio connection 1 ee has been lost RF Off IR On gt Radio turned Off IR always activated RF On IR Off gt Radio turned On IR always Off RF Connectivity Press and release button 4 to get a status of the current Radio connectivity RF Connectivity Current Labs Middle Box L Lk Special Features Vertical Setup Z Axis Automatic Spot Align The Spot Finder SF601 guides the plumb beam to the target point in the horizontal axis while the Z axis grade value will be maintained Used for first and second day alignment pipe laying applications Using Spot a e A CN ETI ra Alignment the plumb beam can be aligned automatically RO FH vi to one directio
20. ess and release button 4 to confirm the selected user name The display falls back to the main menu Any time the unit will be powered up the User info will be displayed for couple seconds User Hane ae Pee Trimble K Toun Other Inter d t De Hl 71414 450 G6 381 A11414 ESS al ee ROUE Trimble PEN Set Password Select the Set Password icon and press and release button 4 to open the Password menu Use dam Button 1 to 8 to type in a password containing of 4 digits and repeat the password at the second CODE row Press and release button 4 to store the selected password unit falls back to the standard menu After powering up the unit the standard display comes up if the correct password will be entered otherwise the unit turns off automatically Set Passuord Set Passuord Nenu 8 Neu SET Confirm Confirm B Password On Off Select the Set Password ON Off icon and press and release button 4 to open the Password menu dam Buttons 6 7 can be used to toggle between Password On and Password Off if a Password has DN DEF been entered before Press and release button 4 to confirm the selection Password on Password off Radio RF Channel Select the RF Channel icon and press and release button 4 to open the Radio Channel menu S The desired RF Channel Low Mid Default and High can be selected using the buttons 6 7 4 Press and release button 4 to confirm the selected RF Channel T FU EU LUM MID HIGH
21. et to 0 and then starts changing in 1 increments Press and hold button 5 or 8 up down for changing Y Z axis grade value press and hold buttons 5 8 simultaneously starts Y Z axis quick change mode where the grade value in front of the comma will be set to 0 and then starts changing in 1 increments Note The speed of the grade value change increases with the amount of time the button is held down Note The grade value for both axes increases in 1 00 increments When the grade value for either axis reaches its highest amount the grade value switches to the lowest value for that axis For example the value switches from 25 to 25 The laser will self level to the required grade position after confirming the grade change with button 4 Note The bubble symbols at the laser s LCD will flash until the laser has been self leveled to the requested grade position X Y Z grade entering Digit Select mode Quickly press and release button 2 starts the grade entering mode Both grade values will be shown Press release button 1 gt quick set to 0 Press release button 2 gt change the sign in front of the grade value Press release button 3 gt return to the standard display Quickly press and release button 4 to confirm the selected grade value and return to the standard display d Pio chee d eo PH lt 25 8884 lt vi ER 16 000 gt Press and release button 5 or 8 down or up to move the cursor to t
22. ff the RC603 LASER SETUP Turning On Off the Laser Features and functions Standard Features X Y Z grade entering mode Using the Rotation mode Using the Scan mode Manual mode Special MENU Features Menu Functions Radio controlled Menu Functions IR controlled Automatic PlaneLok mode Automatic Grade Match Manual Grade Match Automatic Axis Alignment Manual Spot Search mode Activating Deactivating Standby mode Start Reference Check Centering the Rotor Setting Menu Info Service menu Special Features Vertical Setup Z Axis Automatic Spot Align Z axis Automatic Spot Lok Z axis Automatic Spot Match Line Scan Beam Plunge Setting menu details Pairing Pairing the transmitter with remote control Pairing the transmitter with receiver Mask mode Grade Entry Grade Display Sensitivity Hl alert selection User Name Set Password Password On Off Radio RF Channel CALIBRATION Checking Calibration of the Y and X Axes Checking Calibration of the Z vertical Axis Troubleshooting SF601 Spot Finder User Guide PROTECTING THE UNIT CLEANING AND MAINTENANCE PROTECTING THE ENVIRONMENT WARRANTY TECHNICAL DATA 8 NN zl NO OO OO Ln U P P P W A WW MM N Introduction Thank you for choosing one of the Spectra Precision Lasers from the Trimble family of precision lasers The universal laser is an easy to use tool that offers accurate horizontal vertical and sloped laser reference up to 1300 ft 400 m away using a receiver The plumb
