Home

Siemens SIMATIC NET CP 343-1 User's Manual

image

Contents

1. STOPPING STOP with internal error E g O STOP hd 0000 8 Product information CP 343 1 C79000 Z8964 C038 05 english STOP LED RUN LED SF LED CP operating mode yellow green red sali Salir AS Module fault system error 9 9 Legend lit co off flashing Note Read the explanations of the operating modes in the NCM S7 for Industrial Ethernet manual 8 Controlling the Operating Mode There are three ways in which you can control the mode of the CP 343 1 as follows Mode selector e From a PG PC You can also control the modes using the configuration software in STEP 7 as follows NCM S7 Diagnostics for Industrial Ethernet see 8 SIMATIC Manager CP343 1 PLC Operating Mode Mode Selector With the mode selector you can set the following modes e Switch from STOP to RUN In the RUN mode all communication services are available The CP modes can only be controlled using NCM S7 or the SIMATIC Manager when the selector is set to RUN e Switch from RUN to STOP The CP changes to the STOP mode In the STOP mode only the configuration and diagnostic functions are available on the CP 343 1 Product information CP 343 1 9 C79000 Z8964 C038 05 english Note Read the sections about downloading configuration data to the CP in the NCM S7 for Industrial Ethernet manual 8 1 4 Further Information on Operation Downl
2. us by post or fax Product information CP 343 1 1 C79000 Z8964 C038 05 english Notes for the Reader Safety Guidelines A The reproduction transmission or use of this document or its contents is not permitted without express written authority Offenders will be liable for damages All rights including rights created by patentgrantor registration of a utility model or design are reserved Siemens AG 2 This manual contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equipment These notices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger Note draws your attention to particularly important information on the product handling the product or to a particular part of the documentation Caution indicates that minor personal injury or property damage can result if proper pre cautions are not taken Warning indicates that death severe personal injury or substantial property damage can result if proper precautions are not taken Danger indicates that death severe personal injury or substantial property damage will result if proper precautions are not taken Copyright O Siemens AG 1998 1999 All rights reserved Disclaimer of Liability We have checkedthe contents of this manual for agreementwiththe hardware and software described Since deviations cann
3. 1 2 1 Characteristics of S7 Communication o oooocoronooo 1 2 2 Characteristics of ISO Transport Connections 1 3 Displays and Mode Selector 0 00 cee ees 1 4 Further Information on Operation 0 cece eee eee RO N _ 3 oNNN 2 Installati n ii AA A 2 1 Module Accessories 00 00 ccc ett eee 22 ProcedulS ri eccac cieiid detains Geis tha ee ESS Gea ek 2 3 Attaching the CP 343 1 to Industrial Ethernet an 3 Technical Data scarico orar esac 3 1 General Technical Data 0 00 ccc eee 32 PINOUT teed iat AA tonne Bae ees A Dnt bce ws deen T a es 3 3 Notes on the CE Approval of SIMATIC NET Products h b 333 4 Referenc s usaras a ees beens eee a Compatibility with the Previous Version The version of the CP 343 1 described here is functionally compatible with and can be used to replace the CP 343 1 with order number 6GK7 343 1BA00 0XEO ver sion 6 The CP 343 1 decribed here has more functions Refer to the information in Section 1 1 Reply Form at the end of this product information We would like to know the purpose for which you are using this module and would also like to know your opinion of the module and the documen tation You can help us to provide you with better support and to further 4 improve the product We would be grateful if you would complete the reply form and return it to
4. Industrial Ethernet You re quire STEP 7 with the following version of NCM S7 for Industrial Ethernet abbreviated to NCM IE below Table 1 Version STEP7 NCM IE V2 x to V5 x Functionality of the CP 343 1 The same functionality is available as with the previous versions of the CP e Configuration data created with these STEP 7 or NCM versions can be downloaded to the CP 343 1 V5 x SP2 or higher The full functionality including the extended functions as listed in Section 1 1 can be used Information about the required service pack SP2 is available on the Internet at http www ad siemens de csi net 1 1 Characteristics Services The CP 343 1 supports the following communication services e S5 compatible communication with SEND RECEIVE interface via ISO transport connections FETCH WRITE services passive according to the S5 protocol via ISO transport connections and ISO on TCP connections e S7 communication with PG functions Operator control and monitoring functions Data exchange using communication function blocks PG functions Using the PG functions modules such as the FM 354 or FM 355 can be accessed via the CP extended PG functions Product information CP 343 1 C79000 Z8964 C038 05 english Note If there is a diagnostic connection to the CP via the CPU configuration data cannot be downloaded automatically to the CP by the CP
