Home

Black Box KVT128AE-UK-8-R2 User's Manual

image

Contents

1. BLACK BOX ServView 17S KVM Switch Quick Start Guide NETWORK SERVICES Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock Only qualified service personnel should open the chassis Opening it yourself could damage the equipment and invalidate its warranty If any part of the equipment becomes damaged or stops functioning have it checked by qualified service personnel Regulatory Notices Federal Communications Commission FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Any changes or modifications made to this equipment may void the user s authority to operate this equipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following meas
2. Call the KVM OSD menu by entering the KVM hotkey Scroll Lock Scroll Lock Space Bar Enter F1 to view the MAIN MENU Select USER SECURITY Set password in SUPERVISOR amp USER level a In the top left row S SUPERVISOR press Enter to set your own user name amp password b In the row 1 to 8 USER press Enter to set your own user name amp password 6 Press Enter to save the settings or press Esc to cancel without saving Note a Blank has an underscore while SPACE does not b Enter any alphanumeric key to move to next input item SPACE is treated as a valid character See ws Change your password Login to the KVM switch in SUPERVISOR level by entering your own user name amp password Call the KVM OSD menu by entering the KVM hotkey Scroll Lock Scroll Lock Space Bar Press F1 to view the MAIN MENU Select USER SECURITY Change the password in SUPERVISOR amp USER level a In the top left row S SUPERVISOR press Enter to change your user name amp password b In the row 1 to 8 USER press Enter to change your user name amp password 6 Press Enter to save the setting or press Esc to cancel without saving Note a Blank has underscore while SPACE does not b Enter any alphanumeric key to move to next input item SPACE is treated as a valid character Oe T m Enable password 1 Enter the KVM hotkey Scroll Lock Scroll Lock U 2 Logout of the KVM switch by entering the KVM hot
3. hotkey within 2 seconds m A beep sound will be heard once the hotkey had been successfully entered m The numerical keypad is not supported by the OSD The arrow keys PgUp PgDn and Enter keys are supported E 6 lt BLACK BOX ServView 17S KVM Switch Quick Start Guide Remote Console Hotkey Hotkey Caps Lock Caps Lock F1 Caps Lock Caps Lock F2 Caps Lock Caps Lock C Caps Lock Caps Lock Q Caps Lock Caps Lock S Caps Lock Caps Lock A Function Calls the Help OSD windows Select Hotkey Default is Caps Lock Toggle the switch between remote amp local port Turn the buzzer ON amp OFF By default the buzzer is ON Activate auto scan mode for remote amp local port The scan time interval is 5 seconds Auto adjust the video signal BLACK BOX Customer Support Information FREE tech support 24 hours a day 7 days a week Call 0118 965 6000 Address Black Box Network Services UK Ltd 464 Basingstoke Road Reading Berkshire RG2 OBG Web www blackbox co uk E mail info blackbox co uk Copyright 2007 Black Box Corporation All rights reserved
4. however no guarantee is given to the correctness of the contents The information in this document is subject to change without notice We are not liable for any injury or loss that results from the use of this equipment Safety Instructions Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth m Keep equipment away from excessive humidity and heat Preferably keep it in an air conditioned environment with temperatures not exceeding 40 Celsius 104 Fahrenheit m When installing place the equipment on a sturdy level surface to prevent it from accidentally falling and causing damage to other equipment or injury to persons nearby When the drawer is in an open position do not cover block or in any way obstruct the gap between it and the power supply Proper air convection is necessary to keep it from overheating Arrange the equipment s power cord in such a way that others won t trip or fall over it If you are using a power cord that didn t ship with the equipment ensure that it is rated for the voltage and current labeled on the equipment s electrical ratings label The voltage rating on the cord should be higher than the one listed on the equipment s ratings label Observe all precautions and warnings attached to the equipment m If you don t intend on using the equipment for a long time disconnect it from the power outlet to prevent being damaged by transient over voltage
