Contents
1. 2 See Figure 4 3 Remove the center screw 4 from the cover 5 Insert the black and white wires from the light fitter 6 thru the hole and thread the switch housing cover tightly onto the light fitter 4 Insert the black and white wires through the lockwasher 8 and hex nut 7 supplied Firmly tighten the hex nut to secure the light fitter to the switch housing cover 5 FAN SWITCH 0 OUSING CHAIN ASSEMBLY 3 WIRE BLUE WIRE E CONNECTORS BLACK WIRE WHITE WIRES 5 COVER 7 HEX NUT Pe 8 LOCKWASHER SCREW A 2 SCREWS Figure 4 5 Carefully locate the white and blue wires labeled either L or LIGHT in the switch housing Remove and retain the wire connectors 3 from the wires 6 Connect the white wire from the ceiling fan to the white wire of the light fitter 6 Connect the blue wire from the ceiling fan to the black wire of the light fitter Use U L listed wire connectors 3 previously removed in Step 5 to make connections Figures 3 and 4 7 Carefully tuck all wires and splices into the switch housing 1 8 Attach the cover light fitter 5 6 to the switch assembly housing 1 using the two outer screws 2 that were removed in Step 2 Figure 4 4 WARNING To avoid fire or electrical shock be careful not to pinch wires between the switch housing assembly and the cover 9 Proceed to Installation of Fluorescent Bulbs and Glass Shade section U L Model No
2. LK59F 1 Installation of Fluorescent Bulbs and Glass Shade A WARNING To avoid fire hazard do not exceed wattage indicated on the fixture 1 Carefully position one of the GU24 fluorescent bulbs 1 Supplied into the light fitter socket Twist the bulb clockwise approximately 1 16 turn to engage the bulbs pins into the light fitter socket holes 2 Figure 5 Install the remaining three GU24 fluorescent bulbs in the same manner 2 Remove the fan switch pendant 3 from the fan switch chain 4 for installation of glass Place the fan switch chain through the light fitter ring 5 hole Figure 5 1 13 WATT GU24 FLUORESCENT BULB 4 2 LIGHT FITTER LIGHT FITTER RING 5 LIGHT FITTER RING HOLES 4 FAN SWITCH CHAIN ic 3 FAN SWITCH Figure 5 gt PENDANT 3 Place glass shade 1 onto light fitter 2 making sure that both fan switch chain 3 and light fitter chain 4 are positioned through the center hole in glass shade 1 Figure 6 4 Slide the switch chain 3 through the side hole of the guide plate 5 and glass cap 6 Figure 6 5 Position the light fitter chain 4 through the center hole of the guide plate 5 hex nut and the glass cap 6 Figure 6 6 Slide the guide plate 5 until it rests gently against the glass shade 1 Secure the glass shade and guide plate by tightening the hex nut finger tight 7 Position the glass cap 6 over the guide plate against the glass shade 1 the
3. equipment and receiver 3 GLASS CAP wire connectors 6 from the wires 9 HEX NUT amp R Stel Connect the equipment into an FAN SWITGH Figure 2 8 LOCKWASHER A 1 SWITCH outlet on a circuit different from 2 FINIAL NUT PENDANT E E N TEE ET Uan that to which the receiver is LIGHT SWITCH Insert the black and white wires trom r PENDANT COUPLING the light fitter 7 through the center hole in the switch cup Figure 2 and thread the switch cup tightly onto the light connected Changes or modifications not Figure 7 expressly approved by the party responsible for compliance could 2 Hold the glass shade 1 securely while fitter Hold wires taut while installing void the user s authority to operate removing the finial nut 2 glass switch cup to prevent the wires from Figure 2 the equipment cap 3 hex nut and the guide plate 4 twisting Figure 7 4 WARNING ad WARNING 3 Carefully place the glass shade finial F OVERELATE nut glass cap hex nut and guide plate 4 MOTOR Over lamping the light kit will result in a safe place while replacing the E with a blown fuse Before replacing bulb s the fuse shut off the electrical supply at the main fuse box or NOTE Use only replacement 13 watt circuit breaker panel The fuse is GU24 fluorescent bulb s D aR 5 SWITCH CUP 3 SCREWS _ CONNECTOR To avoid possible fire or electrical shock make certain no bare wire strands are exposed outs
4. LIMITED WARRANTY What The Warranty Covers All products covered by this Owner s Manual are warranted against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is The fluorescent bulb and electronic ballast are covered by this warranty for two years after the date of purchase all other components are covered for one year after the date of purchase ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Electric Co Do To Correct Problems Emerson Electric Co will replace a defective Emerson Light Fixture at no charge to you WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE LIGHT FIXTURE TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center e To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Electric Co 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request e To r
5. ND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state For repair parts phone 1 800 654 3545 a a EMERSON Air Comfort Products Form No BP7364 1 DIVISION OF EMERSON ELECTRIC CO Printed in China Part No F40BP73640001 8100 W Florissant St Louis MO 63136 01 11 READ AND SAVE THESE INSTRUCTIONS EMERSON Fluorescent Light Fixture Model Numbers LK59FOM01 LK59FSST01 Opal Matte Sandstone Bowl Bowl LK59FWHL01 White Linen Bowl USE THIS FIXTURE ONLY WITH EMERSON CF SERIES CEILING FANS FOUR 13 WATT GU24 FLUORESCENT BULBS INCLUDED Net Weight 4 0 Lbs Part No F40BP73640001 Form No BP7364 1 U L Model No LK59F 1 4 WARNING Safety Instructions To avoid fire shock and serious personal injury follow all instructions carefully 1 Read your Owner s Manual ca
