Home
CFM FCU-15 User's Manual
Contents
1. F 2 a F2 FOUNDATION LAYOUT pias D we V DIA Y HOLES 5 8 p Y BASE DETAIL SIZES 8 9 amp 11 DIMENSIONS IN INCHES TH DB BH UB STRAIGHT DISCHARGE BAU TAU TAD BAD ANGULAR DISCHARGE H J K L DO NOT USE FOR CONSTRUCTION H J K L 20 1 38 8 0 2 2 208 43 90 2 8 21 5 5 1 10 0 i 3 5 239 64 13 3 244 70 14 5 200 ico 16 1 27 5 85 179 We 9i 10E 31 5 10 0 21 5 02000299 33 6 11 8 26 4 145T 145T 145T 182T 182T 182T 184T 184T 213T 213T 215T CONSULT FACTORY FOR CERTIFIED PRINTS FCU UTILITY FANS MODEL FCU 08 CFM Outlet Vel FPM 0 25 SP 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP 1 25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP MODEL FCU 08 CFM Outlet Vel FPM 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP 3 50 SP 4 00 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2969 2982 3002 1 15 1 24 1 34 Tip Speed FPM 1 996 x RPM Outlet Inlet 296 sq ft inside 8 25 x 5 38 outside 338 sq ft inside 8 dia outside Wheel Diameter Max RPM LL 3006 Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Performance ratings do not include the effects of appurtenances i
2. x 11 75 outside 1 374 sq ft inside 16 13 dia outside to 1400 Wheel Diameter Max RPM Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Performance ratings do not include the effects of appurtenances in the airstream 8 CFM Outlet Vel FPM 0 25 SP FCU UTILITY FANS MODEL FCU 16 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP 1 25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP MODEL FCU 16 CFM Outlet Vel 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP 3 50 SP 4 00 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Tip Speed FPM 4 189 x RPM Outlet Inlet 1 560 sa ft inside 17 75 x 13 outside 1 67 sq ft inside 17 88 dia outside Wheel Diameter Max RPM 16 25 1313 Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Performance ratings do not include the effects of appurtenances in the airstream 9 MODEL FCU 18 CFM Outlet Vel FPM 0 25 SP FCU UTILITY FANS 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP MOD
3. CFM CONTINENTAL FAN CENTRIFUGAL FANS amp BLOWERS better AIRFLOW by DESIGN FCU UTILITY FANS Forward curved impeller Heavy guage steel construction Discharge rotatable to 8 positions CW amp CCW rotation e AMCA Type A B amp C construction available e Arrangement 10 SWSI Class I Sizes range from 8 to 24 Capacities from 237 to 20 056 cfm Custom Fan Solutions FCU UTILITY FANS STANDARD FEATURES amp BENEFITS e Heavy gauge rugged welded steel construction e Forward curved impeller e Self aligning pillow block bearings v Standard bearings have 100 000 hours average life e CW amp CCW rotation e Discharge rotatable to 8 positions e Rigid circular stamped inlet ring e Adjustable V belt drive e TEFC industrial duty motor e AMCA Class construction ACCESSORIES OPTIONS Belt guard g e Drain fitting e Heat slinger e e Weather cover drive cover e Inlet amp discharge screen e AMCA Type A B amp C construction Flanged inlets amp outlets Protective coatings Automatic discharge shutter Inspection doors bolted or quick opening Vibration rail base spring rail or RIS rail Explosion proof amp special duty motors ARRANGEMENT 10 SWSI CLASS Note e Letters C and D are outside housing dimensions e C dimension extends beyond centerline size 8 5 16 size 9 1 9 16 amp size 1 1 1 1 16 V DIA 6 HOLES
4. RPM BHP RPM BHP 2 37 Tip Speed FPM 2 782 x RPM Outlet Inlet 636 sq ft inside 11 75 x 8 outside 525 sq ft inside 10 dia outside Wheel Diameter Max RPM 10 5 2197 Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Performance ratings do not include the effects of appurtenances in the airstream 5 FCU UTILITY FANS MODEL FCU 12 CFM Outlet Vel FPM 0 25 SP 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP 1 25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP MODEL FCU 12 CFM Outlet Vel FPM 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP 3 50 SP 4 00 SP 4 50 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Tip Speed FPM 3 27 x RPM Outlet Inlet 858 sq ft inside 13 25 x 9 63 outside 921 sq ft inside 13 25 dia outside Wheel Diameter Max RPM 12 25 1871 Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Performance ratings do not include the effects of appurtenances in the airstream 6 FCU UTILITY FANS MODEL FCU 13 CFM Outlet Vel FPM 0 25
