Home
Dell PowerEdge C6100 Getting Started Guide
Contents
1. 5 Tighten the thumbscrews to secure the ears of system to the front of the rack PPFFFFFFONOR E aa 8 Getting Started With Your System Optional Connecting the Keyboard Mouse and Monitor Connect the keyboard mouse and monitor optional The connectors on the back of your system have icons indicating which cable to plug into each connector Be sure to tighten the screws if any on the monitor s cable connector Connecting the Power Cable s Connect the system s power cable s to the system and if a monitor is used connect the monitor s power cable to the monitor Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply or a power distribution unit Getting Started With Your System 9 Turning On the System Press the power button s either on the front or back of the system and the monitor The power indicators should light 10 Getting Started With Your System Complete the Operating System Setup To install an operating system for the first time see the installation and configuration documentation for your operating system Be sure the operating system is installed before installing hardware or software not purchased with the system Supported Operating Systems Red Hat Enterprise Linux 5 4 Standard edition x
2. Guide de mise en route 21 6 Serrez les vis serrage main afin de fixer les pattes du syst me l avant du rack NORE EF riada Installation sans outil des rails N AVERTISSEMENT demandez toujours de l aide avant de soulever le syst me N essayez pas de le soulever seul car vous risqueriez de vous blesser N AVERTISSEMENT le syst me n tant pas fix au rack ni aux rails vous devez le soutenir ad quatement au cours de I installation et du retrait pour viter de l endommager ou de vous blesser A AVERTISSEMENT afin d viter un ventuel choc lectrique assurez vous que vous disposez d un troisieme conducteur de mise a la terre de s curit des fils pour l installation du rack L quipement du rack doit assurer un flux d air suffisant pour bien refroidir le systeme VAN PR CAUTION lorsque vous installez des rails dans un rack trous carr s v rifiez bien que les taquets de fixation t te carr e glissent bien dans les trous carr s 22 Guide de mise en route 1 Alignez l embout des rails avec les collerettes verticales pour que les taquets de fixation s ins rent dans le trou du bas de la premi re unit en U et le trou du haut de la deuxi me unit en U Glissez l arri re du rail jusqu enclenchement du loquet REMARQUE les rails peuvent tre utilis s a la fois dans les trous carr s et les trous ronds dde e 2 R p tez l
3. tape pour positionner l embout avant sur la collerette verticale REMARQUE pour retirer les rails appuyez sur le bouton de d gagement du loquet situ au milieu de l embout et d gagez les rails un par un 3 Glissez le syst me dans le rack Guide de mise en route 23 4 Siles deux supports d exp dition du stabilisateur de ch ssis en option sont pr sents retirez les du rack REMARQUE avant de transporter des syst mes d j install s dans le rack assurez vous que les deux supports d exp dition du stabilisateur de chassis en option sont en place du rack IAN ay 24 Guide de mise en route Facultatif Connexion du clavier de la souris et du moniteur Connectez le clavier la souris et le moniteur si n cessaire Aidez vous des ic nes des connecteurs situ s l arri re du syst me pour savoir o ins rer chaque c ble N oubliez pas de serrer les vis situ es sur le connecteur du c ble du moniteur s il en est quip Branchement du ou des c bles d alimentation Connectez le ou les c bles d alimentation au syst me et si vous utilisez un moniteur connectez son c ble d alimentation Branchez ensuite l autre extr mit des c bles d alimentation sur une prise de courant mise la terre ou sur une source d alimentation autonome onduleur UPS ou unit de distribution de l alimentation
4. BNO 4 Inserte el sistema en el rack 5 Silos hay extraiga del rack los dos soportes de transporte para estabilizaci n del chasis opcionales K NOTA Para transportar sistemas que ya est n instalados en el rack aseg rese de que los dos soportes de transporte para estabilizaci n del chasis opcionales se encuentren en su lugar Procedimientos iniciales con el sistema 53 6 Apriete los tornillos mariposa para fijar las pesta as del sistema a la parte frontal del rack NORE EF riada Instalaci n de la soluci n de rieles de montaje sin herramientas N AVISO Siempre que necesite levantar el sistema pida la ayuda de otros Con el fin de evitar lesiones personales no intente mover el sistema usted solo N AVISO El sistema no est fijado al rack ni montado en los rieles Para evitar lesiones personales o dafios en el sistema debe sujetar adecuadamente el sistema durante la instalaci n y la extracci n A AVISO Para evitar que se produzca una descarga el ctrica es necesario que la instalaci n del rack cuente con un tercer conductor de conexi n a tierra El equipo del rack debe proporcionar el suficiente flujo de aire al sistema para mantener una refrigeraci n adecuada PAN PRECAUCI N A la hora de instalar rieles en un rack con orificios cuadrados es importante comprobar que la espiga cuadrada se desliza correctamente a trav s de los orificios cuadrados
5. Seis pulsos de choque aplicados consecutiva mente nos eixos x y z positivos e negativos um pulso de cada lado do sistema de 71 G por at 2 ms Seis pulsos de choque aplicados consecutiva mente nos eixos x y z positivos e negativos um pulso de cada lado do sistema de onda quadrada de 27 G com varia o de velocidade de 235 polegadas segundo 597 cent metros segundo 16 m a 3 048 m 50 a 10 000 p s NOTA Para altitudes acima de 900 m 2 950 p s a temperatura de opera o m xima avaliada em 1 C 300 m 1 F 550 p s 16 ma 10 600 m 550 to 35 000 p s Primeiros passos com o sistema 47 Ambientais continua o N vel de poluentes transportados pelo ar Classe Operacional Armazenamento Altitude Operacional Armazenamento G2 ou inferior conforme definido pela norma ISA S71 04 1985 Um pulso de choque no eixo z positivo um pulso de cada lado do sistema de 31 G por 2 6 ms na orienta o operacional Seis pulsos de choque aplicados consecutiva mente nos elxos x y e z positivos e negativos um pulso de cada lado do sistema de 71 G por at 2 ms Seis pulsos de choque aplicados consecutiva mente nos eixos x y e z positivos e negativos um pulso de cada lado do sistema de onda quadrada de 27 G com variag o de velocidade de 235 polegadas segundo 597 cent metros segundo 16 ma 3 048 m 50 a 10 000 p s NOTA Para altitudes acima de 900 m 2 950 p s
