Paradyne IP DSLAM BitStorm 2600 User's Manual
Contents
1. Eo E ES ae Ae ii UI ue e me Ez 1 1 PRENNE PARADYNE E uu iii 020 20 0 0 0 0 0 0 0 0 0 FEE BiTSTSAM 200 O 03 17455 Figure A 1 BitStorm 2600 IP Front Panel 2600 A2 GN20 40 March 2005 A 1 A Connectors and Pin Assignments DSL Ports and POTS Splitter Connectors A 2 The 50 pin RJ21X Telco connector labeled DSL Ports 1 24 provides the 2 wire loop interface from each DSL port to the MDF for CO applications or the in building wiring for customer premises applications The Canadian designation for this connector is CA21A The 50 pin RJ21X CA21A Telco connector labeled POTS 1 24 if installed provides the 2 wire loop interface with the internal POTS splitters Table A 1 lists the pin assignments for these interfaces Note that Pins 25 and 50 are not used Table A 1 DSL Connector Pinouts DSL Port 1 oOo NI oJ AJ AJ OJN YINI NI N a a a a a a a a a wN olol o NI aJI a AJ wy N oO ine R Connector Pins Ring Tip 1 26 2 27 3 28 4 29 5 30 6 31 7 32 8 33 9 34 10 35 11 36 12 37 13 38 14 39 15 40 16 41 17 42 18 43 19 44 20 45 21 46 22 47 23 48 24 49 March 2005 26 02 17151 2600 A2 GN20 40 A Connectors and Pin Assignments Port 1 and Port 2 10 100BaseT Connectors Port 1 and Port 2 are 8 pin unkeyed modular jacks for a 10 100Base interface
2. 1 Open your web browser Internet Explorer Version 6 or above is recommended 2 Type http and the IP address of the BitStorm 2600 into the Address field of your browser window For example Address E http 135 26 10 37 3 A login window appears Enter the default User ID admin and leave Password blank Click on OK The web interface screen appears 4 Click on the menu tab appropriate to what you would like to do Configuration To configure the system and interfaces Status To display statistics status and contents of memory System To display system information download firmware back up configurations and modify users Diagnostics To start and stop tests 4 6 March 2005 2600 A2 GN20 40 System Users 4 Configuration For security reasons it is a good idea to change the default password the first time you use the system p Procedure To change the default password for user admin 1 Click on the System menu tab then click on Users The folllowing screen appears Configuration Diagnostics System Alarms and Status Date and Time Firmware Options Restart Save and Restore Scheduled Backup Selttest Results System Information Technical Support Users User Name Privilege Level C admin admin Modify Selected User Name Log In Password Privilege Password Apply 2 In the Configured Users box select admin by clicking in the circle ne
3. Table A 2 Port 1 and Port 2 Pinouts re Signal Pin Transmitted Data 1 Pin 8 97 15449 Transmitted Data Received Data Unused Unused Received Data Unused SINI on ay AJ wy hy Unused Port 3 1000BaseT Connector Port 3 s 1000BaseT interface is an 8 pin unkeyed modular jack Table A 3 Port 3 1000BaseT Connector Signal Pin TIT Pin 1 Tip 1 1 Ring 1 Pin 8 97 15449 Tip 2 Ring 3 Tip 3 Ring 2 Tip 4 0o NIIAJ AJ wo dy Ring 4 2600 A2 GN20 40 March 2005 A 3 A Connectors and Pin Assignments Port 3 GigE SFP Connector A 4 Port 3 s GigE interface is a standard SFP socket Table A 4 Port 3 GigE Connector Signal Pin VeeT 1 TXFault 2 TXDisable 3 MOD DEF 2 Il2C DATA 4 MOD DEF 1 l2C CLK 5 MOD DEF 0 SFP PRESENT L 6 Rate Select 7 LOS 8 VeeR 9 VeeR 10 VeeR 11 RD 12 RD 13 VeeR 14 VccR 15 VccT 16 VeeT 17 TD 18 TD 19 VeeT 20 March 2005 2600 A2 GN20 40 A Connectors and Pin Assignments E1 and T1 Uplink Connectors The E1 and T1 connectors on T1 E1 MLPPP models are single RJ48C unkeyed shielded 8 pin modular jacks The shield is connected to ground via the module Table A 5 E1 Uplink Connectors Signal Direction Pin Receive Ring In 1
4. Receive Tip In 2 NC E 3 Transmit Ring Out 4 Transmit Tip Out 5 NC In 6 NC 7 NC 8 Console Port Connector The CONSOLE port connector is a DB9 socket connector that supports an EIA 232 E circuit as shown in Table A 6 Table A 6 Console Port Connector RS 232 Signal Direction Pin Data Carrier Detect Out 1 Receive Data Out 2 Send Data In 3 Data Terminal Ready In 4 Ground 5 Data Set Ready Out 6 Request to Send In 7 Clear to Send In 8 Ring Indicator 9 2600 A2 GN20 40 March 2005 A 5 A Connectors and Pin Assignments ALARM Connector The alarm relay reports major alarms through the ALARM connector A 6 Table A 7 ALARM Connections 54321 ici o0000 Signal Direction Contact Major Alarm Out 1 Common Out 2 Minor Alarm Out 3 Alarm Sense In 4 Alarm Sense In 5 ALARM 03 17453 The alarm contacts are closed during normal operation They open in response to loss of power hardware failure or other alarm conditions The maximum rated load for the alarm relays is m 30VDC 1 0 Amp m 60 VDC 0 6 Amp m 60 VAC 0 6 Amp March 2005 2600 A2 GN20 40 Equipment List All BitStorm 2600 models include the BitStorm 2600 19 and 23 inch mounting brackets and hardware and an Installation Guide Table B 1 BitStorm 2600 Model List 1 of 2 Model DSL Power Cord Number Ports DSL
5. 000 cece 1 4 m Mounting Configurations lille 1 6 m Mounting Brackets lene 1 6 m Installing the Brackets for Rack Mounting 200 1 6 m Installing the BitStorm 2600 Into a Rack 0005 1 8 m Installing the BitStorm 2600 on a Wall nana aana aaaea 1 10 m Installing the BitStorm 2600 on a Shelf or Desktop 1 12 2 Cabling m Cabling Overview llslssssese RII I In 2 1 B DSL POMS see Ph sEEDER USE RR EA NE 2 2 m GigE Uplink Port 3 lllslslelss esI 2 3 m 10 100BaseT Uplink Port 2 llle sisse 2 4 B lorETUplink cR Wee eae earn Ce E 2 5 m Chaining BitStorm 2600s 0 00 ee 2 6 m Management Port 0 0 cece tees 2 7 W Console POIL css Rb duets bea bide dew s bee meek dees 2 8 Connecting a Terminal or PC to the Console Port 2 8 Connecting a Modem to the Console Port 2 9 Alarm Interface x i uc e Sex oce P re EE EN 2 10 Ground esi etur e re ERN Lettera el totes 2 11 2600 A2 GN20 40 March 2005 Contents m Connecting to Power 00 cee 2 12 3 LEDs EED EOCatlons 2 eb etr Dx REFER E RE uS 3 1 LED Meann Serau aae RPOND ae eke RE dE RM 3 2 4 Configuration Overview oda Seg d reti Set As nb bp bred uds 4 1 Using the CLI iig seh Rd REPRE RE a eee Edge wet 4 2 Configure Management Default Gateway Address 4 2 Configure Management Inband Address 4 4 3 Configure Management Out
6. CONSOLE port 1 Configure the terminal or terminal emulation program to use the following parameters Maximum speed 9600 bps Data bits 8 Parity None Flow Control None Stop bits 1 2 Determine and procure the proper Data Terminal Equipment DTE cable type The CONSOLE port requires a DB9 plug connector The other connector depends on the serial port on your terminal or PC 3 Connect the DB9 plug connector to the CONSOLE port socket The CONSOLE port is ordinarily used only during installation so do not fasten the connector 4 Connect the other end of the cable to the serial port of your terminal or PC 2000000000000 03 17447 March 2005 2600 A2 GN20 40 2 Cabling Connecting a Modem to the Console Port p Procedure To connect a modem to the CONSOLE port 1 Determine and procure the proper DCE cable type for your modem The CONSOLE port requires a DB9 plug connector The other connector depends on the serial port on your modem but normally a DB25 plug is required The cable must be an EIA 232 E crossover null modem cable 2 Connect the DB9 plug connector to the CONSOLE port socket 3 If the modem will be permanently connected fasten the connector to the Management Module with its captive screws If the BitStorm 2600 is in a rack dress the cable to the left and attach it to the rail with a cable tie 4 Connect the other end of the cable to the serial port of your modem Serial Po
