Home
Lightolier Baselyte-BSL23 User's Manual
Contents
1. 65 Ibs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stranded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture Note Standard T bar mounts are currently not available for tegular tile ceilings however certain tegular tile T bar combinations may be supported by the use of the slot grid mount For more information please consult factory 1 Power Mount Non Power Mount D Supension Length 1 Power Mount 2 g 8 12 3 Conductor BSLM6102P13 BSLM6104P13 BSLM6108P13 BSLM6112P13 4 Conductor BSLM6102P14 BSLM6104P14 BSLM6108P14 BSLM6112P14 7 Conductor BSLM6102P17 BSLM6104P17 BSLM6108P17 BSLM6112P17 Non Power Mount BSLM6102N BSLM6104N BSLM6108N BSLM6112N 1 Power Mount Non Power Mount Supension Length 1 Power Mount 2 g 8 12 3 Conductor BSLM6202P13 BSLM6204P13 BSLM6208P13 BSLM6212P13 4 Conductor BSLM6202P14 BSLM6204P14 BSLM6208P14 BSLM6212P14 7 Conductor BSLM6202P17 BSLM6204P17 BSLM6208P17 BSLM6212P17 Non Power Mount BSLM6202N BSLM6204N BSLM6208N BSLM6212N 1 Power Mount Non Power Mount Supension Length 1 Power Mount 2 g 8 12 3 Conductor BSLM6302P13 BSLM6304P13 BSLM6308P13 BSLM6312P13 4 Conductor BSLM6302P14 BSLM6304P14 BSLM6308P14 BSLM6312P14 7 Conductor BSLM6302P17 BSLM6304P17 BSLM6308P17
2. 4 Q JE Q ES k 1 Q pja 1 EN SS One 4 section in a one circuit fixture to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to fixture ends All lamps in EC NL section to be wired together 1 Circuit with Emergency Battery Pack EM L Type 5 Chloride standard 1 tla 9 tla o m C700A 4 1 a 1 ASE L Type M Bodine standard 4 a EA T Ae oh F B70A All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected O Type E Chloride high performance to the battery pack and would function as a trigger wire when connected to a constant hot by C1400 installer Leads for both normal circuit and battery pack are wired to fixture ends O Type P Bodine high performance Note Multi lamp battery packs are also available B50 1 Circuit with Emergency Circuit Night Light and Emergency Battery Pack O Type J Chloride standard 4 1 4 Q F S F C700A 1 Q SE 1 E IS 4 1 ae Q E SS One 4 section in a one circuit fixture to be wired on a separate thru circuit in addition a battery pack is wired to one lamp Installer can connect trigger wire to EC hot lead if controlled together or wire separately if controlled independently Leads for normal circuit EC NL and EM wired to fixture ends All lamps in EC NL section to be wired together Note Multi lamp batte
3. A O Type F Chloride high performance hot lead is connected to the battery pack and would act as a trigger wire when connected to a C1400 constant hot by installer Leads for both normal circuit and battery pack are wired to fixture ends L Type Q Bodine high performance Note Multi lamp battery packs are also available B50 2 Circuit Center Outer Switching with Emergency Circuit Night Light and Emergency Battery Pack C Type K Chloride standard P 2 rla O F NX EC NL N F C700A 4 Q JE Q E TS 4 O a 2 E SETS One 4 section in a two circuit fixture center outer switching to be wired on a separate thru circuit in addition a battery pack is wired to one lamp Installer can connect trigger wire to EC hot lead if controlled together or wired separately if controlled independently Leads for normal circuit EC NL and battery pack are wired to fixture ends All lamps in EC NL section to be wired together Note Multi lamp battery packs are also available WIOLFSOM Job Information iT Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 l Lighting Systems Baselyte BSL23 Page 8 of 8 3 Light T8 Indirect Wiring Options 2 Circuit A B Switching alternate 4 sections 2 Circuit A B Switchi