6. 54 Procedimientos iniciales con el sistema 1 Alinee los extremos de los rieles de las pesta as verticales del rack para insertar las espigas en el orificio inferior de la primera posici n U y en el orificio superior de la segunda posici n U Apriete el extremo posterior del riel hasta que el pestillo se asiente en su lugar NOTA Los rieles pueden utilizarse tanto en rieles con orificios cuadrados como redondos dde e 2 Repita el paso 1 para colocar y asentar el extremo frontal en la pesta a vertical NOTA Para extraer los rieles tire del bot n de liberaci n del pestillo situado en el punto medio del extremo y desencaje los rieles 3 Inserte el sistema en el rack Procedimientos iniciales con el sistema 55 4 Extraiga del rack el soporte de transporte para estabilizaci n del chasis opcional si est presente NOTA Para transportar sistemas que ya est n instalados en el rack aseg rese de que el soporte de transporte para estabilizaci n del chasis opcional se encuentre en su lugar 5 Apriete los tornillos mariposa para fijar las pesta as del sistema a la parte frontal del rack 56 Procedimientos iniciales con el sistema Conexi n del teclado el rat n y el monitor opcional Conecte el teclado el rat n y el monitor opcional Los conectores de la parte posterior del sistema incluyen
7. atemperatura de operag o m xima avaliada em 1 C 300 m 1 F 550 p s 16 ma 10 600 m 50 to 35 000 p s N vel de poluentes transportados pelo ar 48 Classe G2 ou inferior conforme definido pela norma ISA S71 04 1985 Primeiros passos com o sistema Dell PowerEdge C6100 Procedimientos iniciales con el sistema Modelo reglamentario XS23 TY3 DELL Notas precauciones y avisos NOTA Una NOTA proporciona informaci n importante que le ayudar a utilizar mejor el ordenador PRECAUCI N Un mensaje de PRECAUCI N indica la posibilidad de da os en el hardware o la p rdida de datos si no se siguen las instrucciones N AVISO Un mensaje de AVISO indica el riesgo de dafios materiales lesiones o incluso la muerte La informaci n contenida en este documento puede modificarse sin previo aviso O 2010 Dell Inc Todos los derechos reservados Queda estrictamente prohibida la reproducci n de este material en cualquier forma sin la autorizaci n por escrito de Dell Inc Marcas comerciales utilizadas en este texto Dell el logotipo de DELL y PowerEdge son marcas comerciales de Dell Inc Intel y Xeon son marcas comerciales registradas de Intel Corporation en los Estados Unidos y en otros pa ses Red Hat y Red Hat Enterprise Linux son marcas comerciales registradas de Red Hat Inc en los Estados Unidos y en otros pa ses SUSE es una marca comercial registrada de Novell Inc en los Estados Unidos
8. autres pays D autres marques commerciales et noms de marque peuvent tre utilis s dans ce document pour faire r f rence aux entit s se r clamant de ces marques et de ces noms ou de leurs produits Dell Inc d nie tout int r t propri taire vis vis des marques et des noms de marque autres que les siens Modele r glementaire XS23 TY3 F vrier 2010 N P 697N1 R v A00 ZA PR CAUTION Lieux acc s restreint Ce serveur est congu pour tre install uniquement dans des lieux a acc s restreint tels que d finis dans Cl 1 2 7 3 de IEC 60950 1 2001 o ces deux conditions s appliquent e Seuls peuvent avoir acc s le personnel d entretien et les utilisateurs qui ont t inform s des motifs des restrictions appliqu es au lieu et des pr cautions prendre e L acc s qui se fait par l interm diaire d un outil ou d un verrou et d une cl ou par d autres moyens de s curit est contr l par le responsable en charge du lieu Installation et configuration N AVERTISSEMENT avant de commencer la proc dure suivante lisez les consignes de s curit fournies avec le syst me Respectez ces consignes D ballage du syst me Sortez le syst me de son emballage et identifiez chaque l ment Installation avec outils des rails A AVERTISSEMENT demandez toujours de l aide avant de soulever le syst me N essayez pas de le soulever seul car vous risqueriez de vous blesser N AVERTISSEMENT le syst me
9. de v deo Controladora de v deo AST2050 conector VGA Memoria de v deo 8 MB Alimentaci n Fuente de alimentaci n de CA por fuente de alimentaci n Potencia 470 W Voltaje 100 240 V CA 50 60 Hz 6 5 3 5 A Disipaci n de calor 2 390 BTU h 700 4 W como m ximo Potencia 750 W Voltaje 100 240 V CA 50 60 Hz 9 5 5 0 A Disipaci n de calor 3 414 BTU h 1 000 5 W como m ximo Procedimientos iniciales con el sistema 61 Alimentaci n continuaci n Potencia Voltaje Disipaci n de calor Potencia Voltaje Disipaci n de calor Corriente de conexi n m xima Bater as por placa base Bater a del sistema Bater a RAID opcional 1 024 W en baja 1 100 W en alta 100 240 V CA 50 60 Hz 12 0 6 7 A 4 575 BTU h 1 340 8 W como m ximo 1 400 W en alta 200 240 V CA 50 60 Hz 8 6 7 2 A 5 432 BTU h 1 592 W como m ximo En condiciones normales de l nea y en todo el rango operativo del sistema la corriente de la conexi n puede alcanzar 25 A por cada fuente de alimentaci n durante 10 ms o menos Bater a de tipo bot n litio ion CR2032 de 3 V Bater a litio ion de 3 7 V Caracter sticas f sicas Altura Anchura Profundidad Peso configuraci n m xima Peso vac o 8 7 cm 44 8 cm 75 1 cm 36 5 kg 20 kg 62 Procedimientos iniciales con el sistema Especificaciones ambientales NOTA Para obtener informaci n adicional sobre medidas ambientales relativas a configu
10. obtener la informaci n m s reciente sobre los sistemas operativos admitidos visite support dell com Otra informaci n til A AVISO Consulte la informaci n sobre normativas y seguridad suministrada con el sistema La informaci n sobre la garant a puede estar incluida en este documento o constar en un documento aparte En el Manual del propietario del hardware se proporciona informaci n sobre las caracter sticas del sistema y se describe c mo solucionar problemas del sistema e instalar o sustituir componentes Este documento est disponible en linea en support dell com manuals En la documentaci n de las aplicaciones de administraci n de sistemas Dell se proporciona informaci n sobre c mo instalar y utilizar el software de administraci n de sistemas Este documento est disponible en l nea en support dell com manuals NOTA Compruebe si hay actualizaciones en support dell com manuals y si las hay l alas antes de proceder a la instalaci n puesto que a menudo sustituyen la informaci n contenida en otros documentos Procedimientos iniciales con el sistema 59 Informacion de la NOM solo para M xico La informaci n que se proporciona a continuaci n aparece en el dispositivo descrito en este documento en cumplimiento de los requisitos de la Norma Oficial Mexicana NOM Importador Dell Inc de M xico S A de C V Paseo de la Reforma 2620 11 Piso Col Lomas Altas 11950 M xico D E N mero de mo
