1. Interface connector RJ48C Line rate DS1 includes CSU 1 544 Mbps per port DSX 1 1 544 Mbps per port E1 2 048 Mbps per port Channelization NxDSO up to full line rate QUAD DSX 1 E1 PHYSICAL LAYER MODULE Interface connector DA15 Line rate DSX 1 1 544 Mbps per port E1 2 048 Mbps per port Fractionalization NxDSO up to full line rate QUAD V 35 EIA 530 PHYSICAL LAYER MODULE Interface connector DB25 Electrical V 35 RS449 EIA 530 X 21 Line speed 64 Kbps to 2 048 Mbps on each of four ports or up to 8 192 Mbps on one port HSSI PHYSICAL LAYER MODULE Interface connector TIA EIA 613 standard 50 position Line speed 1 Mbps to 52 Mbps Continued on next page www kentrox com 8 800 733 5511 AAC 3 AAC 2 and CellISMART Select Physical Layer Modules continued DS3 AND E3 PHYSICAL LAYER MODULES Interface connector 75 ohm coaxial BNC Line rate DS3 44 736 Mbps E3 34 386 Mbps OC 3C STM1 SINGLE AND MULTI MODE PHYSICAL LAYER MODULES Interface connector Duplex SC Line speed 155 52 Mbps Wavelength 1310 nm single mode or multi mode QUAD ETHERNET PHYSICAL LAYER MODULE Data rates 10 Mbps per port half duplex Number of ports 4 Interface connectors RJ4 Ordering Information Description Catalog Number Chassis and Power Supplies AAC 3 Eight Slot Chassis 10000 AAC 3 DC Power Supply 10101 AAC 3 AC 120 Volt Power Supply 10100 AAC 3 AC 240 Volt Power Supply 10102 AAC 3 AC 120 240 Volt
2. Power Supply 10103 AAC 2 Four Slot Chassis 10001 AAC 2 DC Power Supply 10111 AAC 2 AC 120 Volt Power Supply 10110 AAC 2 AC 240 Volt Power Supply 10112 AAC 2 AC 120 240 Volt Power Supply 10113 Common Modules AAC Alarm Module 10011 AAC Service Data Module SDM 10013 AAC Integrated System Controller with 3 2 0 software 10022 320 Protocol Modules AAC Cell Protocol Module 10200 AAC Packet Protocol Module 10201 AAC Quad Cell Protocol Module 10202 AAC Quad Packet CBR Protocol Module 10203 AAC Enhanced Shaping Cell Protocol Module 10204 AAC Quad Packet Protocol Module 10205 AAC Quad Ethernet Protocol Module 10206 AAC Octal CES CBR Protocol Module 10207 www kentrox com 9 800 733 5511 AAC 3 AAC 2 and CellSMART Ordering Information Description Catalog Number Physical Layer Modules AAC DS3 Physical Layer Module 10300 AAC HSSI Physical Layer Module 10301 AAC Quad DSX 1 Physical Layer Module 10302 AAC Tri V 35 EIA 530 X 21 and one DSX 1 Physical Layer Module 10303 AAC OC3c STM1 MM Fiber Physical Layer Module 10304 AAC OC3c STM1 SM Fiber Physical Layer Module 10305 AAC E3 Physical Layer Module 10306 AAC Quad E1 Physical Layer Module 10307 AAC Tri V 35 EIA 530 X 21 and one E1 Physical Layer Module 10308 AAC Quad V 35 EIA 530 X 21 Physical Layer Module 10309 AAC J2 Physical Layer Module 10310 AAC Quad 10Base T Ethernet Physical Layer Module 10311 AAC Octal 8 port DSX 1 Physical Layer Module 10314
3. Video emnon _f p Network 7 AAC 2 with SDM Module Frame Relay on HSSI Figure 5 Providing SLA data by responding to FPING messages www kentrox com 5 800 733 5511 Round trip Delay End to end Delay Frame Delivery Ratio Data Delivery Ratio Frames Dropped Received and Transmitted ServicePoint SDU 1 0 F ServicePoint SDU Frame Relay Public Ti E a Network eas H bs SS ey DataSMART Frame Monitoring DSU CSU 00 00 00 AAC 3 AAC 2 and CellISMART Specifications AAC 3 CHASSIS Dimensions H x W x D 13 95 x 17 32 x 19 354 3 x 440 x 482 6 mm Weight 60 Ibs 27 kg Mounting Available for 19 inch or 23 inch standard equipment racks Operating Temperature 32 F to 104 F ambient 0 C to 40 C Operating Humidity 5 to 95 non condensing AAC 2 AND CELLSMART 200 CHASSIS Dimensions H x W x D 6 95 x 17 32 x 19 176 5 x 440 x 482 6 mm Weight 29 Ibs 13 2 kg Mounting Available for 19 inch or 23 inch standard equipment racks Operating Temperature 32 F to 104 F ambient 0 C to 40 C Operating Humidity 5 to 95 non condensing EMI ESD SAFETY EMI FCC Part 68 FCC Part 15 Class A EN55022 Class B Immunity EN55024 Safety UL1950 EN60950 CSA 22 2 No 950 M95 NEBS Level 3 certified SWITCHING BACKPLANE Cell bus Dynamic time allocated output buffered per port or connection Maximum system throughput 524 Mbps 1 168 000 ce
