1. Measurement of blood pressure may not be possible for someone with a weak pulse or cardiac arrhythmia 2 This product is not intended to be used in the diagnosis or treatment of disease 3 If you have high blood pressure and or other cardiovascular conditions or diseases this device should be used in consultation with your doctor 4 Consult your doctor if you have questions about your blood pressure or pulse 5 Specifications are subject to change without notice due to improvements in performance Two Year Limited Warranty The Lumiscope Company Inc guarantees this product free from defects in material and workmanship for a period of two years from the date of purchase except as noted below This Lumiscope product warranty does not cover damage caused by misuse or abuse the attachment of any unauthorized accessory alteration to the product or any other conditions whatsoever that are beyond the control of the Lumiscope Company Inc Lumiscope shall not be responsible for any type of incidental consequential or special damage All implied warranties including but not limited to those implied warranties of fit ness and merchantability are limited in the total duration of two years from the original date of purchase To obtain warranty service on your Lumiscope Blood Pressure Meter either hand deliver or mail the entire unit and your dated sales receipt as proof of purchase postpaid along with a certified check or
2. of results e When pressing the Memory Recall switch the memory cell number is displayed The stored measurement results systolic diastolic blood pres sure are then displayed The display will show the 9 memorized pressure and pulse value switching LI back and forth e If the Memory Recall switch is pressed again the prior measurements are displayed in the order they were taken Tinang TIME ie Be Memory Clear Function You may erase one or all records in the memory L wy ePress and release MEMORY key to choose the i record that you wish to delete j al ePress and hold the ON OFF key until the display shows dEL eDelete one record Press and release the power key After three beeps are heard the record is completely deleted eDelete all records 1 Press and release the MEMORY key then the display shows dEL ALL 2 Press and release the ON OFF key After three beeps are heard the unit erases all records 3 Remove one or both batteries while the unit is on Description of Display Marks DISPLAY MARK CONDITION CAUSE CORRECTIVE ACTION LL Err The pressure measured was less than 20 mmHg Please measure again ut Err The pressure measured was higher than 300mmHg Please measure again p Err Pumping error Please check the cuff and try again HI The pumping pressure is higher than 300mmHg Please
3. LUMISCOPE Blood Pressure Monitor Instruction Manual Model Number 1098 ID Requires 2 AAA Alkaline Batteries Di WARRANTY TABLE OF CONTENTS Identification OF Parts caricia ie 3 Battery Installation Replacement o o ooo ooooooooo 4 AS ie si Cuff and Posture During 4 Measurement osi Di Feed e 5 SUBSEQUENT Measurement iria a ea 6 Automatic Power off Function oooooooooooomoo 6 Memory ReCdll eserves aetna de eee E oe aware ee 7 Memory Clear Function o 7 Description of Display Marks 8 Specifications AA AA AA 9 Warranty aaa DANG A ads de 10 Identification of Parts Memory Key ON OFF Key Wrist Cuff 2 AAA type battery LCD Display Systolic Pulse mark anny BBA MEMORY EM 888 Memory Low battery mar 3 Battery Installation Replacement e To use the unit you must install batteries e Open battery cover as illustrated Install or replace two new batteries making sure the polarities and on the battery match the polarities on the case e Replace battery cover e If the Low Battery indicator ai appears on the display both batteries must be replaced e AAA alkaline batteries or equivalent are suit able for this blood pressure meter Attaching the Wrist Cuff and Posture During Measurement e The blood pressure is measured at the wrist Therefore rolling up the sleeve is no longer