11. z axes one pulse on each side of the system of 27 G faired square wave pulse with velocity change at 235 inches second 597 centimeters second 14 Getting Started With Your System Environmental continued Altitude Operating Storage Airborne Contaminant Level Class Operating Storage Altitude Operating Storage Airborne Contaminant Level Class 16 to 3 048 m 50 to 10 000 ft NOTE For altitudes above 2950 feet the maximum operating temperature is derated 1 F 550 ft 16 to 10 600 m 50 to 35 000 ft G2 or lower as defined by ISA S71 04 1985 One shock pulse in the positive z axis one pulse on each side of the system of 31 G for 2 6 ms in the operational orientation Six consecutively executed shock pulses in the positive and negative x y and z axes one pulse on each side of the system of 71 G for up to 2 ms Six consecutively executed shock pulses in the positive and negative x y and z axes one pulse on each side of the system of 27 G faired square wave pulse with velocity change at 235 inches second 597 centimeters second 16 to 3 048 m 50 to 10 000 ft NOTE For altitudes above 2950 feet the maximum operating temperature is derated 1 F 550 ft 16 to 10 600 m 50 to 35 000 ft G2 or lower as defined by ISA S71 04 1985 Getting Started With Your System 15 16 Getting Started With Your System Dell PowerEdge C6100 Guide de mise en route Model
12. 86_64 e Red Hat Enterprise Linux 5 4 Standard edition x86_32 SUSE Linux Enterprise Server 11 x86 64 VMware ESX Server 4 Update 1 e Citrix XenServer Enterprise edition 5 x K NOTE For the latest information on supported operating systems see support dell com Other Information You May Need A WARNING See the safety and regulatory information that shipped with your system Warranty information may be included within this document or as a separate document The Hardware Owner s Manual provides information about system features and describes how to troubleshoot the system and install or replace system components This document is available online at support dell com manuals Dell systems management application documentation provides information about installing and using the systems management software This document is available online at support dell com manuals K NOTE Always check for updates on support dell com manuals and read the updates first because they often supersede information in other documents Getting Started With Your System 11 Technical Specifications Processor Per System Board Processor type One or two Intel Xeon 5500 or 5600 series processors up to six core processors Expansion Bus Per System Board Bus type Expansion slots PCle Mezzanine PCle PCI Express Generation 2 One x16 half length half height One x8 custom slot Memory Per System Bo
13. A Para transportar sistemas j instalados no rack verifique se os dois suportes de envio de estabiliza o do chassi opcionais est o no lugar certo Primeiros passos com o sistema 37 6 Enrosque os parafusos de aperto manual para prender as abas do sistema ao rack NORE EF riada Como instalar a soluc o de trilhos n o usinados N ADVERT NCIA Sempre que precisar levantar o sistema solicite a ajuda de outras pessoas Para evitar les es n o tente levant lo sozinho N ADVERT NCIA O sistema n o preso ao rack nem montado nos trilhos Para evitar les es pessoais e danos ao sistema apoie o rack do sistema de modo adequado durante a instala o ou remo o A ADVERT NCIA Para evitar poss veis riscos de choque el trico necess rio usar um condutor de seguran a aterrado na instala o do rack O equipamento do rack deve fornecer ventila o suficiente para que o sistema mantenha o grau de refrigera o adequado AVISO Ao instalar os trilhos em um rack de orificio retangular 6 importante garantir que o pino retangular deslize pelos orificios retangulares 38 Primeiros passos com o sistema 1 Alinhe as extremidades traseiras dos trilhos nas guias verticais do rack para instalar os pinos no orificio inferior do primeiro U e no orif cio superior do segundo U Prenda a extremidade traseira do trilho at encaixar a trava NOTA Os trilhos podem ser usados em r
14. Dell PowerEdge C6100 Getting Started With Your System Guide de mise en route Primeiros passos com o sistema Procedimientos iniciales con el sistema DELL Dell PowerEdge C6100 Getting Started With Your System DELL Notes Cautions and Warnings NOTE A NOTE indicates important information that helps you make better use of your computer TX CAUTION A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed N WARNING A WARNING indicates a potential for property damage personal injury or death Information in this document is subject to change without notice 2010 Dell Inc All rights reserved Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc is strictly forbidden Trademarks used in this text De the DELL logo and PowerEdge are trademarks of Dell Inc Intel and Xeon are registered trademarks of Intel Corporation in the U S and other countries Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat Inc in the United States and other countries SUSE is a registered trademark of Novell Inc in the United States and other countries VMware is a registered trademark of VMware Inc in the United States and or other jurisdictions Citrix and XenServer are trademarks of Citrix Systems Inc and or more of its subsidiaries and may be registered in the United States Patent and Trademark Of
15. PDU Guide de mise en route 25 Mise sous tension du systeme Appuyez sur les boutons d alimentation l avant ou l arri re du syst me et du moniteur Les voyants d alimentation s allument 26 Guide de mise en route Finalisation de l installation du syst me d exploitation Voir la documentation relative l installation et la configuration du syst me d exploitation si vous installez celui ci pour la premiere fois Veillez a installer le syst me d exploitation avant tout l ment mat riel ou logiciel achet s par ment Systemes d exploitation pris en charge Red Hat Enterprise Linux 5 4 Edition standard x86_64 Red Hat Enterprise Linux 5 4 Edition standard x86_32 SUSE Linux Enterprise Server 11 x86 64 VMware ESX Server Mise jour 1 e Citrix XenServer dition Entreprise 5 x REMARQUE pour obtenir les informations les plus r centes sur les systemes d exploitation pris en charge rendez vous sur le site support dell com Autres informations utiles N AVERTISSEMENT voir les informations sur la s curit et les r glementations fournies avec votre syst me Les informations sur la garantie se trouvent dans ce document ou dans un document distinct Le Manuel du propri taire pr sente les fonctionnalit s du syst me et contient des informations de d pannage du syst me ainsi que des instructions d installation ou de remplacement des compo