4. 210 or maximum cells Cell emission scheduling Per port for VBR traffic only or aggregate CBR and VBR traffic Congestion management Early packet discard EPD and 4 VBR priorities CBR not subject to congestion Partial Packet Discard PPD ENHANCED SHAPING CELL PROTOCOL MODULE Protocols supported ATM UNI Connections 256 VPCs 1023 VCCs or combinations of up to 1023 total connections 94 VPLs QoS categories CBR rt VBR nrt VBR UBR UBR Output queuing Total queue depth 128K cells allocated between VCCs and VPCs Cell emission scheduling Per VC for all connections nrt VBR UBR and UBR scheduled via a weighted fair queuing WFQ mechanism Congestion management Partial and early packet discard EPD implemented per VC QUAD CELL PROTOCOL MODULE Protocols supported ATM UNI SMDS SNI Connections 256 VPCs or 1024 VCCs or combinations of up to 1024 total connections QoS categories CBR nrt VBR and rt VBR Output queuing Separate CBR amp VBR output queues with traffic and congestion management capabilities Congestion management Early packet discard EPD and 4 VBR priorities CBR not subject to congestion Partial Packet Discard PPD PACKET PROTOCOL MODULE QUAD PACKET PROTOCOL MODULE Protocols supported Frame Relay ATM DXI HDLC PPP SMDS DXI Frame Relay connections Packet PM 2048 VCCs AALS or DLCls Quad Packet PM 512 VCCs AAL5 or DLCIs per port Services supported FRF 5 FRF 8 1490 to 1483 translation and FRLM Congest
5. 8 AAC CelISMART Installation Guide printed spare 5000549 AAC CelISMART User s Guide printed 5000550 Memory Cards with Software AAC ISC Back up Software Compact Flash Type 2 10038 320 AAC Octal IMA Firmware 2 0 0 Compact Flash Type 2 10036 200 Power Cords North America Korea Taiwan 90000 European Community 90001 United Kingdom 90002 Italy 90003 Australia 90004 Japan 90005 www kentrox com 11 800 733 5511 AAC 3 AAC 2 and CellISMART Multi service Access Concentrators Web Site www kentrox com Phone 503 643 1681 e Toll Free 800 733 5511 e Fax 503 350 6897 Kentrox LLC 20010 NW Tanasbourne Drive Hillsboro OR 97124 Kentrox AAC 3 CelISMART and DataSMART are registered trademarks of Kentrox LLC AAC AAC 2 FrameVision ServicePoint and ServicePoint Manager are trademarks of Kentrox LLC Visual Networks and Visual UpTime are registered trademarks of Visual Networks Technologies Inc All other products are trademarks of their respective owners Specifications published here are current as of the date of KE NTROX publication of this document At any time you may verify product specifications by contacting our headquarters in Hillsboro 05 06 015 2 2 03 2002 2003 by Kentrox LLC All Rights Reserved An Equal Opportunity Employer
6. AAC 3 AAC 2 and CelISMART Multi service Access Concentrators AAC Multi service Access Concentrators cost effectively connect voice video and data traffic to private Wide Area Networks and public ATM and Frame Relay services worldwide Supporting multiple protocols physical interfaces and a wide range of bandwidth requirements AAC and CellISMART products allow organizations and service providers to consolidate hybrid facilities for reduced costs and more efficient management of broadband networks KENTROX Features Scalable architecture provides flexibility as network requirements change Multi service access in a single device reduces recurring monthly access costs Large variety of available interfaces supply serial ports Frame Relay and T1 E1 NxT1 E1 IMA T3 E3 and OC 3 STM 1 to deliver specific services for customer applications Standards compliance with ATM Forum Telcordia NEBS Level 3 ITU T and Frame Relay Forum ensures multi vendor interoperability SNMP and Telnet allow manage ment from local and remote sites Comprehensive ATM WAN service management for monitoring ATM services a AAC 3 AAC 2 and CellSMART Description The AAC family offers a flexible modular architecture allowing you to choose the most cost effective service for each application and manage everything from a single platform Each AAC contains slots for Protocol Modules PM that determin
