1. CLEAN AIR FILTER in the LED display indicating when it is time to clean the air filter AIR FILTER REMOVAL The air filter is located behind the air intake front grill To remove the air filter grasp the filter handle located on the front of the grill and slide it out to the right To reinstall the air filter reverse the above procedures CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment to remove heavy soil Wash the filter in lukewarm water below 40 C 104 F If the filter is very dirty filter wash with soapy water or a neutral cleaning agent NEVER WASH AIR FILTER IN DISHWASHER Do not use harsh cleaning chemicals to clean the filter as they may damage the piastic and filter mesh Rinse the filter with clean water and dry thoroughly before re installing 2 CAUTION 4 amp NEVER operate the air conditioner without the air filter as dusi dirt particles can contribute to equipment failure x N End of Season Care 1 Operate the fan only high speed for half a day to dry out the internal components of the unit 2 Turn off power and remove plug from wall socket 3 Clean air filter and exterior cabinet 4 Store air conditioner covered in a dry location Trouble shooting Guide Frequently a problem is minor and a service call may not be necessary use this troubleshooting guide for a possible solution If the unit continues to operate improperly call Danby s Toll
2. program is automatically re set therefore we suggest you remove and clean the filter before re Starting the unit TEMPERATURE DISPLAY CELSIUS FARENHEIGHT It is possible to change the LED temperature display to read Celsius or Farenheight by pressing the temperature keypads simultaneously The green pilot light under the C F temperature symbol will illuminate identifying the mode selection CARE AND MAINTENANCE When servicing the air conditioner be sure to turn the air conditioner to the OFF position and disconnect the power cord from the electrical outlet 1 DO NOT use gasoline benzine thinner or other chemicals on the air conditioner as these substances may cause damage to the paint finish and deformation of plastic parts Never attempt to pour water directly on unit as this will cause deterioration of the electrical insulation When the air inlet grill and cabinet are dirty wash in lukewarm water below 40 C 104 F For very dirty conditions wash with soapy water or a neutral cleaning agent AIR FILTER INFORMATION The air filter plays an important role effecting overall performance levels of any air conditioner A clean air filter will maximize cooling efficiency A dirty air filter will minimize cooling efficiency It is important to keep the air filter clean at all times This unit is inclusive of a program that will display a message prompt E1
3. 19 1mm Screws 8 Screws 18 L Top Channel 1 Mounting Brackets 2 Because the compressor is located on the controls side of the unit right side this side will be heavier and more awkward to manipulate inadequate support on control side of the unit can result in personal injury and damage to your unit and property Therefore it is recommended to have someone assist you during the installation of this unit CAUTION Select the Best Location This room air conditioner is designed to fit easily into a single or double hung window However since window designs vary it may be necessary to make some modifications for safe proper installation Make sure window and frame are structurally sound and free from dry and rotted wood For maximum efficiency install the air conditioner on a side of a house or building which favors more shade than sunlight If the unit is in direct sunlight it is advisable to provide an awning over the unit Provide sufficient clearance around the cabinet to aliow for ample air circulation through the unit See Fig 2 The rear of the unit should be outdoors and not in a garage nor inside a building Keep unit as far away as possible from obstacies obstructions and at least 30 76 2cm above the floor or ground Curtains and other objects wothin a room should be prevented from blocking the air flow Be certain the proper electrical outlet is within reach of the insta
4. ce ou service Genre de produit Num ro de mod le Num ro de pi ce Description de la pi ce A Be Danby Products Limited Guelph Ontario Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45839 0669