23. he X or Y axis not used in Z mode Pressing and releasing button 6 or 7 right or left moves the cursor to the right left Use button 1 or 2 Plus or Minus to set the desired digit The laser will self level to the required grade position after confirming the grade change with button 4 RA OH RPO al lt 05 000 lt 23 808 16 D it 16 088 Note The bubble symbols at the laser s LCD will flash until the laser has been self leveled to the requested grade position Using the Rotation mode Repeatedly pressing the button 4 toggles through 0 80 200 600 900 rpm regardless if the unit O is in automatic or manual mode At 0 rpm the beam stops automatically close to the Y axis center position pipe laying over the top When set up horizontally in automatic or grade mode using buttons 5 8 increases decreases rotor speed from 0 to 80 and then up to 900 rpm continuously in 10 rpm increments Pointing mode At 0 rpm buttons 6 7 move the beam to the left right side When set up vertically at 0 rpm button 5 8 move the beam clockwise counterclockwise Note Press and hold button 4 for three seconds to change the unit from rotation mode default into scan mode Using the Scan mode Press and hold button 4 at the Standard Display for three seconds to change the unit into scan mode CE Ouickly press and release button 4 to toggle between the pre selected scan sizes 5 15 45 90 180 degrees and 0 regardle
24. hich can be determined by turning the product off and on The user is encouraged to try to eliminate the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the product and the receiver e For more information consult your dealer or an experienced radio television technician Caution Caution Changes or modifications to the product that are not expressly approved by Trimble could void authority to use the equipment 25
25. il it is roughly aligned to the receiver s position the alignment range for both axes is 40 4 Press and release the MENU button at the Standard Display and select Axis Align 5 Select the desired axis then press button 4 to start Axis Align Note Adjusting the receiver into the beam before starting the automatic Axis Alignment reduces the time needed for finishing the alignment Selecting the menu icon View Axis Angle shows the alignment angle after an axis alignment has been completed This function can be used to measure an angle difference between two direction hubs in a range up to max 80 by performing two axis alignments in sequence Vieu Align Angles Edit Align fingies Angle Ki 8 980 4 Axis 06 00 ais Y Axis 88 A84 Angle T Hiri i CSA UN koi A M LG D gt gt Cr Ka ie The menu icon Axis Angle Input selection allows to dial in an axis angle where the axis direction will be aligned too after a first axis alignment has been done Two rows are available for typing in axis angle values Button 5 and 8 can be used to toggle between both rows Changing the sign and numbers can be done using the buttons 1 and 2 Press and release button 4 to confirm the selected axis angles The axes will be adjusted while the display falls back to the main Menu Press and release button 3 ESC to exit the Angle functions Manual Spot Search mode The Spot Search mode i
26. mb beam can be aligned automatically to one direction hub up to 80 m 260 ft located in front of the plumb beam 1 Set up the laser over the start point BOY 2 Place the SF601 Spot Finder at the second reference point E7 lt 3 Press and release the MENU button at the Standard Display select Spot Lok and start the function using button 4 fan beam will be activated MENU LESC Note Spot Lok can also be started via infrared using the RC603 Note The display falls back to the standard display while a Spot Finder and lock icon is flashing The plumb beam will be automatically aligned to the center of the SF601 Co 4 After Spot Lok is complete all 4 red LEDs at the SF601 are on and the icons stop flashing The transmitter s plumb beam is always checking for perfect alignment to the center of the SF601 All 4 LEDs flash every 5 seconds to confirm the correct alignment Note Automatic Spot Lok can be exited any time by pressing and releasing button 3 ESC Z axis Automatic Spot Match Automatic S pot Match can be used for measuring an unknown grade value between two existing elevations e g in an existing pipe which needs to be replaced or an open trench with an unknown grade value The plumb beam will be automatically aligned to the SF601 center point Z and X axis and switches back to automatic Z axis grade mode while displaying the measured Z grade value Using Spot Match the plumb beam can be aligne
