Home

Harman Stove Company 929BV User's Manual

image

Contents

1. Exterior chase Approved wall pass through m T xg qe to an outside chase e dem Rear exit venting Rain cap B Vent pipe WARNING Operation of this heater when not con nected to a properly installed and maintained venting system or tampering with the vent safey shutoff system can result in carbon monoxide CO poisoning and pos sible death The Clarity gas heater 1s equipped with its own internal draft hood so no additional external draft hood is required The heater should be installed so that the draft hood is in the same atmospheric pressure zone as the air inlets to the heater TEST FOR FLUE SPILLAGE A spillage test should always be made at the completion of the installation I Start all exhaust fans in the home and then close all doors and windows in the room containing the heater 2 Light the heater and allow it to run for 5 minutes on the high output setting If the convection air blower 1s installed it should be turned off for the test 3 Hold a match or other source of smoke near the draft hood outlet on the upper back of the stove 4 If the smoke is not drawn in turn off the heater and determine the cause of the lack of draft If necessary seek expert advice For sites with swirling or turbulent wind conditions a wind cap may solve the problem Approved ceiling roof pass throughs ASSEMBLY The Clarity is shipped from the factory with the log set packed inside the firebox
2. An inspection of the venting system should be made during the annual service appointment The system must have no blockage and must be in good repair The vent manufacturer s instructions may provide specific sugges tions or details on vent inspection Any sections that are taken apart for the inspection must be reassembled and sealed as required CLEANING THE LOG SET AND FIREBOX During the annual inspection and maintenance appoint ment the service person should clean dust lint and any light accumulation from the logs and the firebox area An extra soft brush should be used on the logs as they are extremely fragile a vacuum cleaner may be used on the firebox If at any time the logs cannot be removed or installed without forcing the cause must be found The logs must never be forced Removing the Front See directions on page 6 Removal and Re installation of the Log Set for Cleaning CAUTION The ceramic logs are durable when handled and installed properly However they are deli cate and may be damaged easily 1f not handled with care Handling damage to the ceramic logs is not covered by warranty DO NOT HANDLE LOGS WHILE THEY ARE HOT ALLOW PLENTY OF TIME FOR THE STOVE TO COOL COMPLETELY BEFORE HANLDING Remove the Branch Detach the branch from the two locator pins and re move it Brush it gently and carefully place it to one side Remove the Center Log Lift the center log and remove it Brush it gently and careful
3. The above represents the complete warranty which is given in connection with stoves manufactured by Harman Stove Company No other commitments verbal or otherwise shall apply except by a written addendum to this warranty 20
4. To prepare the stove for installa tion the log set must be unpacked the appropriate burner system module for either natural gas or propane installed and the logs installed Removing the Glass Front NOTE The glass front is heavy Be prepared for its weight when lifting it to avoid damage during removal The wing doors on each side are held closed by magnets Push on each door to open it Loosen the wing nut on each of the two levers Grasp each lever and push to the rear to disengage the front To keep the levers in the disengaged position tighten the wing nuts Lift the glass front slightly and remove it from the stove Set the glass aside in a safe place where it will not be damaged WARNING Do not abuse the Clarity s glass by striking slamming or similar trauma Do not oper ate the Clarity Vented Gas Heater with the glass panel removed The front is released when levers on the left and right sides are pushed to the rear cracked or broken Use only glass supplied by Harman and approved for use with this heater Do not use substi tute materials Replacement of the panel should be done by a licensed or qualified service person Remove and Unwrap the Log Set As shown in the photo above right the log set consists of a back log 1 a center log that has a pilot viewing port in the left end 2 ember strip 3 and a branch that rests on top 4 In addition there are two side brick panels and a back bric