5. To test if your power supply cord is working properly you must do the following 1 Connect the power supply cord to an electrical outlet 2 The power supply cord is inclusive of two buttons located on the head of the plug One button is marked TEST the other button is marked RESET Press the TEST button you will hear a click as the RESET button pops out 3 Press the RESET button you will hear a click as the button engages 4 The power supply cord is now energized and supplying electricity to the air conditioner On some products this is also indicated by a light on the plug head Energy Saving Tips Your Room Air Conditioner is designed to be highly efficient in energy savings Follow these recommendations for greater efficiency 1 Select thermostat setting that suits your comfort needs and leave thermostat at that chosen setting 2 The filter is very efficient in removing airborne particles Keep air filter clean Normaily filter should be cleaned every 2 weeks More frequent cleaning may be necessary depending on outdoor and indoor air quality 3 Use drapes curtains or shades to keep direct sunlight from heating room but DO NOT obstruct the air conditioner Allow air to circulate around the unit without obstruction Window Installation Electric Shock Hazard To avoid the possibility of personal injury disconnect power to the unit before installing or servicing Tools N
6. 9 Findlay Ohio U S A 45839 0669 AA Telephone 519 837 0920 FAX 519 837 0449 is Telephone 419 425 8627 FAX 419 425 8629 eS 06 Oo K LENON NON RER IR RA OOS Danby Room Air Conditioner The model number of your room air conditioner is found on the serial plate located on the right side of the unit above the power cord Model Mod le All repair parts are available for purchase or special order when you DAC 59 77E E visit your nearest service depot To request service and or the location of the service depot nearest you call the TOLL FREE NUMBER 1 800 263 2629 When requesting service or ordering parts always provide the following information e Product Type Model Number For service contact your nearest Part Number service depot or call e Part Description 1 800 263 2629 Climatiseur de pi ce Le num ro de mod le de votre climatiseur se trouve sur la plaque d information qui se trouve sur le cot droit de l appareil par dessus le cordon d alimentation Toutes les pi ces de rechange ou commandes sp ciales sont 1 800 263 2629 disponibles de votre centre r gional de service autoris Pour exiger le service et ou le nom de votre centre de service r gional signalez le NUM RO SANS FRAIS 1 800 263 2629 Pour obtenir le service consultez votre succursale r gionale de service ou t l phonez Ayez les renseignements suivants la port e de la main lors de la commande de pi
7. Danby USE AND CARE MANUAL MANUEL D UTILISATION Model Mod le DAC5277EE CAUTION Danby Read and Follow All Safety Rules Room Ai r Cond itioner and Operating Instructions Before First Use of This Product Table of contents 5 46 1 PRECAUTION Danby Veuillez lire attentivement Cl i m ati seur de piece les consignes de s curit et les instructions d utilisation avant Table of contents 19 l utilisation initiale de ce produit 1 800 26 Danby Danby Products Limited Guelph Ontario Canada N1H 629 Danby Products Inc Findlay Ohio USA 45839 0669 10 04 Table of Contents Introduction Unit Specifications Electrical Specifications Energy Saving Tips Window installation Operating Instructions Care and Maintenance Trouble Shooting Guide Warranty Parts Identification Exterioor Air Inlet Interior Air Inlet Air Filter Cabinet Front Panel Interior Air Outlet Fresh Air Ventilation Switch Control Panel Door Power Cord 4 ee a lt 7 ee Introduction Thank you for choosing a Danby Room Air Conditioner to cool your home This Use and Care Manual provides information n
8. Free Number 1 800 263 2629 for assistance or call one of our service depots listed in the enclosed Authorized Service Depot listing provided with this unit Difficult Air conditioner will not operate inefficient or no cooling Water dripping outside Water dripping inside Ice or frost build up NOTES Possible Cause No power to unit Dirty air filter Unit size inappropriate for application Blocked air flow Power interruption settings changed too quickly or compressor overload tripped Loose parts Inadequate support Formation of moid mildew or algae on wet surfaces Condensation run off is normal during hot and humid weather Unit is not properly angled to allow water to drain outside Low outside temperature Unit air filter is dirty qualified technician Suggested Solution Check connection of power cord to power source Check fuse or circuit breaker Set SELECTOR SWITCH to position other than OFF Clean or repiace air filter Check with dealer to determine proper unit capacity for application Remove obstruction from grill or outdoor louvers Turn the unit off and wait 5 minutes before attempting to re start Tighten loose parts Provide additional support to unit Clean unit thoroughly Place algaecide tablet in base pan Add flexible tubing to redirect water flow see Fig 25 Unit must be installed on an angle for proper condensat
