1. Europe Middle East and Africa 33 4 92 96 15 83 Asia Pacific 61 2 9927 8822 Tokyo and Japan 81 3 5402 7041 viii 301894 B Rev 00 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes This document lists the anomalies also referred to as bugs change requests or CRs that have been fixed in Bay Networks BayRS Version 12 02 and Site Manager Software Version 6 02 BayRS Version 12 02 includes all anomalies that were fixed in 12 01 Revisions 1 2 and 3 Site Manager Software Version 6 02 includes all anomalies that were fixed in 6 01 Revisions 1 and 3 Use the BayRS Version 12 00 and Site Manager Software Version 6 00 documentation with BayRS Version 12 02 and Site Manager Software Version 6 02 Maintenance Release Methodology BayRS Version 12 02 and Site Manager Software Version 6 02 are Maintenance Releases Bay Networks is introducing a new methodology for releasing Bay Networks routing software Maintenance Releases are designated by a change in the second number to the right of the decimal point They provide a collection of software bug fixes for the current Major Release No new software or hardware features or functionality for either software or hardware is introduced beyond that already contained in the current Major Release 301894 B Rev 00 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes A Maintenance Release will occur ap
2. CR 71443 IPX A problem occurs in which the router experiences a bus error when a host sends a RIP request or SAP request using a source socket of 9001 NLSP CR 71475 ISDN For an ISDN leased line media type the inter frame fill pattern should be 7E instead of FF CR 71634 IPEX When IPEX in gateway mode is operational the router exceeds buffer space when many TCP sessions are torn down because the TCP server is disabled When you restart the server the IPEX TCP sessions do not re establish CR 71703 IPEX When you request IPEX configured in gateway mode to bring up many TCP sessions the router takes too long to process all the TCP open requests causing the peer to time out some of the open requests CR 71738 IP A configuration with multiple BGP regular expressions may cause the log to be filled with Truncating regular expression warning messages However the processing of the regular expression was not affected CR 71739 IP The ip bgp_routes N command may display routes that are not really being announced 301894 B Rev 00 35 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 71767 AppleTalk A problem occurs in AppleTalk in which an ARE interface can experience VBM errors This problem can occur in an environment in which there is a variety of extended networks and non extended networks CR 71779 IPX IPX route filters fail to work properly if you configure multip
3. When you attempt to configure traps on a token ring interface that interface is not available in Available Entities CR 73066 TCP The delete confirmation windows for Telnet server and Telnet client contain a typo 40 301894 B Rev 00 Release Notes CR 71347 DLSw When you configure an 802 5 service record for DLS LLC SRB Site Manager incorrectly sets the DLS DLC type wfDIsInterfaceEntry wfDIsInterfaceDlcType to 3 learning bridge the DLS DLC type should be set to 2 source route CR 36017 Image Builder If you are using Image Builder in Site Manager Software Version 6 01 to modify a Router Software Version 11 03 router image the following error message appears The cross referenced file is not up to date relative to the imag stamp CR 72567 DLSw When you configure DLSw Site Manager sets the TCP max window size to 1 wfTcp 18 0 1 The value should be set to the same value for which wfDIsTepWindowSize is configured CR 71137 DLSw When you add DLSw to an X 25 QLLC service record Site Manager displays the following error message Data entered for null is inconsistent with the packet level Do you want the related packet service record attributes set correctly When you click on the Apply button Site Manager core dumps or GPFs CR 35781 DLSw If the router is running pre BayRS 12 00 router code the DLSw Backup Peer MIB attributes on the DLSw Peer Configuration window are i
4. CR 33969 OSI Disabling the OSI interface will cause a fault in mib_ent c on another OSI slot CR 74815 ATM A watchdog error may occur when you process LE_ARPs on an ATM interface 301894 B Rev 00 Release Notes CR 72794 Technician Interface Disabling a multiline multilink circuit group via the script disable sync circuit lt cct name gt does not disable the entire group This command disables only the first circuit configured in this bundle subsequently you must disable the other lines manually CR 74301 Technician Interface Log and dir displays show year as only 2 digits should display as 4 digits CR 75352 NAT NAT stops translating traffic from the global port to the local port for random dynamic mappings Instead ICMP redirects are transmitted out the global port CR 76040 WCP Bouncing a Frame Relay PVC that has WCP enabled may cause a bus error CR 78737 SDLC An SDLC link configured as primary multi drop fails to respond after receiving an I Frame with the poll bit set If there are 2 PUs one of them must be inactive on the host for this condition to occur The router should send either another I Frame or RR CR 78787 IPEX IPEX Gateway does not respond to the Reset Request Cause 0 and Diag 0 CR 26530 MIB The MIB II variable ifEntry reports incorrect information for ifOperStatus for a redundant interface CR 75239 78321 BGP When you have more than one BGP peer between a pair of routers
5. FEP fails the router continues to poll the controller This prevents the customer from configuring another FEP to call the IPLS CR 34159 IP A router faults with a watchdog restart when it receives an IP frame that contains a TTL set to 1 IP options of 00 no options and 3 bytes of padding to terminate the IP header CR 34226 IP When you enable the IP Extended Filter Support parameter wfIpBase 20 0 filters that forward to the next hop address do not work correctly resulting in an error CR 34254 DLSw The log message for a negative CAPx message shows an offset of 0 for certain CAPXx errors CR 34258 IP This is an enhancement request provide the ability to display the total number of IP routes per slot for all slots Use the command ip routes O s where is the slot number If you do not enter a slot number all slots are displayed CR 34264 DLSw In an environment using DLSw 1795 with SDLC PU type 2 0 attached devices when one router sends a flow control reset to another router the second router still sends one more frame The first router receives the packet and issues a Halt DL 26 301894 B Rev 00 Release Notes CR 34272 Technician Interface This is an enhancement request to increase the severity level of the message tf_validate header size invalid Object 1 18 3 5 1 4 3 1 Instance 29 1 1 to WARNING to indicate that the filter no longer operates correctly CR 34298 Technician Int