5. M ITP installation cable Figure4 Attaching the CP343 1 to Industrial Ethernet with TP Optical Switch Module OSM or Hub e Optical Industrial Ethernet using an AUI attachment Connection of the CP 343 1 TCP to Industrial Ethernet is also possible using an optical transceiver with an AUI interface CP 343 1 Optical module Star coupler 727 1 Connecting cable Leer Fiber optic cable Figure5 Attaching the CP 343 1 to Industrial Ethernet with AUI Optical Transceiver 14 Product information CP 343 1 C79000 Z8964 C038 05 english 3 Technical Data 3 1 General Technical Data Dimensions and Weight Dimensions module in casing H x W x D mm Weight 125x80x120 approx 750 g Voltage Current Operating Conditions Power supply Current consumption from the S7 300 backplane bus from the external 24 V supply Permitted ambient temperature Specifications according to 7 must be adhered to when operating an S7 300 tier horizontal installation vertical installation Altitude 5 V DC 5 24 V DC 5 70 mA 0 6 A 0 to 60 C 0 to 40 C up to 3000m above sea level All the information in 7 in the Section General Technical Data regarding the following topics also applies to the CP 343 1 e Electromagnetic compatibility e Transportation and storage conditi
6. SIEMENS SIMATIC NET Produktinformation C79000 Z8964 C038 05 Product Information Information produit Informazioni sul prodotto Informaci n sobre producto Stand Dated Edition Versione Versi n 06 99 CP 343 1 6GK7 343 1BA00 0XE0 ab Ausgabestand 7 FW Stand V5 00 version 7 or higher firmware V5 00 a partir de la version 7 microprogramme V5 00 a partire dalla versione 7 versione FW V4 00 a partir de la version 7 FW V5 00 SIMATIC S7 300 Deutsch English Francais Italiano Espa ol O SIEMENS AG 1998 Anderungen vorbehalten Subject to alteration Sous r serve de modifications Con riserva di modifiche Sujeto a cambios Hinweis Note Avertissement Avvertenza Indicaci n Achtung Vor der Inbetriebnahme Hinweise in der entsprechenden aktuellen Dokumentation beachten Die Bestelldaten hierf r entnehmen Sie bitte den Katalogen oder wenden Sie sich an Ihre rtliche SIEMENS Niederlassung Die Inbetriebnahme ist solange untersagt bis festgestellt wurde da die Maschine in die diese Komponente eingebaut werden soll den Bestimmungen der Richtlinie 89 392 EWG entspricht Attention Priorto startup you must observe the notes in the relevant documentation For ordering data ofthe documenta tion please refer to catologs or contact your local SIEMENS representative Startup must not take place until it is established that the machine which is to accommodate this component is in conformity the gu
7. U at the same time Extended Functions Compared with Version 5 e Reading and writing data in the FETCH WRITE mode The services FETCH and WRITE are supported for direct access to sy stem memory areas on the SIMATIC S7 PLC via ISO transport and and ISO on TCP connections The SIMATIC S7 300 with the CP 343 1 is always the server passive connection establishment while the fetch or write access client functionality with active connection establishment originates from a SIMATIC S5 PLC or other device Requirements General Operation The following table shows the S7 300 CPUs with which the CP 343 1 can be operated with this range of functions Table 2 CPU MLFB Number CPU 312 IFM 6ES7 312 5AC02 0ABO CPU 312 T 6ES7 312 5AC82 0ABO CPU 313 6ES7 313 1AD03 0ABO CPU 314 6ES7 314 1AE04 0ABO CPU 314 T 6ES7 314 1AE84 0ABO CPU 314 IFM 6ES7 314 5AE03 0ABO CPU 314 IFM T 6ES7 314 5AE83 0ABO CPU 315 6ES7 315 1AF03 0ABO CPU 315 2 DP 6ES7 315 2AF03 0ABO CPU 315 2 DP T 6ES7 315 2AF83 0ABO CPU 316 2 DP 6ES7 316 2AG00 0ABO CPU 318 2 6ES7 318 2AJ00 0ABO Product information CP 343 1 C79000 Z8964 C038 05 english Table 2 CPU MLFB Number CPU 614 6ES7 614 1AH03 0AB3 CPU 614 Z 6ES7 614 1 AHO3 0AB3 Z The table lists the CPUs approved at the time of printing this product informa tion bulletin S7 300 CPUs approved later and not listed
