1. O Press the or V buttons to change the clock to the desired time for the unit to automatically turn off The TIMER OFF indicator will flash for 3 seconds to activate the times you programmed NOTE The timer will also remember your settings when it is set If you set the timer while in Air Condition ing mode the timer will automatically turn the unit on and off in air conditioning mode according to the de sired programmed times The timer will also remember the temperature settings fan speed and oscillation set ting The timer works when the unit is in Air Conditioner mode Heating mode Dehumidifier mode Fan mode and Auto mode OPERATING THE UNIT USING THE CONTROL PANEL Air Conditioner Mode 1 Install the exhaust hoses and window kit properly see pages 6 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER button on the control panel 4 Press the Mode button until the icon appears on the Multi color display 5 Press the or V buttons until the desired room temperature appears on the control panel display The temperature ranges from 61 F 88 F 16 C 31 C 6 Select the desired fan speed by pressing the FAN button NOTE During hot days the unit will cool the room most efficiently by setting the temperature at the lowest setting and the fan speed on high Reducing the length of the exhaust duct insulating the exhaust hose and window kit and keeping direct sunli
2. icon appears on the control panel display 4 Press the Vor buttons until the desired room temperature appears on the control panel display The temperature ranges from 61 F 88 F 16 31 C 5 Select the fan speed by pressing the FAN button It is recommended to set the fan speed to low NOTE It is not necessary for the exhaust hoses and window kit to be installed to operate the unit in heating mode Auto Mode 1 Install the exhaust hoses and window kit properly see pages 6 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER button on the control panel 4 4 Press the MODE button until the VW icon appears on the control panel display Select the fan speed by pressing the FAN button NOTE During AUTO mode the unit operates in Heating mode when the room temperature is below 68 F Dehumidifier mode when the room temperature is between 68 F to 80 F And Air Conditioner mode when the room temperature is above 80 F Sleep Mode This mode can only be selected when using the Remote control 1 To set Sleep mode make sure the unit is in Air Conditioner mode 2 Press the SLEEP Button on the remote control The icon appears on the control panel display 3 When in SLEEP mode the fan will run on low to keep fan noise at a minimum 4 When in Air Conditioner mode the temperature setting will gradually increase to 2 F above the original set temperature for 6 hours After
3. SPEED Button to cycle through the different fan speeds High Medium and low The fan speed can be visually distinguished by the speed of the digital air segments progressing out from the windmill fan image on the Multi color display There is an additional auto speed setting that 15 enabled in only heating and cooling modes This speed is next setting after low when press ing the speed control button The speeds will cycle through in this order Low Medium High Auto Each change in speed will be associated with a beep sound from the unit 4 Temperature Select the desired temperature by pressing either V or key when using the unit in cooling or heating mode The temperature indicator flashes to display the desired temperature setting After the temperature is set the unit will display this temperature setting until it is changed by the user The Multi color display shows temperature in Celsius or Fahrenheit Press the V or simultaneously to change from C to F 5 SWING To turn on the exclusive WAVEFLO oscillation press the SWING button on the control panel Once you press SWING the louvers on the unit will oscillate up and down and back and forth 6 Timer To program the timer press the TIMER ON button until the display shows a flashing X Press or V buttons to change the clock to the desired time for the unit to automatically turn on o Press the TIMER OFF button and the display on the unit will flash
4. a gravity drain or larger pan for continuous drainage It is not advised to use continuous drainage when the room temperature is higher than 90 F 10 eee OPERATING THE UNIT USING THE REMOTE CONTROL REMOTE CONTROL LCD DISPLAY MODE BUTTON POWER BUTTON FAN SPEED Mo H ls TEMP SETTING O TIMER ON SWING LOUVER OSCILLATION SLEEP BUTTON TIMER OFF HOUR SELECTER MINUTE SELECTER REMOTE CONTROL OPERATING INSTRUCTIONS 1 2 3 4 5 6 7 Power On and Off Press the POWER I O button once to manually turn the unit on Press the Power button once more to turn the unit off When you press the POWER button the upper right square on the remote control LCD Display will light up When in Air Conditioner Heating and Auto mode the selected temperature will appear on the remote control display When the unit is in Fan mode and Dehumidifier mode you will see the icon instead of the set temperature This shows that temperature selection is not available when the unit is in Fan or Dehumidifier mode Mode Selection Press the MODE Button repeatedly to cycle between the different modes Auto Air Conditioner Dehumidifier Fan only and Heater mode The upper left square on the Remote control dis play will light up showing which mode is selected In Air Conditioner mode the display will show COOLING in Heating mode the display will show HEAT in Dehumidi