6. MOSPF A bus error occurred on a router configured with 1000 source group pairs and generating multicast traffic at a rate of 14 000 packets per second CR 35770 DVMRP A router receiving traffic at a rate of 10 000 packets per second for 2000 source groups experiences a watchdog error and subsequently faults CR 35940 DVMRP The router experiences a panic at dvmrp_cache c at line 443 CR 72024 FTP A problem occurs when attempting to transfer small files from a UNIX system to the router via FTP CR 72146 OSI When you alter the cost of an OSI External Adjacency the new cost is not reflected in the routing table until you restart the adjacency interface or OSI 301894 B Rev 00 Release Notes CR 72151 OSI When the router updates an OSI interface Hello password the new security string is not reflected in the router s Hello messages until you restart either the interface or OSI CR 72237 IP When you reinitialize BootP after restarting an ATM interface a machine check occurs in BootP CR 72565 Switched Services You cannot manually activate a standby circuit CR 72996 Switched Services SPID is not registering after TE1 loss because two SPIDS are sent out of order CR 73254 DVMRP wfDvmrpBasePolicyEnable should be obsoleted from the wfDvmrpBase record CR 75414 APPN In a large APPN network some routers fault at unpredictable times CR 75456 APPN An intermittent bus error occurs when an
7. OSPF An AS External Route may fail to be installed into a routing table if a more specific route with the same address exists For example 10 4 0 0 255 252 0 0 would fail to install if 10 4 0 0 255 255 255 0 existed CR 35935 DLSw When you disconnect a token ring interface a memory leak occurs and the router slot faults CR 35992 ARE When an LE_ARP request is sent to an ARE and the request is for the Group LAN ID of the source route bridges in the network the ARE fails to respond Note that the router will now respond to the LE_ARP however the network should be designed so that only one Bay Networks router will receive and respond to the LE ARP that is sent CR 36052 OSPF A problem exists in OSPF where under certain configurations it will summarize a summary advertisement that is based on a stub network that is down When the stub network goes down OSPF fails to flush the summary generated based on the stub CR 71080 IP IP traffic filter sends a message to the router log even if there is a match on another traffic filter higher in the list 34 301894 B Rev 00 Release Notes CR 71085 OSPF In an Autonomous System Border Router ASBR when you create a new IP interface it is immediately advertised as a type 5 external by OSPF Later when OSPF is configured on that interface it now becomes a type I or 2 and is advertised as such However OSPF does not flush out the old type 5 that was generated
8. SYNC characters and should be hardcoded for 7 SYNC characters The router software code requires configurable leading SYNC characters in order to interoperate CR 35899 BGP When you create a BGP peer for a circuitless IP address invalid and or multiple instances of wfCircuitNameEntry are created CR 35918 Switched Services When you delete a dial on demand schedule entry the following error message appears Function was not found xref_standby_tod_delete This message occurs only when you use Site Manager to configure an 11 02 or an 11 01 MIB attribute No CR Dial on Demand If you configure scheduled dial on demand and you accept the default of 2400 for the End of Time parameter an error occurs 301894 B Rev 00 43
9. and you have BGP collision detect disabled changes to the announce policy do not take effect 301894 B Rev 00 17 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 78421 ATM A router running Source Route Bridge over Token Ring may cause an MCP error CR 78669 DLSw Slow performance occurs when you transfer NetBIOS files using DLSw RFC 1795 CR 33696 Frame Relay Switch When you change secondary Host FRAD point to point or multidrop local device DLSw mode to primary while operating in dynamic configuration mode all sessions on the slot drop CR 74486 BGP The BGP peer delay parameter should not be configurable through the BCC The BCC is able to configure more BGP peer configurable parameters than Site Manager Site Manager cannot configure the delay or detect as loop parameters CR 71942 FTP The router crashes when you try to change the local directories while the router is connecting CR 78499 SDLC SDLC trace logging is not fully implemented CR 79286 Router Redundancy The router redundancy script show rredund role displays the role incorrectly it displays both the members as primary under certain conditions CR 73045 ARE An ARE may intermittently hang or have out of buffer crashes due to buffers getting stuck in a holding tank 301894 B Rev 00 Release Notes CR 73435 ISP Multicast traffic is not forwarded when ISP mode is enabled CR 74931 ATM An ATM
10. applies to all Software acquired for use within the European Community If Licensee uses the Software within a country in the European Community the Software Directive enacted by the Council of European Communities Directive dated 14 May 1991 will apply to the examination of the Software to facilitate interoperability Licensee agrees to notify Bay Networks of any such intended examination of the Software and may procure support and assistance from Bay Networks 7 Term and termination This license is effective until terminated however all of the restrictions with respect to Bay Networks copyright in the Software and user manuals will cease being effective at the date of expiration of the Bay Networks copyright those restrictions relating to use and disclosure of Bay Networks confidential information shall continue in effect Licensee may terminate this license at any time The license will automatically terminate if Licensee fails to comply with any of the terms and conditions of the license Upon termination for any reason Licensee will immediately destroy or return to Bay Networks the Software user manuals and all copies Bay Networks is not liable to Licensee for damages in any form solely by reason of the termination of this license 8 Export and Re export Licensee agrees not to export directly or indirectly the Software or related technical data or information without first obtaining any required export licenses or other governmenta
11. free disk space Microsoft Windows 95 TCP IP protocol and compatible network adapter and driver CD ROM drive VGA monitor SuperVGA monitor recommended 1 Manager Version 6 02 requires the Windows 95 TCP IP protocol stack and a compatible network adapter and driver If you purchased a machine with Windows 95 and a network adapter installed most likely you have the correct TCP IP protocol network adapter and driver Proceed to step 2 to test TCP IP However if your PC was upgraded from Windows 3 1 it may have an existing 16 bit TCP IP stack like Distinct TCP IP Run Time In this case you must uninstall the 16 bit TCP IP stack before adding the Windows 95 TCP IP protocol stack To uninstall a 16 bit TCP IP stacks refer to the TCP IP provider s documentation and support for help in removing the stack s path statements services file and WINSOCK DLL files dated prior to 7 11 95 That is the date of the WINSOCK DLL file installed by Windows 95 To add or update a protocol network adapter or driver refer to the appropriate documentation and support from Microsoft and the adapter manufacturer Protocols and driver 301894 B Rev 00 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes updates are added from the Network option of the Control Panel New network adapters and their drivers are added from the Add New Hardware option of the Control Panel Windows 95 attempts to match a driver