8. an connect the programming device when configuring the CP as follows e via MPI e via Industrial Ethernet If you configure the module via Industrial Ethernet the CP 343 1 must already have a MAC address in other words the hardware configura tion of the CP 343 1 must already have been downloaded via the MPI interface for details of node initialization see 8 12 Product information CP 343 1 C79000 Z8964 C038 05 english 2 3 Attaching the CP 343 1 to Industrial Ethernet The CP 343 1 can be attached to Industrial Ethernet using a e Transceiver with an AUI interface CP 343 1 Transceiver cable drop cable 727 1 Transceiver Figure3 Attaching the CP 343 1 to Industrial Ethernet with AUI Transceiver The CP 343 1 generates and supplies the 13 V power required by the transceiver e Industrial Twisted Pair attachment for example using a Optical Switch Module OSM or hub When using the Industrial Ethernet installation cable shown in Figure 4 the CP 343 1 automatically switches over to Twisted Pair Information about the pinout can be found at the end of this section With Industrial Twisted Pair cables with a length of up 100 m can be installed between the CP and Optical Switch Module OSM Product information CP 343 1 13 C79000 Z8964 C038 05 english CP 343 1 CP 343 1 e g Optical Switch Modul OS
9. ation and operation and contains detailed information ITI For installing and starting up the CP 343 1 Manual S7 300 Programmable Controller Hardware and Installation 18 For using and configuring the CP 343 1 Manual SIMATIC NET NCM for S7 Industrial Ethernet 19 SIMATIC NET Manual Triaxial Networks for Industrial Ethernet 10 Ethernet Manual HIR 11 User s Guide to STEP 7 Part of the basic STEP 7 package 12 SIMATIC NET Manual ITP Networks for Industrial Ethernet Order Numbers The order numbers for the SIEMENS documentation listed above can be found in the catalogs SIMATIC NET Industrial Communication Catalog IK 10 and SIMATIC Programmable Logic Controllers SIMATIC S7 M7 C7 These catalogs and additional information about the products and training courses can be obtained from your local SIEMENS office E 18 Product information CP 343 1 C79000 Z8964 C038 05 C79000 Z8974 C43 01 From Mail FAX Reply Call 911 978 3321 Namea aia aiii POSTOR calas SEATER To COMPANY vpne ate titi Siemens AG Infoservice Address ni ita ic A8D Z 032 Postfach 2348 TOD A a D 90713 F rth Postcode cin Germany Country arras dd Dear customer You can order a sticker to mark the actual version level of your CP s with this letter or by fax O Please send me the sticker Our Industrial Ethernet application oooooononnicnnnnnnnnnnnocococcconccononnnnononccnnnnnnnnnnn conc nnnnnnnnn
10. et Number of ISO transport connections Number of connections for S7 communication The actual value depends on the CPU type Explanation Values 32 maximum being used Please refer to 1 for the values for your CPU 16 maximum Maximum data length for AG_SEND and AG_RECV blocks AG_SEND and AG_RECV allow the transfer of data fields of between 1 and 240 bytes Maximum data length for AG_LSEND and AG_LRECV blocks AG_LSEND and AG_LRECV are shipped for the CP 343 1 from version 5 or higher firmware V3 00 and permit the transfer of data fields of between 1 and 8192 bytes for more detailed information see Table 3 Reaction Times of ISO Transport Connections The calculation of the reaction times with ISO transport connections is deter mined by the run time of the function blocks required on the S7 300 CPU AG SEND AG RECV Product information CP 343 1 C79000 Z8964 C038 05 english Table 5 Component Explanation Values Run time in the CPU 314 1 per block AG SEND AG LSEND AG RECV AG LRECV 2 5 ms to 5 ms 1 3 Displays and Mode Selector LED Displays The LED panel on the font of the CP 343 1 has three display elements RUN STOP Figure2 LED Displays CP Operating Mode The LEDs indicate the current operating mode of the CP 343 1 as follows STOP LED RUN LED SF LED CP operating mode yellow green red da start u e O i RUN 00
11. ideline 89 392 EEC Attention Avant la mise en service respecter les instructions de la documentation actuelle correspondante Pour les r f rences de commande de la documentation veuillez vous reporter aux catalogues ou consulter votre agence locale SIEMENS La mise en service est interdite tant que la machine dans laquelle est incorpor ce composant n est pas con forme aux prescriptions de la directive 89 392 CEE Attenzione Prima della messa in funzione osservare attentamente le avvertenze riportate nella documentazione corrente Per i dati di ordinazione consultare i cataloghi oppure rivolgersi alla locale fidale SIEMENS La messa in funzione vietata fino a quando non stato acctertato che macchina in cui il componente deve essere installato non rispetta le disposizioni della direttiva 89 392 CCE Atenci n Antes de la puesta en marcha observar las indicaciones contenidas en la documentatci n actual correspon diente La referencia de la misma puede consultarse en los cat loges o solicitarse a su agencia SIEMENSIocal Est prohibida la puesta en marcha hasta comprobar que la m quina en donde va aincorporarse este compo nente cumple lo especificado en la directiva 89 392 CCE english Contents Notes for the Reader oooooooocnnnn e eee eeeeees 1 The CP 343 1 Communications Processor 1 1 Characteristics ci ir ir oye a cee 1 2 Performance Data o ooococononononrnr eens
