Home
        Dickson Industrial SC3 User's Manual
         Contents
1.    SC3    Temperature Chart Recorder Operation    Contents     Product Applications and Useful Features  Product Specifications   Operating Instructions   Getting Started  Charts  amp  Accessories   Calibrations   Troubleshooting   Warranty   Factory Service  amp  Returns       Rev  10 07    y  A  A  u  fe   2       Product Applications   The SC3 sets a new standard for compact recorders while providing the accuracy and resolution required  for regulatory compliance and quality control  The reusable SC3 is rugged enough to withstand the rigors of  transportation and storage applications  Best of all  its unbeatable low price makes temperature recording  affordable for virtually any application    Useful Features   e Rugged case ideal for transportation and storage applications     F C Switchable  24 hour 7 day Switchable    e Easy user calibration    n  3      2     a  o     o     u    3 suonesijddy    e Security slots for recorder security   e Special ranges for refrigerators  freezers  incubators and ambient conditions  e Optional tamper seals can be used to insure the integrity of the chart     Compact  less than 4    tall wide  and durable   e Operates for up to 2 years on a single    AA    battery    e Direct sensing  no remote probe  compact enough to be placed almost anywhere    Product Specifications       Temperature Sensor  Precise spiral wound bi metallic strip transducer   Recorder Accuracy   4  F   2 5  C  over full scale   Ambient Operating Tempera   22 to  122 
2.  F   30 to  50  C    ture    Response Time  1 minutes to move 63  of full scale in air moving 5  per second   Temperature Ranges     F or   C depending on chart installed   14 to  32  F   25 to 0  C     4 to  50  F   15 to  10  C    22 to  68  F   5 to  20  C     50 to  96  F   10 to  35  C    76 to  122  F   25 to  50  C    Recording Time  24 hour or 7 day   Power Supply  Single    AA    battery  up to 2 years average life   Resolution  Not less than 1    per  55  F in 1  C or 2  F steps   Mounting  Free standing  wall mounted or suspended   Chart Size  3     75mm  DIA   Dimensions  3 667  x 3 667  x 2 232   93mm x 93mm x 57mm    Weight  0 5 Ibs   227 g    Includes  Battery  pen and instruction manual    Rev  10 07       Getting Started      Place chart on recorder    e Set time by inserting a coin into chart hub and turning clockwise until the current hour is referenced to  the time index clip   Time index clip is directly to the right and below the pen tip      e Remove protective pen cap  The chart movement is self starting and runs continuously  Allow unit to  stabilize in environment for 15 minutes    Pen Replacement   e Slide the used pen cartridge off and slide the new one on  Typical pen life is one year     Battery Replacement    e The battery compartment is located on the back of the recorder  The recorder uses a standard    AAA     battery for up to two years of battery life     e Insert new battery with the positive end down    Chart Rotation Speed    The unit ha
3.  or incidental damages resulting from failure or malfunc  tion of its products     Customer Satisfaction    Dickson takes pride in providing you  the customer  with the highest quality instrumentation  We welcome  the opportunity to help you in any way possible  Whether it be a question or a new idea in documentation   the Dickson Company would like to hear your response  Please call our Customer Service Department at  1 800 323 2448 or  630  543 3747  in Illinois      Software Return Policy    IMPORTANT Read your Software License Agreement carefully before installing software  Dickson will  accept returns for replacement of defective disks and CDs only     DICKSON  930 South Westwood Avenue  Addison  Illinois 60101    Rev  10 07 Phone   630  543 3747 e E mail  DicksonCSR dicksondata com    EJ  M              u    3 Ayueuem  Burjooyssjqnoig       SC3    3    teledeteccion de temperatura        Arranque rapido    1   2     Este registrador se entrega con una pila AA instalada     Ajuste el interruptor en la parte posterior de la unidad a la velocidad adecuada del motor  7 dias 6 24  horas     Reemplace el papel para graficos con un grafico nuevo    Ajuste el tiempo insertando una moneda en el concentrador de gr  ficos y girando en el sentido   de las agujas del reloj hasta que la hora correcta se referencia en el temporizador   El temporizador se  encuentra directamente a la derecha y por debajo de la punta del estilete     Quite la tapa protectora del estilete     El movimien