16. ack de orificio retangular e redondo an E BE 2 Repita etapa para posicionar e instalar a extremidade frontal na guia vertical NOTA Para remover os trilhos puxe o bot o para liberar a trava no centro da extremidade traseira e desinstale cada trilho 3 Deslize o sistema sobre o rack Primeiros passos com o sistema 39 4 Se estiverem presentes remova do rack os dois suportes opcionais de estabiliza o do chassi usados para o envio NOTA Para transportar sistemas ja instalados no rack verifique se os dois suportes de envio de estabiliza o do chassi opcionais est o no lugar certo 5 Enrosque os parafusos de aperto manual para prender as abas do sistema ao rack FFF FOR OR E Fr 40 Primeiros passos com o sistema Opcional Como conectar teclado mouse e monitor Conecte o teclado o mouse e o monitor opcional Os conectores na parte traseira do sistema t m cones que indicam quais cabos devem ser ligados a cada conector Certifique se de apertar os parafusos se houver algum no conector do cabo do monitor Como conectar cabo s de alimentac o Conecte o s cabo s de alimenta o ao sistema e se for usado um monitor conecte o s cabo s de alimenta o ao monitor Conecte a outra extremi dade dos cabos de alimenta o a uma tomada el trica aterrada ou a uma fonte de alimenta o sepa
17. ard Architecture Memory module sockets Memory module capacities 1066 and 1333 MHz DDR3 registered memory modules with ECC Twelve 240 pin DIMMs 2 GB 4 GB or 8 GB Minimum RAM 12 GB Maximum RAM 96 GB Drives Hard drives Up to twelve 3 5 inch hot swappable SAS SATA drives or up to twenty four 2 5 inch hot swappable SAS SATA SSD drives Connectors Per System Board Back NIC Serial USB Video KVM over IP Port Two RJ 45 10 100 1000 Mbps Ethernet 9 pin DTE 16550 compatible Two 4 pin USB 2 0 compliant 15 pin VGA Dedicated Ethernet port for remote management access 12 Getting Started With Your System Video Per System Board Video type Video memory AST2050 video controller VGA connector 8 MB Power AC power supply per power supply Wattage Voltage Heat dissipation Wattage Voltage Heat dissipation Wattage Voltage Heat dissipation Wattage Voltage Heat dissipation Maximum inrush current Batteries per system board System battery RAID battery optional 470 W 100 240 VAC 50 60 Hz 6 5 3 5 A 2390 BTU hr maximum 750 W 100 240 VAC 50 60 Hz 9 5 5 0 A 3414 BTU hr maximum 1024 W low line 1100 W high line 100 240 VAC 50 60 Hz 12 0 6 7 A 4575 BTU hr maximum 1400 W high line 200 240 VAC 50 60 Hz 8 6 7 2 A 5432 BTU hr maximum Under typical line conditions and over the entire system ambient operating range the inrush current m
18. autom tica ou at 24 unidades SAS SATA SSD de 2 5 polegadas com conex o autom tica 44 Primeiros passos com o sistema Conectores por placa de sistema Traseiros Placa de rede Serial USB V deo KVM sobre Porta IP V deo por placa de sistema Dois conectores Ethernet RJ 45 10 100 1000 Mbps DTE de 9 pinos compat vel com 16550 Dois conectores de 4 pinos compat veis com USB 2 0 VGA de 15 pinos Porta Ethernet dedicada para acesso a gerenciamento remoto Tipo de v deo Mem ria de v deo Controladora de v deo AST2050 conector VGA 8 MB Alimenta o Fonte de alimenta o CA por fonte de alimenta o Pot ncia Tens o Dissipa o de calor Pot ncia Tens o Dissipa o de calor Pot ncia Tens o Dissipa o de calor Pot ncia Tens o 470 W 100 240 VCA 50 60 Hz 6 5 3 5 A 2390 BTU h m ximo 750 W 100 240 VCA 50 60 Hz 9 5 5 0 A 3414 BTU h m ximo 1024 W linha baixa 1100 W linha alta 100 240 VCA 50 60 Hz 12 0 6 7 A 4575 BTU h m ximo 1400 W linha alta 200 240 VCA 50 60 Hz 8 6 7 2 A Primeiros passos com o sistema 45 Alimenta o continua o Dissipa o de calor Corrente de entrada m xima Baterias por placa de sistema Bateria do sistema Bateria RAID opcional 5432 BTU h m ximo Sob condi es de linha t picas e dentro da faixa de temperatura ambiente de funcionamento do sistema a corre
19. ay reach 25 A per power supply for 10 ms or less CR 2032 3 0 V lithium ion coin cell 3 7 V lithium ion battery pack Physical Height Width Depth Weight maximum configuration Weight empty 8 7 cm 3 4 in 44 8 cm 17 6 in 75 1 cm 29 6 in 36 5 kg 80 5 Ib 20 kg 44 1 Ib Getting Started With Your System 13 Environmental NOTE For additional information about environmental measurements for specific system configurations see www dell com environmental_datasheets Temperature Operating Storage Relative humidity Operating Storage Maximum vibration Operating Storage Maximum shock Operating Storage 10 to 35 C 50 to 95 F with a maximum temperature gradation of 10 C per hour NOTE For altitudes above 2950 feet the maximum operating temperature is derated 1 F 550 ft 40 to 65 C 40 to 149 F with a maximum temperature gradation of 20 C per hour 20 to 80 noncondensing with a maximum humidity gradation of 10 per hour 5 to 90 noncondensing 0 26 Grms at 5 350 Hz 1 54 Grms at 10 250 Hz for 15 min One shock pulse in the positive z axis one pulse on each side of the system of 31 G for 2 6 ms in the operational orientation Six consecutively executed shock pulses in the positive and negative x y and z axes one pulse on each side of the system of 71 G for up to 2 ms Six consecutively executed shock pulses in the positive and negative x y and
20. de 71 G pendant un maximum de 2 ms en positif et n gatif sur les axes x y et z une impulsion de chaque c t du syst me Six chocs cons cutifs sur les axes x y et z en positif et n gatif une impulsion de chaque c t du syst me d impulsion d onde carr e de 27 G avec un changement de vitesse de 597 cm s 235 po s De 16 a 3 048 m de 50 a 10 000 pieds REMARQUE pour les altitudes sup rieures 900 m tres 2 950 pieds la temp rature maximale de fonctionnement est r duite de 0 55 C 1 F tous les 168 m tres 550 pieds De 16 a 10 600 m 50 a 35 000 pieds Guide de mise en route 31 Environnement suite Contaminants en suspension dans l air Classe G2 ou inf rieure selon la norme ISA S71 04 1985 En fonctionnement Une impulsion de choc de 31 G pendant un maximum de 2 6 ms sur l axe z positif une impulsion de chaque c t du syst me Stockage Six chocs cons cutifs de 71 G pendant un maximum de 2 ms en positif et n gatif sur les axes x y et z une impulsion de chaque c t du syst me Six chocs cons cutifs sur les axes x y et z en positif et n gatif une impulsion de chaque c t du syst me d impulsion d onde carr e de 27 G avec un changement de vitesse de 597 cm s 235 po s Altitude En fonctionnement De 16 3 048 m de 50 10 000 pieds REMARQUE pour les altitudes sup rieures 900 m tres 2 950 pieds la temp rature maximale de fonctionnement est r duite d