5. of the remote control display will show the lt icon when WAVEFLO oscillation SWING is selected TIMER To program the timer first press the T ON button Once T ON is pressed the auto on timer will blink in the bottom right rectangle of the remote control display Press the MIN and HOUR buttons to change the clock to the desired time for the unit to automatically turn on The minutes will increase by 10 with each press of the MIN button and the hours will increase by 1 with each press of the HOUR button Press the T OFF button and the remote control display will flash the desired auto off timer Press the MIN and HOUR buttons to change the clock to the desired time for the unit to automatically turn off The timer is set when the auto off time stops flashing and the words ON and OFF are displayed next to the time CLOCK To set the clock on the remote control hold down either the MIN or HOUR button until the displayed time flashes on the remote control display Change the minutes by pressing the MIN button and change the hours by pressing the HOUR button 12 MAINTENANCE Note Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit Clean or replace filter If the air filter 1s blocked with a dust the airflow volume may reduce It is recommended to clean the filter once every two weeks or as needed 1 Remove the filter from th
6. 6 hours the temperature setting will return to the set temperature 5 When in Heating mode the temperature setting will gradually decrease to 2 F below the original set tem perature for 6 hours After 6 hours the temperature setting will return to the set temperature 6 When in Dehumidifier mode the temperature will not change when Sleep mode is selected Compressor Indicator 0 The icon will light the control panel display when compressor turns The turn off when the compressor shuts off 1 icon will Emergency Condensate Holding Tank When the room temperature is low and the indoor humidity is high the air conditioner may not be able to evaporate some of the moisture fast enough When this happens the water will accumulate in an emergency condensate tank inside the unit Once the emergency condensate tank is full the unit will automatically shut off and the vv will appear on the control panel display To empty the condensate tank pull the drain plug at the bottom back of the unit You will need a small pan approximately 1 high to catch the water coming out of the condensate tank Once the condensate tank is drained the unit will begin working within a few minutes The emergency condensate tank is approximately 1 5 Liters of water Another option 15 to purchase a small hose from a hardware store that can fit around the 5 8 drain plug on the back of the unit and drain the unit into
7. Do not use an adapter plug or extension cord Do not use the unit in the immediate surroundings of a bath a shower or a swimming pool Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills unless instructed by this manual Do not let children play near this unit 10 Always inspect the cord for signs of damage before use If the power cord is damaged it must be replaced by the manufacturer or a qualified service technician 11 When cleaning the unit always turn the unit off and unplug the power cord PACKAGE CONTENTS Portable Air Conditioner Exhaust Hoses 2 Hose Adapters 2 Window Kit Adapter 2 Remote Control AAA Batteries 2 Window Kit 3 Sliding Panels 1 dual hose panel 2 extension panels Air Intake and Outlet Covers 2 Owner s Manual SPECIFICATIONS e The cooling capacity is measured at an ambient temperature of DB 86 F WB 78 F e Noise level is measured at a distance of 3 28 ft away from the front of the unit when the unit is in cooling mode e Power consumption is measured when the fan runs at the highest speed setting e These specifications are for reference only For actual data please refer to the rating label on the back of the unit e Ifthe environment temperature is higher than the max operating temperature or lower than the minimum operating temperature the air conditioner may not work properly 115 V 60 HZ POWER SOURCE 9 12 AMP 12 12 AM