5. ServView 17S KUM Switch Quick Start Guide lt gt BLACK BOX E E KVT128AE UK 16 R2 NETWORK SERVICES lt BLACK BOX ServView 17S KVM Switch Quick Start Guide CONTENTS Chapter 1 Getting Started Chapter 2 1 1 Important Safeguards 1 2 Regulatory Notice 1 3 Before Installation How to use your CAT5 KVM Switch 2 1 Password 2 2 KVM OSD 2 3 KVM Hotkey 4 5 6 7 BLACK BOX ServView 17S KVM Switch Quick Start Guide NETWORK SERVICES 1 1 Important Safeguards Please read all of these instructions carefully before you use the device Save this manual for future reference What the warranty does NOT cover Any product on which the serial number has been defaced modified or removed m Damage deterioration or malfunction resulting from Accident misuse neglect fire water lightning or other acts of nature unauthorised product modification or failure to follow instructions supplied with the product Repair or attempted repair by anyone not authorised by us Any damage of the product due to shipment Removal or installation of the product Causes external to the product such as electric power fluctuation or failure Use of supplies or parts not meeting our specifications Normal wear and tear Any other causes which does not relate to a product defect 1 2 Regulatory Notice Legal Information Information in this document has been carefully checked for accuracy
6. display time interval 08 OSD MOUSE Modify OSD mouse speed BOX ServView 17S KVM Switch Quick Start Guide NETWORK SERVICES 2 3 KVM Hotkey Local Console Hotkey Hotkey Function Scroll Lock Scroll Lock Space Bar Calling OSD menu Right button mouse Esc Calling OSD menu Scroll Lock Scroll Lock Switch to previous port Scroll Lock Scroll Lock Switch to next port Scroll Lock Scroll Lock PgUp PgDown Switch to previous bank or next bank Scroll Lock Scroll Lock Bank no Port no Switch to specific port Turn the buzzer ON and OFF Scroll Lock Scroll Lock B Default he buzzer amp ON Logout the KVM if password security is ON Show Scroll Lock Scroll Lock P p therstatus windows Adavanced hotkeys for Supervisor login only Activate auto scan mode for connected servers Scroll Lock Scroll Lock S Enter any key to exit the auto scan mode Reset all the KVM settings to factory default Scroll Lock Scroll Lock R Except User Security settings Disable and enable password security Scroll Lock Scroll Lock U Default security is OFF To enable disable the screen saving function and 10 Scroll Lock Scroll Lock L mingtes ants logout Example m Scroll Lock Scroll Lock Bank no Port no Bank no 1 to 8 Port no 01 to 16 e g Bank 1 Port 4 Scroll Lock Scroll Lock 1 0 4 e g Bank 2 Port 16 Scroll Lock Scroll Lock 2 1 6 m You must enter the
7. key Scroll Lock Scroll Lock P 3 Following this you will not need a user name amp password to access the KVM OSD menu Forget your password 1 Please contact Black Box for further support Note m You must enter the KVM hotkey within 2 seconds m A beep sound will be heard once you have successfully entered the hotkey 3 BLACK BOX TWORK SERVICES ServView 17S KVM Switch Quick Start Guide 2 2 KVM OSD OSD Menu PORT NAME 02 03 Od 05 06 oT 08 OSD operation yt next to the system name amp J next to the system name F1 F2 F3 Esc Enter t PageUp PageDown 1 2 3 4 F1 Main Menu MAIN MENU SELECT OPTION PORT NAME EDIT PORT SEARCH USER SECURITY ACCESS LIST HOTKEY TIME SETTINGS O5D MOUSE 02 03 oa 05 06 or 08 USER SUPERVISOR SCAN TIME 10 SEC The PC is powered on The PC is selected Access F1 MAIN MENU Logout the OSD menu Previous menu Cancel Quit Complete Switch to selected port Switch to previous or next port SWitch to previous bank or next bank Display port 01 08 09 16 17 24 25 32 Note Display port 17 32 for 32 port model only BLACK BOX ServView 17S KVM Switch Quick Start Guide WORK SERVIC 01 LANGUAGE OSD language change 02 PORT NAME EDIT Define port name 03 PORT SEARCH Quick searching by port name 04 USER SECURITY Change password 05 ACCESS LIST Define user access authority 06 HOTKEY Change hotkey 07 TIME SETTINGS Modify scan
8. ures Re position or relocate the receiving antenna m Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 1 3 Before Installation m It is very important to locate the KVM in a suitable environment The surface for locating and fixing the KVM switch should be stable and level or mounted into a suitable cabinet Make sure the place has good ventilation is out of direct sunlight and away from sources of excessive dust dirt heat water moisture and vibration Position LCD Keyboard Drawer with respect to related facilities ServView 17S KVM Switch Quick Start Guide NETWORK SERVICES 2 1 Password The password is disabled by default i e There is no password required when you power on the KVM switch for the first time m Enable password 1 Enter the KVM hotkey Scroll Lock Scroll Lock U 2 Logout of the KVM switch by entering the hotkey Scroll Lock Scroll Lock P 3 In SUPERVISOR level enter 00000000 eight zeros in the user name amp password field Do not use the 0 on the number pad 4 In USER level enter Space bar Enter in the user name amp password field Note Automatic logout after 10 minutes of inactivity m Set your own user name amp password 1 Login to the KVM switch in SUPERVISOR level by entering 00000000 eight zeros in user name amp password field