12. interface stops transmitting or intermittently transmits if a router is connected to an ATM switch that supports OAM This problem occurs if the remote end of a PVC is brought down CR 33600 28218 IP A fault occurs after a route with an invalid subnet mask is added to the route table and then a subsequent route in the same range is submitted CR 34487 PPP If you have multiple PPP circuits on the same slot configured for LQR a race condition may occur when the circuit states change causing a bus error CR 35021 OSPF The ignore action of an OSPF accept policy does not work CR 71691 IP This is an enhancement request to add support for Multicast Packet Replicator MPR CR 73764 73480 IP The router drops IP packets after ARPing for a destination address CR 32997 IP When a Token Ring interface receives a segmented IP packet that was incorrectly routed to it the interface fails to send a second packet to the next correct hop CR 36033 IP Issuing the traceroute command with the LSRR g option causes a packet that arrived with a ttl of 1 to have a ttl of 255 301894 B Rev 00 19 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 30447 BGP4 This is an enhancement to optimize regular expression processing for BGP4 route policies CR 29419 IP This is an enhancement request for a router in host only mode configured as Bridge to listen to RIP packets so that it can make for
13. is activated regardless of the configured time day This occurs only when the Availability Mode parameter is set to Not Available CR 71429 IP A router running in ISP mode may experience a bus error when a forward to next hop filter is matched and the next hop does not exist and there is no route to the final destination of the frame CR 71769 Source Route Bridge In IP Encaps source route frames received on a source routing interface do not get sent out over the IP Encaps cloud after IP is restarted CR 72190 IGMP This is an enhancement request to add a MIB attribute to control whether non local reports should be accepted CR 72328 IP When adding IP to a 10 MB Ethernet interface the router faults 301894 B Rev 00 Release Notes CR 72641 NAT If both the local host address and the translated address contain two digits at the end FTP fails when you issue a port command For example if the local host IP address is xx xx xx 16 and the translated address is xx xx xx 17 an FTP session can be initiated However as soon as you issue a port command the FTP session terminates CR 73832 SDLC The router fails to set the poll bit in I frames on an SDLC line which can result in excessive retransmissions and line performance degradation with certain controllers CR 74090 QLLC The router is unable to establish a session between the IBM 3174 X 25 client and an IBM Token Ring host in a Downstream QLLC Netw
14. log file falsely indicates a problem with the creation of the static route when in fact the static route is created CR 81714 X 25 You may see an Orphaned Buffer error during heavy IPEX traffic containing varying packet sizes This error was recorded once in BayRS 12 02 and the data sessions all recovered CR 81761 DVMRP When you configure DVMRP in dynamic mode Site Manager attemps to set the wfDvmrpBase 18 0 MIB attribute which results in an SNMP set error message This prevents you from properly configuring DVMRP 301894 B Rev 00 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes BayRS Version 12 02 Fixed Anomalies Bay Networks has fixed the following anomalies in BayRS Version 12 02 Router Version is managed by Site Manager version V12 02 gt 6 02 v12 01 revision 1 gt 6 01 and 6 01 rev 1 v12 01 revision 2 gt 6 01 and 6 01 rev 1 v12 01 revision 3 gt 6 01 and 6 01 rev 3 CR 80180 DLSw A problem may occur when you try to establish DLSw TCP peers If you notice only the write 2067 to read 2065 TCP connection being opened for RFC 1434 and 1795 types of peers and you see that connection establishment between the client and host takes a long time set this mib value from the Technician Interface s wfDIsPeerEntry wfDisPeerInteroperability 2 commit This is only applicable o
15. low value 4 or 5 CR 80212 IPEX X 25 Gateway IPEX Gateway sessions may hang under heavy load of large packets CR 80772 IPEX X 25 Gateway If the IPEX State machine in the established EST state receives a reset request it stays in the established state and never goes to the connection CONN state CR 80532 BGP Routes are not properly withdrawn if a BGP route matches a network criteria exactly 301894 B Rev 00 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 30189 Scripts If you run the embedded show script for an IP circuit whose circuit name contains a lowercase alpha character the circuit is not found CR 33681 LNM When you run the file Inm bat it loops infinitely CR 70923 DECnet In a simple DECnet environment an adjacency is being removed from the wfivLevellRouteEntry attribute prematurely because the router incorrectly counts 3 Hello packets as received CR 72633 VINES When a VINES client sends a broadcast request all servers respond The client connects to the first server and then sends a disconnect message to the other servers When the VINES client sends the disconnect message the VINES interface on the router performs intensive processing for the forward cache and the slot where the client resides experiences a Watchdog fault CR 73793 DLSw If the upstream host side issues a disconnect followed by an XID poll 5 ms later the XID poll will reset the inter
16. of 6144 sessions per router 301894 B Rev 00 37 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 71031 BGP In order for BGP routes to be exported to the OSPF link state database the BGP Intra AS parameter must be set to Disabled By default this parameter is set to Enabled If you disable this parameter dynamically Site Manager generates multiple bus errors and a watchdog CR 32979 APPN When you configure the APPN protocol and you enter a local node name a core dump occurs CR 78156 Source Route Bridge When you configure a sync interface for source route bridging the Source Routing Interfaces window from the Protocols pull down menu option on the Frame Relay Service List window shows all Os for the sync interface CR 78538 Router Redundancy When you configure the Automatic Role Switching parameter from the Router Redundancy Group Global window the Values button shows only two options Manual and Auto According to the Help window and to the documentation four options are available Manual Auto Switch on Failure and One Shot Auto CR 78722 IPX If you enter a valid DLCI in the IPX adjacent host definition Site Manager displays an error message indicating that you have entered an incorrect number range or format CR 75561 IP When you reorder a small traffic filter in ascending or descending order past a large traffic filter with many IP addresses within the same filt
17. the granted units counter reaches zero which is a protocol violation CR 72792 LLC When an LLC interface is disabled a panic may occur after 30 minutes instead of after one minute if the router is having resource problems CR 28639 APPN To use a default DLUS name for link stations that are not defined in the APPN Adjacnet Link Stations table you must define both the Default DLUS name and the Backup Default DLUS name CR 31110 SNMP When you type show snmp base using the Technician Interface the displayed information has some misspelled words CR 32728 APPN If you enable APPN on a HSSI interface configured for SMDS the router experiences a bus error 301894 B Rev 00 13 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 32804 Learning Bridge This is an enhancement request to add a MIB attribute under wfBrTp called wfBrTpBaseFDB PortChange which counts the number of times that an entry in the forwarding table has changed ports that is a MAC address is learned via port A then re learned via port B CR 33900 TCP The current TCP code does not have the capability to deregister on the slots on which it has registered the connection Rather it tries to deregister on all the slots passed in by the client when the connection was opened CR 35181 MCEI The ASN router experiences a tag violation upon bootup when MCE is not physically present although configured CR 35497