12. in the table also support the range of functions described here All versions of the SINUMERIK CPUs 840D and 810D are supported Requirements ISO Transport Connections The following conditions must be taken into account on ISO transport con nections depending on the length of the data to be transferred Table 3 Functionality Transfer of data fields lt 240 bytes Requirement The blocks AG_SEND FC5 and AG_RECV FC6 or as an alternative the blocks AG_LSEND FC50 and AG_ LRECV FC60 are required Transfer of data fields gt 240 bytes Note the two requirments below e You require the blocks AG_LSEND FC50 and AG_LRECV FC6O0 These blocks are shipped with NCM V 4 02 with service pack 1 The blocks are shipped as standard components of newer versions of NCM e Configuration When configuring the CP 343 1 with Hardware Configuration in STEP 7 select the option Data length gt 240 bytes under the Options tab Product information CP 343 1 C79000 78964 C038 05 english 1 2 Performance Data 1 2 1 Characteristics of S7 Communication The functions and characteristics of S7 communication are described in 8 and 11 1 2 2 Characteristics of ISO Transport Connections The following information is important for operating ISO transport connections SEND RECEIVE interface Table 4 Characteristic Total number of connections on Industrial Ethernet on Industrial Ethern
13. is possible that all the connections on the communications bus are aborted This has the following effects on the communication connections on Industrial Ethernet e All S7 connections are temporarily aborted e The ISO Transport connections on which a job with a data length gt 240 bytes is being processed are aborted The return values must be handled accordingly on the FC interface in the user program 2 Installation 2 1 Module Accessories The accessories required to attach the CP 348 1 to an Industrial Ethernet LAN must be ordered separately For more detailed information see 9 10 12 Product information CP 343 1 11 C79000 Z8964 C038 05 english 2 2 Procedure Steps in Installation Installing the CP 343 1 involves the following steps e Plug in the CP 343 1 and secure it with the screws make sure that the bus connector between the CPU IM and CP 343 1 is present e Attach the CP 343 1 to Industrial Ethernet as illustrated in Section 2 3 e Connect a 24 V power supply Note Make sure that you use the same voltage source as for the CPU or IM 361 Note The two front panels must be kept closed during operation The module must be installed so that its upper and lower ventilation slits are not covered allowing adequate ventilation Configuration To initialize the CP 343 1 for communication services use the configuration tool NCM S7 for Industrial Ethernet PG PC Connection You c
14. nn nn EEES EESE EEEE Enere E EEEE Type of application How many CP 343 1 modules are No of CP 443 1 ou using No of S5 CPs 0 Which and how many O SIMATIC S7 communication partners are you U PC with SOFTNET using in your system S7 Functions O SIMATIC S7 O PC with SOFTNET Number of connections Average data length in bytes per connection Type of cabling O Electrical with O Optical with star Triax Yellow couplers Note Your information will be used to improve our products and will of course be handled confidentially Suggestions for improvement are welcome on e mail address simatic net nbgm siemens de Please include for identification CP 343 1
15. oading Firmware The CP 343 1 supports firmware updates using the Firmware Loader An update of the firmware can be downloaded from the PC programming de vice at any time After downloading the firmware the CPU must be reconfigu red power off on or memory reset For more information on downloading the firmware refer to the README file of the NCM S7 for Industrial Ethernet configuration software Note Read the information on downloading a database to the CP in the NCM S7 manual 8 Group status 8183 on the FC call interface The return values DONE 0 ERROR 1 Status 8183 can be caused by the following states e The CP is in the STOP mode e The connection is not configured e The connection is not established 10 Product information CP 343 1 C79000 Z8964 C038 05 english Status on the FC call interface special situation with FC versions With the FCs AG_SEND FC 5 and AG_RECV FC 6 you receive the follo wing return values after a connection is aborted e AG_SEND DONE 1 ERROR 0 Status 0000y e AG_RECV DONE 0 ERROR 1 Status 8183y The new FCs for longer data fields FC AG_LSEND and AG_LRECV react in exactly the same way to a connection abort in other words with the return values e DONE 0 ERROR 1 Status 8183 Influence of MPI Connections on Connections via Industrial Ethernet If a station on MPI is added or removed for example because a service PG has been connected or disconnected it
