Home

Franke Consumer Products FFPD100 User's Manual

image

Contents

1. Franke Consumer Products Inc Kitchen Systems Division extends the following warranty to the origi nal purchaser of its faucets effective January 1 2003 All faucets installed in a private residence will carry a limited lifetime warranty on all mechanical parts to be free of manufacturing defects in material and workmanship under normal usage A chrome finishes carry a limited lifetime warranty all other finishes are warranted for five 5 years form the original date of purchase Marine and Outdoor Installation Franke Consumer Products Inc faucets are NOT warranted for Marine and Outdoor installations This warranty applies only to the original owner providing the product has been installed in accordance with our installation instructions used as recommended and in a normal residential application In the event of a warranty claim the owner will be required to provide proof of purchase save sales receipt This warranty covers all components which make the product operational Franke at its op tion may repair or replace the product or components necessary to restore the product to good working condition Franke reserves the right to inspect the installation prior to the actual replacement of the product or component part This warranty does not cover misuse or abuse accidental damages scuffs or scratches improper installa tion abnormal usage negligence or damage caused by improper maintenance or cleaning Normal wear of p
2. FFPD100 SERIES Swivelling spout faucet with spray head Installation guide i TECHNICAL DATA Minimum working pressure 0 5 bar Maximum working pressure 5 bar H Recommended working pressure 3 bar in case of water pressure higher than 5 bar it is recommended to install pressure reducers f AA CG aN H i ANANO Maximum working temperature 70 C i E Mp WS ENGLISH G 01648 G 28734 XX i 8 az I F j G 01418 XX C G01431 XX C G R0593 G R0338031 PARTS LIST G 1561 XX Handle G R0171 XX Ring cap G 01156 Cartridge G R0338031 Fastening set rubber washer triangular flange metal washer nut TECHNICAL FEATURES Maximum water flow 2 2 gpm 60 psi Recommended pressure range 15 75 psi Over 75 psi PRV required Complies with Proposition 65 NSF61 UPC and C UPC requirements ENGLISH Faucet installation Please remove all components from package and inspect prior to installation see itemized table and picture NOTE Call us immediately if you see inconsistencies 1 800 626 5771 or visit www frankeksd com TABLE OF CONTENTS 1 Faucet Wall fastening set Wall flange over the sink Wall flange under the sink Fastening set rubber washer triangular flange metal washer nut 4 5 Ce Nomreumvaves OCS ENGLISH 2 Remove all mounting hardware from protecting plastic bag 3 Place the large O ring over the faucet shank and place the fa
3. REN lt gt 4 e 2 5 mm 1 8 key s 6 Find the small notch at the base of the chrome ring cap and carefully pry up against this to remove the cap 28 mm 1 1 8 key meg QI 7 Remove the brass retaining ring 8 Lift out the cartridge 9 Ensure that the seats and O rings are in good condition 10 Remove potential mineral deposits from inside the faucet body 11 Install the new cartridge so that the central pivots fit into the corresponding seats 12 Re assemble faucet in reverse order 13 Test for leakage ENGLISH Replacing the Headvalve Shut off the water supply to the faucet 2 Open the faucet briefly to relief any pressure inside the faucet 3 Move the faucet knob to the OFF position 4 Use a the provided allen key to loosen the set screw which is accessible from the back of the handle Lift the handle from the headvalve Unscrew then the headvalve using a 17 mm wrench and replace it Reinstall all the details proceeding in opposite order a mm 1 16 key 17 mm 11 16 key General maintenance Clean aerator periodically Do not use harsh detergents solvents chemical agents metallic sponges etc that could harm the surface Clean only with a soft sponge and soapy water Clean and then dry properly the faucet in case of very hard or calcareous water whose deposits cold damage the surface ENGLISH Limited lifetime warranty
4. arts is excluded from the warranty Damage caused by impurities or acts beyond our control are not covered Any product or part which has been repaired or altered in any manner outside of Franke s fac tory unless previously authorized in writing by Franke will void warranty Any replacement excludes transportation and any labor re installation costs This warranty does not allow recovery of incidental or consequential damages such as loss of use delay property damage or other consequential damage and Franke accepts no liability for such damages The Franke warranty is limited to the above conditions and to the warranty period specified herein and is exclusive Franke DISCLAIMS all other warranties expressed or implied including IMPLIED WAR RANTIES OF MERCHANTABILITY AND OR FITNESS FOR AS PARTICULAR PURPOSE This warranty gives you specific legal rights that may vary from state to state Further information For any further information about our products about the installation of them or about the guarantee please dial the number of the customer service Phone number 1 215 822 6590 Or 1 800 626 5771 Fax number 1 215 822 5873 Franke Consumer Products Inc Kitchen Systems Division 3050 Campus Drive Suite 500 Hatfield PA 19440
5. sponding to the two holes with a 28 mm 1 1 8 interaxe Place the dowels in the holes Fix the plate onto the wall with the given screws give stability to the position of the single lever by acting on the fixing rail and block the movement with the given nut over the sink under the sink 8 Flush out debris from water lines and faucet Pull spray hose out of the faucet spout and point the open end towards the sink drain Open faucet handle cold side first by turning handle to the right and mov ing it upward Let the faucet run on cold for 15 to 30 seconds Open faucet handle hot side second by turning handle to the left and mov ing it upward Let the faucet run on cold for 15 to 30 seconds Turn faucet off Test for leaks under the cabinet ENGLISH Standard maintenance and trouble shooting Cleaning of the spray head Any deposits which may accumulate on the nozzle can be removed by simply running a finger over the rubber extrusions and then running the water for a few seconds In extreme cases this step may have to be repeated Replacing the Cartridge 1 Shut off the water supply to the faucet 2 Open the faucet briefly to relief any pressure inside the faucet 3 Move the faucet handle to the OFF position 4 Use a the provided allen key to loosen the set screw which is accessible from the back of the handle 5 Lift the handle from the cartridge
6. ucet into the desired location NOTE the rubber O ring should be sitting on top of the countertop and between the faucet body DO NOT use putty or other sealant at this location 933 5 1 5 16 D 40 MAX 1 9 16 4 Install the mounting hardware G R0338031 to the threaded shank in the following sequence 1 round flat fiber washer 2 triangular shaped plastic support 3 flat metal washer 4 thread brass nut D A TA 3 M 21 mm 13 16 key 5 Assure that the handle and spout are properly aligned in forward position 6 Tighten the brass nut 4 with the provided wrench or use other professional tools 7 Connect the supply flexible hoses to the supply net interposing between them the non return valve with the gaskets as indicated in the figure NOTE solid surface installation The sub countertop mounting surface needs to be flat and free of debris otherwise the faucet will not sit properly Tile installation Avoid installations near or on top of grout lines The faucet will not sit secure when sitting on such ENGLISH 7 The body can be fixed both onto the wall and on surface Screw the fixing rail onto the single lever body Insert it completely in the given plate Place the single lever body into the sink hole made at a certain distance from the wall Place the plate properly where it has to be fixed making sure the drilling points on the wall are well marked corre

Download Pdf Manuals

image

Related Search

Related Contents

Marshall Amplification MG10CD User's Manual  Tecumseh AJA9486EXDXD Technical Data Sheet  Vizio XVT472SV Flat Panel Television User Manual  Cat Space 2 User Guide  LF 3800 - Jacobsen  Troubleshooting Guide  XC6SLX150 X1 Coprocessor Module User Manual  Operating Instructions - MAMA  eGrants User Guide  ものづくりと安全知の発信 ~グローバル化と安全・国際競争力(MSDP1  