4. BSLM5104N BSLM5108N 2 Power Mount Non Power Mount P Supension Length 1 Power Mount 2 g 8 12 BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM3112P17 BSLM3102P23 BSLM3104P23 BSLM3108P23 BSLM3112P23 BSLM3102N BSLM3104N BSLM3108N BSLM3112N Job Information iT is Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 WIOLFSOM l Lighting Systems Baselyte BSL23 Page 5 of 8 3 Light T8 Indirect O Mount Type Non Accessible Ceilings concrete gypsum etc 1 Power Mount 2 Power Mount Non Power Mount p Supension Length 1 Power Mount 2 g 8 12 3 Conductor BSLM1102P13 BSLM1104P13 BSLM1108P13 BSLM1112P13 ari 4 Conductor BSLM1102P14 BSLM1104P14 BSLM1108P14 BSLM1112P14 e Meets UBC OSHPD and DSA seismic requirements e Canopy Diameter of 5 1 4 x 3 4 power 7 Conductor BSLM1102P17 BSLIM1104P17 BSLM1108P17 BSLM1112P17 e Cable 7x7 stranded aircraft cable 3Power Niou t e Mountable on 0 15 sloped ceiling e Optional Chicago Plenum approved version available A4
5. BSLM6312P17 Non Power Mount BSLM6302N BSLM6304N BSLIMG308N BSLM6312N Job Information xT Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 3 Light T8 Indirect WTOLRFSOM l Lighting Systems Baselyte BSL23 Page 4 of 8 Mount Type T Bar Fixed Position 1 4 20 Threaded Rod N Bo 1 Power Mount 3 Conductor 4 Conductor Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 stranded aircraft cable Tile cut out hole Diameter of 2 1 2 power or 3 4 non power J Box Integral J Box supplied 1 4 20 all thread rod supplied by others Fully vertically adjustable at fixture 2 Power Mount 3 Conductor Non Power Mount Mount Type T Bar Variable Position SOO Lor O E i ED O 5 4 T 1 Power Mount e Meets UBC OSHPD and DSA seismic requirements e Canopy Diameter of 3 x 7 32 e Cable 7x7 stranded aircraft cable e Tile cut out hole Diameter of 2 1 4 e Aligned by T bar and secured to structure e J Box 4 square s
6. lamping options longer runs and runs with wiring options that are more complex Please consult factory for assistance System Components amp Accessories End Set Joiner Dust Cover e a m B SS o BSLESW suspended standard white BSLJS suspended joiner BSLDCS 4 suspended dust cover WTOLRFSOM Job Information i s Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 l Lighting Systems Baselyte BSL23 Page 3 of 8 Mounting Options Mount Type T Bar 15 16 On Grid 65 Ibs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stranded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture Mount Type T Bar 9 16 On Grid o0 65 Ibs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stranded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture Mount Type T Bar 9 16 by 5 16 Slot Grid On Grid lal O D 5 f R
7. 3 Conductor BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 e J Box 4 octogonal box supplied by others e Fully vertically adjustable at fixture Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Cord Types 3 Conductor 4 Conductor LI 7 Conductor C U e Max 10 amps e Max 10 amps in a 1 circuit application e Max 10 amps in a 1 circuit application e Max 300V e Max 5 amps per circuit in a 2 circuit application Max 5 amps per circuit in a multi circuit e Max 300V application e Good for 2 circuit feeds or a 1 circuit feed with e Good for 3 circuit feeds or 2 circuit feeds with a a battery pack hot lead battery pack hot lead e 120V or 277V applications e 120V or 277V applications HIQOLAHSE II Job Information i s Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 l Lighting Systems Baselyte BSL23 Page 6 of 8 3 Light T8 Indirect Wiring Options 1 Circuit 1 Circuit El Type 1 1cct P o ya o rla o F Type 8 1cct w 1cct thru wire 4 Oo ae Oo ae 1 F CO Type H 1cct w 2cct thru wire 4 Q a Q j Q El Type 7 1cct w dimming All lamps wired on one circuit 1 Circuit with Emergency Circuit Night Light EC NL C Type 3 1cct w EC NL F o a o r ee