9. NOTE It is not possible to operate both the auto start and auto stop feature within a single program Ali auto timed programs are automatically erased after the set program is complete cert ONE TOUCH Press tnis keypad to activate a pre set factory temperature setting of 22 C 2 C 71 6 F The air conditioner will operate and maintain the indoor temperature at this setting OPERATING INSTRUCTIONS CONTINUED e FAN Press this keypad to activate the appropriate fan speed setting Each depression of the keypad will alternate through High Medium Low fan speed options The green pilot light directly above the FAN speed option will illuminate identifying the fan speed selected E1 CLEAN AIR FILTER A message prompt E1 will automatically appear in the LED window indicating when it is time to clean the air filter The E1 program is a built in time device that operates based on total air conditioner running time It is very important to keep the air filter clean at all times in order to maximize cooling efficiency See Cleaning Air Filter The air filter must be cleaned when the E1 message is displayed To cancel eliminate the E1 message from the LED display the air conditioner must be disconnected unplugged from the power supply and re connected This action automatically re sets the E1 program internal time device NOTE In the event of a power failure the E1
10. binet as shown in Fig 8 using four 4 1 4 6 4mm screws NOTE Some models may already have the bottom channel factory installed Assembly of the Side Curtains to Cabinet Slide the shutters into the top and bottom channels as shown in Fig 9 The shutters are identified on frame as left amp right Attach the shutters to the cabinet using four 1 4 6 4mm screws on each side Installation of Mounting Brackets and First Sealing Strip SPECIAL NOTE Window applications come in a variety of different styles Therefore it may be necessary to modify or improvise your particular installation Assemble the leveling screw bracket to the bracket assembly as shown in Fig 10 using four 4 1 4 6 4mm scews providded install the leveling screws into each of the leveling screw brackets this will require the use of an adjustable wrench Measure the inside window sill length and find the center as shown in Fig 11 From this line measure 8 1 8 20 6cm on each side and mark these points Align the V slot in each bracket on these marks and mount to the sill using four 3 4 19 1mm screws provided Brackets should be perpendicular to the inside window sill with step in bracket tight against the sill See Fig 12 Adjust the leveling screws until the brackets tilt no more than 3 16 4 8mm downward to the outside Do not allow the brackets to slant inward as condensation could possibly drip on interior walls and flo
11. d to connect your air conditioner use an approved air conditioner extension cord only available at most local hardware stores 6 The rating plate on the unit contains electrical and other technical data The rating plate is located on the right side of the unit above the power cord Table 1 Suggested individual Branch Circuit AWG Wire Size 5 0 to 12 16 AWG American Wire Gage Based on copper wire at105 C temperature rating Table 2 Receptacle and Fuse Types Nameplate Amps Time Delay Fuse or circuit breaker Plug Type Instructions The power cord supplied with this air conditioner contains a current leakage detection device de signed to reduce the risk of fire Please refer to the section Power Supply Cord for details In the event the power supply cord is damaged it cannot be repaied it must be replaced with a new cord from the Product Manufacturer e Under no circumstances should this device be used to turn the air conditioner on or off The RESET button must always be pushed in engaged for correct operation The power supply cord must be replaced if it fails to reset when the TEST button is pushed in lf the power supply cord is damaged it cannot be repaired It must be replaced with a new cord obtained from the Product Manufacturer Power Supply Cord The power cord supplied with this air conditioner contains a device that senses damage to the power cord
