Liebert GXT96VLRT2UL User's Manual

image

Contents

1. hex bolts from the side of the shipping crate Retain one hex bolt and the side of the shipping crate 4 Remove the four wood planks from each corner of the shipping crate Remove the top of the shipping crate from the LRT cabinet 5 Place the side of the shipping crate at the bottom of the crate and insert one hex bolt in the crate bottom The LRT cabinet can now be rolled off of the shipping crate 6 Visually inspect the LRT cabinet for freight damage Report damage to the carrier and your dealer 7 Locate the LRT cabinet indoors in a controlled environment where it cannot be accidentally disconnected Locate it in an area with unrestricted air flow away from water flammable liquids gases corrosives or conductive contaminants Maintain a minimum of 4 inches 100 mm clearance in front and rear of the LRT cabinet Battery cabinets are designed to be placed on either side of or beneath the UPS Maintain an ambient temperature range of 32 to 104 F 0 to 40 C NOTE LRT cabinet operation in temperatures above 77 F 25 C reduces battery life 8 Plug the LRT cabinet into a dedicated wall receptacle properly protected by a circuit breaker or fuse in accordance with the National and Local Codes Use a 15 amp rated device for 120VAC applications or a 10 amp rated device for 230VAC applications The wall receptacle must be grounded and should be wired so as to experience outages simultaneously with the connected UPStation GX
2. the enclosed Long Run Time Battery Cabinet LRT and components are free from defects in materials and workmanship under normal use service and maintenance FOR A PERIOD OF TWO YEARS FROM THE DATE OF ORIGINAL PURCHASE from Liebert or the Liebert dealer or retailer THE FOREGOING WARRANTY IS THE ONLY WARRANTY GIVEN AND NO OTHER WARANTY IS PROVIDED EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Certain aspects of disclaimers are not applicable to consumer products acquired by individuals and used for personal family or household purposes as distinguished from industrial or other purposes Local laws may not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary according to local law Certain repairs or services are the responsibility of the Purchaser and the Purchaser is expected to pay for them This warranty does not extend either to products with removed or altered serial numbers or to any losses or damages due to act of God or source external to the product misuse accident abuse neglect negligence unauthorized modification alteration or repair use beyond rated capacity or improper installation maintenance application or use including without limitation use in a manner contrary to the accompanying instructions or applicable codes WARNING
3. Warranty is void if the battery is allowed to discharge below the minimum battery cutoff point To prevent such discharge DO NOT leave the unit power switch ON for more than two 2 days without AC power being supplied to the LRT The battery must be recharged every four 4 to six 6 months when not in use If the LRT fails to conform with the above warranty within the two year warranty period Liebert will repair or replace the LRT at Liebert s option Repairs or replacements are warranted for the remainder of the original warranty period Purchaser to make a warranty claim should call 1 800 222 5877 to obtain a Returned Goods Authorization number and shipping instructions Return transportation costs to Liebert are the responsibility of the Purchaser This product is not recommended and the Company will not knowingly sell this product for use with life support and other designated critical devices ANY SUCH USE BY A USER AUTOMATICALLY VOIDS AND DISCLAIMS ANY AND ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND EXPRESS WARRANTIES THAT THIS PRODUCT WILL CONFORM TO ANY AFFIRMATION OR PROMISE FOR THIS PRODUCT AND THE USER AGREES THAT IN NO EVENT SHALL THE COMPANY BE LIABLE FOR CONSEQUENTIAL OR INDIRECT DAMAGES DISCONTINUED PRODUCT UPStation GXT LRT Battery Cabinet for use with the 1800 3000 VA UPS Units Technical Support U