8. P COOLING HEATING SOUND PRESSURE LEVEL 46 dB A NET WEIGHT 76 Lbs 82 Lbs OPERATING COOLING 60 8 F 107 6 F TEMPERATURE Ea p ASSEMBLED 17 5 W X32 75 H X19 D DIMENSIONS PACKAGE 22 47 W X 34 44 H X 19 88 D PRODUCT DIAGRAM Control Panel Louvers Signal Receptor Casters e Back Filter Compartment Air Outlet Hose Evaporator Air Intake Air Intake Hose Air Intake Cover Filter PARTS amp ASSEMBLY PARTS EXHAUST HOSES Exhaust Hose Hose Adapter Window Kit Adaptor WINDOW KIT ASSEMBLY amp INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier the unit draws in fresh outdoor air and exhausts hot air out of the room to complete the air exchange When the unit is operating in fan or heater modes no outdoor air exchange takes place The window kit and exhaust hose do not need to be installed when the unit is used as a fan or heater NOTE The supplied window kit can be installed in sliding windows and sliding glass doors up to 8 ft long approximate length MOUNTING THE EXHAUST HOSES e Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components e Extend both ends of the exhaust hoses approximately 6 inches e Screw the window kit adapter onto one end of the exhaust hose clockwise Screw the hose adapter onto the other end of the exhaust hose clockwise Repea
9. SOLEUSAIB 10 000 12 000 B TU Portable Air Conditioner LX 100 LX 100BL LX 120 LX 120BL Operating Instructions 4 D Model No LX 100 120 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner This owner s manual will provide you with valuable information necessary for the proper care and maintenance of your new product Please take a few moments to thoroughly read the instructions and familiarize yourself with all the opera tional aspects of your new Soleus Air Portable Air Conditioner For your own records please attach a copy of your sales receipt to this manual Also write the store name location date purchased and serial number below Store Name Location Date Purchased Serial Number located on back of unit ET IMPORTANT INSTRUCTIONS Before installing and using your portable air conditioner please read this owner s manual carefully Store this manual in a safe place for future reference 1 2 3 4 5 6 7 8 9 Always place the unit on a level surface Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles The unit must be connected to a correctly grounded power supply Do not start or stop the unit by inserting or pulling out the power plug
10. e filter compartment on the back of the unit 2 Wash the air filter by immersing it gently into warm water with a neutral detergent Rinse the filter and dry it thoroughly out of sunlight 3 Slide the filter back into the filter compartment after it is thoroughly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the watranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess water by unplugging the water drainage stop in the back of the unit located at the bottom 2 Unplug the unit 3 The unit should be stored in a cool dry place DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 13 22 4 WARRANTY One Year Limited Warranty Soleus International Inc warrants the accompanying Soleus Air Portable Air Conditioner to be free of defects in mate rial and workmanship for the applications specified in its operation instruction for a period of ONE 1 year from the date of original retail purchase in the United States If the unit exhib
11. fier mode the display will show DRY in Fan mode the display will show FAN and in Auto mode the display will show AUTO Fan Speed Press the FAN speed button to cycle through low medium and high fan speeds The dis play on the remote control will show LOW MED amp HIGH under the SPEED label on the remote con trol LCD display There is an additional auto speed setting that is enabled in only heating and cooling modes This speed is next setting after low when pressing the FAN speed button on the remote control The speeds will cycle through in this order High Medium Low Auto Each change in speed will be as sociated with a beep sound from the unit The remote control will not display AUTO under the speed label Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on the remote control Temperature Setting When the unit is in Air Conditioner or Heating mode you can select your desired temperature Press the A or V to select your desired temperature setting The temperature on the LCD dis play on the remote control will increase or decrease accordingly Pressing the V and A buttons simultane ously will change the temperature select between F and C SWING To turn on the exclusive WAVEFLO oscillation press the SWING button on the remote control Once you press SWING the louvers on the unit will oscillate up and down and back and forth The bottom left square