5. 17290 Tip Speed FPM 6 414 x RPM Outlet 3 458 sq ft inside 26 25 x 19 25 outside Wheel Diameter 24 5 Inlet 3 650 sq ft inside 26 38 dia outside Max RPM 779 Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Performance ratings do not include the effects of appurtenances in the airstream 13 FCU UTILITY FANS DESIGNATIONS FOR ROTATION amp DISCHARGE CW ROTATION TH DB BH UB CLOCKWISE CLOCKWISE CLOCKWISE CLOCKWISE BAU TAU TAD BAD CLOCKWISE CLOCKWISE CLOCKWISE CLOCKWISE CCW ROTATION TH DB BH UB COUNTER CLOCKUWISE COUNTER CLOCKUWISE COUNTER CLOCKUWISE COUNTER CLOCKUWISE BAU TAU TAD BAD COUNTER CLOCKUWISE COUNTER CLOCKUWISE COUNTER CLOCKUWISE COUNTER CLOCKUWISE Note 1 Direction of rotation is determined from drive side of fan 2 On single inlet fans drive side is always considered as the side opposite fan inlet 14 FCU UTILITY FANS PRODUCT SPECIFICATION GUIDE 1 0 GENERAL 2 0 3 0 4 0 9 0 A Fans shall be model FCU as manufactured by Continental Fan Manufacturing Inc of Buffalo NY and of the size capacity and rotation as indicated on the drawings and fan schedule B Fans shall be single width single inlet arrangement 10 class I C Fans shall be rated and tested in accordance with ANSI AMCA Standard 210 99 D All motors and electrical compo
6. EL FCU 18 CFM Outlet Vel 1 25 SP 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Tip Speed FPM 4 712 x RPM Outlet Inlet 1 899 sq ft inside 19 63 x 14 25 outside 2 02 sq ft inside 19 63 dia outside Wheel Diameter Max RPM 18 25 1061 Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Performance ratings do not include the effects of appurtenances in the airstream 10 FCU UTILITY FANS MODEL FCU 20 CFM Outlet Vel 0 25 SP 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP MODEL FCU 20 CFM Outlet Vel 1 25 SP 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP 3 50 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3474 3706 3937 4169 4400 4632 5095 941 5 93 5558 947 6 50 6022 6485 6948 7411 7875 8338 8801 9264 9727 10190 10654 Tip Speed FPM 5 236 x RPM Outlet 2 316 sq ft inside 21 5 x 15 88 outside Wheel Diameter 20 Inlet 2 435 sq ft inside 21 5 dia outside Max RPM 955 Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Perfo
7. SP 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP 1 25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP MODEL FCU 13 CFM Outlet Vel 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP 3 50 SP 4 00 SP 4 50 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Tip Speed FPM 3 534 x RPM Outlet Inlet 1 049 sq ft inside 14 63 x 10 75 outside 1 108 sq ft inside 14 50 dia outside Wheel Diameter Max RPM 13 5 1698 Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Performance ratings do not include the effects of appurtenances in the airstream 7 CFM Outlet Vel FPM 0 25 SP FCU UTILITY FANS MODEL FCU 15 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP 1 25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP MODEL FCU 15 CFM Outlet Vel 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP 3 50 SP 4 00 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Tip Speed FPM 3 927 x RPM Outlet Inlet 1 280 sq ft inside 16 25
8. ease fittings Bearings shall be 100 000 hours average life OPTIONAL FAN ACCESSORIES A Where indicated fans shall be provided with the following optional accessories e Belt guard e Drain fitting e Heat slinger e Weather cover drive cover e Inlet amp discharge screen e Flanged inlet amp outlet e Protective coating e Automatic discharge shutter e Inspection door bolted or quick opening e Vibration rail base spring rail or RIS rail e AMCA Type A B or C construction e Motor Explosion proof Special duty 6 0 FAN TESTING A B Forward curved centrifugal impeller shall be balanced and mounted in fan assembly Fan assembly shall be run tested prior to shipment C A test report shall be maintained on file for each individual fan 15 Industrial Fan Division The Industrial Fan Division offers superbly crafted industrial fans and ventilators expertly supported by a network of independent manufacturers representatives Panel Centrifugal Flange In line Roof Iris Fans Fans Fans Fans Ventilators Dampers OEM Fan Division The OEM Fan Division works closely with original equipment manufacturers to meet their design requirements offering in stock fan components 3D models and custom fan solutions 3 ition a Ak AN Cabinet Cooling Motorized Motorized Centrifugal Axial Centrifugal Fans Axials Impellers Fans Impellers Impellers Wholesale Products Division The Wholesale Product