12. e compressor on fan on compressor off fan on NOTE The energy saver feature operates in cooling mode only MODE Press this keypad to select the appropriate operating mode Fan Cool Each depression of the MODE keypad will alternate between the COOLING and FAN mode The green pilot light directly above the COOL or FAN mode will illuminate identifying the selected mode is operational D TIMER Press this keypad to activate the auto start auto stop timer programs Auto start stop programs can be programmed from 0 12 hours Each depression of the TIMER keypad will increases the selected time in 1 hour increments AUTO START Before activating the auto start program you must first select set the operating conditions of the air conditioner i e temperature setting and fan speed Once the settings are complete the air conditioner must be switched off non operational Depress the TIMER keypad and the auto start time will appear in the LED display select the required time 0 12hours and the air conditioner will start automatically at the established time AUTO STOP Turn the air conditioner on and select the required operating conditions i e temperature setting and fan speed Depress the TIMER keypad and the time will appear in the LED display select the required auto stop time 0 12hours and the air conditioner will stop automatically at the established time
13. e window Fig 24 Yea Some installations may require additional sealing around the window and air conditioner Check for any air leaks and seal where necessary Under very humid conditions water removal may be excessive enough to overflow from the rear of the unit or increase noise levels of the air conditioner If this occurs consider attaching a standard drain garden hose not included to the drain plug at the rear of the unit allowing condensation to run off conveniently Fig 25 TO O vee _Leftright side of cabinet screws 2nd Foam Seal not included Fig 25 7 Electronic Contro Features LED DISPLAY The LED window displays the following information independantly e Set Cooling Temperature e Ambient Room Temperature Auto on off Timer Programs e 1 Clean Air Filter NOTE During normal operating conditions after all settings are complete the LED readout will always default to show display the ambient room temperature In order to view the set temperature of the air conditioner press either of the temperature key pads once POWER SWITCH turns power on off amp SWING Activates the automatic air swing oscillation feature Q ENERGY SAVER Press and hold the SWING keypad for 3 seconds to activate the ENERGY SAVER program This program is designed to reduce energy consumption by limiting restricting operation of the fan motor with t
14. ecessary for the proper care and maintenance of your new Room Air Conditioner If properly maintained your air conditioner will give you many years of trouble free operation To avoid installation difficulties read these instructions completely before installing operating your unit NOTE This unit is NOT designed for through the wall installation For easy reference you may want to attach a copy of your sales receipt to this page Note foilowing information provided on the manufacturer s nameplate located on the right side of the unit above the power cord This information will be needed when you contact a Customer Service Representative Model Number DAC5277EE Serial Number Date of Purchase Dealer s Name and Address Refer to the trouble shooting section of this Use and Care Manual if the unit is not operating correctly if these suggestions do not solve the problem contact an authorized service representative or call Danby TOLL FREE 1 800 26 Danby PIN CAUTION A Do not leave a room air conditioner unattended in a space where people or animals who cannot Keep these instructions for future reference This symbol denotes a caution or warning react to a failed unit are located A failed unit can AN cause extreme overheating or death in such an enclosed unattended space Model No DAC5277EE Unit Specificafications Voltage 115V 60Hz Cooling Capacity Btu h 5 250 Input Wattage 490 Ene
15. eeded for Window Installation Screw Drivers Both Phillips and flat head Power Drill 1 8 inch 3 2mm diameter drill bit Pencil Measuring Tape Scissors Carpenters Level Adjustable Wrench My cauTION 4A To avoid installation operation difficulties read these instructions thoroughly Your Room Air Conditioner is designed for easy installation in a single or double hung window NOTE This unit is NOT designed for vertical slider type windows and or through the wail applications NOTE Save the shipping carton and packing materials for future storage or transport of the unit Remove from carton the plastic bag containing the installation hardware kit necessary for the installation of your air conditioner Please check the contents of hardware kit agaist the corresponding model check list prior to installation of the unit See Fig 1 sn 1 4 6 4mm Start your air conditioner before outdoor air becomes hot and uncomfortable This avoids an initial period of discomfort while unit is cooling off the room When outdoor ae are cool enough use HIGH FAN MED FAN or f LOW FAN only Fes on your model This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting Fig 1 Installation Hardware Shutter Brackets 2 Side Curtain RH 1 Side Curtain LH 1 CS Foam Seal P Levelling Legs 2 Fiat Washers 8 3 4