4. a po gt I e Turn Power off Press the ON OFF switch to turn off mal I a n a as tend NOTE To discontinue a measurement for any reason press the Power Start switch This causes the wrist cuff to rapidly deflate Subsequent Measurement When a measurement needs to be made again the time between 2 measurements must be at least 10 minutes Automatic Power OFF Function If the unit is left on after measurement an Automatic Power OFF Function turns the power off after approximately 3 minutes To continue with another measurement press the ON OFF switch to turn the unit on Setting the Clock Enter the setting mode by pressing and hold ing the MEMORY key for over three seconds 28 i The display will show a blinking year Press the ON OFF key to adjust the year when it is e tb blinking Then press and release the MEMO RY key again the month will apear and blink to be adjusted then the date hour and minute will follow up as you press and release the PAB MEMORY key again Adjust the clock by pressing the MEMORY key to adjust the values of the month date hour and minute when they are blinking Memory Recall e You can recall stored data by pressing the Memory Recall switch at any time EXCEPT while taking a measurement e Up to 42 sets of measurement results can be stored in memory Memory cell No 1 is always used to store the newest set
5. measure again or no display Batteries are weak Replace the batteries There is a problem with the device Return to Lumiscope service Department Specifications Model No 1098 Measuring Principle Full Fuzzy Auto Oscillometric Method Measurement Localization Left Wrist Cuff Soft Cuff Wrist Circumference Range 5 4 to 7 8 in 13 5 to 19 5cm Measurement Pressure 20 to 300 mmHg Range Pulse 40 to 200 Pulses min Pressure 3 mmHg Accuracy Pulse 5 of reading o blood pressures 3 digits E LCD iastolic blood pressure 3 digits prernatively Indication Pulse rate 3 digits Measuring o Marke Battery a LCD View Size 1 44 H x 904 W in 36 H x 22 6 W mm Digit Size 44 H x 22 Wjin 11 H x 5 5 W mm Switch ON OFF switch Memory recall switch Inflation i i Internal Pump Exhaust Deflation Valve Rated Voltage 3 VDC Power Source 2 AAA Size Batteries Power Consumption 1 0W Battery Life Approx 250 measurements Automatic Power Off After 2 minutes or 30 sec of non use Memory Function 42 Memories Function plus date amp time Dimension 80mm W x 80mm D x 30mm H Weight Approx 130g including batteries Operating Temperature 50 to 104 F 10 to 40 C Environment Humidity 30 to 85 RH Storage Temperature 14 to 140 F 10 to 50 C Environment Humidity Less than 85 RH CAUTION 1
6. money order in the amount of 15 00 payable to The Lumiscope Company Inc to cover handling Upon receipt Lumiscope will repair or replace as appropriate Blood Pressure Meter and return to you Warranty is solely through Lumiscope Repair Department Service of this product by anyone other than Lumiscope Repair Department voids warranty In the event that Lumiscope does not abide the terms of this warranty the con sumer may seek breach of contract remedies in the New York State Federal courts of law This warranty gives you specific legal rights and you may also have other rights which vary from state to state Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you o WARRANTY The Lumiscope Company Inc Service Dept 122 Tices Lane East Brunswick N J 08816 tel 732 254 3800 www lumiscope net
7. necessary e Wrap the wrist cuff around your left wrist with the display panel on the inside of the wrist e Pull the wrist cuff to fit wrist size and fasten velcro Wrist circumference 5 4 9in Rest left elbow on a table so that the cuff is at heart level Relax the lower arm across the table and remain still Perform measurements in either a seated or reclining posture with the left palm turned upward The hard carry case should be used as an arm rest with rubber grips facing down against the table Carry Case Measurement NOTE Unit measures on inflation e To start the measurement Press the ON OFF switch e Initial display e Pumping e Measuring and Beeping sounds e Once the blood pressure measurement has stabi lized pressurization is discontinued and the air in the cuff is automatically let out e The buzzer sounds for about 2 seconds and the high and low blood pressure are respectively dis played one above the other e Unless an error is generated the measurement results are automatically stored in memory Up to 42 sets of results can be stored When there are already 42 sets of results in memory the oldest one is automatically erased and overwritten with the newest e Blood pressure values and pulse rate are 12 8 TIME Mu a 5 a alternately displayed The unit will continue to display the measurement until power is turned off E p