18. to fail CR 32879 IP When you try to configure additional interfaces on a BLN configured for Host Only Mode faults occur in map_rem c CR 32902 Frame Relay The show fr stat circ command displays Drops as Discards and Discards as Drops The command does display the correct numbers CR 33039 DVMRP If a neighbor does not send a probe to DUT after the timer is modified the neighbor does not get timed out as per the new modified timer value wfDvmrpBaseNeighborTimeout The neighbor gets timed out with the old timer value If DUT receives a probe after the timer is modified the neighbor gets timed out as per the new timer value CR 33136 FDDI FDDI interface does not recover after receiving PC trace message with external bypass switch CR 33353 Frame Relay Source route bridging will stop forwarding packets when you dynamically change hybrid mode on a frame relay permanent virtual circuit PVC To correct the condition you must reset the sync interface 24 301894 B Rev 00 Release Notes CR 33408 IP This is an enhancement request to add a global parameter that causes the router to disregard packets sent to an address that the local router knows is a broadcast address Added a new attribute to IP Base MIB called wfIpBaseDirectedBcastEnable which should be set to Disabled to turn off directed broadcasts CR 33453 LAPB LAPB retransmits already acknowledged X 25 packets causing the X 25 switch on t
19. to the network adapter installed on your computer If Windows 95 cannot match a compatible driver you need to update the drivers Contact the adapter manufacturer for the latest drivers Microsoft and other Windows 95 Web sites may also have updated drivers Refer to Microsoft Windows 95 Resource Kit for additional technical information about these issues A hard copy is available from Microsoft Press 2 Test the TCP IP installation by pinging an IP address If you are unable to PING the adddress there could be a problem with the TCP IP installation To install the PC Site Manager software from CD 1 Access the Run window by selecting Run from the Start menu 2 Type the CD ROM drive path and executable file lt CD ROM drive gt ms_win setup exe The D drive is usually the CD ROM drive 3 Click on OK 4 301894 B Rev 00 Release Notes GENERAL Problem No text is displayed on some or all of the screens Solution Make sure that the jam ini file is in the WINDOWS directory For Example c windows jam ini Known Anomalies in Version 12 02 6 02 This section describes the following known anomalies CR 74897 IP When creating a static route e g 128 10 8 0 255 255 255 0 1 the router erroneously generates the following error message in the router log file 2 04 16 98 09 44 24 096 WARNING SLOT 5 IP Code 56 Error when configuring status route 128 10 8 0 255 255 255 0 1 In this case the
20. 9 66 33 4 92 96 69 96 Asia Pacific 61 2 9927 8888 61 2 9927 8899 Latin America 561 988 7661 561 988 7550 301894 B Rev 00 vii BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes Information about customer service is also available on the World Wide Web at support baynetworks com How to Get Help If you purchased a service contract for your Bay Networks product from a distributor or authorized reseller contact the technical support staff for that distributor or reseller for assistance If you purchased a Bay Networks service program call one of the following Bay Networks Technical Solutions Centers Technical Solutions Center Telephone number Fax number Billerica MA 800 2LANWAN 978 916 3514 Santa Clara CA 800 2LANWAN 408 495 1188 Valbonne France 33 4 92 96 69 68 33 4 92 96 69 98 Sydney Australia 61 2 9927 8800 61 2 9927 8811 Tokyo Japan 81 3 5402 0180 81 3 5402 0173 Bay Networks Educational Services Through Bay Networks Educational Services you can attend classes and purchase CDs videos and computer based training programs about Bay Networks products Training programs can take place at your site or at a Bay Networks location For more information about training programs call one of the following numbers Region Telephone number United States and Canada 800 2LANWAN then enter Express Routing Code ERC 282 when prompted 978 916 3460 direct
21. APPN link to an RS 6000 configured as an NN goes down CR 75726 Switched Services The weekend schedule for a backup circuit does not function correctly when another schedule is configured For example if you modify the date on the router so that the backup circuit is active for the scheduled weekday the backup circuit is not active CR 29307 APPN When you have Dependent PU2 0 devices in session and enter the command appn show dlur route invalid data is displayed in the route field 301894 B Rev 00 15 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 71585 Technician Interface The Technician Interface command show csmacd stats displays large numbers approaching 2 000 000 000 as negative numbers CR 33867 34692 IP IP Packet fragmentation in ISP mode is not working properly CR 33685 OSI Duplicated OSI routing table entries may occur when load balancing is disabled CR 72134 ASN An ASN router with 100 MB Ethernet modules and Circuitless IP experiences bus errors at bootup CR 71001 ARN The LEDs remain on for both B channels even though both channels are not being used CR 78426 Learning Bridge An orphan buffer may occur when you bridge packets over a PPP interface CR 78501 DLSw DLSw does not handle the HALT_NOACK command defined in RFC 1795 CR 78498 GAME No log message is written when a fault occurs on the router and no crash dump is written to the flash
22. BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes BayRS Version 12 02 Site Manager Software Version 6 02 4401 Great America Parkway 8 Federal Street Santa Clara CA 95054 Billerica MA 01821 Copyright 1998 Bay Networks Inc All rights reserved Printed in the USA August 1998 The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary to Bay Networks Inc The software described in this document is furnished under a license agreement and may only be used in accordance with the terms of that license A summary of the Software License is included in this document Trademarks AN BLN GAME and Bay Networks are registered trademarks and ARN BayRS and the Bay Networks logo are trademarks of Bay Networks Inc All other trademarks and registered trademarks are the property of their respective owners Restricted Rights Legend Use duplication or disclosure by the United States Government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 Notwithstanding any other licen