8. Lighting Systems Baselyte BSL23 Page 1 of 8 a 3 Light T8 Indirect x angled lamp Weight 3 0 Ib ft Ordering Information Family Distribution Lamp Type No of Lamps Housing Module Length Wiring Voltage Ballast Finish BSL 3 T fl 03 fl EN f 3 Indirect i T8 03 3 Light EN Solid la 4 1 I cct 120V k Standard C Custom Color 08 8 2 2cct 2 271V lt 20 THD W Standard 12 17 3 1cct w EC NL F Standard White 4 2cct w EC NL lt 20 THD 5 Icct w EM Battery w fusing 6 2cct w EM Battery G lt 10 THD 7 1cct w Dimming Instant Start 8 Icct w 1cct H lt 10 THD Thru wire Instant Start 9 2cct w 1cct w fusing Thru wire J lt 10 THD Note Please consult Program Start K lt 10 THD Specifications Features 1 Housing die formed 20ga cold rolled steel End Set die cast metal with baked powder coat finish Lamping three T8 lamps Configuration 4 8 and 12 module lengths or continuous rows Ballasts electronic 120V or 277V oF wh Finish High quality white powder coat with textured matte finish Custom colors available Consult factory Mounting Aircraft cable gripper is tamper resistant and provides infinite vertical adjustment capability Aircraft cable crimp and cable gripper independently tested to meet stringent safety requirements Electrical All luminaires are factory p
9. fy DEG 0 225 45 675 9 80 2131 2131 2131 2131 2131 g 75 2119 2122 2130 2136 2138 A 65 2042 2060 2105 2135 2149 0 2 55 1899 1942 2041 2117 2146 d 45 1692 1771 1942 2048 2086 3 cg 35 1430 1566 1784 1899 1940 4 25 1119 1325 1555 1634 1678 5 i 15 776 1026 1220 1243 1281 6 l 05 413 632 751 695 734 7 a 95 93 128 202 152 193 8 oe 90 3 3 15 4 13 3 77 s 85 0 0 0 0 0 10 i 75 0 0 0 0 0 2200 a 65 0 0 0 0 0 i 2 55 0 0 0 0 0 45 0 0 0 0 0 Report No 2101587 35 0 0 0 0 0 Zonal Lumen Summary Lamps F32T8 25 0 0 0 0 0 ZONE LUMENS BARE LAMP LUMINAIRE Lumens per Lamp 2950 15 0 0 0 0 0 0 90 0 0 0 Efficiency 85 7 5 0 0 0 0 0 90 180 7588 85 7 100 0 Up 100 0 Down 0 0 0 0 0 0 0 0 0 180 7588 85 7 100 0 Module Lengths amp Mounting Distances Run Configuration Run 7 8 Ve Joiner EndSet Mount Power Module Length Length Module Module Module Mount Mounting Distance 4 run 1 1 1 8 run 1 1 1 lt 8 gt 12 run 1 1 1 Module Length Mounting Distance 16 nun A 1 1 2 20 run 1 1 1 1 2 12 24 run 2 1 1 2 lt gt Module Length Mounting Distance 28 run 2 1 2 1 3 32 run 1 2 2 1 3 Note Shaded area indicates locations of emergency sections emergency wiring Note Additional power mounts may be required for some runs with T5 HO controls all lamps or optional battery pack controls one or two lamps
10. ng alternate 4 sections C type B 2cct 4 Q a 2 ie 1 O Type A 2cct w 1cct thru wire 4 Q F4 2 rt Q F O Type S 2cct w 2cct thru wire a Q rja 2 ra Q Fixture wired for two circuit Lamps wired for A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections with Emergency Circuit Night Light EC NL L Type C 2cct w EC NL P o ra r a m 4 Q 4 2 SEANSS ECN N F 4 Q Uae 2 BEN Y EC NL k One 4 section in a two circuit fixture A B switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to fixture ends All lamps in EC NL section to be wired together 2 Circuit A B Switching alternate 4 sections with Emergency Battery Pack EM L Type D Chloride standard 1 o rla rla o 5 C700A 4 1 a O Eas S1 EM N k C Type O Bodine standard 4 Q j 2 ejat Q k B70A Fixture wired for two circuits A B switching plus a battery pack is wired to one lamp A hot lead O Type G Chloride high performance is connected to the battery pack and would act as a trigger wire when connected to a constant hot C1400 by installer Leads for both normal circuit and battery pack are wired to fixture ends L Type R Bodine high performance Note Multi lamp battery packs are also available B50 2 Circuit A B Switching alternate 4 sections wi
