Home

Lightolier IS:7586 User's Manual

image

Contents

1. READ AND UNDERSTAND ALL TRACK CONNECTOR FEED IN KITS AND ACCESSORY INSTRUCTION SHEET NO INSTRUCTION SHEETS BEFORE INSTALLING ANY TRACK ITEM This fixture is intended for installation in accordance with the National Electrical Code and local or Federal S E 7 586 code specifications To assure full compliance with codes and regulations check with your local electrical C inspector before installation To prevent electric shock turn off electricity at fuse box before proceeding B1197 Page 1 of 2 Retain these instructions for maintenance reference Installation Instructions for Stem Mounting Kit for use with Lytespan and ProSpec Track Systems Only Caution Turn off power at fuse box before installing track Instructions for grounding must be followed Failure to do so may result in a hazardous condition Use only 12 ga solid copper wire in connectors to maintain proper track rating Do not supply Advent Track from two separate 120V branch circuits as this could overload the neutral track conductor leading to an electrical safety hazard Observe polarity white neutral wire must be connected to terminal marked NEUT Failure to observe Polarity may result in an electrical hazard Stem mounting kits 18 or 48 long may be attached to the track at any point and may be spaced up to 4 apart They may be used to feed Outlet Box power into the track The unthreaded end of a stem may be field cut using a hacksaw or a sim
2. ds through Stem used for power feed insert Stems into Stem Mounting Plates and tighten Set Screws Thread Screw Collars onto Stem Mounting Plates See Fig 1 and 2 Canopy Bottom Cover Track Clamp cS i TOI i E R FALL RIVER MASSACHUSETTS 02720 i MONTREAL QUEBEC CANADA ES INSTRUCTION SHEET NO 1S 7586 B1197 Page 2 of 2 MOUNTING TRACK ONTO STEMS Loosen Screws on Track Clamps In the stem used for power feed the Track Clamps must be positioned as shown in Fig 2 Place Track Ribs Fig 4 between Track Clamps and side track into position Make sure Bead Basic and Advent only Fig 4 of Track Units are in line with one another Run Supply Leads along top of track toward Live End Loosen screw in Live End and remove from track Cut Wireway Cover to distance from Track Clamp to end of Track Unit Slide Wireway Cover into track over Supply Leads Fig 2 and 4 For ProSpec Feed track place wire cover into track before attaching the stems to the track unit Remove Bottom Cover from Live End Break off Barrier in Live End by bending it back and forth Fig 3 Pass Supply Leads through barrier opening in Live End Insert Live End into Track Unit and tighten Screws Fig 2 and 3 Connect Supply Leads to screw terminals as shown in Instruction Sheet IS 6020 1S 6121 for Advent or 1S 26000 S 26046 IS 26050 for ProSpec Ground terminal in Live End is not used when f
3. eeding power from a Stem Fasten Bottom Cover to Live End Tighten Screws on all Track Clamps Instructions for Stem Extension Kit Screw Coupling to threaded end of Stem 18 or 48 long supplied with Stem Mounting Kit fig 5 Screw Stem supplied with Stem Extension Kit to Coupling Fig 5 Complete installation of Stem Mounted Lytespan Track following steps in section A and B Installation Instructions for Stem Mounting Kit for use with Lytespan and ProSpec Track Systems Only Basic Track Sidewall Track Rib Wireway Cover as Individual Track Unit Bead ProSpec Track Fig 4 Stem Mounting Plate Set Screws Canopy Screw Collar Stem Stem Mounting Kit Screws _ Track Clamps Supply Leads Fig 4
4. ilar cutting device The Stem Extension Kits Ground Wire 2K Stem Mounting Plater 48 is used to lengthen a stem 48 The Stem Extension Kit cannot be field cut Ground Screw KEIT Pa Groung Spri Instructions show the Stem Mounting Kit being installed on Basic ies ee Track providing power feed to a Live End The same instructions apply to power feed to an Advent Live End Basic Advent ProSpec In Line L T X or Variable Angle connector and ProSpec Feed Track Serew Collar For Basic X and T connectors the neutral terminal is the lower terminal which lines up with the bead in the track see Instruction Sheet 1S 6165 A MOUNTING STEMS TO CEILING 1 Power feed Stem must be stem adjacent to fees in point of track Wires cannot pass beneath two stems 2 Splice Supply Leads 12 AWG solid TW wire not included to branch circuit leads in Outlet Box white to white black to black red to red in Advent Supply Leads must be long enough to run horizontally along the track to the track feed in point Pass Supply Leads through Stem Mounting Plate and connect 12 AWG Ground Wire to Ground Screw on the Stem Mounting Plate Fasten Stem Mounting Plate to Outlet Box Mount other Stem e Mounting Plate s to ceiling in a straight line Space not more than Broken Off 4 apart See Fig 1 Assemble Track Clamps as shown in Fig 1 Screw Track Clamps onto Stems and slip Screw Collars and Canopies onto Stems Pass Supply Lea

Download Pdf Manuals

image

Related Search

Related Contents

Lenovo ThinkPad 44C9770 User's Manual  Samsung 藍光播放器 BD-F5100 用戶手冊  Service Manual  Untitled  MU1202 / MU1202X  Philips 50PFP5332D 50" plasma integrated digital widescreen flat TV  KOIMOS – Aceite natural nº 196  

Copyright © All rights reserved.
Failed to retrieve file