23. ED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE In addition the program and information contained herein are licensed only pursuant to a license agreement that contains restrictions on use and disclosure that may incorporate by reference certain limitations and notices imposed by third parties ii 301894 B Rev 00 Bay Networks Inc Software License Agreement NOTICE Please carefully read this license agreement before copying or using the accompanying software or installing the hardware unit with pre enabled software each of which is referred to as Software in this Agreement BY COPYING OR USING THE SOFTWARE YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT THE TERMS EXPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS UNDER WHICH BAY NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE If you do not accept these terms and conditions return the product unused and in the original shipping container within 30 days of purchase to obtain a credit for the full purchase price 1 License Grant Bay Networks Inc Bay Networks grants the end user of the Software Licensee a personal nonexclusive nontransferable license a to use the Software either on a single computer or if applicable on a single authorized device identified by host ID for which it was originally acquired b to copy the Software solely for backup purposes in support of authorized use of the Software and c to use and c
24. EDES ALL PRIOR ORAL AND WRITTEN AGREEMENTS AND COMMUNICATIONS BETWEEN THE PARTIES PERTAINING TO THE SUBJECT MATTER OF THIS AGREEMENT NO DIFFERENT OR ADDITIONAL TERMS WILL BE ENFORCEABLE AGAINST BAY NETWORKS UNLESS BAY NETWORKS GIVES ITS EXPRESS WRITTEN CONSENT INCLUDING AN EXPRESS WAIVER OF THE TERMS OF THIS AGREEMENT iv 301894 B Rev 00 Contents Technical Support Bay Networks Technical Publications ccccceeseceeeeeeeeeceeeeeeeeeeeeeeaaeeeeeneeseaeeesaaeeeeneeee vii Bay Networks Customer Service ccceceececeeeeeeeeeeeeeeeeceaeeeseaaeeseeeeesaaeeseeeeeesiaeeeseneeesaas vii How to Get H IP vitae kadre ted tats etebeussl eietee A dative dtaaetans viii Bay Networks Educational Services c cccccccceseeeeeeeeeeeeeeeeseneeseneeeeeaaeseaaeesecaeetaeeeeeneeess viii BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes Maintenance Release Methodology mmrrrrnnnnvnnnrnvvnnnnrnnnnnnnnnnnrrnnnnnenernrrenannnenenresnnnrnennnneenn 1 Year 2000 GoOmpliance sauna annara aea aaa ea araa eraa ea aaa aaiae 2 Image Builder Operational Note rrrnrnnrrnnnnnvnnnnrrnnnnnvnnnrnrennnnrnnnrnnnnnnnrnesnnnnnrrnrnesnnnnnennnenenn 2 PC Site Manager READ ME FIRST File c ccccseeeeeeeeeeeeeeeeeeeeeeeeesaeeeeeeeeeseaeeeeeeeeseaees 2 Known Anomalies in Version 12 02 6 02 0 ccccccceececeeeeeeceeeeeeeeeeeeeaaeeseeeesseaeeeeeeeeeeaeeseneees 5 BayRS Version 12 02 Fixed Anomalies ccccccece
25. OT 3 TOKEN_RING Code 26 Connector MAU2 open error phase 3 error 8 This message indicates that a serious event has occurred one that may prevent access to a token ring to a router The phase and error codes tell you what is halting the access CR 34746 QLLC A bus error occurs after X 25 calls are cleared several times CR 34753 ANH After you boot an ANH router using fi cfg all partition and link LEDs remain on even though the router does not have an Ethernet interface configured The lights do not go out until you run the install script and select Ethernet as the driver type CR 34776 ATM An orphan buffer FAULT may occur in an environment where the ATM switch is frequently closing active ATM data virtual circuits CR 34868 Translation Bridge When a source routing traffic filter is applied to a packet the router drops the packet destined for the source routing interfaces but does not drop the packet destined for learning bridge interfaces CR 34908 DECnet After you enable a DECnet router on an Ethernet VLAN a VBM error occurs on a router that is attached to the Ethernet VLAN via ATM 301894 B Rev 00 29 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 34922 PPP After you enable wfPppLineEntry wfPppLineRfc1661Compliance the value for wflIpIntfStatsEntry wflIpIntfStatsMaxInfo does not change This results in wfIpIntfStatsEntry wfIpIntfStatsMaxInfo having a larger value t
26. Y NETWORKS OR ITS LICENSORS BE LIABLE FOR ANY COST OF SUBSTITUTE PROCUREMENT SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES RESULTING FROM INACCURATE OR LOST DATA OR LOSS OF USE OR PROFITS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE SOFTWARE EVEN IF BAY NETWORKS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT SHALL THE LIABILITY OF BAY NETWORKS RELATING TO THE SOFTWARE OR THIS AGREEMENT EXCEED THE PRICE PAID TO BAY NETWORKS FOR THE SOFTWARE LICENSE 5 Government Licensees This provision applies to all Software and documentation acquired directly or indirectly by or on behalf of the United States Government The Software and documentation are commercial products licensed on the open market at market prices and were developed entirely at private expense and without the use of any U S Government funds The license to the U S Government is granted only with restricted rights and use duplication or disclosure by the U S Government is subject to the restrictions set forth in subparagraph c 1 of the Commercial Computer Software Restricted Rights clause of FAR 52 227 19 and the limitations set out in this license for civilian agencies and subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause of DFARS 252 227 7013 for agencies of the Department of Defense or their successors whichever is applicable 6 Use of Software in the European Community This provision
27. base was enabled or since wfLleInterfaceHi WaterReset was set to 2 CR 30870 ISDN When you change a valid ISDN local telephone number in dynamic mode the router terminates operation CR 30998 DLSw If you substitute a wildcard as part of a MIB instance ID when performing a MIB get operation on the MIB entry wfDlsConnectionEntry the router responds with an incorrect answer CR 31797 ARP This is an enhancement request to add a Technician Interface command that would clear out every ARP entry learned from a specific IP interface A new command clear ip arp prefix prefix_length was added to clear the entries learned on the given subnet CR 31861 Compression When you run sync passthru over MLPPP with compression and WCP is configured on the PPP interface several bus errors and tag violations occur CR 32070 Dial on Demand In a configuration where AURP runs over a dial on demand line with WCP configured IP eventually loses connectivity 22 301894 B Rev 00 Release Notes CR 32142 IP A counter problem causes wfIpInterfaceCacheNetworks to show a larger value than wfIpInterfaceFwdCacheSize wfIpInterfaceCacheNetworks should never be larger than wfIpInterfaceFwdCacheSize CR 32169 Spanning Tree The spanning tree algorithm selects the wrong bridge as the root bridge if the difference between two bridge IDs is greater than 0x8001 CR 32236 Technician Interface If you try to save a large configura
28. ect the Values button for the Sync B Channel Override parameter the message Sorry No additional information available appears The valid values are BCHANNEL 1 BCHANNEL2 Default and FLOATINGB 301894 B Rev 00 39 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 72050 Traffic Filters When you delete a traffic filter in dynamic or remote mode Site Manager does not remove the filter from the list In local mode Site Manager removes the filter when you save the configuration file CR 75894 Protocol Priority When you apply a new Protocol Priority outbound filter Configuration Manager faults and then terminates The fault occurs on the PC only CR 28400 Router Files Manager If you enter an invalid community name in the Router Files Manager window Site Manager displays the error message Unable to reach Router When you click on OK the same message appears again CR 72781 Fire Wall The FireWall product was introduced in 11 02 Rev 2 When you use Site Manager to connect to a router that is running a release earlier than 11 02 the FireWall menu should be unavailable CR 71674 APPN If you use Site Manager to configure an APPN interface over frame relay using source routing and you add an Adjacent Link Station Site Manager incorrectly sets the MIB attribute wfAppnNodeDlcType to 3 transparent bridging The correct setting for this attribute is 2 source routing CR 72630 Token Ring