7. INFRINGEMENT Some states or other jurisdictions do not allow the exclusion of implied warranties on limitations on how long an implied warranty lasts so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from one state or jurisdiction to another 6 In no event will Paradyne be liable to Licensee for any consequential incidental punitive or special damages including any lost profits or lost savings loss of business information or business interruption or other pecuniary loss arising out of the use or inability to use the Software whether based on contract tort warranty or other legal or equitable grounds even if Paradyne has been advised of the possibility of such damages or for any claim by any third party 7 The rights granted under this Agreement may not be assigned sublicensed or otherwise transferred by the Licensee to any third party without the prior written consent of Paradyne 8 This Agreement and the license granted under this Agreement shall be terminated in the event of breach by the Licensee of any provisions of this Agreement 9 Upon such termination the Licensee shall refrain from any further use of the Software and destroy the original and all copies of the Software in the possession of Licensee together with all documentation and related materials This Agreement shall be governed by the laws of the State of Florida without regard
8. Type Splitters Compatibility Other Features 2611 A1 420 24 ReachDSL None North America 2611 A1 424 24 ReachDSL None UK B 2611 A1 425 24 ReachDSL None Europe 2611 A1 430 24 ReachDSL 900 Ohm North America 2611 A1 434 24 ReachDSL 600 Ohm UK 2611 A1 435 24 ReachDSL 600 Ohm Europe 2611 A1 436 24 ReachDSL 600 Ohm India 2614 A1 420 24 ReachDSL None North America T1 MLPPP 8 ports 2614 A1 422 24 ReachDSL None North America E1 MLPPP 8 ports 2621 A2 420 24 ADSL2 None North America 2621 A2 424 24 ADSL2 None UK 2621 A2 425 24 ADSL2 None Europe 2621 A2 430 24 ADSL2 900 Ohm North America 2621 A2 434 24 ADSL2 600 Ohm UK 2621 A2 435 24 ADSL2 600 Ohm Europe 2621 A2 436 24 ADSL2 600 Ohm India 2624 A1 420 24 ADSL2 None North America T1 MLPPP 8 ports 2624 A1 422 24 ADSL2 None North America E1 MLPPP 8 ports 2631 A2 425 24 ADSL2 None Europe Annex B 2671 A1 420 24 SHDSL None North America 2674 A1 420 24 SHDSL None North America T1 MLPPP 8 ports 2600 A2 GN20 40 March 2005 B 1 B Equipment List B 2 Table B 1 BitStorm 2600 Model List 2 of 2 Model DSL Power Cord Number Ports DSL Type Splitters Compatibility Other Features 2674 A1 422 24 SHDSL None North America E1 MLPPP 8 ports Tab
9. UTP cable Port 2 10 100BT 8 position modular plug and 8 wire Category 5 or better unshielded twisted pair UTP cable Port 1 10 100BT 8 position modular plug and 8 wire Category 5 or better unshielded twisted pair UTP cable A Network Management System NMS over a Local Area Network LAN employing 10BaseT or 100BaseT T1 E1 Ports 1 8 From one to eight 8 position modular plug and 8 wire Category 5 or better unshielded twisted pair UTP cables A BitStorm 2600 to a T1 E1 bridged PPP or MLPPP uplink interface CONSOLE DB9 plug connector and The BitStorm 2600 to one of the shielded cable following m The other connector m Aterminal or a PC with a depends on the serial port on terminal emulation program your terminal or PC but or normally is a DB9 socket m The other connector m Amodem depends on the serial port on your modem but normally is a DB25 plug A null modem crossover cable is required ALARM 5 position terminal block and The BitStorm 2600 to an alarm shielded twisted pair cable system March 2005 1 3 1 Installation Unpacking the Hardware HANDLING PRECAUTIONS FOR STATIC SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge ESD during normal operation When performing installation procedures however take proper static control precautions to prevent damage to equipment If
10. be applied to the IP address The default mask is 255 255 255 0 Example PDYN configure management out of band address bootp PDYN configure management out of band address 137 90 127 3 255 255 255 0 2600 A2 GN20 40 March 2005 4 3 4 Configuration BitStorm 2600 Startup Procedure Login You can initialize your BitStorm 2600 via a PC or terminal connected to the unit s CONSOLE port Then using a series of CLI commands GrandVIEW EMS or another Element Management System or the web interface you can configure the unit according to your requirements p gt Procedure To log in to the BitStorm 2600 1 Connect a PC or terminal to the CONSOLE port See Console Port in Chapter 2 Cabling At the login prompt type admin and press Enter At the password prompt press Enter The default login password is blank At the PDYN gt prompt type privilege and press Enter a A OO I At the password prompt press Enter The default privileged password is blank You are now logged on and in privileged mode which allows you to configure the unit Management Modes The startup procedure for the BitStorm 2600 system differs depending on the type of management used m Inband Management Operates over the uplink m Out of Band Management Operates over Port 1 March 2005 2600 A2 GN20 40 4 Configuration Startup Procedure for Inband Management With inband management the BitStorm 2600 is ma
11. so their heads are about 1 4 inch 6 mm from the wall 17 85 in 453 mm 03 17437 7 Hang the unit from the wood screws to verify that the screws are properly placed The screws should freely slide into the top of the key slots in the brackets Do not fasten the unit to the wall until after it is completely cabled and tested 2600 A2 GN20 40 March 2005 1 11 1 Installation Installing the BitStorm 2600 on a Shelf or Desktop If the BitStorm 2600 will be placed on a shelf or desktop install the provided rubber feet before putting the unit in position p Procedure To install the BitStorm 2600 on a shelf or desktop as a standalone unit or in a stack 1 Locate the rubber feet in the hardware kit provided with the unit 2 Turn the unit upside down on a work surface Squares stamped into the bottom of the unit show the proper positions for the feet 3 Remove the protective sheet from the bottom of each foot then press the foot onto a corner of the bottom of the unit 03 17439 4 Turn the unit right side up and place it in position on a shelf or desktop If the installation includes more than one unit one can be stacked atop another Up to five units can be stacked together 1 12 March 2005 2600 A2 GN20 40 Cabling Cabling Overview The BitStorm 2600 has a large variety of possible cabling configurations This chapter describes all possible connections not all of which are
12. to its provisions concerning conflicts of laws 2600 A2 GN20 40 March 2005 B A Important Safety Instructions 1 2 10 11 12 Read and follow all warning notices and instructions marked on the product or included in the manual This product is intended to be used with a 3 wire grounding type plug a plug that has a grounding pin This is a safety feature Equipment grounding is vital to ensure safe operation Do not defeat the purpose of the grounding type plug by modifying the plug or using an adapter Prior to installation use an outlet tester or a voltmeter to check the AC receptacle for the presence of earth ground If the receptacle is not properly grounded the installation must not continue until a qualified electrician has corrected the problem If a 3 wire grounding type power source is not available consult a qualified electrician to determine another method of grounding the equipment Slots and openings in the cabinet are provided for ventilation To ensure reliable operation of the product and to protect it from overheating these slots and openings must not be blocked or covered Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord Do not attempt to service this product yourself as it will void the warranty Opening or removing covers may expose you to dangerous high voltage points or other risks Refer all servicing to qualified service perso
