Home
Perlick US10KP User's Manual
Contents
1. 1 2 CAPACITOR FAN CONDENSER RELAY a gw W ke Di O T q sec a T 7 __ R COMPRESSOR TERMINALS o gt L BLUE DEI GREEN BLACK WHITE ph SWITCH Zz DI D a 10 WHITE WHITE ELECTRONIC i THERMOSTAT 4 MIN ON DELAY EVAPORATOR FAN MOTORS ALTERNATE BLACK THERMOSTAT BROWN STANDARD Berlick Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Form No Z2026 Rev 01 28 09 10 Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Form No Z2026 11 Rev 01 28 09 8300 West Good Hope Road e Milwaukee WI 53223 e Phone 414 353 7060 e Fax 414 353 7069 Toll Free 800 558 5592 e E Mail Perlick Perlick com e www Perlick com Form No 22026 Rev 01 28 09
2. SEL eg KEEP GASKETS OUT OF GROOVE iii SEAL COOLER TO FLOOR LS AFTER UNIT IS LEVEL AND ASSEMBLED FLOOR PANEL CEE FLOOR SE Ferlick EE Ges Se Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Form No Z2026 Rev 01 28 09 4 Four Keg Cooler Four Keg Cooler Assembly Assemble panels as follows Section re Floor Section 2 Left Wall Section 3 Left Back Wall Section A Right Back Wall PUSS Seas Sa SS Se BSS Ss ae PANEL NO S Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice FRONT VIEW Section Ole iavescetanie Front with Door Section REN Right Wall Section Ze Ceiling FLOOR III III III Form No Z2026 Rev 01 28 09 Ten Keg Cooler Ten Keg Cooler Assembly Assemble panels as follows Section 1 amp 2 Floor Section Section 3 Left Wall Section 4 wissen Left Back Wall Section E Right Back Wall Section 28 Right Wall Section Eege Right Front Wall PANEL Se g se COOLER i G
3. Description Part Number Description Part Number Switch 57878 Evaporator Fan Guard 57875 Light Bulb C31358 Plug Button 57882 Bulb Guard C25969 1 Door Sill 57883 Thermometer 57879 Door Closure 57884 Hinged Door Assy 57880 Light Indicator 57858 Gasket Door Assy 57881 Hinge 57885 Evaporator Fan Motor 57873 Handle 57886 Evaporator Fan Blade 57874 Door Wiper Gasket 57908 Form No Z2026 Rev 01 28 09 Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Wiring Diagram Four Keg Self Contained Cooler ELECTRONIC THERMOSTAT 4 MIN ON DELAY ALTERNATE THERMOSTAT STANDARD Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice CAPACITOR COMPRESSOR TERMINALS GREEN BROWN u OO WHITE Free O OVERLOAD FAN omg GREEN i BLACK WHITE SWITCH LIGHT eS I a z Sch Ko Lu LI 8 Et a TIN bo o 9 WHITE BLACK 4 WHITE BLACK BROWN WHITE EVAPORATOR FAN MOTORS BLACK BROWN Form No 22026 Rev 01 28 09 Wiring Diagram Ten Keg Self Contained Cooler
4. on below Insert the cam lock wrench into the lock before the panels are pushed together Turn the handle Cam Hole counterclockwise as far as it will go to fully cock the cam Note The cam must be fully cocked to assure proper locking The panels should then be pushed together tightly and locked by turning the wrench clockwise Plugs are provided to insert in cam lock holes after final assembly CAM i a CAM HOLE Form No 22026 Rev 01 28 09 General Information Preparing the Floor Assembly Snap a chalk line on the building floor to establish 1 Place do not slide all sections into position cooler location Place floor panel s on the floor and 2 Each panel is numbered on the edge For a four check for level A level floor is essential to ensure keg cooler follow the assembly order on page that vertical panels will be plumb If shimming 5 For a ten keg cooler the assembly order is required to level the sections the shims must appears on page 6 extend under the entire section not just the edges Note If ceiling height in building is restricted Shims should be used at each end at all wall panel s can be carried through the door open seams and at each floor seam They should not be ing and placed into position from inside the spaced further than 24 inches apart cooler 3 Install cap plugs in all cam lock holes 4 Seal cooler to the floor CEILING