21. delo XS23 TY3 Voltaje de 100 240 V CA alimentaci n Frecuencia 50 60 Hz Consumo el ctrico 73 5 A cada entrada para 1 100 W 750 W 6 53 5 A cada entrada para 470 W Especificaciones t cnicas Procesador por placa base Tipo de procesador Bus de expansi n por placa base Uno o dos procesadores Intel Xeon serie 5500 o 5600 procesadores de hasta seis n cleos Tipo de bus Ranuras de expansi n PCIe Tarjeta intermedia PCle PCI Express de segunda generaci n Una x16 de media altura y media anchura Una ranura x8 personalizada Memoria por placa base Arquitectura Zocalos de m dulo de memoria M dulos de memoria registrada DDR3 a 1 066 y 1 333 MHz con ECC Doce DIMM de 240 patas Capacidades del m dulo de memoria 2 GB 4 GB u 8 GB 60 Procedimientos iniciales con el sistema Memoria por placa base continuaci n RAM minima 12 GB RAM maxima 96 GB Unidades Unidades de disco duro Hasta doce unidades SAS SATA de intercambio activo de 3 5 pulgadas o hasta veinticuatro unidades SAS SATA SSD de intercambio activo de 2 5 pulgadas Conectores por placa base Parte posterior NIC Dos RJ 45 Ethernet 10 100 1000 Mbps Serie 9 patas DTE compatible con 16550 USB Dos de 4 patas compatibles con USB 2 0 Video VGA de 15 patas KVM sobre puerto IP Puerto Ethernet dedicado para el acceso a la administraci n remota V deo por placa base Tipo
22. e 0 55 C 1 F tous les 168 m tres 550 pieds Stockage De 16 a 10 600 m 50 a 35 000 pieds Contaminants en suspension dans l air Classe G2 ou inf rieure selon la norme ISA S71 04 1985 32 Guide de mise en route Dell PowerEdge C6100 Primeiros passos como sistema Modelo normativo XS23 TY3 DELL Notas Avisos e Advert ncias NOTA Uma NOTA fornece informa es importantes que o ajudam a utilizar melhor o computador A AVISO Um AVISO indica um potencial de danos ao hardware ou a perda de dados se as instru es n o forem seguidas ZN ADVERT NCIA Uma ADVERT NCIA indica a possibilidade de danos propriedade de les es corporais ou at mesmo de morte As informa es contidas neste documento est o sujeitas a altera es sem aviso pr vio 2010 Dell Inc Todos os direitos reservados Qualquer forma de reprodu o deste material sem a permiss o por escrito da Dell Inc expressamente proibida Marcas comerciais usadas neste texto Dell o logotipo DELL e PowerEdge s o marcas comerciais da Dell Inc Intel e Xeon s o marcas registradas da Intel Corporation nos EUA e em outros pa ses Red Hat e Red Hat Enterprise Linux s o marcas registradas da Red Hat Inc nos Estados Unidos e em outros pa ses SUSE marca registrada da Novell Inc nos Estados Unidos VMware marca registrada da VMware Inc nos Estados Unidos e ou em outras jurisdi es Citrix e XenServer s o marcas regist
23. e r glementaire XS23 TY3 DELL Remarques pr cautions et avertissements REMARQUE une REMARQUE indique des informations importantes qui peuvent vous aider a mieux utiliser votre ordinateur A PR CAUTION une PR CAUTION vous avertit d un risque d endommagement du mat riel ou de perte de donn es en cas de non respect des instructions donn es N AVERTISSEMENT un AVERTISSEMENT vous avertit d un risque d endommagement du mat riel de blessure corporelle ou de mort Les informations contenues dans ce document sont sujettes modification sans pr avis O 2010 Dell Inc Tous droits r serv s La reproduction de ce document de quelque mani re que ce soit sans l autorisation crite de Dell Inc est strictement interdite Marques mentionn es dans ce document Dell le logo DELL et PowerEdge sont des marques de Dell Inc Intel et Xeon sont des marques d pos es d Intel Corporation aux tats Unis et dans d autres pays Red Hat and Red Hat Enterprise Linux sont des marques d pos es de Red Hat Inc aux Etats Unis et ou dans d autres pays SUSE est une marque d pos e appartenant Novell Inc aux Etats Unis et ou dans d autres pays VMware est une marque d pos e appartenant VMware Inc aux Etats Unis et ou dans d autres juridictions Citrix and XenServer sont des marques de Citrix Systems Inc et ou appartenant a ses filiales et peuvent tre enregistr es au Bureau des brevets et marques des Etats Unis et d
24. e systeme Arri re Carte r seau Deux prises Ethernet RJ 45 10 100 1000 Mbit s S rie Un connecteur DTE a 9 broches compatible 16550 USB Deux connecteurs a 4 broches compatibles USB 2 0 Vid o Un connecteur VGA a 15 broches CVS sur Port IP Port Ethernet d di pour acc s de gestion distance Vid o par carte systeme Type de vid o Contr leur vid o AST2050 connecteur VGA M moire vid o 8 Mo Alimentation Bloc d alimentation en CA selon la tension en vigueur Puissance Tension Dissipation thermique Puissance Tension Dissipation thermique Puissance Tension Dissipation thermique Puissance Tension 470 W 100 240 VAC 50 60 Hz 6 5 3 5 A 2390 BTU heure au maximum 750 W 100 240 VAC 50 60 Hz 9 5 5 0 A 3414 BTU heure au maximum 1024 W basse tension 1100 W haute tension 100 240 VAC 50 60 Hz 12 0 6 7 A 4575 BTU heure au maximum 1400 W haute tension 200 240 VAC 50 60 Hz 8 6 7 2 A Guide de mise en route 29 Alimentation suite Dissipation thermique Courant d appel maximal Piles par carte syst me Pile du syst me Batterie RAID en option 5432 BTU heure au maximum Dans des conditions de lignes typiques et dans toute la gamme ambiante de fonctionnement du syst me l appel de courant peut atteindre 25 A par bloc d alimentation pendant un maximum de 10 ms Pile bouton au lithium ion CR 2032 3 V Pack au lithium ion 3 7 V Caract ristiqu
25. el sistema Desembale el sistema e identifique cada elemento Instalaci n de la soluci n de rieles de montaje con herramientas A AVISO Siempre que necesite levantar el sistema pida la ayuda de otros Con el fin de evitar lesiones personales no intente mover el sistema usted solo A AVISO El sistema no est fijado al rack ni montado en los rieles Para evitar lesiones personales o da os en el sistema debe sujetar adecuadamente el sistema durante la instalaci n y la extracci n N AVISO Para evitar que se produzca una descarga el ctrica es necesario que la instalaci n del rack cuente con un tercer conductor de conexi n a tierra El equipo del rack debe proporcionar el suficiente flujo de aire al sistema para mantener una refrigeraci n adecuada Procedimientos iniciales con el sistema 51 1 Coloque el tornillo con la arandela en el orificio del riel seleccionado para establecer la posici n de topes de transporte A AVISO La posici n de los topes de transporte sirve para poder sujetar bien el sistema mientras se extrae No debe utilizarse para realizar reparaciones 2 Silos soportes de extensi n opcionales impiden la instalaci n de los rieles en el rack quite los tornillos del soporte de extensi n 52 Procedimientos iniciales con el sistema 3 Fije los rieles deslizantes a la parte frontal del rack mediante dos tornillos y a la parte posterior mediante cuatro tornillos