5. remove the Glass door and the log set to gain access to the burner module Remove the burner tubes by sliding to the left while lift ing upward Remove the burner cover plate and the tube box top Step 1 Remove pilot hood with a 7 16 wrench Inside you will find and discard the Propane orifice Install the new Natural Gas orifice from the kit Tighten the pilot hood and assure proper alignment of the directional open ings Step 2 Using a 1 2 in deep well socket remove the three main burner orifices Install the new orifices accord ingly Front 47 Middle 56 Rear 39 Notice the 56 that you removed from the front will be used in the middle for Natural Gas Apply a thread sealer to the orifices prior to installing 17 Step 3 Using a small flat blade screwdriver remove the three screws that hold the LP knob module in place Remove the module and replace it with the Natural Gas module from the kit See kit instructions Step 4 Affix the conversion label to the valve so that any future service tech etc can plainly see that the valve was converted Step 5 Mark the appropriate fuel box on the unit label using a permanent marker Step 6 Affix the Installer Fuel Label in place of the exist ing one Important Perform a leak test upon completion of the fuel conversion NATURAL GAS PROPANE HARMAN CLARITY DIRECT VERI A HVESNI HARADA LARD DIRECT VENT amp HB VENT pod tr SAILHEALDAS lu peed
6. CLAIM Any claim under this warranty should be made to the dealer from whom this appliance was purchased Then contact is made with manufacturer giving the model and serial numbers the date of purchase your dealer s name and address plus a simple explanation of the nature of the defect Extra costs such as mileage and overtime are not covered Nuisance calls are not covered by these warranties THIS WARRANTY IS LIMITED TO DEFECTIVE PARTS REPAIR AND OR REPLACEMENT AT HAR MAN STOVE COMPANY S OPTION AND EXCLUDES ANY INCIDENTAL AND CONSEQUENTIAL DAM AGES CONNECTED THEREWITH WARRANTY EXCLUSIONS Failure due but not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile ceramic log sets paint batteries or battery back up and related duct work are not covered Also excluded from this warranty are consumable or normal wear items including but not limited to flame guides grates coal bars afterburner hoods fire brick gaskets Additional exclusions for corn stoves are burnpot housing weldment burnpot grate weldment pellet or corn burnpot front plate pellet or corn burnpot front plate lock corn auger extension ceramic insert and ceramic insert plate Additional or unusual utility bills incurred due to any mal
7. Install the Branch Orient the branch with the forked end toward the left rear of the stove and slip it over the two locator pins one on top of the back log and the other on the top of the center log y vi F Secure the Glass Front NOTE The glass front is heavy Lift it carefully to pre vent damage Center the glass on the opening and suspend it in place by placing the the tab hooks over the top edge The complete log set with the logs installed and positioned correctly of the opening Loosen the wing nuts that hold the spring loaded levers in place Press the glass slightly against the stove to confirm that it seats properly then press it firmly against the front while pulling the levers forward to engage them Tighten the wing nuts CONNECTING THE HEATER TO A GAS SUPPLY Burn Only the Fuel for which the Heater is Equipped The Clarity B Vent will burn either natural gas or pro pane but requires a dedicated burner system module for either fuel The label on the burner system module indicates the fuel for which it is equipped A second label located near the rating plate also indicates the fuel type NATURAL GAS PROPANE l CESDICCOEBSEBIRDCA 4 i4 in EL y Flex pipe gas inlet Making The Connection m The gas inlet is located at the bottom right rear ofthe stove The inlet fitting 1s a 1 2 female flare flexible pipe A separate gas shut off valve and a 1 8 N P T plugged tapping should be insta
8. 25 14 3 40 08226 15 3 31 965487 16 3 40 00141 17 3 31 08225 18 3 20 408412 19 2 00 4213 20 3 20 326004 21 2 00 4177 22 3 42 2312 23 3 44 1086405 24 3 43 4103 25 3 40 120 26 3 40 121 27 1 10 08285 28 3 44 08278 29 3 40 820628 30 3 40 82057 31 3 40 57356 32 3 40 64347 33 3 40 64739 34 3 40 57271 35 3 40 57753 36 3 40 57753 37 3 40 08231 38 3 40 08229 Part 39 3 40 08230 BVG weldment 40 3 40 08228 Left wing door 41 3 40 08220 Right wing door 42 o 3 31 08282 1 2 gas inlet flex 43 3 31 08283 Rear log 44 o 3 31 08284 Front log 45 3 30 310056082 Top log 46 3 20 326006 Ember strip 47 3 20 326005 Left brick panel 48 3 20 08221 Right brick panel 49 3 20 08219 Rear brick panel 50 2 00 08281 Front burner tube 51 0 46 250 Center burner tube 52 1 00 08513 Rear burner tube 53 1 00 08314 Ext spring 54 3 20 408411 Formed wire gold trim 55 2 00 42208 Magnet 56a 2 00 42220 Snap disc fan control 56b 2 00 42219 snap disc fan control bracket 57 2 00 4169 Power cord 58 1 10 08265 1 Lower rear access cover 59a 1 10 08265 2 Glass gasket 60a 2 00 4138 1 5 8 tight knit rope for door 60b 2 00 4138 2 Gold plated door frame 61 1 10 08287 13 3 4 X 19 glass 62 1 10 08258 5 3 4 X 13 3 4 glass 63 2 00 42217 Distribution blower w ends 64 2 00 4162 Pilot tower gasket 65 2 00 4210 NG valve 66 2 00 4172 LP valve 56 orifice LP front NG center 47 orifice NG front 39 orifice NG rear 71 orifice LP center 53 orifice