29. eeeeeneeceeeeeesaeeeeneeeceaeeeseaeeeseeeeeenaeeesaees 6 Site Manager Software Version 6 02 Fixed Anomalies ccccceeeeceeeeeeteeeeeeseaeeeeeeeees 37 301894 A Rev 00 V Technical Support Bay Networks Technical Publications You can now print technical manuals and release notes free directly from the Internet Go to support baynetworks com library tpubs Find the Bay Networks products for which you need documentation Then locate the specific category and model or version for your hardware or software product Using Adobe Acrobat Reader you can open the manuals and release notes search for the sections you need and print them on most standard printers You can download Acrobat Reader free from the Adobe Systems Web site www adobe com Documentation sets and CDs are available through your local Bay Networks sales office or account representative Bay Networks Customer Service You can purchase a support contract from your Bay Networks distributor or authorized reseller or directly from Bay Networks Services For information about or to purchase a Bay Networks service contract either call your local Bay Networks field sales office or one of the following numbers Region Telephone number Fax number United States and 800 2LANWAN then enter Express Routing 978 916 3514 Canada Code ERC 290 when prompted to purchase or renew a service contract 978 916 8880 direct Europe 33 4 92 96 6
30. er a memory fault condition occurs on the router In some cases Site Manager unloads IP from the slot CR 75236 MCT Accessing circuit information for an MCT1 causes Site Manager to abort with the following error The Configuration module completed abnormally E1701 38 301894 B Rev 00 Release Notes CR 35695 SNMP When you attempt to delete an SNMP community the message SNMP Set Error appears When you press OK or Cancel to remove the message the message reappears CR 75254 SNMP When you click on OK from the Edit Adapter Module 2 56 64K DUS CSU Parameters window Site Manager sets the attribute wfSyncExternalClkSpeed to the value determined by the Option Mode parameter even if the attribute s value has not changed CR 76000 ISDN When you configure an MCT 1 port for PRI and you enable RFC 1661 compliance if you change the MRU size the information message Please make sure that the SYNC MTU is gt PPP MRU 56 bytes appears for each channel on the MCT 1 port The message should only appear once CR 73309 BGP Site Manager does not allow you to change the value for the Route Preference parameter in a BGP4 accept policy CR 75049 IP When you delete BGP 3 from a configuration Site Manager deletes all the IBGP peers CR 75303 X 25 When you add an X 25 PTOP line the Connection ID parameter defaults to 0 The range of valid values is from 1 to 255 CR 75341 Sync When you sel
31. erface If you telnet to a circuitless IP address on an ARE and run various Technician Interface processes VBM errors may occur CR 34322 TCP TCP retransmit time out value RTO is set to wfTcpRtoMax regardless of actual RTT even if the actual RTT is short If wf TcpRtoMax is the default 4 minutes traffic over TCP for example DLS suddenly stops for 4 minutes CR 34416 PPP Multilink This is an enhancement request to change the fragmentation algorithm to require that frames larger than the configured fragment size be fragmented CR 34423 X 25 When a router recovers from congestion it sends an X 25 RNR packet but may fail to generate an X 25 RR packet because it is waiting for another part of a fragmented packet CR 34471 DLSw Performing MIB gets on wfLIcLinkEntry does not show all instances For example if you configure DLSw on 2 slots bring up DLSw connections on both slots and then enter g wfLIcLinkEntry 3 only one circuit is displayed CR 34602 DLSw A bus error may occur after you delete an X 25 circuit on a client router while two QLLC sessions are active The bus error also terminates operation of the second circuit on the slot CR 34653 DLSw A bus error occurs when you boot a BLN router with a variety of DLS configurations 301894 B Rev 00 27 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 34660 DLSw If you have DLS peers pointing to each other and o
32. han wfPppLineEntry wfPppLineMru To change the value for wfIpIntfStatsEntry wfIpIntfStatsMaxInfo you must either reboot the router or reset the slot This fix applies to only non dial services lines CR 34948 DLSw The log message SSP rcv command in TCP local 14 should be changed to NetBIOS DATAFRAME Rcv to be more intuitive to the users reading the log CR 34959 DLSw Remote DLSw clients do not reestablish a connection to the host after a network disruption CR 34988 OSPF Bouncing OSPF on an Area Border Router with several point to point OSPF nbrs may result in a bus error in OSPF CR 35041 IP In BayRS Version 12 00 or greater ASB all subnet broadcast does not work in ISP mode CR 35116 IPEX IPEX in gateway mode will not accept new TCP connection requests for sessions where the TCP peer detected a TCP Open timeout that is the router was too slow to accept the request to open IPEX must be able to recover from unaccepted TCP Accepts CR 35129 X 25 Gateway If you bring down a large number of sessions by killing the server process a bus error occurs in the X 25 gateway 30 301894 B Rev 00 Release Notes CR 35132 DLSw After a router receives an LLC XID frame the router may not transmit a CANUREACH cs message which causes the router connections not to come up CR 35136 MIB When you issue the I i wfMod command a bus error occurs Occasionally this bus error triggers a GAME resta
33. he other side to reset the LAPB session between the X 25 switch and the router This causes X 25 virtual circuits to be reset and IP circuits over those virtual circuits to come down CR 33566 ISDN PRI When log messages are written to the log an exception vector 3 address error may occur because of a corrupted stack CR 33577 IP A condition exists in all revisions of code where IP_BARP will consume all buffers on a slot if an external device is trying to reach nonexistent but valid host addresses on a subnet A new MIB attribute wfIpBaseArpBufLimitPrent was added to wfIpBase to specify the percentage of total buffers that can be used by IP_BARP for buffer saving To monitor this buffer activity a new IP command ip arp_buf was added CR 33604 IP The router stops forwarding ASB packets out an interface after you make a dynamic change to an interface that has the same natural IP network configured as that interface CR 33634 IP The hog buf in the IP Routing Table Manager can cause the slot to run out of buffers thereby causing other gates to error on the same slot 301894 B Rev 00 25 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 33696 FRAD When you configure DLSw in dynamic configuration mode changing the secondary HostFRAD point to point or multidrop local device to primary causes all sessions on the port to fail CR 34023 DLSw When a frame relay link breaks or the