13. use the Software solely as it is intended and solely as incorporated in the Product purchased from Paradyne or its authorized distributor or reseller under the following terms and conditions 1 Ownership The Software is the sole property of Paradyne and or its licensors The Licensee acquires no title right or interest in the Software other than the license granted under this Agreement 2 Licensee shall not use the Software in any country other than the country in which the Product was rightfully purchased except upon prior written notice to Paradyne and an agreement in writing to additional terms 3 The Licensee shall not reverse engineer decompile or disassemble the Software in whole or in part 4 The Licensee shall not copy the Software except for a single archival copy 5 Except for the Product warranty contained in the manual the Software is provided AS IS and in its present state and condition and Paradyne makes no other warranty whatsoever with respect to the Product purchased by you THIS AGREEMENT EXPRESSLY EXCLUDES ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED OR ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION a Any warranty that the Software is error free will operate uninterrupted in your operating environment or is compatible with any equipment or software configurations and b ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON
14. x 1 2 for use with self retaining 4 e nuts 02 17257 NP Machine screw with captive starwasher 10 32 x 1 2 4 w for use with racks with threaded holes 4902 17258 3S Captive pan head screw for replacing long Telco screw 2 02 17325 m Rubber foot for desk mount and stacking of units 4 02 17261 Cable tie 8 for strain relief and cable management 2 5 position plug for ALARM connection 1 March 2005 1 5 1 Installation Mounting Configurations Three basic installation configurations are available m Rack mount see nstalling the Brackets for Rack Mounting on page 1 6 and Installing the BitStorm 2600 Into a Rack on page 1 8 m Wall mount see nstalling the BitStorm 2600 on a Wall on page 1 10 m Shelf or desktop see Installing the BitStorm 2600 on a Shelf or Desktop on page 1 12 Mounting Brackets Your BitStorm 2600 can be installed in a rack or on the wall using mounting brackets Two brackets suitable for a 19 inch 483 mm rack marked EIA 19 and two brackets suitable for a 23 inch 584 mm Bay Networks or Nortel rack marked with Paradyne Part Number 868 6282 0020 are shipped with the unit Two brackets suitable for a 21 inch 535 mm rack marked ETSI are available from Paradyne as a separate feature see Appendix B Equipment List Rack mounting brackets may also be used to attach the unit to a wall NOTE In this guide the term rack refers to any rack cabinet frame or bay suitable for mounting t
15. BitStorm 2600 IP DSLAM Installation Guide Document No 2600 A2 GN20 40 March 2005 ANADIA S Copyright 2005 Paradyne Corporation All rights reserved Printed in U S A Notice This publication is protected by federal copyright law No part of this publication may be copied or distributed transmitted transcribed stored in a retrieval system or translated into any human or computer language in any form or by any means electronic mechanical magnetic manual or otherwise or disclosed to third parties without the express written permission of Paradyne Corporation 8545 126th Ave N Largo FL 33773 Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose Further Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual Warranty Sales Service and Training Information Contact your local sales representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distribut
16. C Copper cables connecting W Port 2 to Port 2 must be at least 3 feet 0 9 m long m Port 3 to Port 3 must be at least 6 feet 1 8 m long Shorter cables may cause data errors 2 6 March 2005 2600 A2 GN20 40 2 Cabling Management Port Port 1 can be used to connect the BitStorm 2600 to a network management System using a 10BaseT or 100BaseT LAN A straight through cable can be used regardless of the destination interface since the port automatically distinguishes between an MDI and an MDIX p Procedure To use Port 1 as the out of band management port 1 Connect an 8 position modular cable to Port 1 2 If the BitStorm 2600 is in a rack fasten the cable to a rail with a cable tie 3 Connect the other end of the cable to your Ethernet switch or a network interface card in a PC eg Q amp A Ethernet Switch 04 17521 2600 A2 GN20 40 March 2005 2 7 2 Cabling Console Port The CONSOLE port normally serves as the primary user interface with the BitStorm 2600 during installation You can connect a terminal or PC directly to the CONSOLE port using a DTE cable see procedure below You can also use the CONSOLE port to attach a modem to the BitStorm 2600 for remote dial in management of the unit using a DCE cable see Connecting a Modem to the Console Port on page 2 9 Connecting a Terminal or PC to the Console Port p Procedure To connect a terminal or PC to the
17. DSL CPE They support ADSL Annex A including ADSL2 and ADSL2 The 2624 models support E1 or T1 MLPPP m The ADSL Model 2631 supports ADSL Annex B including ADSL2 and ADSL24 m The SHDSL Model 2671 and 2674 are interoperable with any standard SHDSL CPE They support SHDSL G 991 2 The 2674 models support E1 or T1 MLPPP See Appendix B Equipment List for a description of all available models User interfaces include a Command Line Interface CLI and a web browser interface The unit also may be managed using a network manager such as the Paradyne GrandVIEW Element Management System EMS 2600 A2 GN20 40 March 2005 1 1 1 Installation Preparation 1 2 Up to eight BitStorm 2600 units can be logically stacked with aggregation for up to 192 ports of DSL traffic ReachDSL ADSL and SHDSL units can be included in the same stack Consider the following before installing the BitStorm 2600 IP DSLAM Installation Site Your installation site should be well ventilated clean and free of environmental extremes Installation Options The BitStorm 2600 may be Mounted with the included mounting brackets in a standard 19 inch 483 mm or 23 inch 584 mm rack including both Bay Networks and Nortel 23 inch racks or with separately purchased mounting brackets in a 21 inch B35 mm ETSI rack ETSI brackets are available from Paradyne See Appendix B Equipment List As many BitStorm 2600 units may be mounted in a standar
18. G dmt G 992 1 m G lite G 992 2 m ANSI T1 413 1998 m ADSL2 G 992 3 m ADSL2 G 992 5 Model 2631 m G dmt G 992 1 Annex B m ADSL2 G 992 3 Annex B m ADSL2 G 992 5 Annex B Model 2671 m G SHDSL G 991 2 Electromagnetic Compatibility EMC Meets the following standards m EN 300 386 2 m EN 55024 m EN 55022 Class A m FCC Part 15 Class A m VCCI Class A March 2005 C 1 C Technical Specifications Table C 1 BitStorm 2600 Technical Specifications 2 of 2 Specifications Criteria Interfaces m DSL PORTS 50 pin RJ21X Telco type connector m POTS 50 pin RJ21X Telco type connector m CONSOLE DB9 EIA 232 E m Port 1 and Port 2 8 pin modular jack 10 100BaseT m Port 3 copper interface 8 pin modular jack 1000BaseT m Port 3 fiber interface SFP socket m T1 E1 MLPPP interface eight RJ48C modular jacks Operating Environment Ambient Temperature 0 to 50 C 32 to 122 F Relative Humidity 5 to 95 noncondensing Storage Temperature 40 to 85 C 40 to 185 F Shock and vibration tolerance sufficient to withstand normal shipping Physical Dimensions Height 1 75 44 5 mm or 1U as defined in EIA 310 C without feet Width 17 2 437 mm without mounting brackets Depth 16 0 406 mm with cables Power 90 265 VAC 47 63 Hz Power Consumption Model 2611 45 Watts Maximum Model 2614 43 Watts maximum Model 2621 57 Watts Maxim