26. es physiques Hauteur Largeur Profondeur Poids configuration maximale Poids vide 8 7 cm 3 4 pouces 44 8 cm 17 6 pouces 75 1 cm 29 6 pouces 36 5 kg 80 5 livres 20 kg 44 1 livres Environnement REMARQUE pour des informations suppl mentaires sur les mesures environnementales li es aux diff rentes configurations du syst me voir www dell com environmental_datasheets Temp rature En fonctionnement Stockage 30 Guide de mise en route De 10 35 C de 50 95 F avec un gradient thermique maximal de 10 C par heure REMARQUE pour les altitudes sup rieures 900 m tres 2 950 pieds la temp rature maximale de fonctionnement est r duite de 0 55 C 1 F tous les 168 m tres 550 pieds De 40 65 C de 40 149 F avec un gradient thermique maximal de 20 C par heure Environnement suite Humidit relative En fonctionnement Stockage Tol rance maximale aux vibrations En fonctionnement Stockage Choc maximal En fonctionnement Stockage Altitude En fonctionnement Stockage De 20 a 80 sans condensation avec un gradient d humidit maximal de 10 par heure 5 90 sans condensation 0 26 Grms 5 350 Hz 1 54 Grms avec un balayage de 10 250 Hz pendant 15 minutes Une impulsion de choc de 31 G pendant un maximum de 2 6 ms sur l axe z positif une impulsion de chaque c t du syst me Six chocs cons cutifs
27. fice and in other countries Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell Inc disclaims any proprietary interest in trademarks and trade names other than its own Regulatory Model XS23 TY3 February 2010 P N 697N1 Rev A00 ZN CAUTION Restricted Access Location This server is intended for installation only in restricted access locations as defined in Cl 1 2 7 3 of IEC 60950 1 2001 where both these conditions apply e Access can only be gained by service persons or by users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken e Access is through the use of a tool or lock and key or other means of security and is controlled by the authority responsible for the location Installation and Configuration N WARNING Before performing the following procedure review and follow the safety instructions that came with the system Unpacking the System Unpack your system and identify each item Installing the Tooled Rail Solution N WARNING Whenever you need to lift the system get others to assist you To avoid injury do not attempt to lift the system by yourself N WARNING The system is not fixed to the rack or mounted on the rails To avoid personal injury or damage to the system you must adequately support the system during installation and
28. iconos que indican qu cable debe enchufarse en cada conector Aseg rese de apretar los tornillos si los hay del conector del cable del monitor Conexi n de los cables de alimentaci n Conecte los cables de alimentaci n al sistema y si se utiliza un monitor conecte el cable de alimentaci n correspondiente al monitor Conecte el otro extremo de los cables de alimentaci n a una toma el ctrica con conexi n a tierra o a otra fuente de energ a como por ejemplo un sistema de alimentaci n ininterrumpida o una unidad de distribuci n de alimentaci n Procedimientos iniciales con el sistema 57 Encendido del sistema Pulse el bot n de encendido de la parte frontal o posterior del sistema y el monitor Los indicadores de alimentaci n deber an iluminarse 58 Procedimientos iniciales con el sistema Instalacion del sistema operativo Para instalar un sistema operativo por primera vez consulte la documentaci n de instalaci n y configuraci n del sistema operativo Aseg rese de que el sistema operativo est instalado antes de instalar hardware o software no adquiridos con el sistema Sistemas operativos admitidos Red Hat Enterprise Linux 5 4 Standard edition x86_64 e Red Hat Enterprise Linux 5 4 Standard edition x86_32 SUSE Linux Enterprise Server 11 x86 64 VMware ESX Server 4 Actualizaci n 1 e Citrix XenServer Enterprise edition 5 x K NOTA Para
29. ma solicite a ajuda de outras pessoas Para evitar les es n o tente levant lo sozinho A ADVERT NCIA 0 sistema n o preso ao rack nem montado nos trilhos Para evitar les es pessoais e danos ao sistema apoie o rack do sistema de modo adequado durante a instala o ou remo o N ADVERT NCIA Para evitar poss veis riscos de choque el trico necess rio usar um condutor de seguran a aterrado na instala o do rack O equipamento do rack deve fornecer ventila o suficiente para que o sistema mantenha o grau de refrigera o adequado Primeiros passos com o sistema 35 1 Insira o parafuso com a arruela no orif cio selecionado do trilho para definir a posig o de travamento para transporte A ADVERT NCIA A posic o de travamento para transporte deve ser usada para reposicionar o prendedor para remo o do sistema Ela n o deve ser usada em servico 2 Se houver suportes de extens o opcionais que impe am a instala o dos trilhos no rack remova os parafusos do suporte de extens o para remover o suporte de extens o 36 Primeiros passos com o sistema 3 Para prender os trilhos na parte da frente do rack use dois parafusos e para prend los na parte de tr s do rack use quatro parafusos 4 Deslize o sistema sobre o rack 5 Se estiverem presentes remova do rack os dois suportes opcionais de estabiliza o do chassi usados para o envio K NOT
30. n tant pas fix au rack ni aux rails vous devez le soutenir ad quatement au cours de I installation et du retrait pour viter de l endommager ou de vous blesser N AVERTISSEMENT afin d viter un ventuel choc lectrique assurez vous que vous disposez d un troisi me conducteur de mise la terre de s curit des fils pour installation du rack L quipement du rack doit assurer un flux d air suffisant pour bien refroidir le syst me Guide de mise en route 19 1 Installez la vis avec la rondelle dans le trou s lectionn du rail afin de d finir la position d arr t A AVERTISSEMENT la position d arr t est con ue pour vous permettre de mieux attraper le syst me lorsque vous le retirez Elle n est pas destin e a I entretien 2 Siles supports d extension en option sont install s et emp chent l installation des rails dans le rack retirez les supports d extension en retirant leur vis 20 Guide de mise en route 3 Fixez les rails l avant du rack l aide de deux vis et l arri re du rack a l aide de quatre vis BO 4 Glissez le syst me dans le rack 5 Siles deux supports d exp dition du stabilisateur de chassis en option sont pr sents retirez les du rack K REMARQUE avant de transporter des syst mes d j install s dans le rack assurez vous que les deux supports d exp dition du stabilisateur de ch ssis en option sont en place
