INSTEON 2450 User's Manual
Contents
1. I O Linc The I O Linc Sensor Status LED should turn on if the sensor is closed or turn off it the sensor is open 5 Set I O Linc to linking mode by pressing and holding the Set button until it beeps 3 seconds The white O Linc Status LED should begin blinking 6 Press and hold the responder s Set button for 3 seconds The white I O Linc Status LED should stop blinking and turn on solid 7 Confirm that linking was successful by tapping the Set button on I O Linc The responder should respond appropriately 1 0 Linc 1in a o e Figure 1 Setup modes will automatically time out after 4 minutes Lied Warranty INSTEON warrants to onal consumer of hie product lor a period ot 2 years rm date ot purchase thie product wil be tee tom detects in materal and workmanship and vl ptr substan contormty win Rs Owners Manual Warranty shat not aly to delecta caused BY a INSTEON Page t of 2 Rev 03 15 2012 Protected under U S ad toreign patent see wwe nstzo com Copyright 2012 INSTEON 18542 Miikan Ave Inne CA S2608 800 7627845 Quick Start Guide INSTEON I O Linc Low Voltage Contact Closure Interface Controlling a Door Strike from an INSTEON Device This mode is used for controlling a normally open momentary switch or button such as using an INSTEON controller to trigger a door strike NOTE These instructions assume your output relay set is set to latching mode default 1 Plug
2. I O Linc into a convenient unswitched outlet The I O Linc Status LED should turn on 2 Using the Set button ensure the relay is closed The I O Linc Status LED should be bright when the relay is closed and dim when open Link your INSTEON Controller s to I O Linc 3 Set the controller to Linking Mode For most controllers press and hold an On or Scene button for 10 seconds or the Set button for 3 seconds 4 Press and hold the Set button on 1 O Linc until it beeps 3 seconds 5 Repeat steps 3 and 4 for each controller you want to use to control I O Linc Set the Output Relay to Momentary Mode A 6 Set I O Linc to linking mode by pressing and holding the Set button until it beeps 3 seconds The I O Linc Status LED should begin blinking 7 Set I O Linc to unlinking mode by pressing and holding the Set button until it beeps again 3 seconds The I O Linc Status LED should continue blinking 8 Set I O Linc to output relay programming mode by pressing and holding the Set button until it beeps a third time 3 seconds The I O Linc Status LED should stop blinking and turn on solid 9 Connect the door strike and power supply to I O Linc see Figure 2 10 Test by either tapping the I O Linc Set button or the button you linked to on the controller The I O Linc relay should close and then reopen after a few seconds 11 For instructions on how to set up the following features consult the Owner s Manual a Increase the amount of time the momen
3. Quick Start Guide V O Linc INSTEON Low Voltage Contact Closure Interface 1 In 1 Out Model 2450 Introduction Monitor and control any low voltage devices such as contact closures electric door strikes and alarm sensors as part of your INSTEON home automation network Plus use the built in single pole double throw SPDT switch to connect any low voltage powered device for continuous or momentary operation Create your own remote control door lock using a door strike and power supply or use a security sensor to trigger INSTEON controlled lights to turn on or off I O Linc acts as a repeater for all powerline INSTEON signals is compatible with INSTEON and X10 products and has a pass through outlet for other AC devices Items Required e Sensor wire 20 22 gauge recommended VO Linc Screw Terminals BV GND Sense NIG NO Common Switches 5Volts Ground Sensor Normally Normally between 10mA input closed open N O and NIC Using a Sensor as an INSTEON Controller 1 Plug I O Linc into an unswitched outlet near your sensor The I O Linc Status LED should turn on 2 3 Connect the other sensor wire to the I O Linc Sensor terminal 4 Connect one sensor wire to the I O Linc GND terminal see Figure 1 Pass through outlet Sensor Status LED Set button Status LED Sensor Screw terminals 3 5mm jack Put your sensor in the state that will trigger an ON command from
4. tary relay is closed from 2 seconds up to 25 seconds b Trigger your momentary closure with an OFF command only c Trigger your momentary closure with both ON and OFF commands d Use the I O Linc sensor input to determine whether the I O Linc output will respond To be sure I O Linc is in latching mode tap the Set button and wait a few seconds If you only hear one click I O Linc is in latching mode If you hear two clicks I O Linc is in a momentary mode return I O Linc to latching mode or perform a factory reset see Owner s Manual MOMENTARY MODE on CEL EE 1 0 Linc OFF sv onn sensel we wo com DOOR STRIKE ej e IN RemoteLinc power SUPPLY Figure 2 Complete Instructions Troubleshooting and Tech Support Owner s Manual www smarthome com manuals 2450 pdf Call INSTEON Support Line at 800 762 7845 Lined Warranty INSTEON warns oof consumer of is rd tor a pad ot 2 years rom date ot purchase is product wil be te Hom mere detects in materal and workmanship and vl perar In substantial contormity wth Rs Gunes Manual Warranty shat not aly to delecta caused by Page 2 of 2 misuse or negeer a e cron INSTEON
Download Pdf Manuals
Related Search
Related Contents
Standalone Network Video Recorder - Micronet Article Heading Cypress Semiconductor CYBL10162-56LQXI Datasheet Planificacion AutoCad 2015 + Planificación SOLICITATION AMENDMENT MODIFICATION Novo 107 Color CE Trebs 99211 Drahtloser 54g Desktop- Netzwerkadapter Journal 65 - URPS des médecins libéraux 8. Pipetage - Wenk LabTec Copyright © All rights reserved.
Failed to retrieve file