6. er 8 Connect the white wire from the switch cup to the white wire of the light fitter Figure 2 Connect the blue wire from _ 43 WATT GU24 1 Remove all parts and parts packages FLUORESCENT BULB from the carton there is no guarantee that 2 On the ceiling fan remove the switch the switch cup to the black wire of the interference will not occur in a cup 1 from the cover plate 2 by light fitter Use U L listed wire particular installation If this THREADED removing the three screws 3 around connectors previously removed in equipment does cause harmful NIPPLE the side of the switch cup Figure 1 Step 5 to make connections Figures 2 interference to radio or television f and 3 reception which can be determined j 3 Disconnect the motor connector 4 from by turning the equipment OFF and the switch cup connector 5 Figure 1 ON the user is encouraged to correct the interference by one or 4 Remove the center screw 6 from the 2 COVER PLATE s 1 GLASS i i 4 MOTOR more of the following measures we switch cup Figure 1 M MOTOR ae J ey SNITCH CUP i ivi LIGHT FITTER CHAIN FAN SWITCH CHAIN m CONNECTOR Reorient or relocate the receiving 5 Carefully locate the white and blue nine amenna Pe wires labeled either L or LIGHT in BLUE WIRE CONNECTORS Increase the separation between the switch cup Remove and retain the 3 SCREWS WHITE WIRES the
7. eturn the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Light Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co e Mishandling improper installation modifications or damage to your light fixture while in your possession or e Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when e The original purchaser or user ceases to own the product or e The ceiling fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY A
8. ide wire m x i 1 SWITCH 1 connectors located inside the electrical housing 4 Install the replacement bulb in CUP of the light kit fitter Replacement accordance with the Installation of KO CENTER SOHEW Figure 3 fuse shall be rated 125VAC and Fluorescent Bulbs and Glass Shade 1 25A Do do exceed the 1 25A section on Page 5 Figure 1 maximum current rating Replace 9 Carefully tuck all wires and splices the old lamps with new 60W into the switch cup 1 Figure 2 maximum candelabra lamps Restore electrical power to the light 10 Connect the motor connector 4 to the kit at the main fuse box or circuit switch cup connector 5 breaker panel 6 U L Model No LK59F 1 3 U L Model No LK59F 1 11 Position the cup light fitter 1 7 on the cover plate 2 and install the three screws 3 that were previously removed in Step 2 and tighten securely A WARNING To avoid possible fire or electric shock be careful not to pinch wires between switch cup and the cover plate 12 Proceed to Installation of Fluorescent Bulbs and Glass Shade section Installation on Emerson Fans Having Two Piece Die Cast Switch Housings 1 Remove all parts and parts packages from carton A WARNING To avoid possible electric shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring 2 Remove the cover 5 from the fan switch housing 1 by removing the two outer screws
9. mbly and Installation 4 WARNING A WARNING Do not install or use the light fixture To avoid possible electrical shock if any part is missing or damaged be sure electricity is turned off at the Call toll free 1 800 654 3545 main fuse or circuit breaker box before wiring NOTE The GU24 fluorescent bulbs for this light fixture are not dimmable Wall controls and remote controls with a light dimming function should not be used in conjunction with this light kit 2 U L Model No LK59F 1 How To Order Repair Parts When ordering repair parts always give the following information Name of Item Part Description Model Number The model number will be found on a label attached to the light kit fitter For repair parts phone 1 800 654 3545 Notes 7 U L Model No LK59F 1 7 Insert the black and white wires through NOTE This equipment has been Replacement of the Installation on Emerson the lockwash r 8 and hex n t 9 a ere RI eaa Fluorescent Bulbs Fans with Modular supplied Firmly tighten the hex nut to equipment generates uses and can 1 Remove the pendants from the fan and Detachable secure the light kit fitter 7 to the switch radiate radio frequency energy and light switch chains Figure 7 Switch Cups cup 1 Figure 2 if not installed and used in accordance with the instructions may cause harmful interference to radio communications Howev
10. n secure by tightening the finial nut finger tight Figure 6 8 Install the fan switch pendant on the fan switch chain Engage the coupling chain pendant 9 to the light fitter chain 4 Figure 6 9 Reinstall the fan switch pendant 8 to the fan switch chain 3 13 WATT GU24 FLUORESCENT BULB NIPPLE 1 GLASS SHADE 4 LIGHT FITTER 8 3 FAN SWITCH oe CHAIN 5 GUIDE PLATE 5 HEX NUT 7T Ss A 6 GLASS CAP E i 8 FAN SWITCH 7 FINIAL NUT Sli 9 LIGHT SWITCH PENDANT COUPLING Figure 6 10 Installation is now complete Turn on the electricity at the main fuse or circuit breaker box U L Model No LK59F 1
11. refully before installing the light fixture Retain Owner s Manual for future reference 2 Be careful of the fan and blades when cleaning painting or working near the fan Before installing or servicing the light fixture or ceiling fan switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 3 Do not exceed the wattage indicated on fixture ADDITIONAL SAFETY INSTRUCTIONS FOR INSTALLATION 1 To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring 2 Make certain no bare wires are exposed outside the wire connectors 3 All wiring must conform to national and local electrical codes 4 Follow the recommended instructions for the proper method of wiring your new light fixture If you feel you do not have enough electrical wiring knowledge or experience have your light fixture installed by a licensed electrician Any electrical work not described in this manual should be performed by a licensed electrician To reduce the risk of possible fire and electrical shock install only on Emerson CF Series Ceiling Fans This light kit is not to be used with CF652 CF653 CF654 CF670 CF680 CF690 CF695 CF742 and CF2000 Model Ceiling Fans installed in damp or wet locations Asse