31. nte de entrada poder atingir 25 A por fonte de alimenta o por 10 ms ou menos Bateria tipo moeda de ons de l tio CR 2032 de 3 0 V Pacote de bateria de fon de litio de 3 7 V Caracteristicas fisicas Altura Largura Profundidade Peso com a configura o m xima Peso vazio 8 7 cm 3 4 pol 44 8 cm 17 6 pol 75 1 cm 29 6 pol 36 5 kg 80 5 1b 20 kg 44 1 Ib Ambientais NOTA Para obter informa es adicionais sobre as medi es ambientais para configura es de sistema espec ficas visite o site www dell com environmental datasheets em ingl s Temperatura Operacional Armazenamento 10 a 35 C 50 a 95 F com varia o m xima de 10 C por hora NOTA Para altitudes acima de 900 m 2 950 p s a temperatura de opera o m xima avaliada em 1 C 300 m 1 F 550 p s 40 C a 65 C com varia o m xima de 20 C por hora 46 Primeiros passos com o sistema Ambientais continuac o Umidade relativa Operacional Armazenamento Vibra o m xima Operacional Armazenamento Choque m ximo Operacional Armazenamento Altitude Operacional Armazenamento 20 a 80 sem condensa o com varia o m xima de 10 por hora 5 a 90 sem condensa o 0 26 Grms a 5 350 Hz 1 54 Grms a 10 250 Hz por 15 minutos Um pulso de choque no eixo z positivo um pulso de cada lado do sistema de 31 G por 2 6 ms na orienta o operacional
32. raciones del sistema espec ficas vaya a www dell com environmental_datasheets Temperatura En funcionamiento De 10 C a 35 C con una gradaci n de temperatura m xima de 10 C por hora NOTA Para altitudes superiores a 900 m la temperatura maxima de funcionamiento se reduce 1 C cada 300 m En almacenamiento De 40 C a 65 C con una gradaci n de temperatura maxima de 20 C por hora Humedad relativa En funcionamiento Del 20 al 80 sin condensaci n con una gradaci n de humedad m xima del 10 por hora En almacenamiento Del 5 al 90 sin condensaci n Vibraci n m xima En funcionamiento 0 26 Grms a 5 350 Hz En almacenamiento 1 54 Grms a 10 250 Hz durante 15 minutos Impacto m ximo En funcionamiento Un choque en el sentido positivo del eje z un choque en cada lado del sistema de 31 G durante 2 6 ms en la orientaci n de funcionamiento En almacenamiento Seis choques ejecutados consecutivamente en los ejes x y y z positivo y negativo un choque en cada lado del sistema de 71 G durante un m ximo de 2 ms Seis choques ejecutados consecutivamente en los ejes x y y z positivo y negativo un choque en cada lado del sistema de onda cuadrada alisada de 27 G con cambio de velocidad a 597 cm s Procedimientos iniciales con el sistema 63 Especificaciones ambientales continuaci n Altitud En funcionamiento De 16 a 3 048m NOTA Para altitudes superiores a 900 m la temperatura maxima de funcionamien
33. rada como uma fonte de alimenta o ininterrupta ou a uma unidade de distribui o de energia Primeiros passos com o sistema 41 Como ligar o sistema Pressione o bot o liga desliga localizado na parte da frente ou de tr s do sistema e do monitor As luzes indicadoras de alimenta o acender o 42 Primeiros passos com o sistema Conclua a instalac o do sistema operacional Para instalar um sistema operacional pela primeira vez consulte a documenta o de instala o e configura o do sistema operacional Certifique se de que o sistema operacional esteja instalado antes de instalar qualquer hardware ou software que n o tenha sido adquirido com o sistema Sistemas operacionais compativeis Red Hat Enterprise Linux 5 4 edi o Standard x86 64 e Red Hat Enterprise Linux 5 4 edi o Standard x86 32 SUSE Linux Enterprise Server 11 x86 64 VMware ESX Vers o 4 Atualiza o 1 e Citrix XenServer Enterprise edi o 5 x NOTA Para obter as informa es mais recentes sobre os sistemas operacionais compat veis consulte o site support dell com em ingl s Outras informa es teis A ADVERT NCIA Consulte as informa es de regulamenta o e de seguran a fornecidas com o sistema As informa es sobre garantia podem estar inclu das neste documento ou serem fornecidas em um documento separado O Manual do propriet rio de hardware fornece informa es
34. radas da Citrix Systems Inc e ou de suas subsidi rias e podem ser registradas no Escrit rio de Marcas e Patentes dos Estados Unidos e em outros pa ses Outras marcas e nomes comerciais podem ser usados neste documento como refer ncia s entidades que reivindicam essas marcas e nomes ou a seus produtos A Dell Inc renuncia ao direito de qualquer participa o em nomes e marcas comerciais que n o sejam de sua propriedade Modelo normativo XS23 TY3 Fevereiro de 2010 N P 697N1 Rev A00 ZN AVISO Local de acesso restrito Este servidor destina se a instalag o apenas em locais de acesso restrito conforme definido na cl usula 1 1 2 7 3 da IEC 60950 1 2001 segundo a qual as duas condi es a seguir se aplicam e Oacesso pode ser obtido apenas por profissionais de manuten o ou usu rios orientados sobre os motivos das restri es aplicadas ao local e sobre todas as precau es que devem ser adotadas e O acesso dever ser feito com o uso de uma ferramenta ou de uma trava com chave ou outros dispositivos de seguran a sendo controlado pela autoridade respons vel pelo local Instala o e configura o N ADVERT NCIA Antes de executar o procedimento a seguir leia e siga as instru es de seguran a fornecidas com o sistema Como remover o sistema da embalagem Remova o sistema da embalagem e identifique cada item Como instalar a solu o de trilhos usinados A ADVERT NCIA Sempre que precisar levantar o siste
35. removal A WARNING To avoid a potential electrical shock hazard a third wire safety grounding conductor is necessary for the rack installation The rack equipment must provide sufficient airflow to the system to maintain proper cooling Getting Started With Your System 3 1 Install the screw with the washer into the selected hole of the rail to set the travel stop position A WARNING The travel stop position is intended for repositioning your grip for system removal It is not intended for service 2 If the extension brackets optional prevent the installation of rails in the rack remove the extension bracket screws to remove the extension bracket 4 Getting Started With Your System 3 Secure the rails to the front of the rack using two screws and to the back of the rack using four screws 4 Slide the system into the rack 5 If present remove the two chassis stabilizer shipping brackets optional from the rack K NOTE To transport systems already installed in the rack ensure that the two chassis stabilizer shipping brackets optional are in place Getting Started With Your System 5 6 Tighten the thumbscrews to secure the ears of the system to the front of the rack NORE EF riada Installing the Tool Less Rail Solution N WARNING Whenever you need to lift the system get others to assist you To avoid injury do not a
