Home

Rolls RPB486 User's Manual

image

Contents

1. SW3 67 oo SW SPST AC PLUG MCI 407 4024 c6 1N4001 ae ROLLS CORPORATION 5968 South 350 West Murray UT 84107 D3 Lt lt RPB486 B623 ZB12V ize Document Number ev Size h RPB623 SCH Aa Sheetof 19
2. LIMITED WARRANTY This product is warranted to the original consumer purchaser to be free from defects in materials and workmanship under normal installation use and service for a period of one 1 year from the date of purchase as shown on the purchaser s receipt The obligation of Rolls Corporation under this warranty shall be limited to repair or replacement at our option during the warranty period of any part which proves defective in material or workmanship under normal installation use and service provided the product is returned to Rolls Corporation TRANSPORTATION CHARGES PRE PAID Products returned to us or to an authorized Service Center must be accompanied by a copy of the purchase receipt In the absence of such purchase receipt the warranty period shall be one 1 year from the date of manufacture This warranty shall be invalid if the product is damaged as a result of deface ment misuse abuse neglect accident destruction or alteration of the serial number improper electrical voltages or currents repair alteration or maintenance by any person or party other than our own service facility or an authorized Service Center or any use violative of instructions furnished by us This one year warranty is in lieu of all expressed warranties obligations or li abilities ANY IMPLIED WARRANTIES OBLIGATIONS OR LIABILITIES IN CLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPO
3. SE SHALL BE LIMITED IN DURATION TO THE ONE YEAR DURATION OF THIS WRITTEN LIMITED WAR RANTY Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you IN NO EVENT SHALL WE BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WAR RANTY EXPRESSED OR IMPLIED WHATSOEVER Some states do not allow the exclusion or limitation of special incidental or consequential damages so the above limi tation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state RPB486 Phantom Hex ROLLS ROLLS CORPORATION SALT LAKE CITY UTAH 6 0 6 75889 00486 1 RPB486 PHANTOM HEX 6 CHANNEL PHANTOM POWER SUPPLY p p ou x a p H OUTPUT INPUT 120 VAC 5060 Hz 15 VA E I pretender wy pelle mahda lay OWNERS MANUAL INTRODUCTION Thank you for your purchase of the ROLLS RPB486 PHANTOM HEX 6 channel phantom power supply This unit powers up to 6 condenser microphones with 48 volts of ultra clean phantom power The outputs are 1 4 Tip Ring Sleeve bal anced for easy connection to a digital multi track recorder To eliminate the possibility of any DC voltages the RPB486 features pull down resistors and isolation capacitors on all outputs DESCRIPTION FRONT PANEL The green LED for each channel lights when that channel is in
4. e as the impedance of your microphone Important notice The RPB486 should be powered up and connected to the microphones before power is applied to the power amplifiers or recording device A noticeable thump sound will be heard if power amps are on before the RPB486 is powered up SCHEMATIC J2 PHONE 1 4 J2C PHONE 1 4 N XLR JACK EN cC1c 7UF0 L C2C 47UF R5C tile ae 68K E 48V0 J2D PHONE 1 4 ee 6 8K ok 48V0 aE zk R3 J N XLR JACK ED CiA47UFL LS O 30 O 47UF R5A0 C3A 47UFE Ww zzK o Zn R7 D11 100 EDE J2B0 a R1 D8 PHONE 1 4 100 Ler C1Bi47UFU i J2E PHONE 1 4 A C2E RSE ihe 100K 4 LDL N XLR JACK ED BO
5. use All these LEDs light momentarily when the RPB486 is powered up The red PWR led indicates the unit is on REAR PANEL 120 VAC MADE INUS A 50 60 Hz 15 VA Ge Ny re ik of electric shock or fira do nat expose this device to rain or moisi CAUTION To reduce the risk of electric do not remove lid No user serviceable parte inside 120 VAC 50 60 HZ 15 VA Power Cord Connect to a properly grounded AC source NOTE THE FOLLOWING DESCRIPTION APPLIES TO EACH OF THE SIX CHANNELS INPUT Female balanced XLR jack for connection to the condenser microphone Pin 2 is hot This jack carries the 48 volts of phantom power to the microphone OUTPUT 1 4 Tip Ring Sleeve balanced jack for connection to a mixer or multi track recorder Note If you are connecting this to a mixer adjust the mixer s gain or trim control carefully for a suitable input level SPECIFICATIONS Connectors 6 ea XLR female jacks pin 2 hot 6 ea 1 4 TRS jacks tip positive Phantom Power Voltage 48 Volts Max Phantom Power Current 14 mA each channel Power Supply Linear 120VAC 50 60Hz Size W x H x D 19 x 1 75 x 2 5 48 x 4 5 x 12 7 Weight 4 lbs INSTALLATION Mount the RPB486 in a sturdy rack Connect microphones to properly shielded balanced cable and connect the cable to the Input channels of the RPB486 Connect the outputs of the RPB486 to the recording or mixing device The output impedance of the RPB486 will be the sam