19. GigE Uplink Link LEDs Activity LEDS DSL Ports LEDs PORT 1 10 100BT e 7 1000B7 PORT3 rA Gige A p Lir r TL pu Lu c LINK c ACT I I Mi 020502020202 020 2U 4U eU sU 10U 12U 14U 16 U 18 U 20 U 22 U 24 03 17454 CONSOLE ALARM o d o o o o o o o o o c STATUS lt gt ALARM C TEST Figure3 1 Front Panel LEDs GigE Uplink Link Activity Uplink DSL Ports LEDs LEDs LEDs LEDs zn aras we 40 0 0 0 020 0 50 0202020 05 17629 STATUS Figure 3 2 Front Panel LEDs T1 E1 Uplink 2600 A2 GN20 40 March 2005 3 1 3 LEDs LED Meanings When power is first applied to the unit it performs a power on self test When this test is successfully completed the Status LED blinks The meaning of all the LEDs is shown in Table 3 1 Front Panel LEDs Table3 1 Front Panel LEDs LED Color State Meaning Link Green Off No Ethernet link present On Ethernet Link present Flashing Ethernet link is present but port is administratively disabled Activity Green Off No data is being transferred On Data is being transferred Uplink Ports 1 8 Green On Good signal unit is trained DERE THOGIS Yellow On Link is in an alarm state Off Link is disabled STATUS Green Off No power or the unit has not completed initialization On Unit has power and has complet
20. RTS 1 24 connector to the unit using the long captive pan head screw provided Anchor 50 Pin A 02 17346 Connector 2 2 March 2005 2600 A2 GN20 40 2 Cabling 4 Tighten the cable tie around the connector and trim the excess 5 If you use an internal POTS splitter repeat Step 1 through Step 4 substituting POTS 1 24 for DSL PORTS 1 24 6 Secure the cables as required for strain relief GigE Uplink Port 3 Port 3 comprises two interfaces only one of which may be used at a time An 8 position modular jack providing support for 1000BaseT A Small Form Factor Pluggable SFP socket providing with the appropriate transceiver installed support for 1000BaseX A single mode 1000BaseLX transceiver is available from Paradyne See Appendix B Equipment List Either interface can be used as the uplink for a single BitStorm 2600 or for the terminating unit in a stack of BitStorm 2600s p gt Procedure To use Port 3 as the uplink 1 Connect the uplink cable to the BitStorm 2600 2600 A2 GN20 40 For a wire connection plug the 8 position modular plug of your uplink cable into the Port 3 1000BT modular jack A straight through cable can be used regardless of the destination interface since the port automatically distinguishes between a Medium Dependent Interface MDI and an MDI Crossover MDIX For a fiber connection plug your transceiver into the Port 3 GigE SFP socket Plug the LC conn
21. Storm 2600 and GranDSLAM 4200 Training Guide Describes how to configure the BitStorm 2600 IP DSLAM for triple play video voice and data 6051 A2 GZ40 BitStorm 6051 POTS Splitter Installation Instructions Describes how to install the BitStorm 6051 POTS splitter 6210 A2 GB20 Hotwire 6210 A2 6211 A2 and 6381 A2 User s Guide Describes the installation and operation of the 6210 ADSL bridge 6211 ADSL router and 6381 ADSL R router 7890 A2 GB22 GranaVIEW EMS User s Guide Contains instructions for maintaining network services and resources using the GrandVIEW Element Management System EMS To order a paper copy of a Paradyne document or to talk to a sales representative please call 727 530 2000 March 2005 2600 A2 GN20 40 Installation Overview The BitStorm 2600 is a family of stackable IP DSLAMs designed for installation in a Central Office CO multi tenant unit MTU multi dwelling unit MDU or remote terminal environment The BitStorm 2600 is available with or without internal POTS splitters 03 17435 m The ReachDSL Models 2611 and 2614 are interoperable with the Hotwire 6381 ADSL R modem as well as with all other Customer Premises Equipment CPE containing Asymmetric Digital Subscriber Line ReachDSL ADSL R chipsets The 2614 models support E1 or T1 MLPPP m The ADSL Models 2621 and 2624 are interoperable with the Hotwire 6381 ADSL R modem as well as any standard A
22. at the network interface Use caution when installing or modifying telephone lines Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning Do not use the telephone to report a gas leak in the vicinity of the leak CLASS 1 LASER PRODUCT This product has provisions for the customer to install a Class 1 laser transciever which provides optical coupling to the telecommunication network Once a Class 1 laser product is installed the equipment is to be considered to be a Class 1 Laser Product Appareil Laser de Classe 1 The customer is responsible for selecting and installing the laser transciever and for insuring that the Class 1 AEL Allowable Emission Limit per EN IEC 60825 is not exceeded after the laser transponders have been installed Do not install laser products whose class rating is greater than 1 Refer to all important safety instructions that accompanied the transciever prior to installation Only laser Class 1 devices certified for use in the country of installation by the cognizant agency are to be utilized in this product Input power to the ALARM relay interface located on the front panel of the enclosure must not exceed 30V rms or 60 VDC The equipment is intended for installation in a max 50 C ambient temperature in an environment that is free of dust and dirt March 2005 2600 A2 GN20 40 13 The power supply cord for co
23. d rack as there are 1 75 inch 44 45 mm spaces in the rack so long as adequate cooling is provided Mounted vertically against a wall The standard mounting brackets provided can be fastened to the base of the unit for wall mounting Set on a shelf or desktop Up to five BitStorm 2600 units may be stacked on a shelf or desktop Different models can be mixed in a stack Power The BitStorm 2600 operates from a 90 to 265 VAC 47 to 63 Hz power source Other Cabling No cables are provided with the BitStorm 2600 See Table 1 1 Cable Descriptions to determine what cables you need to obtain before installation March 2005 2600 A2 GN20 40 2600 A2 GN20 40 Cables Required 1 Installation Table 1 1 shows all the cables that may be required for your installation Table 1 1 Cable Descriptions Connector Name Connector and Cable For Connecting DSL PORTS 1 24 50 pin RJ21X Telco type straight connector and 50 wire cable Two cables required one for DSL and one for POTS if Up to 24 DSL ports to Main Distribution Frame punchdown block or splitters POTS 1 24 used Up to 24 POTS splitter ports to Main Distribution Frame or punchdown block Port 3 SFP Transceiver An upstream BitStorm 2600 to a GigE downstream BitStorm 2600 or a downstream BitStorm 2600 to an Port 3 8 position modular plug and upstream BitStorm 2600 or 1000BT 8 wire Category 5 or better network unshielded twisted pair
24. e eight ports that can be used in any combination to provide PPP or MLPPP uplinks p Procedure To use T1 or E1 uplinks 1 Use the CLI or web interface to configure PPP or MLPPP paths 2 Connect an 8 position modular cable to one of the eight T1 or E1 ports on the faceplate of the DSLAM Connect the other end of the cable to the uplink interface 3 Connect up to seven other T1 or E1 cables as in Step 2 4 Fix the cable or cables to the rail as required for strain relief 05 17628 CAUTION It is possible to create bridging loops by connecting cables improperly relative to the configuration defined on the SCP card 2600 A2 GN20 40 March 2005 2 5 2 Cabling Chaining BitStorm 2600s Up to eight BitStorm 2600s can be chained together to use a single uplink The same port eth2 or eth3 used as the uplink for one unit must be used as the downlink for the next For example in this illustration W The top unit has Port 3 eth3 defined as its uplink and is connected to Port 3 of the next unit in the chain using a straight through 8 position modular cable m The middle unit has Port 2 eth2 defined as its uplink and is connected to Port 2 of the next unit m The bottom unit has Port 3 eth3 defined as its uplink which is the uplink for the stack That unit is using the fiber interface S S 9 4 fe ay I wet 9 P d DEAM D we at Sf 2 EP To e f S 9 03 17440 S