12. ght to a minimum will also improve the cooling efficiency Dehumidifier Mode 1 Install the exhaust hoses and window kit properly see pages 6 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button on the control panel 4 Press the MODE button until the 5 appears the control panel display NOTE The unit operates at low fan speed during dehumidifier mode The unit cools room slightly during the dehumidification Keep the windows and doors closed to aid the effectiveness of the unit in removing the moisture from the room NOTE The unit will not perform in dehumidifier mode when the room temperature is lower than 61 F Fan Mode 1 Plug the Power Cord into an electrical outlet 2 Turn on the unit by pressing the POWER button on the control panel 3 Press the MODE button until the 25 icon appears the control panel display 4 Select the fan speed by pressing the FAN button 5 To circulate more air press the SWING button on the remote control The louvers will oscillate in our exclusive WAVEFLO pattern back and forth and up and down spreading more air throughout the room NOTE It is not necessary for the exhaust hoses and window kit to be installed to operate the unit in fan mode Heating Mode 1 Plug the Power Cord into an electrical outlet 2 Turn on the unit by pressing the POWER button on the control panel S D 3 Press the MODE button until the N
13. he kit and cut down one end to properly fit the opening figures g amp h 7 Attach the window kit adapters to the window kit figure i Close the window or door tightly figure j Your Portable Air Conditioner is now ready to cool NOTE When using the venting system keep the exhaust hose as short and straight as possible The exhaust hose can be shortened but it is not recommended to increase the length of the exhaust hose Do not use an extension cord with your portable air conditioner CONTROL PANEL DISPLAY amp OPERATING INSTRUCTIONS CONTROL PANEL amp MULTI COLOR DISPLAY CONTROL PANEL TEMP amp TIMER SELECTION POWER BUTTON MODE BUTTON TIMER BUTTONS SWING LOUVER OSCILLATION FAN SPEED BUTTON MULTI COLOR DISPLAY AUTO AIC DEHUM FAN HEAT TIMER ON TIMER OFF NZ f TEMPERATURE lt gt AND TIMER N l INDICATOR ZN V C OSCILLATION ON OFF COMPRESSOR ON OFF EMERGENCY SLEEP MODE ON OFF CONDENSATE BUCKET FULL FAN SPEED OPERATING INSTRUCTIONS CONTROL PANEL BUTTONS Refer to the images on page 7 1 Power On and Off Press the POWER button once to manually turn the unit on Press the POWER button once more to turn the unit off 2 Mode Selection Press the MODE Button repeatedly to cycle between the different modes Auto mode Air Conditioner Dehumidifier Fan only and Heater 3 Fan Speed Control Press the FAN
14. its a defect in normal use Soleus International Inc will at its option either repair or replace it free of charge within a reasonable time after the unit 1s returned during the warranty period As acondition to any warranty service obligation the consumer must present this Warranty Certificate along with a copy of the original purchase invoice THIS WARRANTY DOES NOT COVER e Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship e Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions e Damage to the finish of the case or other appearance parts caused by wear e Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc e Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT This warranty covers only new products purchased from our authorized dealers or retailers It does not cover used sal vaged or refurbished products As some s
15. t on the other exhaust hose e Remove outlet covers from the back of the unit by screwing them counter clockwise then lifting up e Mount the exhaust hoses onto the back of the unit by locking the hose adapters into place DUAL HOSE WINDOW KIT INSTALLATION Innovative products for a cleaner Installation of the Venting Kit more comfortable world FOR DUAL HOSE PORTABLE AIR CONDITIONERS The venting kit must be installed in order for the unit to work correctly in the air conditioning heating or dehumidifying mode The venting kit does not need to be used while the unit is fanning The window kit has been designed to fit into most vertical and horizontal window openings The window kit can also be used in a sliding door 1 Choose a suitable location near a grounded electrical outlet and a suitable window or door Remove packaging and locate components figure a 2 Remove the outlet covers from the back of the unit by screwing them counter clockwise then lifting up figure b 3 Pull out one end of the exhaust hose then screw on the adapter clockwise Repeat on other exhaust hose figure c 4 Pull out the opposite end of the exhaust hose then screw on the window kit adapter clockwise Repeat on other exhaust hose figure d 5 Mount the exhaust hoses onto the back of the unit figure e 6 Open the window or door and adjust the length of the window kit to fit the opening figure f If necessary mark t
16. tates do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Technical Support amp Warranty Service Please Call 888 876 5387 Or Write To Soleus International Inc 9451 Telstar Ave El Monte CA 91731 USA www soleusair com 14