9. EM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER RECOMMENDED GAS PIPE DIAMETER Schedule 40 Pipe Inside Diameter Tubing Type L Outside Diameter N G L P N G L P 1 2 3 8 1 2 3 8 1 3 cm 1 0 cm 1 3 cm 1 0 cm 1 2 1 2 5 8 1 2 1 3 cm 1 3 cm 1 6 cm 1 3 cm H2 1 2 3 4 172 1 3 cm 1 3 cm 1 6 cm 1 3 cm 100 150 3 4 1 2 7 8 3 4 2 0 cm 1 3 cm 2 3 cm 2 0 cm NOTE NEVER USE PLASTIC PIPE CHECK TO CONFIRM WHETHER YOUR LOCAL CODES ALLOW COPPER TUBING OR GALVANIZED PIPE Whether or not you have installed a conversion kit fill out the installer fuel label on the stove or the one that was included with the conversion kit and affix it to the stove in the appropriate location HARMAN CLARITY DIRECT YEST HNENI HARMAN CLARET DIRECT VENT amp H VENTI AAILEAL TAS lu i Apgeliance is cqaippsedi f PIDE ASI Tau FRC RPA CONNECTING THE CORDSET The Clarity B Vent Gas Heater must be installed in ac cordance with local codes or in the absence of local codes with the most recent edition of the National Electrical Code ANSI NFPA 70 or the current Canadian Electrical Code 22 1 NOTE The convection fan requires a 120 VAC supply for operation but the heater can be operated without the fan as in the case of a power outage Plug the 3 prong grounded electrical cord plug into the wall WARNING THIS HEATER IS EQUIPPED WITH A THREE PRONGED GROUNDING PLUG THAT SHOULD BE PLUGGED DIRECTLY INTO A PROP
10. ERLY GROUNDED RECEPTACLE DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG Terminal strip for thermostat connec tion 1 spama Rear view of Clarity CONNECTING THE OPTIONAL THERMOSTAT If connecting the optional thermostat it must be plugged into the terminal strip located on the left side near the bot tom of the stove When installing a millivolt control sys tem use only a special low resistance thermostat Do not use a regular heating thermostat Be sure that all electrical connections are clean free from corrosion and tight Inspect connections periodically to confirm that no corrosion has built up over time When properly installed and maintained a millivolt control system should give many years of trouble free service It is important to use wire of a gauge proper for the length of the wire RECOMMENDED WIRE GAUGES Maximum Wire Length Gauge 100 14 60 16 40 18 25 20 15 22 AIR SHUTTER ADJUSTMENT The final step of the installation 1s to check the flame pattern which should resemble the pattern illustrated 1n the right column The flames should be relatively well defined and stable They should be bright yellow with a blue base where attached to the burner ports and should not look orange or sooty Start the heater according to the directions on page 11 and allow the heater to burn for approximately 15 minutes The flames will increase in length and become more yellow in color as the C
11. Installation amp Operating Manual The Harman Clarity 929BV Gas Stove mm Li e Li ii 11 E13 11 0130 838g ii H We suggest that our hearth products be installed and serviced by wat ER Tiy gt professionals who are certified in the U S by au A the National Fireplace ise _ institute MFI as NFI C 0 NER Specialists Ce manuel est disponible en Francais sur demande C LR ek US RS PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOL LOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILDING DEPARTMENT FIRE DEPARTMENT FIRE PREVENTION BUREAU ETC TO DETERMINE THE NEED FOR A PERMIT CETTE GUIDE D UTILISATION EST DISPONIBLE EN FRANCAIS CHEZ VOTRE CONCESSIONNAIRE DE HARMAN STOVE COMPANY WHAT TO DO IF YOU SMELL GAS e DO NOT TRY TO LIGHT ANY APPLIANCE DO NOT TOUCH ANY ELECTRICAL SWITCH DO NOT USE ANY PHONE IN YOUR BUILDING IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS e IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT SAVE THESE INSTRUCTIONS TABLE OF CONTE
12. LP rear 53 orifice LP rear Piezo cable Pilot NG 14 Pilot LP Thermocouple Piezo ignitor 90 brass elbow 1 4 tp 3 8 male compression fitting 3 8 tp 3 8 male compression fitting BHSCS 5mm X 8mm for valve 18 valve harness Harness w VSC On Off rocker switch Thermopile 3 8 tubing 1 4 tubing Valve change over assembly NG Valve change over assembly LP Snap disc safety switch Rear cover Snap disc safety switch bracket Snap disc safety switch heat shield Base trim Latch arm left Latch arm right Latch cam left Latch cam right Front door assembly Top Draft hood heat shield Control door Control heat shield Baffle Clarity B Vent Exploded View 15 Clarity Burner Module Exploded View Appendix A CONVERTING THE CLARITY B VENT FROM ONE GAS TO ANOTHER IN THE FIELD NOTE THE CONVERSION SHALL BE CAR RIED OUT IN ACCORDANCE WITH THE RE QUIREMENTS OF THE PROVINCIAL OR LOCAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH REQUIREMENTS OF THE CURRENT EDITION OF THE NATIONAL FUEL GAS CODE ANSI Z223 1 or the CAN CGA B149 INSTAL LATION CODES CONVERSION KIT COMPONENTS 1 Pilot Orifice installation 2 Burner Orifices 820 NOVA Regulator Assembly i r Coia K Conversion Instructions Installer Fuel Label Conversion Label Must be attached to valve upon com pletion Steps For Completing The Fuel Conversion Prior to installing the fuel conversion