25. ector of your fiber optic uplink cable into the cable socket of the transceiver Observing the minimum bend radius for your cable fasten it with cable ties in such a way that it will not be kinked or snagged in the course of other cabling If you do not know the specifications for your cable maintain a radius of at least ten times the cable diameter March 2005 2 3 2 Cabling 03 17441 SFP Transceiver N LC Connector 2 Connect the other end of the uplink cable to the uplink interface such as an Ethernet switch 3 Port 3 eth3 is the default uplink If you have changed the default use the configure uplink CLI command or the Configuration Uplink screen of the web interface to specify eth3 as the uplink port 10 100BaseT Uplink Port 2 Port 2 can be configured as the uplink for a single BitStorm 2600 or for the terminating unit in a stack of BitStorm 2600s A straight through cable can be used regardless of the destination interface since the port automatically distinguishes between an MDI and an MDIX p Procedure To use Port 2 as the uplink 1 Connect an 8 position modular cable to Port 2 2 Connect the other end of the cable to the uplink interface such as an Ethernet Switch 3 Using the configure uplink CLI command or the Configuration Uplink screen of the web interface specify eth2 as the uplink port 2 4 March 2005 2600 A2 GN20 40 2 Cabling T1 or E1 Uplink Models that support T1 or E1 hav
26. ed initialization ALARM Amber Off No Alarms On An alarm is reported the unit failed self test or the unit has exceeded a safe temperature or a fan has failed or a port is in an alarm state TEST Amber Off Normal operating mode On At least one port is in test mode DSL Ports Green Off The port is disabled or no signal is detected on LEDs the line numbered 1 24 correspond to On ids has uM trained with the remote DSL ports 1 24 and is active The RJ45 type connectors for Port 1 Port 2 and if present Port 3 bear two LEDs the left one is the Link LED and the right one is the Activity LED The SFP socket for Port 3 has two adjacent LEDs marked LINK and ACT 3 2 March 2005 2600 A2 GN20 40 Configuration Overview The BitStorm 2600 is designed to require minimal configuration before it can be accessed by a Network Operations Center NOC When the BitStorm 2600 is first powered up it is a fully functional bridge and all DSL ports are set to their maximum speed Initial configuration is performed using the Command Line Interface CLI The CLI is available from a terminal or PC connected to the CONSOLE port Additional configuration may be necessary depending on the mode used to manage the BitStorm 2600 m Inband m Out of band through Port 1 This can be performed using the CLI SNMP or the web interface For more configuration information see the BitStorm 2600 and GranDSLAM 4200 IP DSLAM Command Line In
27. el Administrator ports Example ip address Specifies the IP address of the default gateway for the management PDYN configure management default gateway 137 90 127 1 4 2 March 2005 2600 A2 GN20 40 4 Configuration Configure Management Inband Address The configure management inband address command specifies the IP address of the unit configure management inband address ip address subnet mask Minimum Access Level Administrator ip address Specifies the management IP address Default is 0 0 0 0 disabled Do not configure inband and out of band management on the same subnet subnet mask Specifies the subnet mask to be applied to the IP address The default mask is 255 255 255 0 Example PDYN configure management inband address 137 90 127 3 255 255 255 0 Configure Management Out of Band Address The configure management out of band address command specifies the IP address of the unit that will accept management traffic on the out of band management port configure management out of band address bootp fip address subnet mask Minimum Access Level Administrator bootp Specifies that a BOOTP server will determine the management IP address ip address Specifies the management IP address The default address is 10 10 10 10 Do not configure inband and out of band management on the same subnet subnet mask Specifies the subnet mask to
28. elecommunications equipment Installing the Brackets for Rack Mounting p Procedure To install the mounting brackets for rack mounting 1 Locate the black screw nearest the front panel on each side of the unit as shown 2 Remove these two black screws one from each side before attempting to install the mounting brackets 1 6 March 2005 2600 A2 GN20 40 1 Installation 3 Identify six flat head screws for 19 inch racks or six machine screws for 23 inch racks provided with the mounting brackets in the hardware kit 4 Attach the brackets appropriate to your rack size Tighten all screws firmly 19 inch 483 mm Rack Mount 23 inch 584 mm EIA and Bay Networks Rack Mount 21 1 inch 535 mm Rack Mount 23 inch 584 mm Nortel Rack Mount 02 17324 2600 A2 GN20 40 March 2005 1 7 1 Installation Installing the BitStorm 2600 Into a Rack Two types of mounting screws are provided Use m 10 32 mounting screws for rails with threaded screw holes W 412 24 mounting screws and self retaining nuts for rails with unthreaded screw holes p Procedure To install the BitStorm 2600 into a rack 1 Determine where in the rack you will mount the BitStorm 2600 If your rack does not have threaded screw holes slip self retaining nuts onto the rails where the BitStorm 2600 will be fastened 9 5oooooocooooo t q y a SSOSEPSSCOSSSS L 02 17070 2 Place the unit so
29. in are the trademarks service marks registered trademarks or registered service marks of their respective owners A March 2005 2600 A2 GN20 40 Software and Firmware License Agreement ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS YOU MAY USE THE SOFTWARE AND OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT BY USING THE PARADYNE PRODUCT YOU SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS LICENSE AGREEMENT PROMPTLY RETURN THE UNUSED PRODUCT IN ITS ORIGINAL PACKAGING AND YOUR SALES RECEIPT OR INVOICE TO THE LOCATION WHERE YOU OBTAINED THE PARADYNE PRODUCT OR THE LOCATION FROM WHICH IT WAS SHIPPED TO YOU AS APPLICABLE AND YOU WILL RECEIVE A REFUND OR CREDIT FOR THE PARADYNE PRODUCT PURCHASED BY YOU The terms and conditions of this License Agreement the Agreement will apply to the software and or firmware individually or collectively the Software incorporated into the Paradyne product the Product purchased by you and any derivatives obtained from the Software including any copy of either If you have executed a separate written agreement covering the Software supplied to you under this purchase such separate written agreement shall govern Paradyne Corporation Paradyne grants to you and you Licensee agree to accept a personal non transferable non exclusive right without the right to sublicense to
30. le B 2 BitStorm 2600 Related Equipment List Model Number Description 2600 A2 GB21 BitStorm 2600 and GranDSLAM 4200 IP Command Line Interface Reference paper copy 2600 A2 GB22 BitStorm 2600 and GranDSLAM 4200 IP SNMP Reference paper copy 4200 F1 001 Mounting Brackets for ETSI 21 inch 535 mm Rack 4200 F3 000 Single Mode 1000BaseLX SFP Transceiver 10 km 1310 nm FP LD 4200 F3 001 Single Mode 1000BaseLX SFP Transceiver 40 km 1310 nm DFB LD 4200 F3 002 Single Mode 1000BaseZX SFP Transceiver 80 km 1550 nm DFB LD 4200 F3 003 Multimode 1000BaseSX SFP Transceiver 0 55 km 850 nm VCSEL 5011 A1 000 1 Slot POTS Splitter Chassis 5016 A1 000 6 Slot POTS Splitter Chassis 6051 B1 001 BitStorm 6051 Universal Line Sharing POTS Splitter 8400 F 1 001 LC to SC Multimode Conversion Cable 8400 F 1 002 LC to SC Single Mode Conversion Cable March 2005 2600 A2 GN20 40 Technical Specifications 2600 A2 GN20 40 Technical specifications are subject to change without notice Table C 1 BitStorm 2600 Technical Specifications 1 of 2 Specifications Criteria Alarm Contacts Maximum Rated Load m 30 VDC 1 0 Amp m 60 VDC 0 6 Amp m 60 VAC 0 6 Amp Cooling and Air Each BitStorm 2600 is independently cooled with integral fans and Handling does not rely on vertical air flow DSL Models 2611 and 2614 Compatibility m ReachDSL 22 Models 2621 and 2624 m