34. hough the Multihop EBGP Connection parameter is set to Enabled you cannot configure BGP peers that are not on the same subnet CR 34872 PPP SYNC MTU must be at least 56 bytes greater than PPPMRU CR 35580 LLC2 traffic filters Site Manager lets you create LLC2 traffic filters under the wrong circuit number If you create an LLC2 traffic filter by selecting LLC Circuit gt LLC2 Circuit and then Protocols gt LLC2 Traffic filters the filter will not work because Site Manager uses a circuit number that is different from the number assigned to this interface CR 30906 IP A problem exists when you apply a template to a circuit that has one IP source address range 22 IP destination address ranges and at least one TCP destination port When this template is applied to a circuit it shows up in two fragments Neither fragment has a circuit number or IP address both fragments are inactive 42 301894 B Rev 00 Release Notes CR 35936 IP When you use a circuitless IP address with an instance number of 1 under wfCircuitNameEntry Site Manager can cause the router to unload and reload certain protocols CR 33589 IPX When you delete IPX from a WAN interface e g frame relay or PPP Site Manager does not remove the IPX circuit instance completely CR 34024 BOT This is an enhancement request to enable the Bisync protocol to support more leading SYNC characters Currently the BISYNC code is hardcoded for 2 leading
35. isuse or abuse The Licensee assumes all responsibility for selection of the Software to achieve Licensee s intended results and for the installation use and results obtained from the Software Bay Networks does not warrant a that the functions contained in the software will meet the Licensee s requirements b that the Software will operate in the hardware or software combinations that the Licensee may select c that the operation of the Software will be uninterrupted or error free or d that all defects in the operation of the Software will be corrected Bay Networks is not obligated to remedy any Software defect that cannot be reproduced with the latest Software release These warranties do not apply to the Software if it has been i altered except by Bay Networks or in accordance with its instructions ii used in conjunction with another vendor s product resulting in the defect or iii damaged by improper environment abuse misuse accident or negligence THE FOREGOING WARRANTIES AND LIMITATIONS ARE EXCLUSIVE REMEDIES AND ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Licensee is responsible for the security of its own data and information and for maintaining adequate procedures apart from the Software to reconstruct lost or altered files data or programs 301894 B Rev 00 iii 4 Limitation of liability INNO EVENT WILL BA
36. l approvals Without limiting the foregoing Licensee on behalf of itself and its subsidiaries and affiliates agrees that it will not without first obtaining all export licenses and approvals required by the U S Government i export re export transfer or divert any such Software or technical data or any direct product thereof to any country to which such exports or re exports are restricted or embargoed under United States export control laws and regulations or to any national or resident of such restricted or embargoed countries or ii provide the Software or related technical data or information to any military end user or for any military end use including the design development or production of any chemical nuclear or biological weapons 9 General If any provision of this Agreement is held to be invalid or unenforceable by a court of competent jurisdiction the remainder of the provisions of this Agreement shall remain in full force and effect This Agreement will be governed by the laws of the state of California Should you have any questions concerning this Agreement contact Bay Networks Inc 4401 Great America Parkway PO Box 58185 Santa Clara California 95054 8185 LICENSEE ACKNOWLEDGES THAT LICENSEE HAS READ THIS AGREEMENT UNDERSTANDS IT AND AGREES TO BE BOUND BY ITS TERMS AND CONDITIONS LICENSEE FURTHER AGREES THAT THIS AGREEMENT IS THE ENTIRE AND EXCLUSIVE AGREEMENT BETWEEN BAY NETWORKS AND LICENSEE WHICH SUPERS
37. le filters on a circuit each with a different priority In this case only the first filter first one created and highest priority is matched CR 72074 X 25 If X 25 receives a disconnect request from the local interface and then receives a disconnect from the remote interface through IPEX the VC may remain in an operational state and never be cleared CR 72526 IPEX IPEX in gateway mode incorrectly accepts new TCP connection requests before the previous session was completely terminated causing the IPEX session to hang 36 301894 B Rev 00 Release Notes Site Manager Software Version 6 02 Fixed Anomalies Bay Networks has fixed the following anomalies in Site Manager Software Version 6 02 Site Manager Software Version 6 02 is a post 6 00 revision This version is backward compatible and supports the following router software versions 12 02 12 01 12 00 11 02 11 01 11 00 CR 78926 SDLC After you change the DLSw mode on the SDLC link from Secondary to Primary the configuration becomes corrupted and causes SDLC to continuously issue bus errors until the slot resets CR 79837 IPEX X 25 This is an enhancement request to expand the range of TCP port numbers available for use by IPEX X25 gateway when configuring the local TCP port in mapping entries The current range allowed is 12304 to 16399 The range should be 10256 to 16399 to allow for 768 mappings to exist on up to 8 slots of a router for a total
38. n routers running 11 03 rev 3 or above or 12 01 rev 1 or above with DLSw peers configured CR 73533 IPEX X 25 Gateway When IPEX X 25 Gateway is run with header type NONE No Boundary protocol messages may be dropped by IPEX as they are sent to the TCP subsystem for transmit 6 301894 B Rev 00 Release Notes CR 80105 ATM In SSCOP when the top of the transmit window is reached subsequent messages are queued up for later When the transmit window is incremented the postponed messages are not sent out The messages remain in the private buffer pool for the SSCOP gate until some event e g bouncing signaling restores them Depending on the circumstances the slot may run out of buffers CR 80231 FireWall The router reports invalid interface numbers to Firewall s Logviewer Instead of reporting the circuit number the router reports the line number CR 80007 TCP TCP peers are very slow to form in a DLSw environment where many peers are configured CR 33841 ATM The SSCOP window does not conform to the Q SAAL Q 2110 specification Bay Networks router code does not respect the Q SAAL window credit specified by the switch As a side effect of this change LECs may struggle to come up if signaling goes down for any reason because the router and the switch cannot communicate fast enough to keep the connections from timing out If this occurs we suggest that the value of wfAtmSscopEntry wfAtmSscopMaxPd be set to a