13. NTS INTRODUCTION INSTALLATION Clearances Venting Test for Flue Spillage Assembly Connecting to a Gas Supply Connecting the Cordset and Thermostat Air Shutter Adjustment Monitoring the Gas Flame OPERATION How to Light the Fire How to Turn Off the Fire Lighting Instructions MAINTENANCE Removing the Glass Replacing the Gasket Cleaning the Glass Inspecting the Venting Cleaning the Logset and Firebox Wiring Diagram PARTS LIST amp DRAWING BURNER MODULE EXPLODED VIENW 16 APPENDIX A FUEL CONVERSION APPENDIX B ALTITUDE DE RATING SPECIFICATIONS WARRANTY Morse do dee cutie er Me er 20 Manufactured by HARMAN Tested by parT Harman Stove Co ri Intertek Testing Warnock Hersey 352 Mountain House Road TOV 8431 Murphy Drive Halifax PA 17032 COMPANY Middleton WI 53562 maen ma Introduction The Harman Clarity 929BV Vented Gas Heater is a listed gas fired vented room heater tested by Intertek Testing Warnock Hersey to ANSI standard Z21 88 2002 CSA 2 33 M02 and CAN CGA 2 17 M91 The installation of the Clarity Vented Gas Heater must conform with local codes or in the absence of local codes with the current edition of National Fuel Gas Code ANSI Z223 1 latest edition and CAN 1 B1 149 1 and 2 Installation Code The Clarity 929BV is not for use in mobile homes CAUTION This appliance must be vented to the outside Installation and repair of the Clarity Vented Gas Heater shoul
14. STALLATION CODES Orifice Sizes Front Center Rear Input Btu hr Manifold Pressure Fuel Type Converted By Date of Conversion Clarity B Vent Gas Heater Specifications Tested to ANSI Z21 88 2002 CSA 2 33 M02 CAN CGA 2 17 M91 NATURAL GAS Input Rating Btu hr 0 1375 m 40 000 Min Input Rating Btu hr 0 1375 m 27 000 Injector Sizes DMS front center rear 0 1375 m 47 56 39 Manifold Pressure in w c kPa 3 5 0 87 Minimum Manifold Pressure in w c kPa 1 7 0 42 Minimum Inlet Pressure in w c kPa 5 0 1 25 Maximum Output Btu hr 0 1375 m 30 500 AFUE seasonal efficiency minimum venting 65 2 Steady State Efficiency max input blower on High 78 2 MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION Unit to left sidewall 9in 230 mm Unit to right sidewall 9in 230 mm Unit corner to walls 4in 100 mm Rear of unit to back wall 3in 75 mm measured from rear of draft hood heat shield Unit to alcove ceiling 18 in 460 mm Maximum alcove depth 14in 355 mm Electrical Rating 120 Volts 60 Hz Less than 1 Amp Stove Weight 234 Ibs 19 PROPANE 40 000 28 000 56 71 53 10 0 2 49 5 9 1 47 11 0 2 74 30 800 66 0 79 7 HARMAN GOLD WARRANTY 6 YEAR TRANSFERABLE LIMITED HARMAN WARRANTY Residential GOLD 1 YEAR LIMITED WARRANTY Commercial WARRANTY Harman Stove Company warrants its products to be free from defects in material or workmanship in normal use and ser vice for a
15. d Immedi ately push the red piezo ignitor button to light the pilot It 1s normal to have to push the red button several times before the pilot ignites Continue to hold the control knob in for about one 1 minute after the pilot is lit Release the knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 9 E ron YOUR SAFETY READ BEFORE OPERATING M 1 STOP Read the safety information on the panel above 2 f using optional thermostat set thermostat to lowest setting 3 Tum off electric power to the appliance 4 Turn ON OFF THERMOSTAT switch to OFF position 5 Push in gas control knob slightly and turn clockwise C ww OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force eIf the knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 11 Turn the gas control knob counterclockwise to ON 12 Placethe ON OFF THERMOSTAT switch in the ON position or in the THERMOSTAT position if the optional thermostat 1s used 13 Turn on the electric power to the heater 14 Set the optional thermostat to the desired room tem perature 15 Set the High Low Regulator to desired setting turn fully counterclockwise for High and fully clockwise for Low NOTE An odor
16. d be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More fre quent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the Clarity be kept clean When operating your Harman Clarity Gas Heater respect basic safety standards Read these instructions carefully before you attempt to operate the heater Failure to do so may result in damage to property or personal injury and may void the product warranty Consult with your local building code agency and insurance representative before you begin your instal lation to ensure compliance with local codes including the need for permits and follow up inspections Several issues must be addressed when selecting a suitable location for your Clarity Gas Heater Observ ing required clearances to combustible materials the proximity to a safe chimney or venting system and the accessibility of the gas and electrical supply must all be considered In addition selecting a location that takes advantage of the building s natural air flow is also desirable to maximize the heating effectiveness of the heater In many cases this is a central location within the building Adequate combustion and ventilation air must be provided Due to high temperatures the Clarity Vented Gas Heater should be located o
