Home
BRK electronic CO5120BN User's Manual
Contents
1. THE PROFESSIONAL STANDARD 120V AC 60Hz Wire in C05 120BN with 9V Battery Backup The BRK Brands Inc Cat No C05120BN is a wire in 120 VAC 60Hz single and ee or multiple station carbon monoxide alarm specifically designed for residential ia and institutional applications including sleeping rooms of hospitals hotels ELECTROCHEMICAL motels dormitories and other multi family dwellings as defined in standard NFPA 101 Model CO5120BN complies with UL2034 NFPA 720 HUD FHA and other co SENSOR agencies that model their codes after the above agencies They meet building Most accurate technology available for codes where AC DC carbon monoxide alarms are required either separately or in detecting carbon monoxide as compared to combination The alarms are interconnectable up to 18 devices of which 12 can be smoke alarms other sensing technologies The BRK C05120BN features an electrochemical carbon monoxide sensor an LATCHING ALARM 85dB horn 9V battery back up and a silence feature Intelligent Sensing Technology is designed to reduce nuisance alarms Latching Alarm Indicator INDICATOR remembers which unit initiated an alarm When interconnected in a series the Remembers which unit initiated an alarm unit that triggered the alarm will store in memory or latch the information and begin to flash the LED indicator 2 seconds on 2 seconds off A single button test silence button eliminates confusion Battery insta
2. do not permit be sure the neutral wire is common to both phases THE PARTS OF THIS CO ALARM Mounting bracket Mounting Slots Locking Pins Hot Black AC Wire Nuetral White AC Wire Interconnect Orange Wire Battery Drawer Latch Battery Drawer Install 9V battery here r oam am am ar a r a o NOn eee gt e H on o Quick Connect Plug HAW oT ATT A Unswitched 120VAC 60 Hz source B To additional units Maximum 18 total Maximum 12 Smoke Alarms 5 Junction Box 6 Neutral Wire White 1 CO Alarm 2 Ceiling or Wall 3 Power Connector 4 Wire Nut 8 Hot Wire Black 7 Interconnect Wire Orange BATTERY DRAWER LOCK Remove Pin BRK THE PROFESSIONAL STANDARD brkelectronics com Push locking pin through hole near battery drawer on the back of the alarm 2009 BRK Brands Inc a Jarden Corporation Company NYSE JAH 3901 Liberty Street Road Aurora IL 60504 8122 All rights reserved First Alert is a registered trademark of the First Alert Trust eek registered trademark of BRK Brands Inc
3. 1 9 H 6 4 oz 120V AC 60Hz w 9V battery backup 09 amps standby alarm 40 F 4 C to 100 F 38 C 10 to 95 relative humidity RH 85dB at 10 feet Electronically simulates carbon monoxide condition causing the unit to alarm Press and hold test silence button Automatic when CO clears Up to 18 units of First Alert or BRK Smoke CO and Heat Alarms Maximum of 12 smoke alarms See user s manual for details Electrochemical Constant Green LED Intermittent Green LED Red LED flashes rapidly Red LED out Red LED flashes every 5 seconds after local alarm stops Listed to UL2034 Standard Individual Carton Dimensions Weight Cube UPC Master Carton Dimensions Master Pack Weight Cube 20f5 Pallet Information Cases per Layer Number of Layers Cases per Pallet Units per pallet Cube Weight 5 54 L x 2 10 W x 5 72 H 0 61 Ibs 0 038 ft3 0 29054 85617 3 13 13 L x 5 81 W x 12 13 H 12 9 2 Ibs 0 54 ft3 300 29054 85617 4 25 3 75 900 47 3 ft3 758 Ibs Installation of this carbon monoxide alarm must conform to all B local electrical codes and Article 760 of the National Electrical Code NFPA 70 and NFPA 720 Interconnected units must meet pi the following requirements Total length of wire interconnecting units should be less than 1000 feet be 18 gauge or larger and be rated at least 300V It is recommended that all units be on the same fuse or circuit breaker If local codes
4. f the unit malfunctions Avisual LED power on indicator to confirm unit is receiving power or to confirm unit has switched to battery backup mode The CO sensor is adjusted not to detect CO levels below 30 PPM and will not alarm when exposed to constant levels of 30 PPM for 30 days It will alarm at the following levels 400 PPM CO between 4 and 15 minutes 150 PPM CO between 10 and 50 minutes and 70 PPM CO between 60 and 240 minutes Atest silence button to check all alarm functions and to silence any nuisance alarms In addition the unit shall have a low battery silence feature to quiet the low battery chirp for up to eight hours A Smart Interconnect feature allows the unit to be interconnected to BRK smoke alarms During a smoke event the C05120BN horn pattern shall emit the smoke alarm horn pattern 3 beeps pause 3 beeps pause During a CO event the interconnected CO alarms sound their normal horn pattern The unit shall be capable of operating between 40 F 4 C and 100 F 38 C and relative humidity between 10 and 95 The unit shall ata minimum meet the requirements of UL2034 NFPA 720 and ICC Alarm Dimensions Weight Operating Voltage Operating Current Temperature Range Humidity Range Audio Alarm Test Silence Alarm Reset Interconnections CO Sensor Indicator Lights Sounds AC Power DC Power Local Alarm Remote Alarm Latching Alarm Listing 5 4 dia x
5. llation and removal can INTELLIGENT SENSING occur while the unit is mounted to the ceiling or wall via the side load battery TECHNOLOGY compartment Other Contractor Preferred features include a dust cover to keep alarm clean during construction keyhole slots in the mounting bracket eliminate Microprocessor controlled to reduce the need to remove the electrical box screws for installation Two locking the number nuisance alarms features are provided to prevent battery theft and or theft of the unit Connection toAC power is made with a Quick Connect wiring harness Installation is quick easy and cost effective TWO LOCKING FEATURES Pins lock battery drawer and or alarm to base Perfect for apartment dormitory or hotel applications pier gt E ir Ss WOR ns hnn A LEN RNS w Ti oe i e cla O h i EA 1S i ai A e e NRE wt Listed to it MOVE TO a ae UL 2034 05120BN TOP VIEW MOUNTING 7 SIDE VIEW BRACKET 1 9 The carbon monoxide alarm shall be a BRK Model CO5120BN and shall provide at a minimum the following features and functions 1 2 An electrochemical CO sensor Powered by 120V AC 60Hz and have a monitored 9V battery backup and a solid State piezo horn rated at 85dB at 10 ft and shall be capable of self restoring The unit shall perform self diagnostic tests and issue a malfunction warning audibly three chirps i