5. E FRONT VIEW Cd Form No Z2026 Rev 01 28 09 Section eegener Door Section Section 8 4 Left Front Panel Section OF n Celing Panel with Evaporator Housiing Section 10 eeng Celing Panel GE EE Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice General Information Electrical Requirements The package unit must be installed so that the wir ing conforms to and is in accordance with National and Local Electrical Codes See Condensing Unit Data Plate for Electrical Specifications CAUTION Do not attempt to operate the condens ing unit on any other power source than that listed on the unit data plate See appropriate wiring dia gram on pages 9 10 or 11 Starting The Cooler Allow the empty utility cooler to operate 24 hours for a settling out period before use Temperature Control The temperature control is located on the evapo rator housing It is factory adjusted to maintain a temperature of approximately 34 F cut out and 40 F cut in Cut out temperatures lower than 34 F are not advisable as excessive frost may accumu late on the evaporator If excessive frost does accumulate the unit is operating at too cold a temperature To defrost the evaporator turn off the electrical power to the c
6. INSTALLATION AND OPERATION INSTRUCTIONS UTILITY COOLERS IMPORTANT INFORMATION This manual has been prepared to assist you in the installation of your Utility Cooler and to acquaint you with its operation and maintenance We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction If service is required your dealer can provide you with a list of qualified service agents For your own protection never return merchandise for credit without our approval We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction IMPORTANT WARRANTY INFORMATION To register your product visit our web site at www perlick com Click on Commercial then Service You will see the link to Warranty Registration Form You must complete and submit this form or the installation date will revert back to the ship Date MODEL NOS US4KP US10KP Table of Contents Cabinet Specifications ccccccecsssseeeeeeeeeeeees 2 Preparing for Assembly Tools REQUIFEd AA 3 Pre ASSOMDI AA 3 Placing the Utility Cooler aneen 3 Cam Lock Fastening Method 3 Assembling the Cooler Preparing the EE 4 Assembly cernere a a NEE ar 4 Assembly Order Four Keg Cooler 5 Assembly Order Ten Keg Cooler A 6 General Information Electrical Heouirements 7 Starting the Cooler cccccessessseeeceeeeeeeeeeeeeees 7 T
7. emperature Control c cecseeseseneeeneeenseeneeeees 7 Ventilation Requirements essseseeesseereeee 7 Cleaning the Condensing Unit 7 Warranty Information ccccccccceccceecceeeeeeeeeeeeees 7 Replacement Parts 22 sseeeeeeeeeeeeeeeeeeeeees 8 Wiring Diagrams Four Keg Self contained 9 Ten Keg Self contained AANEREN 10 F li k 8300 West Good Hope Road e Milwaukee WI 53223 e Phone 414 353 7060 e Fax 414 353 7069 erliic Toll Free 800 558 5592 e E Mail Perlick Perlick com e www Perlick com Form No Z2026 Rev 01 28 09 Installation and Operating Instructions Sizes and Specifications Utility Coolers Self Contained Um MODEL NOS US4KP US10KP KEG CAPACITY 4 10 DIMENSIONS Length 47 1194 93 2362 EXTERIOR Depth 47 1194 47 1194 mm Height 77 1956 79 2007 CONDENSING UNIT 1 3 Ju FULL LOAD AMPS 8 5 10 2 MAX FUSE 15 15 SHIPPING WEIGHT Ibs kg 700 318 1150 522 EXTERIOR Floor Stucco galvanized steel Roof Walls amp Doors Stucco galvanized steel painted grey INTERIOR Floor 16 gauge slip resistant stainless steel
8. ifications without prior notice Form No Z2026 Rev 01 28 09 2 Preparing the Cabinet for Use Tools Required The Cam Lock Fastening Method Tape Measure Chalk Line Caulking Gun Caulk provided Clam Lock Wrench provided Level Screw Driver Shims Pre Assembly Some panels have been protected with a strip pable film to prevent surface damage Remove this film before assembly It is very difficult to remove it from the panel edges after panels have been joined together Note Do not store panels with protective film in sunlight or high temperature areas for an extended period of time Placing the Utility Cooler This utility cooler should not be installed tight against any building or adjacent cooler wall A minimum of two inches must be provided for air circulation Shims for leveling the floor must also be incorporated into overall height and clearance requirements Remote Units A minimum four inch clearance is required between the top of the utility cooler and the ceiling of the building in which it is being installed Self contained Units Sufficient clearance above the cooler must be allowed for ceiling panel and condensing unit installation For ventilation requirements see page 7 Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice This utility cooler utilizes the cam lock fastening method See illustration