17. ed Venting The Clarity gas heater is tested and listed for connection to a 4 100 mm listed Class B venting system Ifthe unit is installed to vent through an approved masonry chimney or a factory built chimney system an approved Class B chimney liner must be used Observe local codes when venting the Clarity If no local codes exist follow the current edition of ANSI Z223 1 and CANI B149 installation codes Do not connect the venting to the flue of a chimney that serves a separate solid fuel burning appliance The venting manufacturer s installation instructions must be followed exactly IMPORTANT Because of the high efficiency and low flue gas temperatures of this appliance it is important that it be connected to a well sealed and efficient venting system which is capable of registering a negative pressure while the stove is in operation The most efficient venting systems are those that have a minimum number of bends and minimal horizontal runs The Clarity gas heater 1s equipped with a thermally acti vated vent safety switch that will shut down the main burner if the heater is not properly venting The safety switch will automatically reset after the heater has cooled down The switch will continue to cycle off and on until the venting problem is corrected If you are unable to correct the venting problem seek expert advice from your Harman dealer or installer DO NOT DISCONNECT OR BYPASS THE VENT SAFETY SWITCH ss nae a
18. for POP AE fs CAUTION LABEL ALL WIRES PRIOR TO DISCONNEC TION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING SEE WIRING DIAGRAM ON PAGE 13 Appendix B DE RATING FOR HIGH ALTITUDE For U S installations the Clarity B Vent 1s approved for elevations up to 2000 feet using the factory installed burner injectors At elevations above 2000 feet U S codes require a decrease in the input rating by changing the burner injectors to a smaller size The chart below lists by part numbers the appropriate injectors for both LP and natural gas at various altitudes For high altitude installations consult the local gas dis tributor or the authority having jurisdiction for proper rating methods NOTE The difference in altitude derating requirements for the U S and Canada is simply a result of differences in testing standards between the two countries If the installer must convert the unit to adjust for varying For Canadian installations the Clarity B Vent is ap altitudes an information sticker like the one below must be proved for elevations up to 610 meters 2000 feet For filled out and affixed to the appliance at the time of conver installations from 610 1370 meters 2000 4500 ft the sion orifice sizes DMS for natural and propane gas are as shown in the chart below NATURAL GAS Front Harman Center Harman Rear Harman Nominal Btu Altitude I
19. function or defect in equipment and the labor cost of gaining access to or removal of a unit that requires special tools or equipment are not covered Maintenance needed to keep the stove in good operating condition is not covered This includes but is not limited to cleaning adjustment of customer controls and customer education Labor materials expenses and or equipment needed to comply with law and or regulations set forth by any governmental agencies are not covered This Warranty provides specific legal rights and the consumer may have other rights that vary from state to state In the event of change in ownership the remaining portion of this warranty may be transferred to the new owner by send ing the new owner information and a transfer fee of 25 00 US to the Harman Stove Company PLEASE READ THE LITERATURE BY THE MANUFACTURER FOR THE VARIOUS ACCESSORY DEVICES THE MANUFACTURER WARRANTS THESE ACCESSORY DEVICES NOT HARMAN STOVE COMPANY OR THEIR WARRANTY ADMINISTRATOR FURTHERMORE THESE ACCESSORY DEVICES MUST BE INSTALLED AND USED ACCORDING TO THE RECOMMENDATIONS OF THE MANUFACTURER REMEDIES The remedies set forth herein are exclusive and the liability of seller with respect to any contract or sale or anything done in connection therewith whether in Contract in tort under any warranty or otherwise shall not except as herein expressly provided exceed the price of the equipment or part of which such liability 1s based CLARIFY
20. gh 3 lf knob does not pop up when released stop and immediately call your service technician or gas supplier elf the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas su nde 11 Tum gas control knob counterclockwise 13 Turn on electric power to appliance 14 Set the optional thermostat to desired room temperature 15 Set the High Low Regulator to desired setting tum fully counterclockwise for High and fully clockwise for Low CAUTION Hor waite IN OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING FURNITURE GASO LINE OR LIQUIDS WITH FLAMMABLE VAPORS AWAY ATTENTION cunup PENDANT LE FONCTIONNEMENT NETOUCHEZ PAS TENIR LOIGN S LES ENFANTS LE VETEMENTS ET LES MEUBLES Refer to label on rear of appliance Tor venting information Keep bumer and control compartment clean Refer tp owner s manual accompanying this appliance Maintenir propres le br leur et le compartiment de commande Voir les instructions relatives installation et au tamctianmerment qui usan V radiateur Manulactured by Harman Stove Compan DO MOT REMOVE OF 352 Mountain House Road Halifax PA 17032 717 362 3080 COVER THIS LABEL Maintenance A qualified service person recommended by your Harman dealer should conduct an annual inspection and maintenance of your Clarity its venting and the installa tion to keep it running safely and efficiently These pro cedures