4. DISCONTINUED PRODUCT iebert UPStation GXT LRT Battery Cabinet for use with the 1800 3000 VA UPS Units USER MANUAL English Espanol IMPORTANT SAFETY INSTRUCTIONS WARNING Do not attempt to service this product yourself Opening or removing the cover may expose you to dangerous voltages even when the AC cord is disconnected from the electrical outlet Refer all servicing to qualified service personnel 1 SAVE THESE INSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT INSTRUCTIONS THAT SHOULD BE FOLLOWED DURING INSTALLATION AND MAINTENANCE OF THE BATTERY CABINET AND UNINTERRUPTIBLE POWER SYSTEM UPS 2 This product is not intended for use with life support and other U S FDA designated critical devices See Limited Warranty 3 CAUTION A BATTERY PRESENTS A RISK OF ELECTRICAL SHOCK OR BURN FROM HIGH SHORT CIRCUIT CURRENT OBSERVE PROPER PRECAUTIONS 4 WHEN REPLACING THE BATTERIES USE THE SAME NUMBER AND TYPE OF BATTERIES PROPER DISPOSAL OF BATTERIES IS REQUIRED REFER TO YOUR LOCAL CODES FOR DISPOSAL REQUIREMENTS 5 Read all safety and operating instructions before operating the UPS and battery cabinet Adhere to all warnings on the unit and in this manual Follow all operating and user instructions 6 Turn the UPS and battery cabinet off and unplug them before cleaning Use only a soft cloth never liquid or aerosol cleaners 7 The UPS is designed for data processing equipment Do not plug appliances
5. S A Outside the U S A U K France Germany Italy Netherlands E mail Web site Worldwide FAX tech support The Company Behind The Products With more than 500 000 installations around the globe Liebert is the world leader in computer protection systems Since its founding in 1965 Liebert has developed a complete range of support and protection systems for sensitive electronics Environmental systems close control air conditioning from 1 5 to 60 tons Power conditioning and UPS with power ranges from 250 VA to more than 1000 kVA Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control on site or remote from systems of any size or location Service and support through more than 100 service centers around the world and a 24 hour Customer Response Center 1 800 222 5877 614 841 6755 44 0 1793 553355 33 0 1 4 87 51 52 49 89 99 19 220 39 2 98250 1 31 0 475 503333 upstech liebert com http www liebert com 614 841 5471 While every precaution has been taken to ensure accuracy and completeness in this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 1999 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice Liebert and the Liebert logo ar
6. T UPS CAUTION Do not use the UPS output receptacles as the LRT input power Source 9 Connect the supplied cable to the battery cabinet then to the UPS Turn on the charger by pressing the On switch located on the rear panel Turn on the breaker on the rear of the battery cabinet The LRT cabinet is ready for normal operation Up to three optional LRT cabinets may be connected to the UPS to provide additional run time DISCONTINUED PRODUCT GXT LRT Installation Battery Interconnect Ports 7 DG Output Breaker x On Off AC Input AC Input Fuse eeececcecc0e0 990000909009 8060000000 9060000000008 20000000000 00000000000 9e0e0000000008 900909009 DISCONTINUED PRODUCT CONTROLS AND INDICATORS On Off Switch This switch controls charger output The switch is located on the rear of the unit and must be in the Up position to enable the charger Circuit Breaker Switch This breaker is located on the rear of the unit and must be closed to allow the LRT Battery Cabinet to supply additional DC power to the UPS in the event of an interruption in commercial power The switch must be in the O
7. e registered trademarks of Liebert Corporation All names referred to are trademarks or registered trademarks of their respective owners SL 23455 5 99 Rev 1 g un AO o9 2 E n
8. ledgeable of batteries and the required precautions Refer all servicing to qualified service personnel 13 CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic 14 CAUTION This equipment has been tested and complies with limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC rules and the CE directive These limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference that the user must correct at their own expense 15 This equipment can be operated by individuals without previous training DISCONTINUED PRODUCT Unpacking the LRT V EN vun NV DISCONTINUED PRODUCT GENERAL INSTALLATION LRT CABINET INSTALLATIONS 1 CAUTION The LRT cabinet is heavy see specifications Take proper precautions when lifting or moving it 2 Remove the retaining straps and protective cardboard covering from the shipping package 3 Remove the 14mm 9 16