7. AAC Octal 8 port E1 Physical Layer Module 10315 AAC Octal 8 port DS1 CSU Physical Layer Module 10317 AAC Octal 8 port IMA DS1 Physical Layer Module FW 2 0 0 10318 200 AAC Octal 8 port IMA E1 Physical Layer Module FW 2 0 0 10319 200 CellSMART 200 ATM IMA Systems CelISMART 201t ISC DS1 Octal IMA to HSSI 120V AC 20001 310 CelISMART 201e ISC E1 Octal IMA to HSSI 240V AC 20002 310 CelISMART 202t ISC DS1 Octal IMA to V 35 6 Mbps 120V AC 20003 310 CelISMART 202e ISC E1 Octal IMA to V 35 8 Mbps 240V AC 20004 310 CelISMART 203t ISC DS1 Octal IMA to 10Base t 120V AC 20005 310 CelISMART 203e ISC E1 Octal IMA to 10Base t 240V AC 20006 310 CelISMART 204t ISC DS1 Octal IMA to OC 3c STM 1 120V AC 20007 310 CelISMART 204e ISC E1 Octal IMA to OC 3c STM 1 240V AC 20008 310 CelISMART 205t ISC DS1 Octal IMA to DS 3 120V AC 20009 310 CelISMART 205e ISC E1 Octal IMA to E3 240V AC 20010 310 www kentrox com 10 800 733 5511 AAC 3 AAC 2 and CellISMART Ordering Information Description Catalog Number Accessories AAC 3 Fan Tray Assembly Spare 10080 AAC 3 23 Rack Mount Brackets 10081001 AAC2 23 Rack Mount Brackets 10081010 AAC Blank Panel 1 Slot Spare 10082 AAC 3 Blank Panel Power Supply Spare 10084 AAC3 Cable Management Bar 10087 AAC2 Enhanced NEBS Baffle Kit 10088 AAC Manual Set CD Spare 10090 310 AAC CellISMART Planning Guide printed 500054
8. an embedded SNMP agent and standard and enterprise MIBs compatible with SNMP based management systems You can also Telnet to the devices via the Ethernet port on the Integrated System Controller or an in band ATM Frame Relay connection The native user interface is menu driven making port and connection configuration quick and easy Traffic Management You can maximize the utilization of expensive wide area bandwidth with AAC traffic management features The Enhanced Shaping Cell Protocol Module performs traffic shaping on a per VC and per VP basis ensuring that traffic meets the rates contracted with your carrier This prevents cell discard and retransmissions improving the overall use of available bandwidth Connections exit the module through a weighted fair queuing WFQ mechanism that ensures each connection gets scheduled bandwidth even in the presence of congestion The system uses early packet discard EPD to reduce congestion quickly and to maximize network utilization Other AAC modules increase bandwidth utilization by reallocating idle CBR bandwidth The Octal CES module monitors the CAS voice on off hook status and V 35 CBR handshake signals When a www kentrox com 4 800 733 5511 connection goes idle the system can terminate the cell stream so that the bandwidth can be used by other VBR connections Performance Monitoring AAC systems collect extensive statistics including port and cell utilization ce
9. ation backup Pluggable Type II compact flash Management access Ethernet port and DTE asynchronous port for dial up modem in addition to front panel port www kentrox com 6 800 733 5511 AAC 3 AAC 2 and CellISMART Common Modules continued ALARM MODULE Indicators Critical Major and Minor alarm indicators are viewable from the front Alarm ACO Automatic Cut Off button disables audible alarms Configuration backup Flash SERVICE DATA MODULE SDM System indicators Critical Major and Minor SDM Indicators SDM status and monitored traffic Alarm ACO Automatic Cut Off button disables audible alarms and ACO indicator Configuration backup 1 Mbyte non volatile configuration on