4.  selettore a tergo dell unit   sull   idonea velocit   del motore  7 giorni o 24 ore   3  Sostituire il foglietto diagramma con un diagramma nuovo   4    Impostare l ora inserendo una moneta nel perno del diagramma e ruotando in senso orario fino  all indicazione dell ora corretta nell indicatore dell ora   L indicatore dell ora si trova direttamente a  destra e sotto la punta del pennino      Togliere il cappuccino protettivo del pennino     6  Il movimento del diagramma inizia da solo e continua ininterrottamente  Consentire all unit   di  stabilizzarsi nell ambiente per 15 minuti     La garanzia Dickson    Garanzia  Dickson garantisce che SC3 sar   privo di difetti di materiale e manodopera nelle condizioni  normali d uso e di servizio per il periodo di dodici mesi dalla consegna     Per assistenza tecnica o per ordinare accessori e carta diagramma  accedere al sito www DicksonData com       
5. manship under  normal use and service for a period of twelve months after delivery  In the event of a claim under this  warranty  the product or part must be returned to the factory for repair or replacement  shipping pre paid   with a Return Authorization Number  see Return Information above   It will be repaired at Dickson s option  without charge  This warranty DOES NOT cover routine calibration  pen  chart and battery replacement  The  foregoing warranty and remedy are exclusive and in lieu of all other warranties either expressed or implied   Dickson shall not be liable for consequential or incidental damages resulting from failure or malfunction of  its products  Dickson makes no warranty for products not manufactured by it or for any products modified by  buyer  or subject to misuse or neglect     Factory Service  amp  Returns    Contact the factory  630 543 3747  for a Return Authorization  RA  Number before returning any instru   ment  The model number  serial number and a purchase order number will be requested before an RA  number is issued     e Carefully repack the instrument  label the outside of the box with the RA  and return the instrument   freight pre paid  to Dickson    e All instruments that do not have the RA  clearly marked on the outside of the box will be refused   When returning instruments for credit  please include all accessories in shipment    e Calibration Freight charges are non refundable     NOTE  Dickson shall not be liable for consequential
6. manufacturer of humidity and temperature instrumentation to receive A2LA accredita   tion  We are also NIST Traceable  our procedures conform to MIS STD 45662A  ANSI NCSL 2540 1 1994   ISO IEC Guide 25 and IS010012  We are experts in the manufacture and calibration of humidity and tem   perature instruments     Fast Service  Our turnaround time is 3 days or less so you receive not only expert service but fast  service as well     Easy  We make it easy for you  No phone calls for Return Authorization Numbers are required  We  remind you when your instrument is due for calibration  You simply send in the completed Calibration    Order Form with your unit for calibration with freight prepaid to Dickson     Calibration    Periodically check accuracy with a test gauge  If pen adjustment is required  use the adjusting screw located  inside the door on the upper left corner of the dial plate  Check two points on the scale when adjusting the  pen to make sure recorder calibration is maintained     Note  When no signal  no pressure  is being applied to the recorder  the pen may not rest exactly on the  zero chart line  It is possible for the allowable 2  of scale error to occur at zero  while upscale readings are  increasingly more accurate     Rev  10 07    a  a        o  ES         n       Troubleshooting  For troubleshooting information  click here for the technical support page   Warranty    Dickson warrants that the products it sells will be free from defects in material and work
7. on Dickson instrumentation  regular calibrations are necessary to ensure  accurate readings     The following Calibration Services are available     e N150 NIST Traceable Calibration 1 Point  Includes documentation to one Dickson pre selected  point after re calibration     e  N350 NIST Traceable Calibration 3 Point  Includes documentation of three Dickson pre   selected points  a high  medium  and low  after re calibration     Why should I recalibrate my instrumentation     Over time dirt  dust and normal handling can throw your precision instrumentation out of calibration  Regu   lar calibrations ensure that you receive the most accurate readings possible     How often should   recalibrate my instrumentation        Depending on the environment your instrument is used in and how often it is handled you will want to  recalibrate your instrument every 6 to 12 months  Instruments in environments where there are extreme tem   peratures  wide temperature ranges  humidity or pressure variations  high condensation  dirt  dust and other  debris will require calibration at least every 6 months  Instruments that are frequently moved or in locations  with heavy machinery that cause vibrations should also be calibrated at least every 6 months     Why should   return my instrument to Dickson for calibration     Dickson calibrates your instrument at the factory using proprietary production calibration software that  guarantees proper calibration   Our Capabilities    Dickson is the first 