16. he lower left right edge of front grill Fig 1 e To remove the front grill grasp the lower front corner of the grill pulling gently outward and upward Fig 3 Repeat this step on the 3 remaining corners e Before the front grill can be completely removed from the cabinet it will be necassary to disconnect the male female electrical wire harness located directly behind the front grill Fig 4 aa the two phillips screws lower left right side of cabinet securing the slide out chassis to the cabinet Fig 6 NOTE These screws must be reinstalled upon completion of the window installation to secure slide out chassis NOTE Some models may be inclusive of an additional slide out chassis retaining bracket and screw located at the front of the chassis This bracket and screw must also be removed before attempting to remove the slide out chassis Fig 5 Fig 4 i i e Grasp the pull handle at the front of the slide out chassis and carefully slide the air conditioner out of the cabinet Fig 5 Please seek assistance for this procedure i j H H i Left right side of cabinet screws 2a 3b Assembly of the Upper amp Lower Channels to Cabinet L Shaped Top Channel Install the L shaped channel to the top of the cabinet as shown in Fig 8 using four 4 1 4 6 4mm screws U Shaped Bottom Channel Install the U shaped channel to the bottom of the ca
17. he operation of the compressor i e Compressor off fan off Compressor on fan on NOTE When the ENERGY SAVER feature is not selected the fan motor operates continuously even after the compressor cooling mode has cycled off i e compressor on fan on compressor off fan on MODE Activates the FAN or COOLING mode TIMER Activates the auto start or auto stop timer program from 0 12 hours 1 hour increments ct ONE TOUCH Activates a factory pre set temperature setting of 22 C 2 C 71 6F 9 FAN Activates fan speed settings S high fan medium fan y low fan KEYPAD Activates increases temperature settings W KEYPAD Activates decreases temperature settings Control panel CAUTION Wait three minutes before adjusting changing temperature settings Adjusting temperatures too quickly may cause the compressor overload to trip resulting in a blown fuse Fresh Air Ventilation should be kept in the closed position during air conditioning mode Fresh Air Ventilation should be kept in the open position during fan mode only when clearing smoke and or odors from the room Fresh Air Ventilation Switch 10 OPERATING INSTRUCTIONS D POWER Press the POWER keypad to turn the unit on off A TEMPERATURE SETTINGS Press the up keypad to increase the set operating temperature of the air conditioner Each time the keypad is pressed the tem
18. ion run off Check the unit and make any adjustments When outdoor temperature is approximately 65 F or below frost may form when unit is in cooling mode Switch unit to FAN only operation until frost melts Remove and clean filter 1 If circuit breaker is tripped repeatedly or fuse is blown more than once contact a 2 When unit is installed using proper installation steps unit is properly tipped towards the outdoors to allow for condensation run off 13 SKS ORR Danby Q A by Ve LIMITED AIR CONDITIONER WARRANTY Q ss This quality product is warranted to be free from manufacturer s defects in material and workmanship provided that the unit is used under the normal operating ORK X pe CS oy conditions intended by the manufacturer H ZA This warranty is available only to the person to whom the unit was originally sold by Danby or by an authorized distributor of Danby and is non transferable PK D R KS TERMS OF WARRANTY we ey Plastic parts are warranted for thirty 30 days only from purchase date with no extensions provided Q Aa sits fed ORKE D First 12 Months During the first twelve 12 months any electrical parts of this product found to be defective including any sealed system units wil A be repaired or replaced at warrantor s option at no charge to the ORIGINAL purchaser ye x A amp To obtain Danby reserves the right to limit the boundaries of In Home Service to the proximit