memory controlled by ISC module Traffic monitoring Monitors up to 512 VCs Maximum monitoring throughput Monitors VCs with a maximum aggregate rate equivalent to bi directional DS3 with 200 byte packets Traffic greater than bi directional DS3 is subject to discard Select Protocol Modules See the PM PLM compatibility matrix on page 3 for available Protocol and Physical Layer Module combinations CELL PROTOCOL MODULE Protocols supported ATM UNI SMDS SNI Connections 256 VPCs 4096 VCCs or combinations thereof up to 4096 total connections QoS categories CBR nrt VBR and rt VBR Output queuing Separate CBR and VBR output queues with traffic and congestion management capability Total queue depth 4700 cells Maximum burst size 32 105
10. e the traffic tyoe ATM Frame Relay or Ethernet and Physical Layer Modules PLM that determine the physical interface The broad array of available Protocol and Physical Layer Modules meets the needs of a variety of customers including enterprise service provider government and military The AAC family comprises three models to deliver a full range of access options at a variety of price points gt The AAC 3 offers the highest levels of connectivity and scalability supporting speeds ranging from T1 E1 to OC 3c STM 1 Its modular chassis supports up to seven PM PLM pairs making it an ideal hubbing device for enterprise networks or a port fan out device for service distribution Central Site ATM LAN swin QD Public ATM service or Frame Relays gt The AAC 2 provides economical integration of services over public and private networks at speeds ranging from T1 E1 to OC 3c STM 1 Its smaller chassis supports up to three PM PLM pairs making it suitable for mid sized locations that need to connect voice video and data traffic to the WAN gt The CellSMART 200 IMA series is ideal for medium to high speed data applications that require NxT1 E1 access using Inverse Multiplexing for ATM IMA A variety of models are available with V 35 HSSI Ethernet T3 E3 or OC 3c STM 1 user ports The high port density and modular architecture lets each network grow and
11. ines into a single logical link operating at up to 16 Mbps The module uses a round robin algorithm to divide traffic evenly across multiple links Furthermore if one or more links fails the traffic is automatically redistributed among the remaining links providing redundancy in the network The AAC family also offers numerous options for each protocol For ATM UNI both the Cell Protocol Module PM and the Enhanced Shaping Cell PM are available The Cell PM is optimized for full throughput on high speed private networks and local router or switch interfaces The Enhanced Shaping Cell PM is designed for use with public ATM services shaping each connection to ensure the traffic complies with carrier service level agreements Multiple PMs are available for Frame Relay services ATM DXI PPP and HDLC packet traffic The Quad Packet and Quad Packet CBR PMs support packet traffic over T1 E1 and low speed V 35 The Packet PM supports packet traffic over T3 E3 HSSI and high speed V 35 All PMs support Frame Relay Link Management and Frame Relay to ATM Service Interworking FRF 8 and Network Interworking FRF 5 For circuit emulation there are four or eight ports of structured or unstructured data transfer options The Quad Packet CBR PM supports up to four ports of unstructured circuit emulation on T1 E1 or V 35 The Octal CES PM supports up to eight ports of structured or unstructured T1 E1 up to four ports of unstructured V 35 or