31. ment unless the changes or modifications are expressly approved by Paradyne Corporation If the equipment includes a ferrite choke or chokes they must be installed per the installation instructions CANADA EMI NOTICE This Class A digital apparatus meets all requirements of the Canadian interference causing equipment regulations Cet appareil num rique de la classe A respecte toutes les exigences du r glement sur le mat rial brouilleur du Canada Notices to Users of the Canadian Telephone Network NOTICE This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is confirmed by the registration number The abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment NOTICE The Ringer Equivalence Number REN for this terminal equipment is labeled on the equipment and includes the effect of the POTS splitter The REN assigned to each terminal equipment provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five When the equipment is used in a customer premises en
32. naged using the uplink port p Procedure To start up the BitStorm 2600 using inband management 1 Specify the uplink port using the configure uplink command It must be either eth2 Port 2 or eth3 Port 3 For example PDYN configure uplink eth3 2 Assign an IP address netmask and next hop router using the configure management command For example PDYN configure management inband address 137 90 127 3 255 255 255 0 PDYN configure management default gateway 137 90 127 1 Do not configure inband and out of band management on the same subnet Startup Procedure for Out of Band Management In out of band management you manage the unit through Port 1 p gt Procedure To start up the BitStorm 2600 using out of band management 1 Assign an IP address netmask and next hop router using the configure management command For example PDYN configure management out of band address 137 90 80 3 255 255 255 0 PDYN configure management default gateway 137 90 80 1 You can now access the web interface by typing into the Location field of your web browser the IP address assigned to the Port 1 See Using the Web Interface on page 4 6 Do not configure inband and out of band management on the same subnet 2 Configure routers as necessary to route data from the NOC to the BitStorm 2600 2600 A2 GN20 40 March 2005 4 5 4 Configuration Using the Web Interface To access the web interface p Procedure
33. nments A 2 port description 1 3 power C 2 connecting to 2 12 consumption C 2 requirements 2 12 C 2 PPP 2 5 preinstallation 1 2 product related documents iv purpose of this document iii R rack installation 1 8 bracket installation 1 6 example 1 9 procedure 1 8 related documents iv Return key 4 2 RJ21X connectors A 2 RJ45 pinouts A 3 S screws provided 1 5 2600 A2 GN20 40 Index SFP socket cabling 2 3 pinouts A 4 shelf installation 1 12 shipping carton 1 4 site preparation 1 2 site requirements 1 2 C 2 SNMP configuring parameters 4 8 Software and Firmware License Agreement B specifications product C 1 stacking 1 2 startup procedures 4 4 Status LED 3 2 synopsis of chapters iii T T1 uplink cabling 2 5 pin assignments A 5 technical specifications C 1 Telco connectors fastening 2 2 pinouts A 2 terminal cabling and settings 2 8 Test LED 3 2 trap managers 4 8 troubleshooting LEDs 3 1 turn up procedures 4 4 typographic conventions 4 2 U unpacking 1 4 uplink cabling 2 4 2 5 GigE cabling 2 3 Port 2 2 4 Uplink Ports LEDs 3 1 3 2 V VT100 cabling and settings 2 8 W wall mount bracket installation 1 10 screw positions 1 11 web interface password 4 7 starting 4 6 using 4 6 weight C 2 March 2005 IN 3 Index IN 4 March 2005 2600 A2 GN20 40
34. nnel General purpose cables are described for use with this product Special cables which may be required by the regulatory inspection authority for the installation site are the responsibility of the customer To reduce the risk of fire use a UL Listed or CSA Certified minimum No 26 AWG 0 128 mm telecommunication cable or comparable cables certified for use in the country of installation When installed in the final configuration the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists and if necessary implement corrective action prior to interconnecting the products In addition if the equipment is to be used with telecommunications circuits take the following precautions Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected
35. of Band Address 4 3 m BitStorm 2600 Startup Procedure 000 cee eee eee 4 4 I nnpPPME c 4 4 Management Modes 0 eee eee 4 4 m Startup Procedure for Inband Management 5 4 5 m Startup Procedure for Out of Band Management 4 5 m Using the Web Interface llle 4 6 m System Users 00 00 ccc tte 4 7 m Configuration Management SNMP 20000 eee 4 8 A Connectors and Pin Assignments M Overview eiri uei i a aa e rhe A 1 m DSL Ports and POTS Splitter Connectors s s saana aaua auan A 2 m Port 1 and Port 2 10 100BaseT Connectors 2005 A 3 m Port3 1000BaseT Connector 00060 ee A 3 m Port3 GigE SFP Connector 0000 ce eee A 4 m E1andT1 Uplink Connectors 00000 cee ee A 5 m Console Port Connector s s sussa selle ees A 5 m ALARMConnector ssslsesesesee ns A 6 B Equipment List C Technical Specifications Index ii March 2005 2600 A2 GN20 40 About This Guide Document Purpose and Intended Audience This document is written for technicians who install the BitStorm9 2600 IP DSLAM Document Summary Section Description Chapter 1 Installation Describes the physical installation of the BitStorm 2600 into a rack Chapter 2 Cabling Describes how to install all cables for the BitStorm 2600 Chapter 3 LEDs Explains the meaning and usage of the front panel LEDs Cha
36. ont panel of the BitStorm 2600 4 If the BitStorm 2600 is in a rack dress the cable to the left and secure it to the rail with a cable tie 5 Connect the other end of the cable to your alarm monitoring system March 2005 2600 A2 GN20 40 2 Cabling Ground p Procedure To connect the unit to a ground 1 Crimp a ring terminal onto the stripped end of 14 AWG or heavier copper ground wire 2 Remove the screw marked by the ground symbol C L at the right side of the front panel 3 Fasten the ring terminal to the front panel using the same screw 4 Attach the ground wire to an earth ground oooodqQQ To Earth Ground 03 17 2600 A2 GN20 40 March 2005 2 11 2 Cabling Connecting to Power The BitStorm 2600 can be powered by any AC power source supplying 90 265 VAC at 47 63 Hz p Procedure To connect the BitStorm 2600 to a power source 1 Insert the supplied power cord into the power socket on the back of the unit ET 02 17248 2 If the BitStorm 2600 is in a rack dress the power cord to the left and fasten it to the rail with a cable tie 3 Connect the other end of the power cord to a grounded AC power source 4 Make sure the STATUS LED on the front panel is ON green See Chapter 3 LEDs 2 12 March 2005 2600 A2 GN20 40 LEDs LED Locations The locations of the System and DSL Port LEDs on the front panel of the BitStorm 2600 are shown in Figure 3 1 Front Panel LEDs
37. op 1 12 screws for wall mount 1 11 self retaining nuts 1 8 unit into rack 1 8 unit on wall 1 10 IN 2 interfaces C 2 J jack screw 2 2 L LEDs 3 1 License Agreement B Link LEDs 3 2 login 4 4 lug for grounding 2 11 M management modes 4 4 Management port 2 7 cabling 2 7 connector A 3 description 1 3 pin assignments A 3 menu tabs 4 6 MLPPP 2 5 modem connecting to Console port 2 9 mounting brackets description 1 6 mounting configurations 1 2 1 6 N network management systems 4 8 NMS 4 8 O operating environment C 2 optional mounting brackets 1 6 order numbers B 1 out of band management configuring 4 5 described 4 4 overview cabling 2 1 configuration 4 1 management modes 4 4 of BitStorm 2600 1 1 of book iii P package contents 1 4 part numbers B 1 password 4 4 changing 4 7 default 4 4 PC cabling and settings 2 8 physical dimensions C 2 March 2005 2600 A2 GN20 40 pin assgnments E1 A 5 pin assignments A 1 Alarm A 6 CONSOLE port A 3 Console port A 5 Management port A 3 Port 3 A 3 Ports 1 and 2 A 3 RJ21X connectors A 2 SFP socket A 4 T1 A 5 Telco connectors A 2 Port 1 cabling 2 7 description 1 3 pinouts A 3 Port 2 cabling 2 4 description 1 3 pinouts A 3 Port 3 cabling 2 3 description 1 3 pinouts A 3 A 4 SFP socket pin assignments A 4 POTS connector pin assignments A 2 POTS splitter cabling 2 3 pin assig