19. it itself howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of the unit the gt SA x purchaser does hereby agree to indemnify and save harmless Danby Products Limited from any claim for damages to persons or property caused by the unit Q lt GENERAL PROVISIONS RR x No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following NS 1 Power Fail OX D Power Failure es XK 2 Damage in transit or when moving the appliance DA xy 3 Improper power supply such as low voltage defective house wiring or inadequate fuses NS 4 Accident alteration abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions es x extremely high or low room temperature gt 5 Use for commercial or industrial purposes ne 6 Fire water damage theft war riot hostility acts of God such as hurricanes floods etc SK gt 7 Service calls resulting in customer education xv Proof of purchase date will be required for warranty claims so please retain bills of sale In the event warranty service is required present this document to our es D AUTHORIZED SERVICE DEPOT NY N 3 ce ne re gt Warranty Service R X Carry in es S SAR Q SS Danby Products Limited Danby Products inc BAX gt PO Box 1778 5070 Whitelaw RD Guelph Ontario Canada NH 679 PO Box 66
20. llation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes DO NOT USE REGULAR EXTENSION CORDS WITH THIS UNIT If it is necessary to use an extension cord to connect your air conditioner use an approved air conditioner extension cord only available at most local hardware stores DO NOT install unit where leakage of combustible gas is suspected Your air conditioner may fail to operate in air containing oils including machine oils sulfide gas near hot springs etc Your unit is designed to evaporate condensation under normal conditions However under extreme humidity conditions excess condensation may cause basepan to overflow to the outside The Unit should be installed where condensation run off cannot drip on pedestrians or neighboring properties A drain tube connection excluding hose is provided to redirect condensation overflow See Fig 25 Fence wall or 30 76 2cm Min obstruction other lt D le Goid obstacle Fig 2 springs etc 1 Preparation to Remove the Air Conditioner Slide Out Chassis e Position the air conditioner in the normal upright position e Remove the air filter by grasping the filter handie on front grill and sliding it to the right Remove the phillips screw behind filter securing the grill front to the chassis Fig 3 e Remove the phillips screws located on t
21. nward on the outside If necessary re adjust the levelling screws in the support brackets 4d Cut the first foam sealing strip to fit the underside of the bottom window sash Remove the peel off backing on the foam and attach it to the sash See Fig 13 Window Sash Sealing Strip 5a Completing the Installation for All Models Carefully slide the air conditioner back into the cabinet in window please seek assistance for this procedure Reinstall slide out chassis security screws removed earlier on the lower left right side of the cabinet Fig 7 Expand the shutter frames fully on each side and secure the top of the frames to the window sash using one 3 4 19 1mm screw amp flat washer on eash side Fig 23 Install shutter clamp on each side of the lower shutter and secure to window sill using one 3 4 19 1mm screw amp flat washer on each side Fig 23 Reinstalling Front Panel Grill Position the front panel assembly on the cabinet starting at the top The front panel lock tabs must be inserted into the retaining slots in the cabinet Repeat this procedure on all sides making sure the fresh air ventilation lever arm and power cord are properly installed back to their original position Secure the front grill to the cabinet using the phillips screws removed earlier Fig s 1 amp 2 install the air filter Cut the second foam seal to fit the opening between the top of the inside and outsid
22. ors See Fig 12 3d Cut the 1st foam sealing strip to fit the underside of the bottom winsow sash Remove the peel off backing on the foam and attach it to the sash See Fig 13 1 4 6 4mm Screw L Shaped Channel Si DS ye Shaped U Shaped Channel Channel Position smaller space to front Shutter Frame 1 4 6 4mm Screw Fig 9 7 lic ee D T F 1 4 6 4mm Screw Al Bracket Assembly Levelling Screws Levelling Screws Bracket Fig 10 Leveling Screw Fig 11 Inside Window Sill 3 16 4 8mm Maximum t PS Leveling Screw Window Sash Bracket Assembly Sealing Strip 4 Installation of the Cabinet 4a Place the air conditioner cabinet into the window with the L shaped mounting channel on top positioned in front of the upper window sash The U shaped channel on the bottom of the L Shaped Foam Strip cabinet should be positioned in the recessed E Mounting portion of the track located at the front of the Channel window bracket assemblies Pull the window down until it rests just behind the front flange of the top L shaped mounting channel See Fig 14 4b Align one hole in the bottom of the cabinet with one hole in the bracket assembly Secure the cabinet to the bracket using a 1 4 6 4mm screw provided Repeat the same procedure on the opposite side of the cabinet See Fig 15 4c Check to make sure that the cabinet is slanted slightly dow