12. ion management Partial and early packet discard EPD and 4 VBR priorities www kentrox com 7 800 733 5511 AAC 3 AAC 2 and CellSMART Select Protocol Modules continued OCTAL CES PROTOCOL MODULE Protocols supported Structured or unstructured circuit emulation over AAL1 Dynamic bandwidth allocation based on CAS signaling idle code detection or V 35 control signals Connections 32 unicast or multicast per port 256 per module Output queuing User selectable depth of CDV absorption queue to 1 ms Clocking Synchronous or asynchronous Adaptive Logical bundles 1 DSO to 24 DSOs T1 or 31 DSOs E1 QUAD ETHERNET PROTOCOL MODULE Bridging performance Filtering and forwarding rate 14 880 pps each direction each port half duplex Address table 4096 addresses per module 1024 static entries per AAC system Spanning Tree protocol Per IEEE 802 1 D LLC Encapsulation Using AAL 5 per RFC 1483 Select Physical Layer Modules See the PM PLM compatibility matrix on page 3 for available Protocol and Physical Layer Module combinations OCTAL IMA DS1 AND E1 PHYSICAL LAYER MODULES Interface connector RJ48C Line rate T1 1 544 Mbps per port E1 2 048 Mbps per port IMA rate T1 1 536 to 12 288 Mbps E1 1 984 to 15 872 Mbps Differential delay Up to 200 ms ACP sync cells User selectable at 32 64 128 or 256 cells Link adjustment Automatic adjustment on link failure or recovery OCTAL DS1 DSX 1 AND E1 PHYSICAL LAYER MODULES
13. ll and packet discard and physical line errors You can view the information in table or graphical form With this information you can monitor network performance anticipate growth in bandwidth requirements and trouble shoot problems in both the local and wide area networks The products also support a full range of loopbacks including line local and payload In OC 3 STM 1 networks you can insert BIP and AIS errors to test sections of that link Standards Compliance AAC products comply with the relevant standards of the ATM Forum ITU T Bellcore Telcordia the Frame Relay Forum and the SMDS Interest Group This alleviates compatibility issues in multi vendor networks and reduces the risks associated with pro prietary solutions ATM Forum specification compliance includes ATM UNI 3 0 and 3 1 Traffic Management 4 0 with support for CBR rt VBR nrt VBR and UBR QoS categories Circuit Emulation Services 2 0 with support for structured or unstructured CES and Inverse Multiplexing for ATM IMA 1 1 1 0 AAC 3 AAC 2 and CellISMART AAC Service Data Module SDM Supports ATM Managed Services The Service Data Module for the AAC acts as a Visual Networks Analysis Service Element e ASE Specifically designed to support NxT1 E1 IMA or DS3 E3 ATM networks it monitors user specified ATM ports and circuits and communicates service performance data and events to Visual UpTime s Kentrox and Visual Networks enable
14. lls second Connections 8192 VCCs 512 VPCs 512 Multicast POWER SYSTEM AAC 3 Dual redundant power system Modular power supplies field replaceable with unit powered Monitored with alarms traps on failure Forced air cooled Supports mixed use of AC DC power modules AAC 2 and CellSMART 200 Single power system Modular power supply Monitored with alarms traps on failure Forced air cooled Supports use of AC DC power modules AC power supply modules 120 240 VAC 85 to 264 volts 50 60Hz 3Hz DC power supply modules 48 VDC 42 to 60 VDC MANAGEMENT ACCESS Control port VT100 via RS232 port on front panel Additional RS232 port on the Integrated System Controller Ethernet port SNMP or Telnet In band SNMP or Telnet Telnet sessions Up to 4 concurrently with the Integrated System Controller Common Modules INTEGRATED SYSTEM CONTROLLER ISC Clock sources Internal reference oscillator or recovered from user specified physical port Clock fallback User selectable primary and secondary clock source with automatic fallback and recovery Internal reference Oscillator Stratum 4 or better Power loss protection Loss of all input line power will not affect the configuration settings performance data will be maintained for 12 hours upon loss of power Alarm Critical Major and Minor alarm indicators are viewable from the rear Contact closure for audible and visual alarms ACO Automatic Cut Off button disables audible alarms Configur