16. ons e Mechanical and climatic ambient conditions e Insulation tests class of protection and degree of protection Product information CP 343 1 C79000 Z8964 C038 05 15 english 3 2 Pinout Connector for Industrial Ethernet On the front panel of the CP 343 1 there is a 15 pin sub D female connector with a sliding locking mechanism for connecting a transceiver cable The signals of an ITP interface can also be applied to this connector switchover by relay For operation via the AUI interface use the 727 1 transceiver cable A special SIMATIC NET ITP cable must be used when operating via the ITP interface CP 343 1 Figure6 Connector Pinout Diagram Notes on the Pinout Pin No Signal name MEXT CLSN TRMT TPETXD Ground RCV TPERXD M15V TPE_SEL Ground CLSN_N TRMT_N TPETXD_N Ground RCV_N TPERXD_N P15V Ground Function External ground shield Collision Transmit TPE transmit data Ground 5V Receive TPE Receive data Ground 15 V AUI ITP switchover Ground 5 V Collision Transmit TPE Transmit data Ground 5V Receive TPE Receive data 15 V Ground 5V The pinout complies with the IEEE 802 3 AUI interface The signals TPETXD TPETXD_N and TPERXD TPERXD_N implement the ITP interface 16 Product information CP 343 1 C79000 Z8964 C038 05 english 3 3 Notes on the CE Appro
17. ot be precluded entirely we cannot guarantee full agreement However the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions Suggestions for improvementare welcomed Technical data subject to change Industrial Automation Systems Postfach 4848 D 90327 N rnberg Product information CP 343 1 C79000 Z8964 C038 05 english 1 The CP 343 1 Communications Processor Application The CP 343 1 communications processor is designed for operation in an S7 300 programmable logic controller It allows the S7 300 to be attached to Industrial Ethernet LED displays Mode selector AUI ITP interface 15 pin sub D with sliding locking mechanism Figure1 CP 343 1 Design The module has been designed to match the components of the S7 300 programmable logic controller and has the following features e Double width module for simple installation in the S7 300 rack e The operator controls and displays are all located on the front panel e No fan necessary e Direct backplane bus connection of the modules via accompanying backplane module connectors e 15 pin sub D female connector with sliding locking mechanism for attaching the CP 343 1 to Industrial Ethernet automatic switchover between the AUI interface and Twisted Pair interface Product information CP 343 1 3 C79000 Z8964 C038 05 english Configuration You can configure the CP 343 1 via MPI or LAN
18. val of SIMATIC NET Products Product name CP 343 1 Order number 6GK7 343 1BA00 OXEO EU Directive EMC89 336 EEC The SIMATIC NET products listed above meet the requirements of the EU directive 89 336 EEC Electromagnetic Compatibility ding to the EU directives and are kept at the following address Siemens Aktiengesellschaft Bereich A amp D Industrielle Kommunikation SIMATIC NET A amp D PT 2 Postfach 4848 D 90327 N rnberg Germany CE The EU conformity certificates are available for the relevant authorities accor Area of Application The product is designed for use in an industrial environment Requirements Area of application Noise emission Noise immunity Industrial EN 50081 2 1993 EN 50082 2 1995 Directive on Machines The product remains a component in compliance with Article 4 2 of the EU directive on machines 89 392 EEC According to the directive on machines we are obliged to point out that this product is intended solely for installation in a machine Before the final pro duct is started up it must be established that it conforms to the directive 89 392EEC Installation Guidelines The product meets the requirements providing you adhere to the guidelines for installation and operation in the following documentation 7 9 and 12 Product information CP 343 1 17 C79000 Z8964 C038 05 english 4 References The following documentation is necessary for configur

Download Pdf Manuals

image

Related Search

Related Contents

M.T AA 7002 B (TRIGON).CDR  SAIZEN - Merck  Hikvision DS-7300HFI User Manual  TDSHーBA 東芝カラーロロロテレビカメラ取扱説明書 対象機種 TXD-7300  guide technique sur les nuisibles de la banane plantain, le maïs, le  Viewsonic LED LCD VA2746-LED  Pan/Tilt Head with Multiple Protocol Interface VPT-501, VPT  SmartLog V5™  CODING1-Beschreibung (User Manual)  Revell 24923  