21. he flames should not look orange or sooty Portions of the logs will glow red when the flames are properly adjusted If you find the flames to be other than that described here do not operate the heater Consult a qualified service person or your Harman dealer for advice The Clarity flame pattern will resemble this when the unit is burning properly The properly burning pilot will resemble the illustration to the right Center burner Air adjustment screws Front burner Operation HOW TO LIGHT THE FIRE 1 STOP Read the safety information on the left side of the panel below 2 If using the optional thermostat set thermostat to the lowest setting 3 Turn off electric power to the appliance 4 Turn the ON OFF THERMOSTAT switch to the OFF position 5 Push in the gas con IH trol knob slightly and turn O it clockwise to OFF LO N NOTE The knob cannot be q J turned from PILOT to OFF unless it is pushed in slightly Do not force it 6 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information on the label below If you don t smell gas go to the next step 7 Setthe High Low Regulator to High by turning it fully counterclockwise 8 Press in the gas control knob slightly and turn coun terclockwise to PILOT 9 Find the pilot by looking through the round opening on the left end of the center log 10 Push the control knob fully down and hol
22. k panel The log set components are shipped from the factory individually wrapped and packed inside the stove Take them out of the stove then carefully remove the wrapping Handle the logs gently as they may be damaged easily Install the Back Log and Back Brick Panel These two components are installed as a single piece Rest the back brick panel on the shelf located on the back side of the back log and center it Holding the two pieces as a single unit tilt the top forward slightly and manuever it over the top of the rear burner taking care that the top corners clear the front opening Place it snugly against the back wall and center it Install the Side Brick Panels These slide into place along each side and are held by friction The notch in each panel faces the back Install one side and then the other Install the Ember Strips The ember strips rest against the front of the firebox and should fit snugly Guide them toward you and to the outside until they fit snugly Check the air slot in the inside of the ember strips to confirm that they do not obstruct it Install the Center Log The center log goes all the way to the back and should be centered When properly positioned there should be an even gap along the front of the center burner in the cavity in the log A small portion of the log support frame will be revealed The center log has a round viewing port in the left end through which the pilot can be observed
23. larity heats up If the flames do not resemble the description above and the illustration in the right column the air shutters may be adjusted Three separate screws one for each burner are used to adjust the flames for a particular installation Two of them are accessible through the side access port on the right side of the stove The third 1s accessible from the front when the control door is open The screws may become hot to the touch after prolonged operation Use a 3 16 Allen wrench to avoid contact if hot For best results when fine tuning the flame picture initially leave the middle screw unchanged from its factory setting Turn the other two screws as needed to increase or decrease the brightness and length of the flame turning counterclockwise will increase the flame turning clockwise will decrease the flame 1 To adjust the rear burner open the right wing door reach through the side access port and turn the rear screw to adjust flame see directions above 2 To adjust the front burner first open the control door then turn the front screw to adjust flame see directions above Repeat procedure as needed until desired flame effect 1s achieved MONITORING THE GAS FLAME Periodically the flames of the Clarity B Vent Gas Heater should be checked while it 1s operation The flames should be relatively well defined and stable They should be bright yellow with a blue base where attached to the burner ports T