27. n hub up to 80 m 260 ft located in front aft Kik GER of the plumb beam f i L LI manhole ring MENU an Te Tu 2 Adjust the display bubble to the centered position 3 Turn on and attach the SF601 Spot Finder at the desired direction hub 4 Press and release the MENU button at the Standard Display select Spot Align and start the function using button 4 fan beam will be activated 1 Set up the laser over the start point e g at the first Note Spot Align can also be started through the pipe using the RC603 via infrared Note The display falls back to the standard display while a Spot Finder symbol is flashing D The plumb beam will be automatically aligned to the center of the SF601 5 After alingment is complete all 4 red LEDs at the SF601 are on the plumb beam will move vertically to the previous dialed in Z axis grade value Note Automatic Spot Align can be exited any time by pressing and releasing button 3 ESC 12 Z axis Automatic Spot Lok Automatic SpotLok like PlaneLok can be used to align and hold the plumb beam automatically to the SF601 s center point and continuously adjusting the Z and X axis until exiting this mode The UL looks always to the center position of the SF601 and re adjusts the beam immediately to the center to avoid any setup alignment drift caused by vibrations or temperature influences e g when working on concrete pads facade applications Using Spot Lok the plu
28. ng your work always check the leveling accuracy See Checking Calibration section The laser is water proof and can be used indoors and outdoors CLEANING AND MAINTENANCE Dirt and water on the glass parts of laser or prism will influence beam quality and operating range considerably Clean with cotton swabs Remove dirt on the housing with a lint free warm wet and smooth cloth Do not use harsh cleansers or solvents Allow the unit to air dry after cleaning it PROTECTING THE ENVIRONMENT The unit accessories and packaging ought to be recycled This manual is made of non chlorine recycling paper All plastic parts are marked for recycling according to material type Do not throw used batteries into the garbage water or fire Remove them in compliance with environmental requirements Hinweis fur Kunden in der EU Notice to Our European Union Customers For product recycling instructions and more information please go to www trimble com environment summary html Recycling in Europe To recycle Trimble WEEE Call 31 497 53 2430 and ask for the WEEE Associate or Mail a request for recycling instructions to Trimble Europe BV c o Menlo Worldwide Logistics Meerheide 45 5521 DZ Eersel NL Warranty Trimble warrants the UL633 to be free of defects in material and workmanship for a period of 5 years Trimble or its authorized service center will repair or replace at its option any defective part or the entire product f
29. om of it If the deviation is more than 1mm lt 1 16 in the vertical axis needs calibrating Note If calibration is required please refer to the calibration instructions on our Trimble website www trimble com support shtml 18 Troubleshooting Any error message can be deleted with a short press of button 4 OK The table shows the related description and possible solutions The next service center should be contacted if a different error message as shown at the table will be displayed Erorcodes Description Solution Temporary EEprom problem Repeat pairing and re enter the customer settings HI alert Unit Heigt changed Check laser beam elevation after deleting the HI alert Mechanical Limit during Axis Alignment Grade Match or Spot Match Re align the closer to the alignment point check if existing slope is above 25 Rake Angle Limit Re align the unit closer to the alignment point Laser beam blocked No receiver Receiver not available for single axis automatic function No receivers Both receivers are not available for automatic alignment function No receiver The laser searched for the receiver but could not find it Lost Receiver The laser searched and found the receiver but then lost it 141 Time Out Function could not be completed in the allowed time Make sure there are no obstacles between the transmitter and the HL750 or SF601 Check radio operating range connection check s
30. ontrol press and release the power button Note 5 minutes after the last button press the remote control turns off automatically LASER SETUP Position the laser horizontally tripod mount and rubber feet downward on a stable platform wall mount or tripod at the desired elevation The laser recognizes automatically whether it is used horizontally or vertically when switched on Turning On Off the laser Press the power button to turn On Off the laser Note Depending on the setup horizontal or vertical and if a grade value has been dialed in the unit starts the temperature reference check while the thermometer symbol is flashing E Wi 25 000 mazi 10 8804 BOE lt i 25 000 10 000 ai MENU d Aid lt B5058 me MENU 45 B 577 ino lt 05054 CIT When the temperature reference check has been finished the standard display appears and the bubble symbols flash until self leveling has been completed If the self leveling can t be finished based on the selected sensitivity an error message appears A bubble symbol helps to adjust the unit at the cross axis when set up vertical for automatic Spot Align or in vertical manual mode Features and Functions Standard Display The remote control mirrors the functionality of the UL keypad Battery status laser HI alert function is activated Mask selection Rotation speed Scan angle Fan Beam is activated Battery Status Remote Control