11. re wired to module ends with quick wire connectors Joints amp Intersections Self aligning joining system with hands free pre joining wire access Labels UL CSA standards wiring section of spec sheets for more wiring options Program Start w fusing Ordering Instructions Individual Fixtures 1 Determine the number of individual modules required 2 Order one end set per module 3 Order one non power mount per module 4 Order one power mount per module Continuous Rows 1 Determine run length Order the appropriate number and length of modules for complete run Order one end set for each run Order one non power mount for each module Order one power mount per run Order one joiner per module minus one e g 3 modules requires 2 joiners moo wh Note Some runs may require additional power mounts Please see the Run Configuration table on next page for more details Job Information Job Name Cat No Lamp s Notes Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 WIOLFSOM l Lighting Systems Baselyte BSL23 Page 2 of 8 3 Light T8 Indirect Performance Candlepower Curve Candlepower Summary Coefficients of Utilization Oo a y ZONE CANDLEPOWER EFFECTIVE CEILING CAVITY REFLECTANCE
12. ry packs are also available WIOLFSOM Job Information iT Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 l Lighting Systems Baselyte BSL23 Page 7 of 8 3 Light T8 Indirect Wiring Options 2 Circuit Center Outer Switching 2 Circuit Center Outer Switching Ll Type 2 2cct 4 O p O ra 2 F L Type 9 2cct w 1ccet thru wire 4 Q E Q ra Q I O Type I 2cct w 2cct thru wire ia Ea 2 iE a Fixture wired for two circuit Lamps wired for center outer switching 2 Circuit Center Outer Switching with Emergency Circuit Night Light EC NL O Type 4 2cct w EC NL 4 rla mp SEC NLS 7 4 Q a oO E STIRS a 2 a 2 F A SI SSE One 4 section in two circuit fixture center outer switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to fixture ends All lamps in EC NL section to be wired together 2 Circuit Center Outer Switching with Emergency Battery Pack EM LJ Type 6 Chloride standard 4 O a 2 E 2 k C700A 4 0 rla Q E ADO L Type N Bodine standard 4 O O rt Q F B70A Fixture wired for two circuits center outer switching plus a battery pack is wired to one lamp
13. th Emergency Circuit Night Light and Emergency Battery Pack L Type L Chloride standard C700A 4 1 a 2 ENNY EC NL EM NANNU One 4 section in a two circuit fixture A B switching to be wired on a separate thru circuit in addition a battery pack is wired to one lamp Installer can connect trigger wire to EC hot lead if controlled together or wired separately if controlled independently Leads for normal circuit EC NL circuit and battery pack are wired to fixture ends All lamps in EC NL section to be wired together Note Multi lamp battery packs are also available HIQOLAHSEII E r Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 l
14. upplied by others e Fully vertically adjustable at fixture e Adjusts to both 1 and 1 1 2 high T bar systems 3 Conductor 4 Conductor 7 Conductor 2 Power Mount 3 Conductor Note Supports 15 16 9 16 and slot grid ceiling types Non Power Mount Mount Type Support or Open Joist Ceiling 1 Power Mount 3 Conductor 4 Conductor Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 stranded aircraft cable Versatile mount fully adjustable to accomodate open sloped ceilings J Box 4 octogonal box supplied by others Fully vertically adjustable at fixture 7 Conductor 2 Power Mount 3 Conductor Non Power Mount 3 Light T8 Indirect 2 Power Mount Non Power Mount p Supension Length z g 8 12 BSLM2108P13 BSLM2112P13 1 Power Mount BSLM2102P13 BSLM2104P13 BSLM2102P14 BSLM2104P14 BSLM2108P14 BSLM2112P14 BSLM2102P23 BSLM2104P23 BSLM2108P23 BSLM2112P23 BSLM2102N BSLM2104N BSLM2108N BSLM2112N 2 Power Mount Non Power Mount P Supension Length 1 Power Mount z g 8 12 BSLM5102P13 BSLM5104P13 BSLM5108P13 BSLM5112P13 BSLM5102P14 BSLM5104P14 BSLM5108P14 BSLM5112P14 BSLM5102P17 BSLM5104P17 BSLM5108P17 BSLM5112P17 BSLM5102P23 BSLM5104P23 BSLM5108P23 BSLM5112P23 BSLM5112N BSLM5102N
Download Pdf Manuals
Related Search
Related Contents
TDN 取扱説明書制作お見積りに関して Art Decor HAA6515-S Instructions / Assembly Handbuch zur Serverkonfiguration für ESX Server 3 Toshiba 3520C All in One Printer User Manual Hasselblad 848 User's Manual Finding and Inputting Data into EnergyPLAN ATTENTION! ATTENTION! 取扱説明書 PHOTOMOD GeoCalculator Philips AJ3740/00S User's Manual Copyright © All rights reserved.
Failed to retrieve file