24. lled immediately upstream of the connection to the appliance The Clarity B Vent Gas Heater must be disconnected from the gas supply piping during any pressure testing of that system at pressures in excess of 1 2 psig 3 5 kPa The Clarity gas control valve must be in the OFF position during any pressure testing of the gas supply system at pres sures equal to or less than 1 2 psig 3 5 kPa WARNING To avoid pipe compounds from entering into the gas train apply compounds only to the male pipe threads and only to the first two threads CAUTION TESTALL JOINTS FOR LEAKS BEFORE OPERATING Gas Pressure Requirements Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and efficient per formance of this appliance Make sure that the plumber or gas supplier checks the gas supply line and gas pressure at installation NOTE Improper gas pressure can affect heater perfor mance flame color or cause pilot outage Natural Gas Maximum inlet pressure 7 0 w c 1 74 kPa Minimum inlet pressure 5 0 w c 1 25 kPa Gas manifold pressure 3 5 w c 0 87 kPa LPG Gas Maximum inlet pressure 13 w c 3 24 kPa Minimum inlet pressure 11 w c 2 74 kPa Gas manifold pressure 10 w c 2 49 kPa DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER OR EXPOSED TO MOISTURE CORROSION IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE HEATER AND REPLACE ANY PART OF THE CONTROL SYS T
25. ly place it to one side with the branch Remove the Ember Strips Carefully remove the ember strips clean them and place them with the other logs Remove the Side Brick Panels Carefully remove first one side panel and then the other Clean and place to side Remove the Back Log and Back Brick Panel Finally carefully remove these two components as a sin gle piece Brush them gently and place them to the side Finish the procedure by vacuuming the interior of the firebox then re install the logs and secure the glass front following the procedures on page 7 Low Voltage MVDC Wiring ii YY Gas Valve ula a AMP Mnte n lalal 4 Circuit Lok Blocked Flue Safety Switch Remote Control Optional The Clarity B Vent gas heater when installed must be electri cally grounded in accordance with local codes or in the absence of local codes with the current edition of the National Electri cal Code ANSI NFPA 70 in the United States or the current Canadian Electrical Code CSA 22 1 in Canada 13 115 VAC Wiring Blower Speed Control w On Off Blower Thermostat Blower Cord Parts Last The following replacement parts for your Harman Clarity B Vent are available from your Harman dealer ID Part No 1 89 08270 2 1 10 08262 1 3 1 10 08262 2 4 3 40 08286 5 3 40 08235 6 3 40 08236 y 3 40 08237 8 3 40 08401 9 3 40 08232 10 3 40 08233 11 3 40 08234 12 3 40 08224 13 3 40 082
26. njector Part No Injector Part No Injector Part No Input Rate 0 2000 47 3 40 64347 56 3 40 57356 39 3 40 64739 40 000 2000 3000 48 MALE 56 3 40 57356 40 MALE 38 400 3000 4000 49 MALE 56 3 40 57356 4 MALE 36 900 4000 5000 49 MALE 57 MALE 42 MALE 35 400 5000 6000 50 MALE 57 MALE 42 MALE 34 000 6000 7000 50 MALE 57 MALE 43 MALE 32 600 7000 8000 5 MALE 58 MALE 43 MALE 31 300 8000 9000 5 MALE 58 MALE 44 MALE 30 100 PROPANE Front Harman Center Harman Rear Harman Nominal Btu Altitude Injector Part No Injector Part No Injector Part No Input Rate 0 2000 56 3 40 57356 71 3 40 57271 53 3 40 57753 40 000 2000 3000 56 3 40 57356 71 3 40 57271 54 MALE 36 900 3000 4000 56 3 40 57356 71 3 40 57271 54 MALE 36 900 4000 5000 57 MALE 71 3 40 57271 54 MALE 35 400 5000 6000 57 MALE 71 3 40 57271 55 MALE 32 600 6000 7000 57 MALE 71 3 40 57271 55 MALE 32 600 7000 8000 58 MALE 71 3 40 57271 56 3 40 57356 30 100 8000 9000 58 MALE 71 3 40 57271 56 3 40 57356 30 100 e When ordering injectors that have no Harman Part number specify MALE or FEMALE and the appropriate 2 digit number THE CONVERSION SHALL BE CARRIED OUT This appliance has been converted for use at an altitude of BY A MANUFACTURER S AUTHORIZED REP RESENTATIVE IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT EDITION OF CAN CGA B141 1 OR CAN CGA B141 2 IN
27. period of 6 years from the date of sales invoice and for mechanical and electrical failures in normal use and service for a period of 3 years from the date of sales invoice If defective in material or workmanship during the warranty period Harman Stove Company will at its option repair or replace the product as described below The warranty above constitutes the entire warranty with respect to Harman Stove Company products HARMAN STOVE COMPANY MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE No employee agent dealer or other person is authorized to give any warranty on behalf of Harman Stove Company This warranty does not apply if the product has been altered in any way after leaving the factory Harman Stove Company and its agents assume no liability for resultant damages of any kind arising from the use of its products In addition the manufacturer and its warranty admin istrator shall be held free and harmless from liability from damage to property related to the operation proper or improper of the equipment THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HERE OF THESE WARRANTIES APPLY only if the device is installed and operated as recommended in the user s manual THESE WARRANTIES WILL NOT APPLY if abuse accident improper installation negligence or use beyond rated capacity causes damage HOW TO MAKE A