9. n the airstream 3 FCU UTILITY FANS MODEL FCU 09 CFM Outlet Vel FPM 0 25 SP 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP 1 25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP MODEL FCU 09 CFM Outlet Vel FPM 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP 3 50 SP 4 00 SP 4 50 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2516 2530 1 61 1 78 Tip Speed FPM 2 356 x RPM Outlet Inlet 468 sq ft inside 10 75 x 6 5 outside 406 sq ft inside 9 dia outside Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Performance ratings do not include the effects of appurtenances in the airstream 4 Wheel Diameter Max RPM 9 2547 FCU UTILITY FANS MODEL FCU 11 CFM Outlet Vel FPM 0 25 SP 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP 1 25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP CFM Outlet Vel 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP 3 50 SP 4 00 SP MODEL FCU 11 4 50 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
10. nents shall conform to NEMA standards FAN HOUSING A Fan housing and motor base shall be constructed of heavy gauge steel B Fan housing shall be welded and bolted steel components C Fan housing shall be coated with baked polyester powder coat finish D Fan housing shall be capable of field rotation to any of 8 positions E Motor base shall be constructed of welded steel components F Motor base shall be coated with baked polyester powder coat finish G Inlet cone shall be of rigid circular stamped steel material and shall be coated with baked polyester powder coat finish FAN IMPELLER A B C Centrifugal impeller shall be forward curved die formed blades machine riveted to die punched back plate and rim Forward curved centrifugal impeller and inlet cone shall be factory matched for superior performance Forward curved centrifugal impeller hub shall be keyed directly to the solid steel drive shaft FAN MOTOR AND DRIVE T MODQOD gt D Motor shall be TEFC industrial duty and conform to NEMA standards Motor shall be of voltage horsepower RPM and enclosure as indicated on the fan schedule The fan sheaves shall be cast iron adjustable pitch appropriately sized and aligned The fan belts shall be static conducting plus oil and heat resistant The fan shaft shall be steel turned ground and polished The fan shaft bearings shall be lubricated self aligning ball type in cast iron pillow block mounts with external gr
11. rmance ratings do not include the effects of appurtenances in the airstream 11 FCU UTILITY FANS MODEL FCU 22 CFM Outlet Vel 0 25 SP 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP MODEL FCU 22 CFM Outlet Vel 1 25 SP 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 4806 5089 5371 5654 6219 6785 7350 7916 8481 9046 9612 10177 10743 11308 11873 12439 13004 13570 Tip Speed FPM 5 236 x RPM Outlet 2 827 sq ft inside 24 x 17 38 outside Wheel Diameter 22 5 Inlet 3 015 sq ft inside 23 88 dia outside Max RPM 858 Performance shown is for installation Type B free inlet ducted outlet Power rating BHP does not include drive losses Performance ratings do not include the effects of appurtenances in the airstream 12 FCU UTILITY FANS MODEL FCU 24 CFM Outlet Vel 0 25 SP 0 375 SP 0 50 SP 0 625 SP 0 75 SP 0 875 SP 1 00 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP MODEL FCU 24 CFM Outlet Vel 1 25 SP 1 50 SP 1 75 SP 2 00 SP 2 50 SP 3 00 SP 3 50 SP FPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 5187 5533 5879 6224 6570 6916 7608 8299 8991 9682 10374 11066 11757 12449 13140 13832 14524 15215 15907 16598
12. s Division offers a superior line of in stock commercial and residential ventilation products available from wholesalers and distributors across North America Bathroom Air Purification In Line External Radial Blade Exhaust Fans Systems Duct Fans Mount Fans Blowers Fans USA www continentalfan com Canada www aeroflo com Continental Fan Manufacturing Inc Aeroflo Inc 203 Eggert Road Buffalo NY 14215 12 205 Matheson Blvd E Mississauga ON lUZ 3E3 Tel 7 16 842 0670 Fax 7 16 842 0611 Tel 905 890 6 192 Fex 905 890 6193 FCU UTILITY FANS FCU W 1004
Download Pdf Manuals
Related Search
Related Contents
陸 上 自 衛 隊 仕 様 書 FL_101 USER MANUAL Samsung Микроволновая печь Соло Samsung RSG307AARS User Manual(Installation Guide included) LEYBOLD DIDACTIC GMBH Mode d`emploi 532 14 Instrucciones de Manual TV PH32E32D Pulgón amarillo - Comité Estatal de Sanidad Vegetal de Sonora Xcom-SMS User manual 五所川原市開発指導要綱(PDF/434KB) Copyright © All rights reserved.