9. l Roof Walls amp Doors 26 gauge stucco galvanized steel ELECTRICAL 115 V 60 Hz 1ph AC Junction box provided PLUMBING Evaporator condensate drains through access hole in wall 20 x 1 2 LD drain line provided REFRIGERATION R134a refrigerant INSULATION 4 UL Class 1 urethane foam Flame Spreading Rate 25 or less Smoke Develop Rating 450 or less DOORS Flush mounted with cam lift chrome hinges automatic door closer magnetic gaskets chrome pull handle Standard right hinged Door size 30 W x 55 H FEATURES Light ON indicator in door Light switch and fixture installed on evaporator Thermometer furnished loose OPTIONAL ACCESSORIES e Foor rack Keg shelf kit a 23 12 Har je JUNCTION T 85 INSIDE S Geseit ZZ GE E Ee EE l i H E i Wee i 2312 ag A Ji e ranell REFRIGERATION let INSIDE REFRIGERATION i SLEEVE Hi SLEEVE j TTi 14 E fee eS TS se L 4 A T TO H 14 VIEW l e j 28 i2 INSIDE JUNCTION 44 DOOR 21 BOX z OPENING ee 93 2 j DOOR gt j 9 1 2 gt 9 30 gt 8 j LIGHT BULB OPENING W GUARD 47 LIGHT BULB 94 4 274 L4 L 32 3 4 W GUARD t 4 12 i l y i e E THERMOSTAT j EZ TET y i ye r ES ye aoa 17 eg i REF 79 eil EA er Be ae 51 1 4 Front 51 1 4 SEN i VIEW vee VIEW l i Sit i 4 KEG COOLER a 10 KEG COOLER Perlick is committed to continuous improvement Therefore we reserve the right to change spec
10. on densing unit or turn the control to a warmer posi tion to allow the fan motor to defrost it The control should then be reset to a temperature that will not ice up the evaporator A plastic drain hose should be attached to the drain pan of the evaporator and routed through the wall panel A receptacle should be provided for accumulated condensing water or connect to a building drain facility Ventilation Requirements Air cooled units must be furnished with sufficent ventilation to maintain their efficiency The table at right indicates the minimum room size cubic footage only the space above the condensing unit can be used When the room size is below minimum some type of forced ventilation must be provided Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice There should be nothing on or around the machin ery compartment area which will restrict the flow of room temperature air to the condenser or over the compressor Forced Air Circulation C F M Ft Room Volume Fresh Air Entering Needed Room Cleaning the Condensing Unit Natural Circulation Cu Compressor H P Inspect the machinery compartment every 60 days A heavy accumulation of dirt and or grease on the front of the condensing unit radiator must be cleaned off with a stiff brush or vacuum cleaner Be careful not to bend the aluminum fins on the con densing unit Warran
11. ty This Utility Cooler is fully warranted against defects in both material and workmanship for a period of one 1 year from date of sale Defective parts must be returned to Perlick freight prepaid All parts found to be defective upon inspection will be replaced on a no charge basis F O B our factory Perlick is not responsible for parts damaged by alteration unauthorized service accident or abuse All costs incident to replacement including labor refrigerant and or loss of sales are incidental to this warranty and must be borne by the user Form No 22026 Rev 01 28 09 Replacement Parts How to Order Replacement Parts Contact your local Perlick dealer to order replacement parts Be prepared to provide the model and serial num ber of the cooler The serial number is printed on a label which is attached to the inside wall adjacent to the evaporator housing SELF CONTAINED UTILITY COOLERS FOUR KEG TEN KEG Description Part Number Description Part Number Compressor Only 57499 Compressor Only 57860 Condensing Unit Fan Motor 57513 Condensing Unit Fan Motor C15250A2 Condensing Unit Fan Blade C3150 3 Condensing Unit Fan Blade C15250A3 Evaporator Coil Assembly 57861 Evaporator Coil Assembly 57872 E xpansion Valve 57877 E xpansion Valve 57877 Temp Control two wired 57891 Temp Control two wired 57891 ALL MODEL UTILITY COOLERS
Download Pdf Manuals
Related Search
Related Contents
Protect PV.500-UL - AEG Power Solutions Ci-après dénommé « CLIENT UNUSUAL 55Y Manual de usuario 取扱説明書 CATALOGUE JWELL 2015 FR.indd LIGA DE ESPORTES ESCOLARES Kenwood ESP100 series Coffeemaker User Manual Copyright © All rights reserved.
Failed to retrieve file