8. s a switchable clock  you can change the speed from a 7 day to a 24 hour rotation and from a  24 hour to a 7 day rotation  Make sure the right chart is selected for your rotation  Simply move the switch  located on the back of the unit to the speed that fits your application     Charts  tor current pricing go to www dicksondata com or call 1 800 323 2448       F and   C Switchable 7 Day 7 Day 24 Hour 24 Hour  Range   F Chart   C Chart   F Chart   C Chart   14 to  32  F    20 to 0  C C302 c310 c301 c309   4 to  50  F    15 to  20  C C304 c312 C303 c311   22 to  68  F    5 to  20  C C320 C318 C319 C317   50 to  96  F    10 to  35  C   C306 C341 C305 C313   76 to  122  F    25 to  50  C   C308 C316 C307 C315       Accessories  for current pricing go to www dicksondata com or call 1 800 323 2448     Description Order    NIST Traceable Calibration 3 pt   new unit  N300  A2LA Accredited Calibration 3 pt   new unit  N400  Pens  6 red  P222  Locking Wall Mount Case A715  Waterproof Pouch A711    Rev  10 07     gt   a  A  M  n  n      E  M  n    Q  o     of  ss  pe  de  e 2   Pi  o  2       Calibration Services   New Units    e N100 NIST Traceable Calibration 1 Point  Includes documentation to one Dickson pre selected  point on new units only     e N300   NIST Traceable Calibration 3 Point  Includes documentation of three Dickson pre   selected points  a high  medium  and low  on new units only   The Importance and Benefits of Regular Calibrations    Once you begin to use your precisi
9. to del gr  fico es de arranque autom  tico y funciona en forma contin  a  Permita que la  unidad se estabilice en el entorno durante 15 minutos     La garant  a Dickson    Garant  a  Dickson garantiza que el SC3 no presentar   defectos de material y de mano de obra en el uso y  servicio normales durante un periodo de doce meses posteriores a la entrega     Para asistencia t  cnica o para pedidos de accesorios y papel para gr  ficos  entre en la siguiente direcci  n  Web  www DicksonData com    Rev  10 07             SC3    3    Enregistreur de pression       D  buter    1  Cet enregistreur est livr   avec une pile AA install  e     2  R  glez le commutateur    l arri  re de l unit   selon la vitesse appropri  e du moteur  7 jours ou 24  heures     3  Remplacez le graphe en papier par un nouveau graphe     R  glez l heure du graphe en ins  rant une pi  ce dans la fente du connecteur de graphe et en tournant  dans le sens des aiguilles d une montre jusqu    arriver    l heure correcte   L indicateur horaire est     droite et en dessous du bout du stylo      Retirez le bouchon protecteur    6  Le mouvement du graphe est    d  marrage autonome et fonctionne continuellement  Laissez l unit   se  stabiliser dans l environnement pendant 15 minutes    La garantie Dickson    Garantie  Dickson garantit que la ligne SC3 d instruments sera sans d  fauts en mat  riel et en fabrication  sous un usage normal et sera sous service pour une p  riode de douze mois apr  s la livraison     Visite
10. z le site www DicksonData com pour l assistance technique o   pour commander des accessoires et des  graphes     Rev  10 07       SC3    3    Druckaufzeichnungsger  t       Schnellstart    St  ein     D    Ste  Uhr   befi    Ent  Die    en Sie den Schalter auf der R  ckseite der Ger  teei  7 Tage oder 24 Stunden     en Sie die Zeit ein  indem Sie eine Munze in die Di  zeigersinn drehen  bis die korrekte Stunde durch d  ndet sich unmittelbar rechts unterhalb der Stiftspi    ernen Sie die Schutzkappe des Stifts   Diagrammbewegung startet eigenst  ndig und ver              15    inuten  um sich gem     der Umgebung zu stabilis    Die Dickson Gewahrleistung    Gew  hrleistung  Dickson gew  hrleistet f  r die Dauer von 12 Monaten nach der Auslieferung Dienstleistun   gen und dass der die das SC3 bei normaler Benutzung frei von Material  und Verarbeitungsmangeln ist     Bei diesem Aufnahmegerat ist 1 AA Batterie bereits vorinstalliert     nheit auf die angemessene Motorendrehzahl    Ersetzen Sie das Diagrammpapier mit einem neuen Diagramm     agrammnabe einf  gen und dann solange im    en Zeitanzeiger angeben wird  Zeitanzeiger    Ze      auft fortlaufend  Gew  hren Sie der Ger  teeinheit  ieren     F  r technischen Support oder das Bestellen von Zusatzartikeln und Diagrammpapier verweisen wir Sie auf  www DicksonData com    Rev  10 07       SC3    3    Registratore di pressione       Avvio veloce    1 Questo registratore    fornito con una batteria AA installata    2  Impostare il
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Page 1 Page 2 Ce logiciel est depose et tous les droits sont  Woodstock W1683 User's Manual  DEH-X3700UI DEH-X3710UI DEH-X2700UI DEH  Samsung 22" TV monitor se špičkovými vestavěnými reproduktory Uživatelská přiručka  Cruiser vs vers fil-de-fer ds certaines céréales  Samsung Galaxy Y Pro Vartotojo vadovas  P3015 Tray 2 Pick up Assembly Removal and Replacement  Olympus Camedia C-5050 Zoom Digital Camera  use manual milli  Honeywell 7580 Home Gym User Manual    Copyright © All rights reserved. 