28. resulting from the initial heating of new materials in your heater is not unusual during the first fire and in most cases will disappear after an hour or two HOW TO TURN OFF THE FIRE 1 If using optional thermostat set thermostat to the low est position 2 Turn off the electric power to the appliance 3 Turn the ON OFF THERMOSTAT switch to the OFF position 4 Push in the gas control knob slightly and turn it clock wise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in slightly Do not force it LIGHTING INSTRUCTIONS Sa EE ro TURN OFF GAS TO APPLIANCE EE 1 If using optional thermostat set thermostat to the lowest position 2 Turn off electric power to the appliance 3 Turn ON OFF THERMOSTAT switch to OFF position 4 Push in gas control knob slightly and tum clockwise C OF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force A This appliance has a palo When bglhitig thet palot follow these instructions exactly B BEFORE OPERATING smell all around the appliance arsa for gas Be sure to smell next tn the floor because some gas is heavier than air amd will settle on the floor WHAT TO DO IF YOU SMELL GAS De not try to light any gas appliance D nat touch any electric switch do mot use any phone in your building mmeditat call your gas supplier Tram neighbor s phone Follow the gas suppliers instructions ll yo
29. should be performed only by a qualified service person The gas supply should be turned off whenever a maintenance procedure is performed If the front panel side doors or front access door are removed for servicing they must be replaced prior to operating the Clarity REMOVING THE GLASS FRONT FOR REPLACEMENT Refer to page 6 for directions on removing the glass front Use only authorized Harman replacement glass components available from your dealer REPLACING THE GASKET The Clarity has 5 8 diameter fiberglass gasket in the front door Should it ever need replacement use only the proper replacement gasket that is available from your Harman dealer To replace the gasket follow this proce dure 1 Open the door 2 Remove the existing gasket and clean its channel with a scraper or wire brush 3 Lay a thin bead of high temperature silicone the entire length of the channel 4 Lay the gasket in the channel with sufficient pressure that is stays in place 5 Trim the excess from the end of the gasket so that it butts snugly against the other end without leaving a gap Seal the end joint with high temperature silicone 6 Close the door and apply firm pressure to seat the gasket evenly throughout CLEANING THE GLASS The glass may be cleaned with ordinary household glass cleaner and a soft cloth or paper towel WARNING Never clean the glass when it is hot Do not use abrasive cleaners on the glass INSPECTING THE VENTING
30. u canned reach your gas supplier Call the fire department C Use oniy your hand to push in or tum The gas control knob Never usa tools If th knob will nal push in r turn by hand don t try to repair it Calla qualified N 12 Place the ON OFF THERMOSTAT switch in ON position or in the THERMOSTAT position if the optional thermostat is used service technician Force or attempted repair may result in a fire or explosion D Da net use thes appliance if amy part hat been under water immediately call a qualified serice technician to aspect the appliance and to replace any part ol the control system and amy gas control thai has been under water 6 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow E in the safety information above on this label If you don t smell gas go to the next step 7 Set High Low Regulator to HIGH by tuming fully counterclockwise 8 Press in the gas control knob slightly and turn it counterclockwise to PILOT 3 Find the pilot by looking through the round opening in the left end of the center log 10 Push the control knob fully down and hold Immediately push the red piezo ignitor button to light the pilot It is normal to have 1p push the red button several times before the pilot ignites Continue to hold the control knob in for about one 1 minute after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 throu
31. ut of traffic and away from furniture and draperies Children and adults should be alerted to the haz ards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the Clarity Vented Gas Heater Clothing or other flammable materials should not be placed on or near the Clarity Vented Gas Heater INSTALLATION CLEARANCES The following clearances to combustibles must be observed Unit to left sidewall 9 230 mm Unit to right sidewall 9 230 mm Unit corner to walls 4 100 mm Rear of unit to back wall 3 75mm measured from rear of draft hood to wall Unit to alcove ceiling 18 460 mm Maximum alcove depth 14 355 mm LEX gomm Balim ii Clearance to Back wall Clearance from corner of unit to walls Clearance to alcove ceiling 22 14 355mm Maximum alcove depth In addition to these clearances adequate accessibil ity clearance for servicing and proper operation must be maintained Do not in any way obstruct the combustion air inlets that are located under the heater If this appliance is installed directly on carpeting tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel ex tending at least the full width and depth of the appliance VENTING Use Only Approv