38. or locations or Paradyne worldwide office locations use one of the following methods m Internet Visit the Paradyne World Wide Web site at www paradyne com Be sure to register your warranty at www paradyne com warranty m Telephone Call our automated system to receive current information by fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or send e mail to userdoc 9 paradyne com Include the number and title of this document in your correspondence Please include your name and phone number if you are willing to provide additional clarification Trademarks Acculink ADSL R Bitstorm Comsphere DSL the Easy Way ETC Etherloop FrameSaver GranDSLAM GrandVIEW Hotwire the Hotwire logo iMarc Jetstream MVL NextEDGE Net to Net Technologies OpenLane Paradyne the Paradyne logo Paradyne Credit Corp the Paradyne Credit Corp logo Performance Wizard ReachDSL StormPort TruePut are registered trademarks of Paradyne Corporation Connect to Success Hotwire Connected JetFusion JetVision MicroBurst PacketSurfer Quick Channel Reverse Gateway Spectrum Manager and StormTracker are trademarks of Paradyne Corporation All other products or services mentioned here
39. pter 4 Configuration Describes the minimal configuration steps required to prepare the BitStorm 2600 for remote access using the command line interface and web interface Appendix A Connectors Provides pinouts for connectors on the BitStorm 2600 and Pin Assignments Appendix B Equipment List Provides part numbers for the BitStorm 2600 and related products Appendix C Technical Lists the technical characteristics of the BitStorm 2600 Specifications Index Lists key terms acronyms concepts and sections in alphabetical order A master glossary of terms and acronyms used in Paradyne documents is available on the World Wide Web at www paradyne com Select Support gt Technical Manuals gt Technical Glossary 2600 A2 GN20 40 March 2005 iii About This Guide Related Product Documents iv Documentation for the BitStorm 2600 IP DSLAM is available on the World Wide Web at www paradyne com Select Support gt Technical Manuals Document Number Document Title 2600 A2 GB21 BitStorm 2600 and GranDSLAM 4200 IP DSLAM Command Line Interface Reference Describes the Command Line Interface CLI used to configure and monitor the BitStorm 2600 IP DSLAM 2600 A2 GB22 BitStorm 2600 and GranDSLAM 4200 IP DSLAM SNMP Reference Contains the information necessary to use Simple Network Management Protocol SNMP to configure and monitor the BitStorm 2600 IP DSLAM 2600 A2 GT20 Bit
40. required 2600 A2 GN20 40 DSL Ports on page 2 2 GigE Uplink Port 3 on page 2 3 10 100BaseT Uplink Port 2 on page 2 4 T1 or E1 Uplink on page 2 5 Chaining BitStorm 2600s on page 2 6 Management Port on page 2 7 Console Port on page 2 8 Alarm Interface on page 2 10 Ground on page 2 11 Connecting to Power on page 2 12 March 2005 2 1 2 Cabling DSL Ports The BitStorm 2600 DSL connector supports the tip and ring connections of up to 24 DSL ports over a 50 position cable A POTS plain old telephone service splitter connector is also provided for CO applications only The internal splitter includes an ANSI T1 413 compliant Maintenance Test Signature MTS circuit If your model does not contain the integrated POTS splitter you must connect the unit to a separate POTS splitter The Model 6051 POTS Splitter must be used for customer premises applications in Canada p Procedure To cable the DSL Ports 1 Insert a cable tie provided through the top of the anchor mount next to the DSL PORTS 1 24 connector 2 If the connector for your cable has a short captive screw attach the cable to the DSL PORTS 1 24 connector and fasten it to the jack screw with its short captive screw 4 40 Anchor Jack Screw Mount 02 17083 Connector 3 If the connector for your cable has a long captive screw remove the provided jack screw from the threaded hole next to the DSL PORTS 1 24 connector Attach the DSL PO
41. rt c60000900900 N CONSOLE Port 03 17448 2600 A2 GN20 40 March 2005 2 9 2 Cabling Alarm Interface 2 10 The ALARM interface consists of five contacts Three of the contacts provide access to alarm relays that that can be used to set off Major and Minor physical alarms The other two contacts provide access to a sense circuit that can be used to detect the open or closed condition of an external alarm relay A 5 position plug provided in the hardware kit is used to connect 20 28 AWG wire to the ALARM terminal block see Table 1 2 Contents of Hardware Kit Shipped with the BitStorm 2600 in Chapter 1 nstallation The contacts are closed during normal operation They open in response to loss of power hardware failure or other alarm conditions See ALARM Connector in Appendix A Connectors and Pin Assignments for more information CAUTION The ALARM Sense and Sense contacts are intended to be connected to an external alarm relay Do not apply power to these contacts doing so will result in damage to the unit p Procedure To connect the ALARM interface 1 Strip the tips of the alarm source wires about 1 2 inch 13 mm 2 Use a screwdriver to press the orange spring tab in while inserting the wire into the hole below it The insulation should be fully within the plug and no bare wire should be exposed outside of the plug 02 17328 3 Insert the plug into the ALARM interface on the fr
42. s 4 8 connectors A 1 ALARM A 6 CONSOLE port A 3 DSL ports A 2 front panel A 1 Management port A 3 Port 3 A 4 POTS splitter A 2 T1 E1 uplink A 5 CONSOLE port 2 8 cabling and settings 2 8 connecting modem 2 9 connector A 3 description 1 3 pin assignments A 3 pinouts A 5 contents of shipping carton 1 4 cooling and air handling C 1 D DB9 cabling 2 8 pinouts A 5 default gateway 4 2 default password 4 4 changing 4 7 desktop installation 1 12 dimensions C 2 document purpose iii documents online iii ordering iv related iv DSL ports cabling 2 2 description 1 3 LEDs 3 2 pin assignments A 2 March 2005 IN 1 Index E E1 uplink cabling 2 5 pin assignments A 5 earth ground 2 11 Electromagnetic Compatibility EMC C 1 EMS 4 4 Enter key 4 2 environment C 2 equipment list hardware provided 1 5 package contents 1 4 part numbers B 1 ESD precautions 1 4 Ethernet LEDs 3 2 pinouts A 3 F fasteners provided 1 5 feature numbers B 1 feet 1 12 front panel 3 1 A 1 illustration A 1 LEDs 3 1 G GigE uplink 2 3 glossary URL iii grounding screw 2 11 H hardware kit contents 1 5 I inband management configuring 4 5 described 4 4 initialization procedures 4 4 installation 1 1 options 1 2 installing feet for shelf installation 1 12 in rack 1 8 mounting brackets for rack mount 1 6 mounting brackets for wall mount 1 10 on shelf or deskt