31. or which notice has been given during the warranty period If required travel and per diem expenses to and from the place where repairs are made will be charged to the customer at the prevailing rates Customers should send the product to Trimble Navigation Ltd or the nearest authorized service center for warranty repairs or exchange freight prepaid Any evidence of negligent abnormal use accident or any attempt to repair the product by other than factory authorized personnel using Trimble certified or recommended parts automatically voids the warranty Special precautions have been taken to ensure the calibration of the laser however calibration is not covered by this warranty Maintenance of the calibration is the responsibility of the user The foregoing states the entire liability of Trimble regarding the purchase and use of its equipment Trimble will not be held responsible for any consequential loss or damage of any kind This warranty is in lieu of all other warranties except as set forth above including any implied warranty merchantability of fitness for a particular purpose are hereby disclaimed This warranty is in lieu of all other warranties expressed or implied 23 TECHNICAL DATA UL633 Leveling accuracy gt Grade accuracy Rotation Scan mode Operational area Laser type Laser class Self leveling range Grade range Y X Grade range Z Leveling indicators Radio range HL750 Power source Battery
32. s used for detecting the plumb beam manually using the S pot Finder ot SF601 and can be activated in horizontal and vertical automatic and manual mode Press and release the MENU button at the Standard Display and select Spot Search Pressing button 4 activates the fan beam while the rotation speed changes to 900 rpm and the unit goes back to the standard display The 4 red LEDs around the center hole guide the user to the plumb beam s center position all 4 LEDs on gt confirmation the SF601 has been set to the correct center position Note Manual Spot Search can also be activated any time by turning on the Spot Finder SF601 Turning Off the SF601 deactivates the Spot Search mode immediately by deactivating the fan beam Activating Deactivating Standby mode F Press and release the MENU button at the Standard Display and select Standby S Pressing and releasing button 4 activates the Standby mode The self leveling will be stopped and the beam will be turned off while the HI alert is still active The display shows the standby symbol and the Level Standby LED flashes red every 5 seconds To deactivate Standby mode and restore full operation of the laser press and release button 4 Standby E TI Ai G e e E ET ees 10 Start Reference Check Before starting some grade work which is very sensitive an additional Reference Check can o ae be started manually Press and release the MENU button at the Standard Display and
33. ss if the unit is in automatic or manual mode When working in horizontal automatic mode press and hold button 5 8 to increase decrease the line size in 5 degrees increments Press and hold button 6 7 moves the scan line to the right left direction When used in automatic vertical mode pressing and holding button 5 8 moves the scan line counterclockwise clockwise When set up vertical pressing and holding button 6 7 moves the scan line into the right left direction regardless if in automatic or manual mode Note Press and hold button 4 for three seconds to change the unit back to rotation mode default mode Manual mode Pressing and releasing button 3 at the Standard Display activates deactivates the manual mode regardless if set up horizontal or vertical Manual mode is indicated by horizontal lines next to the axes symbols An additional bubble helps to adjust the laser on the cross axis when set up vertical ROM Be gee aee ot oh NI L ore In Manual mode horizontal the Y axis can be sloped by pressing the Up 5 and Down Arrow 8 buttons on the laser s keypad or the remote control Additionally the X axis can be sloped by pressing the Left 6 and Right 7 Arrow buttons on the laser or remote control In vertical mode the up and down arrow buttons adjust the Z axis slope and the left and right arrow buttons align the laser beam to the right left side To resume automatic self leveling mode press the manual button ag
34. table laser setup Make sure the receiver is on and paired Make sure both receivers are on and paired Check the operating range for auto function and restart the auto alignment Check the operating range for auto function and restart the auto alignment X Y or Z level sensor defect Contact service center 19 SF601 User Guide SF601 attached to a grade rod using the standard receiver clamp SF601 attached to the optional pipe laser target base Components SF601 SF601 Slider Center Hole Power Button Bubble Vial Battery LED Mode LED Red Direction LEDs IR transmitters receivers 10 Marking notches front and back 11 M6 Clamp Mount 12 Battery door 13 Latch for Battery Door 14 Release Tab Slider O00 AO ES 20 Powering the SF601 1 Open the battery door pulling the battery door latch The SF601will be shipped with alkaline batteries Rechargeable batteries can be used optional but need to be charged externally 2 Insert four AA batteries noting the plus and minus diagrams inside on the battery door 3 Close the battery door Push down until it clicks into the locked position SF601 Features and Functions 1 Power Mode Button Press and release the power button to turn ON the SF601 All display LED s will light for 1 0 sec Press and hold power button for gt 1 sec to turn OFF the SF601 After 1 sec all display LED s will light 1 0 sec Note Wurde der