23. perature is increased as follows 2 F Farenheight Scale Maximum Setting 90 F 1 C Celsius Scale Maximum Setting 31 C W TEMPERATURE SETTINGS Press the down keypad to decrease the set operating temperature of the air conditioner Each time the keypad is pressed the temperature is decreased as follows 2 F Farenheight Scale Minimum Setting 60 F 1 C Celsius Scale Minimum Setting 16 C dh SWING Press the SWING keypad to activate the automatic air swing oscillation feature The green pilot fight adjac nt to the SWING keypad will illuminate identifying the selected mode is operational The vertical louvers will oscillate back and forth side to side automatically sweeping cold air alternately for comfortable cooling To stop the air swing feature press the SWING keypad again the green pilot light adjacent to the keypad will go off c8 ENERGY SAVER To activate the ENERGY SAVER feature press and hold the R SWING keypad for 3 seconds The green pilot light directly above the ENERGY SAVER mode will illuminate identfying the selected mode is operational The ENERGY SAVER program helps to reduce energy electricity consumption by controlling limiting operation of the fan motor with the operation cycles of the compressor i e compressor off fan off compressor on fan on If the ENERGY SAVER feature is not activated the fan will operate continuously even after the compressor has cycled off i
24. rgy Efficiency Rating EER 10 7 Fan Cooling Speeds 3 3 Cooling Area Coverage 175Sq ft 16 3m Noise Level dB 54 Unit Dimensions Width 17 75 45 1cm Depth 16 40 6cm Height 12 75 32 4cm Window Kit Dimensions Maximum Width 38 96 5cm Minimum Width 21 5 54 6cm Minimum Height 14 5 36 8cm Shipping Weight 65ib 29 5Kg NOTE Specifications are subject to change without notice for further improvement 2 Electrical Specifications 1 All wiring must comply with local and national electrical codes and must be installed by a qualified electrician If you have any questions regarding the following instructions contact a qualified electrician 2 Check available power supply and resolve any wiring problems BEFORE installing and operating this unit 3 This 115V air conditioner uses 12 0 or less nameplate amps and may be used in any properly wired general purpose household receptacle See Table 1 for specifications for individual branch circuit 4 For your safety and protection this unit is grounded through the power cord plug when plugged into into a matching wail outlet If you are not sure whether your wall outiet is properly grounded please consult a qualified electrician 5 The wall outlet 3 pin must match the plug 3 pin on the service cord supplied with the unit DO NOT use plug adapters See Table 2 for receptacle and fuse information If it is necessary to use an extension cor
25. y of an Authorized Service Depot Any appliance Q x Service requiring service outside the limited boundaries of In Home Service it will be the consumer s responsibility to transport the appliance at Q S their own expense to the original retailer point of purchase or a service depot for repair Contact your dealer from whom your unit was SCA o purchased or contact your nearest authorized Danby service depot where service must be performed by a qualified service technician K If service is performed on the units by anyone other than an authorized service depot or the unit is used for commercial application all ONG amp obligations of Danby under this warranty shall be at an end amp KS AG Oe Q 4 Ae ORR D a N EXCLUSIONS es x Save as herein provided Danby Products Limited Canada or Danby Products Inc U S A there are no other warranties conditions representations or S Z S SN guarantees express or implied made or intended by Danby Products Limited or its authorized distributors and ali other warranties conditions representations or Oy 9 guarantees including any warranties conditions representations or guarantees under any Sale of Goods Act or like legislation or statue is hereby expressly 69 ue KX N excluded Save as herein provided Danby Products Limited Canada or Danby Products Inc U S A shall not be responsible for any damages to persons or amp property including the un
Download Pdf Manuals
Related Search
Related Contents
DE Bedienungsanleitung Winkelschleifer 125 mm GB Instruction Ariete 446 Under Sink RO User Manual fof pdf 5.System Settings Manual de instalación, puesta en marcha y mantenimiento WPI Robotics Library User`s Guide FascicoloInformazioneFormazione2012 ウインドシールド(UV010Y) 組付・取扱説明書 AoC Admin User Manual - Department of Computer and Information Copyright © All rights reserved.