43. terface Reference for the CLI and the online Help for the web interface 2600 A2 GN20 40 March 2005 4 1 4 Configuration Using the CLI A command line interface CLI can be used to configure and monitor the unit The CLI is available from a PC or terminal connected to the Console port or from a Telnet session with the device The following commands are available Table 4 1 CLI Commands Command Function clear Clear the system log configure Enter Configuration mode Copy Copy from one file to another date Set the time zone and date format end If user is in Administrator mode shifts to User mode if user is in User mode positions interface at top of menu tree exit Terminate current session firmware Download or apply new firmware paging Enable or disable paging more prompt for this session privilege Enable administrator mode restart Restart a unit show Display configuration statistics and status technical support Display information for contacting technical support test Test the system Descriptions of some essential configuration commands follow Configure Management Default Gateway Address The configure management default gateway command specifies the IP address of the next hop router for the management traffic configure management default gateway fip address Minimum Access Lev
44. that the brackets rest against the front of the rails Insert screws in the bottom screw positions and hand tighten them 1 8 March 2005 2600 A2 GN20 40 1 Installation 3 Insert and tighten the screws in the top screw positions then tighten the bottom screws IN 200000000 00000 oooodQ Oleeeecoecoecoocooo X G KAA 03 17436 A 2600 A2 GN20 40 March 2005 1 9 1 Installation Installing the BitStorm 2600 on a Wall Wall mounting requires two wood screws suitable for the weight of the fully cabled unit These are not included Use at a minimum 1 4 inch 6 mm diameter screws in 3 4 inch 19 mm plywood not drywall p Procedure To install the BitStorm 2600 on a wall 1 Identify the flat head screws provided in the hardware kit and the brackets suitable for a 23 inch rack Two screws are required for each bracket 2 Orient the unit so that the bottom is facing you and the faceplate is at the top 3 Locate the supplied Right Side mounting bracket and fasten it to the right side of the unit 04 17522 4 Locate the supplied Left Side mounting bracket and fasten it to the left side of the unit 5 Tighten all screws firmly 1 10 March 2005 2600 A2 GN20 40 1 Installation 6 Install two wood screws not provided at the same height above the floor and 18 75 inches 476 25 mm apart Do not completely tighten the screws Leave them
45. um Model 2624 55 Watts Maximum Model 2631 57 Watts Maximum Model 2671 46 Watts Maximum Model 2674 44 Watts Maximum Weight 2611 without splitters 15 1 Ib 6 8 kg 2611 with splitters 17 0 Ib 7 7 kg 2614 13 1 Ib 5 9 kg 2621 without splitters 14 7 Ib 6 7 kg 2621 with splitters 16 3 Ib 7 4 kg 2624 12 2 Ib 5 5 kg 2631 without splitters 14 7 Ib 6 7 kg 2631 with splitters 16 3 Ib 7 4 kg 2671 15 5 Ib 7 0 kg 2674 13 1 Ib 5 9 kg C 2 March 2005 2600 A2 GN20 40 Index Numerics 10 100BaseT pinouts A 3 1000BaseT pinouts A 3 A AC power 2 12 Activity LEDs 3 2 administrator login 4 4 Alarm connector pinouts A 6 LED 3 2 port cabling 2 10 port connectors A 6 port description 1 3 audience for this document iii autosensing 2 4 2 7 B BitStorm 2600 description 1 1 brackets installation for rack mount 1 6 C cables A 1 DSL ports A 2 MGMT port A 3 required 1 3 cabling 2 1 ALARM port 2 10 console port 2 8 DSL ports 2 2 GigE uplink 2 3 ground 2 11 management port 2 7 Port 1 2 7 Port 2 2 4 Port 3 2 3 POTS ports 2 2 power 2 12 T1 E1 MLPPP 2 5 uplink 2 4 2 5 CO alarm system 2 10 CO grounding screw 2 11 Command Line Interface CLI 4 2 2600 A2 GN20 40 commands 4 2 community strings 4 8 configuration 4 1 CLI commands 4 2 mounting brackets 1 6 configuring inband management 4 5 out of band management 4 5 SNMP parameter
46. untries other than North America is to be a minimum HO5 V V F type min 0 75 mm 2 conductor and earth ground terminated in an IEC 320 connector on one end and a plug which is certified for use in the country of installation at the other end 14 Do not physically stack more than eight 8 26x1 units high Physical stability has not been evaluated for stacking higher than eight units and any configuration greater than eight may result in an unstable tip over condition Ensure that the four 4 rubber feet supplied with the product have been installed on the bottom of each unit prior to stacking any 26x1 units on top of one another EMI Notices UNITED STATES EMI NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equip
47. vironment a Model 6051 POTS Splitter must be used to ensure CS 03 compliance Refer to the POTS splitter installation instructions for details CE Marking When the product is marked with the CE mark on the equipment label a supporting Declaration of Conformity may be downloaded from the Paradyne World Wide Web site at www paradyne com Select Library gt Technical Manuals gt CE Declarations of Conformity 2600 A2 GN20 40 March 2005 D Japan Class A ITE COREL BI SEBIAEHEMGEREIEUMIIEE VCCI ORM KCREOGZZ2AASBSBNEBCI CODSIEETXERS CHATS CBR PET VNERIOTCEMHVET O88 EAUBUP CES k5ZSkeneccA50zj This is a Class A product based on the standard of the Voluntary Control Council for interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions E March 2005 2600 A2 GN20 40 Contents m Software and Firmware License Agreement llus B About This Guide Document Purpose and Intended Audience iii Document Summary ssslleele eres iii Related Product Documents lllllleellleleeesn iv 1 Installation B OVOIVIOW iul curi Eius eae a dps pot M E Ee ARR ate 1 1 B Preparations ated Beh uu RUE PX ACER eee 1 2 m Cables Required 0 c eee 1 3 m Unpacking the Hardware 0 0 00 eee 1 4 m Package Contents
48. xt to it 3 Click on Modify Selected The System Users admin screen appears 4 Type in a new Login Password and a new Privilege Password then click on Apply Keep a record of the new password 2600 A2 GN20 40 March 2005 4 Configuration Configuration Management SNMP SNMP access to the unit is disabled by default The read only community string is public and the read write string is private Community strings network management system addresses and trap manager addresses can be set using the System Management SNMP screen p gt Procedure To set SNMP parameters 1 Click on the Configuration menu tab then click on SNMP The System Management SNMP screen appears Related status State Enabled Public String read only public Private String read write private SNMP Access Validation Disabled Manager IP Addresses Trap IP Addresses Apply 2 Enter new SNMP parameters as desired Click on Apply 4 8 March 2005 2600 A2 GN20 40 Connectors and Pin Assignments Overview The following sections provide pin assignments for m DSL Ports and POTS Splitter Connectors on page A 2 m Port 1 and Port 2 10 100BaseT Connectors on page A 3 m Port 3 1000BaseT Connector on page A 3 m Port 3 GigE SFP Connector on page A 4 m E1andT1 Uplink Connectors on page A 5 m Console Port Connector on page A 5 m ALARM Connector on page A 6
49. you are not sure of the proper static control precautions contact your nearest sales or service representative The BitStorm 2600 is shipped in a cardboard shipping container Carefully remove the unit from its shipping container and check for physical damage If the unit shows signs of shipping damage notify your sales representative Package Contents In addition to this installation guide the BitStorm 2600 shipping carton should contain BitStorm 2600 DSLAM AC Power Cable Two sets of mounting brackets one set suitable for a 19 inch 483 mm rack and one set suitable for a 23 inch 584 mm rack including Bay Networks and Nortel Hardware kit see Table 1 2 Contents of Hardware Kit Shipped with the BitStorm 2600 If anything is missing notify your sales representative Before installing the BitStorm 2600 read the mportant Safety Instructions in the beginning of this document Be sure to register your warranty at www paradyne com warranty March 2005 2600 A2 GN20 40 2600 A2 GN20 40 1 Installation Table 1 2 Contents of Hardware Kit Shipped with the BitStorm 2600 Appearance Description Quantity Flat head screw for attaching 19 mounting brackets to 6 yr unit 02 17259 RN Machine screw with captive starwasher 6 32 x 1 4 for 6 attaching 23 mounting brackets to unit SV 02 17326 Self retaining nut for racks without threaded holes 4 X 02 17256 Dress screw 12 24