35. tatus Radio Connectivity Button 1 DISK L en Button 2 Button 3 Button 4 Button 5 8 Button 6 7 Button 9 Quickly press and release starts the MENU entry Quickly press and release starts the grade entering mode Quickly press and release activates deactivates the manual mode Quickly press and release to toggle through the pre selected rotation speeds Press and hold for three seconds changes the unit into scan mode When in scan mode quickly press and release button 4 toggles through the pre selected scan sizes up down arrow buttons left right arrow buttons ON OFF button press for 1 second to turn on the unit press and hold for 2 seconds to turn off the unit 4605 Leveling Standby LED green red Standard Features X Y Z grade entering Step and Go mode Quickly press and release button 2 starts the grade entering mode Both grade values will be shown Press release button 1 gt grade reverse Y Press release button 2 gt grade reverse X Press release button 3 gt return to the standard display Quickly press and release button 4 to confirm the selected grade value and return to the standard display ea S lt Y 23 000 425 000 ah 8080 X 08 0001 gt Press and hold button 6 or 7 left right to change X axis grade value after the comma press and hold buttons 6 7 simultaneously starts X axis quick change mode where the grade value in front of the comma will be s
36. to charge the battery before using it for the first time and after not using it for an extended length of time Charge only with specified chargers according to device manufacturer s instructions Do not open the battery dispose of in fire or short circuit it may ignite explode leak or get hot causing personal injury Dispose in accordance with all applicable federal state and local regulations Keep the battery away from children If swallowed do not induce vomiting Seek medical attention immediately Recharging the Batteries The laser is shipped with a rechargeable Ni MH battery pack Note The approximate charge of the batteries is shown at the left top side of the LCD The charger requires approx 10 hours to charge empty rechargeable batteries For charging connect the plug of the charger to the recharge jack of the battery pack New or long time out of use rechargeable batteries reach their best performance after gt being charged and recharged five times For Indoor applications the charger can be used as a power supply for the UL Net i The batteries should only be charged when the laser is between 50 F and 104 F 10 C to Alkaline batteries can be used as a backup Insert 4 D cell batteries noting the plus and minus diagrams inside the battery housing 40 C Charging at a higher temperature may damage the batteries Charging at a lower temperature may increase the charge time and decrease the charge c
37. zontal automatic and manual mode In Grade Match mode the laser can be used to measure the existing grade value between two known elevation points up to 80 m 260 ft located on one or both axes at each side of the laser 1 Set up the laser over the reference point 2 Attach the HL750 receiver to a grade rod Check the laser s elevation next to the laser then position the receiver at the second point WITHOUT changing the receiver s elevation on the rod 3 Use the sighting guides on the top of the laser to align the laser to the receiver Turn the laser on the tripod until it is roughly aligned to the receiver s position the alignment range for both axes is 40 4 Press and release the MENU button at the Standard Display and select Grade Match A 5 Select the desired Grade Match axis then press button 4 to start Grade Match Y YA ES A Note The laser starts to search for the receiver A flashing Receiver and angle symbol appears at the selected axis and disappears when Grade Match has been completed T While the laser is searching and adjusting the beam to the on grade position the HL750 display shows a flashing GM When Grade Match has been completed the HL750 goes back to the standard elevation display The remote control as well as the laser will display the final measured grade value Ad Note If Grade match can t be completed by checking the limits the laser comes with an

Download Pdf Manuals

image

Related Search

Related Contents

Hoover Fusion U5180-900 User's Manual  Samsung UN60F7500AFXZA User's Manual  E1T IP1897 rev. 2007-06-26 I P E D F GB OPEN  Machine à Graver - Mode d`emploi v1.1  EPPCBug™ Diagnostic Firmware User's Guide - ps  13290-13305 SuperSeat IB 2-26-13  Biointerpreter User Manual #259, 4th Cross, “Apurva Buildings”, 80  Manual Lijadora Orbital_380W  innova service manual ver. 5  Approx APPUSBCAR mobile device charger  