36. sants du syst me Il est disponible en ligne sur le site support dell com manuals La documentation relative aux applications de gestion de syst mes Dell donne des informations sur l installation et l utilisation du logiciel de gestion de syst mes Il est disponible en ligne sur le site support dell com manuals REMARQUE v rifiez toujours si des mises a jour sont disponibles sur le site support dell com manuals et lisez les en premier car elles remplacent souvent les informations contenues dans les autres documents Guide de mise en route 21 Caract ristiques techniques Processeur par carte systeme Type de processeur Un ou deux processeurs Intel Xeon s rie 5500 ou 5600 jusqu a six processeurs coeurs Bus d extension par carte systeme Type de bus PCI Express 2 me g n ration Logements d extension PCle Une x16 mi longueur mi hauteur Mezzanine PCle Une x8 emplacement personnalis M moire par carte syst me Architecture Barrettes de m moire enregistr e DDR3 1066 et 1333 MHz avec ECC Connecteurs de barrettes de m moire Douze DIMM 240 broches Capacit des barrettes de m moire 2 Go 4 Go ou 8 Go RAM minimale 12 Go RAM maximale 96 Go Lecteurs Disques durs Jusqu douze lecteurs SAS SAT 3 5 pouces remplagables chaud ou jusqu vingt quatre lecteurs SAS SATA SSD 2 5 pouces remplagables chaud 28 Guide de mise en route Connecteurs par cart
37. sobre os recursos do sistema e descreve como solucionar problemas do sistema e instalar ou trocar componentes Este documento est dispon vel online em support dell com manuals em ingl s A documenta o do aplicativo de gerenciamento de sistemas Dell fornece informa es sobre como instalar e usar o software de gerenciamento de sistemas Este documento est dispon vel online em support dell com manuals em ingl s NOTA Verifique sempre se ha atualizac es disponiveis no site support dell com manuals em ingl s e leia primeiro as atualiza es pois estas geralmente substituem informa es contidas em outros documentos Primeiros passos com o sistema 43 Especifica es t cnicas Processador por placa de sistema Tipo de processador Um ou dois processadores da s rie Intel Xeon 5500 ou 5600 at processadores six core Barramento de expans o por placa de sistema Tipo de barramento Slots de expans o PCle PCle para mezanino PCI Express Gerag o 2 1 slot x16 de meia altura 6 meio comprimento 1 slot x8 padr o Memoria por placa de sistema Arquitetura Soquetes dos m dulos de mem ria Capacidades dos m dulos de memoria Minimo de RAM Maximo de RAM Unidades M dulos de mem ria registrada DDR3 de 1066 e 1333 MHz com ECC 12 DIMMs de 240 pinos 2 GB 4 GB ou 8 GB 12 GB 96 GB Discos rigidos At 12 unidades SAS SATA de 3 5 polegadas com conex o
38. to se reduce 1 C cada 300 m En almacenamiento De 16 a 10 600 m Nivel de contaminaci n atmosf rica Clase G2 o menos de acuerdo con ISA S71 04 1985 En funcionamiento Un choque en el sentido positivo del eje z un choque en cada lado del sistema de 31 G durante 2 6 ms en la orientaci n de funcionamiento En almacenamiento Seis choques ejecutados consecutivamente en los ejes x y y z positivo y negativo un choque en cada lado del sistema de 71 G durante un m ximo de 2 ms Seis choques ejecutados consecutivamente en los ejes x y y z positivo y negativo un choque en cada lado del sistema de onda cuadrada alisada de 27 G con cambio de velocidad a 597 cm s Altitud En funcionamiento De 16 a 3 048m NOTA Para altitudes superiores a 900 m la temperatura maxima de funcionamiento se reduce 1 C cada 300 m En almacenamiento De 16 a 10 600 m Nivel de contaminaci n atmosf rica Clase G2 o menos de acuerdo con ISA S71 04 1985 64 Procedimientos iniciales con el sistema
39. ttempt to lift the system by yourself N WARNING The system is not fixed to the rack or mounted on the rails To avoid personal injury or damage to the system you must adequately support the system during installation and removal A WARNING To avoid a potential electrical shock hazard a third wire safety grounding conductor is necessary for the rack installation The rack equipment must provide sufficient airflow to the system to maintain proper cooling CAUTION When installing rails in a square hole rack it is important to ensure that the square peg slides through the square holes 6 Getting Started With Your System 1 Align the end pieces of the rails on the vertical rack flanges to seat the pegs in the bottom hole of the first U and the top hole of the second U Engage the back end of the rail until the latch locks in place NOTE The rails can be used in both square hole and round hole racks an E BE 2 Repeat step to position and seat the front end piece on the vertical flange NOTE remove the rails pull on the latch release button on the end piece midpoint and unseat each rail 3 Slide the system into the rack Getting Started With Your System 1 4 If present remove the chassis stabilizer shipping bracket optional from the rack NOTE To transport systems already installed in the rack ensure that the chassis stabilizer shipping bracket optional is in place
40. y en otros pa ses VMware es una marca comercial registrada de VMware Inc en los Estados Unidos o en otras jurisdicciones Citrix y XenServer son marcas comerciales de Citrix Systems Inc o de una o varias de sus filiales y pueden estar registradas en la Oficina de Patentes y Marcas de los Estados Unidos y en otros pa ses Otras marcas y otros nombres comerciales pueden utilizarse en este documento para hacer referencia a las entidades que los poseen o a sus productos Dell Inc renuncia a cualquier inter s sobre la propiedad de marcas y nombres comerciales que no sean los suyos Modelo reglamentario XS23 TY3 Febrero de 2010 N P 697N1 Rev A00 VAN PRECAUCI N rea de acceso restringido Tal y como ha sido definido en Cl 1 2 7 3 de IEC 60950 1 200 este servidor ha sido dise ado para su instalaci n solamente en reas de acceso restringido en donde se aplican las siguientes condiciones e S lo pueden tener acceso personas de asistencia t cnica o usuarios a los que se haya informado de las razones de las restricciones que se aplican al lugar y acerca de las precauciones que deban tenerse en cuenta e El acceso se realiza mediante un dispositivo o una cerradura y llave u otros medios de seguridad y est controlado por la autoridad responsable de esta rea Instalaci n y configuraci n N AVISO Antes de realizar el procedimiento siguiente revise y siga las instrucciones de seguridad incluidas con el sistema Desembalaje d
Download Pdf Manuals
Related Search
Related Contents
4U / 4I - Chauvin Arnoux ダウンロード - プラネックスコミュニケーションズ LAVADORA AUTOMÁTICA Lenovo 3093AC6 User's Manual TRLED 36-3 PAR User Manual Honda GL1800 User's Manual MODE D`EMPLOI User manual mikado - ADB Lighting Technologies VLINN USER MANUAL Copyright © All rights reserved.
Failed to retrieve file