9. n position to close the breaker Power Indicator Green The Power indicator is located on the rear of the unit and is illuminated when the LRT Battery Cabinet is receiving commercial power and the internal charger is operating Summary Alarm Red The Alarm indicator is located on the rear of the unit and is illuminated if the LRT Battery Cabinet has detected a problem In addition one or more of the UPS load battery level indicators may be illuminated refer to the UPS Troubleshooting Guide MAINTENANCE The LRT Battery Cabinet requires very little maintenance The batteries are valve regulated nonspillable lead acid and should be kept charged to obtain their designed life Periodically examine the vents on the front and rear of the cabinet and remove any obstructions from the surface of the vents When storing the LRT Battery Cabinet for any length of time it is recommended to recharge the LRT Battery Cabinet for at least 24 hours every four to six months to increase battery life In no case should the unit be stored in excess of nine months without recharge DISCONTINUED PRODUCT LRT Battery Cabinet Specifications Model Number GXT96VLRT2UL Compatible With 1800RT 208 2000RT 120 2000RT 230 2700RT 208 UPStation GXT 3000RT 120 and 3000RT 230 VA UPS Unit W x Dx H WEIGHT Ibs kg Unit 600 Ibs 272kg INPUT AC PARAMETERS Voltage Range 85 to 265VAC Frequency gt 40 to lt 0 Hz auto sensing Input Power Fact
10. or gt 0 95 Current Reflected THD 30 THD maximum Current Rating lt 4A at 120VAC lt 2A at 230VAC Input Power Connection IEC320 C14 recessed plug with input cords 1 cord with NEMA 5 15P Fuse Rating 6 3A OUTPUT DC PARAMETERS Output Sockets 2 per LRT cabinet Interconnect Cable 1 9 8 3m cable with appropriately keyed plugs Protection 1 resettable DC circuit breaker BATTERY PARAMETERS Type Valve regulated nonspillable lead acid Quantity x Voltage x 8 x 12V x 65 0Ah Rating Approved Battery Manufacturers Recharge Time lt 20 Hours to 95 capacity after full discharge into 100 load ENVIRONMENTAL Operating Temperature 32 F to 104 F 0 C to 40 C for altitudes to 5 000 ft 1 500m 32 F to 95 F 0 C to 35 C for altitudes 5 000 ft 1 500m to 10 000 ft 3 000m Storage Temperature Relative Humidit 0 to 95 non condensing Audible Noise Safety Surge IEEE 587 Category A EN61000 4 5 Level 3 L E Level 2 L L 15 x 27 x 29 381 x 686 x 737 CSB Panasonic and Yuasa ESD Susceptibilit Transient Burst EMI EMC FCC Part15 Class A EN50081 1 EN 55022 Class B Immunity EN50082 1 Additional information on this product can be located on our web site www liebert com or FastBak server 614 841 5471 DISCONTINUED PRODUCT LIMITED WARRANTY Liebert Corporation extends the following LIMITED WARRANTY to the purchaser and to its customer collectively referred to as the Purchaser
11. such as hair dryers heaters vacuum cleaners or electric drills into the UPS output receptacles The UPStation GXT LRT has a nominal voltage rating of 96VDC The UPStation GXT M LRT is designed to operate only with the Liebert UPStation GXT 1800 2000 and 2700 3000 VA rack tower RT UPS units with a sequential serial number 9915003001AF1T1 or greater The LRT cabinets are capable of being paralleled in order to achieve longer run times up to 8 hours 8 WARNING Do not modify input cable Consult your dealer if connector does not match the utility receptacle The UPS and Battery Cabinet must be grounded at all times while in use Turn the UPS and Battery Cabinet off before unplugging them or the safety ground will be removed Operate Battery Cabinet only from a properly grounded 120 or 230 VAC outlet 2 wire plus ground 9 The Battery Cabinet is equipped with a grounded NEMA 5 15 or a grounded Schuko type input power plug depending upon input voltage Do not defeat the safety purpose of this plug If unable to fully insert the plug into the wall outlet contact a qualified electrician for assistance 10 Route power supply cords so they are not walked on or pinched 11 Never block or insert any object into the ventilation holes or other openings Maintain a clearance of four 4 inches in front and rear of the Battery Cabinet for proper airflow and cooling 12 Servicing of batteries should be performed or supervised by personnel know