15. one port of unstructured T3 E3 or HSSI The Octal CES PM also supports an Adaptive Timing option The Ethernet PM and PLM pair supports RFC 1483 AAL5 bridging with the Spanning Tree Protocol The modules are designed for full speed point to point Ethernet connections over ATM 10200 10202 DS3 PLM 10300 10204 10207 10201 10205 10203 10206 HSSI PLM 10301 Quad DSX 1 PLM 10302 Tri V 35 530 amp DSX PLM 10303 OC 3c STM1 MM PLM 10304 OC 3c STM1 SM PLM 10305 E3 PLM 10306 Quad E1 PLM 10307 Tri V 35 530 amp E1 PLM 10308 Quad V 35 530 PLM 10309 J2 PLM 10310 Quad Ethernet PLM 10311 Octal DSX 1 PLM 10314 Octal E1 PLM 10315 Octal DS1 PLM 10317 Octal DS1 IMA PLM 10318 Octal E1 IMA PLM 10319 Figure 2 AAC PM PLM compatibility matrix www kentrox com 3 800 733 5511 AAC 3 AAC 2 and CellSMART ATM UNI ATM DXI e e e Frame Relay HDLC or PPP e e SMDS DXI e SMDS SNI e G Ethernet CBR CES G e G e Figure 3 The AAC family supports numerous user and network interfaces Element Management The AAC family supports local and remote access via in band or out of band connections All products include
16. service providers to introduce WAN Performance Management Services based on industry proven Ps hardware and software solutions Service providers can offer customers a variety of new managed service options and a higher degree of flexibility for hybrid ATM Frame Relay networks AAC 2 with SDM Module Frame Relay K on HSSI Pa ATM IMA ATM Public Network AAC 2 with SDM Module 1 1 i i Frame Relay K r on HSSI Po 1 1 eee re et ea ed Be all ATM onDS3 1 Figure 4 AAC acting as an ASE for Visual UpTime Frame Relay Monitors up to 512 VCs Monitors ATM traffic on user specified ports and VCs up to a maximum aggregate rate equivalent to a bi directional DS3 Provides data for Visual UpTime Event Processor Troubleshooting and Planning and Reporting tool sets Provides valuable bandwidth utilization details with protocol analysis and top host statistics Sends SNMP traps regarding AAC events to Visual UpTime Ti Public Network T1 Z Ti SLA Monitoring The Service Data Module for the AAC can be configured to supply Frame Relay Service Level Agreement SLA measurements to Kentrox ServicePoint and FrameVision devices in ATM and Frame Relay mixed networks The AAC responds to Frame PING messages FPING sent by ServicePoint and FrameVision devices delivering the following gat 5 CBR on i Sa ATM Publi
17. upgrade at a minimal cost As service or application needs change customers just add or switch modules while maintaining a common chassis and management interface For instance using an Octal IMA Physical Layer Module you can steadily add T1 E1 circuits as your bandwidth needs increase When eight T1 or E1 lines become insufficient you can switch to a T3 E3 Physical Layer Module You do not need to replace the Protocol Module because it can now be paired with the new T3 E3 Physical Layer Module Branch Office iB Sate ee Se eee he eee ee ee el S HSSI CellSMART 200 Router Figure 1 The AAC family of multi service access concentrators connects central branch and remote locations via public ATM or Frame Relay services www kentrox com 2 800 733 5511 AAC 3 AAC 2 and CellISMART Applications The wide array of Physical Layer Modules and Protocol Modules supports old and new applications alike On the user side legacy interfaces such as V 35 EIA 530 Packet and T1 E1 CBR protect your investment in existing routers codecs LAN switches and PBXs Interfaces such as HSSI T3 E3 and OC3c STM 1 ensure support for newer bandwidth intensive applications On the network side AACs connect to WANs at speeds ranging from T1 E1 to OC 3c STM 1 And to fill the gap between T1 E1 and T3 E3 ATM Forum compliant Inverse Multiplexing for ATM IMA is available The IMA module aggregates up to eight T1 or E1 l