39. nal LLC connection from stat HALT_PENDING to CIRCUIT_PENDING The SDLC side disconnects while the LLC side proceeds to the connected state This condition results in an interoperation problem with the 5745 Enterprise Server CR 74752 NAT A problem exists when running NAT with the Mapping Entry timeout enabled If you have set a large amount of dynamic mapping entries and set the Max Timeout value the router faults with a tag violation CR 75084 IP A problem exists in an ISP environment in which full internet routes are installed 50000 Attempting to run an SNMP get of the arp table wfIpNetToMediaEntry causes MIB_MGR to consume CPU from 259 ms to 305 ms multiple times This causes forwarding performance problems on interfaces related to the slot where the get is being executed 8 301894 B Rev 00 Release Notes CR 75429 IP When a router running in ISP mode receives an all subnet broadcast ASB traffic whose destination includes other interfaces on the same router a bus error occurs CR 26774 ATM A router running LANE crashes with an MCP error after losing and then regaining signaling CR 32385 APPN Dynamically adding LS to a frame relay interface causes a bus error to occur on the router CR 34175 ATM An MCP error occurs during a dynamic configuration in an Ethernet LANE environment while adding IP RIP to the second service record CR 34236 SYNC A bus error occurs when trying to use asynchr
40. ncorrect CR 31321 DLSw If you configure a local device with maxdata on the DLSw local device window when you exit the window an error message appears warning you that the maxdata is larger then the sync MTU This happens only in dynamic mode CR 34913 Source Route Bridge After you configure source route bridge on a dial on demand circuit or an ATM service record the source route interface window displays zeroes in all fields for that circuit 301894 B Rev 00 41 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 35239 X 25 When you configure X 25 QLLC Maps Site Manager leaves the Generate XID field empty To save the window you must enter Enable in the Generate XID field However Site Manager incorrectly sets the MIB entry for this field to a number between 15 20 and the configuration does not work To correct the problem set the MIB attribute for the Generate XID field to 1 CR 35692 SNMP When you run Configuration Manager in dynamic mode the wfProtocols wfIPROTOLoad gets set to the value to which it is already set However the set does not affect service CR 72071 FDDI When you change a slot containing an FDDI module to Empty Slot Site Manager does not delete the following enhanced FDDI MIB objects from the configuration file wfFddiSmtExtEntry wfFddiSmtActionEntry wfFddiMacExtEntry wfFddiPathExtEntry wfFddiPortExtEntry and wfFddiPortActionEntry CR 35797 BGP Alt
41. ne is of type UDP or UNKNOWN and the other is RFC 1795 or RFC 1434 the router with the higher revision will fail to back down to the RFC 1795 router CR 34678 DLSw When a router receives an SSP Netbios NQ ex it logs it as a CANREACH ex CR 34682 LLC LLC2 traffic filter configuration does not work properly when you define a specific range for DSAP or SSAP values The fact that a RIF field is present is not taken into account when applying the filter to the packet CR 34684 APPN APPN over LANE does not work When a router sends a test poll to a second router the second router does not recognize the destination MAC address and does not forward the packet to APPN The MAC override should not just change the ESI portion of the NSAP address but should also change the actual hardware MAC address CR 34719 IP IP will not install BGP routes when the BGP NEXT_HOP has an unnumbered link as its next hop CR 34730 SNMP The WFTRAPS asn file shipped with Site Manager needs to be up to date with the current image version and the traps it supports Currently some of the events are missing CR 34738 DLSw When you disable DLSw on a router SDLC Link Stations remain up and continue to poll indefinitely 28 301894 B Rev 00 Release Notes CR 34740 Token Ring This is an enhancement request to increase the severity of following log message from DEBUG to either INFO or WARNING 188 07 10 97 05 06 05 292 DEBUG SL
42. ny information about the operation design performance or implementation of the Software and user manuals that is confidential to Bay Networks and its licensors however Licensee may grant permission to its consultants subcontractors and agents to use the Software at Licensee s facility provided they have agreed to use the Software only in accordance with the terms of this license 3 Limited warranty Bay Networks warrants each item of Software as delivered by Bay Networks and properly installed and operated on Bay Networks hardware or other equipment it is originally licensed for to function substantially as described in its accompanying user manual during its warranty period which begins on the date Software is first shipped to Licensee If any item of Software fails to so function during its warranty period as the sole remedy Bay Networks will at its discretion provide a suitable fix patch or workaround for the problem that may be included in a future Software release Bay Networks further warrants to Licensee that the media on which the Software is provided will be free from defects in materials and workmanship under normal use for a period of 90 days from the date Software is first shipped to Licensee Bay Networks will replace defective media at no charge if it is returned to Bay Networks during the warranty period along with proof of the date of shipment This warranty does not apply if the media has been damaged as a result of accident m
43. ogy from one router to another the topology may not transfer completely CR 35502 APPN When you activate an APPN link station a fault occurs because a buffer is freed incorrectly CR 35507 PPP If you have two routers connected via leased line and PPP using CHAP and the CHAP timer is set to 0 on one router and to 60 on the other the router with the timer set to 0 the receiver leaks memory Eventually that router runs out of memory and restarts CR 35523 ISDN A bus error occurs in a server one charge call ID configuration when the router callback server is going to set up the call CR 35525 DLSw If you boot a router that has DLSw Protocol Priority globally enabled and there is an ARE in the router an exception vector 2 MCP may occur CR 35568 Switched Services When you use a dial on demand asynchronous circuit you can only establish a connection twice The third time you try to connect you cannot ping across the dial on demand line 32 301894 B Rev 00 Release Notes CR 35571 DLSw A router cannot establish a DLSw session if that router has two peers that are terminated on an FDDI port CR 35611 BGP A VBM error may occur if BGP adds a new route while running on an ARE CR 35649 35650 DVMRP This is an enhancement request to add a log message indicating that the state of a DVMRP circuit has changed CR 35675 IPEX When you run a large number of IPEX sessions some sessions stop pas
44. onous PPP with a Hayes modem CR 34595 Router Redundancy If you configure one router interface for router redundancy the router checks only the first resource in the Router Redundancy Resource List for its availability via pings CR 34991 Firewall 2 FireWall performance degradation occurs as a result of a leakage fix that existed in phase 1 Performance suffers between 10 and 90 with a packet size of 64 bytes These numbers improve when the packet size is increased CR 35096 SDLC The SDLC code does not properly interoperate with the AS 400 high speed line controller with respect to flag streaming 301894 B Rev 00 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 35704 QLLC When a QLLC X25 end station receives a QUA in response to sending out a QDISC it is possible that the end station will not clear the X 25 call This causes the QLLC connection to not re establish because the QLLC router side expected the receiver of the QUA to clear the call CR 35739 IGMP When attempting to create 125 source group pairs some of the source group pairs do not have an outbound slot CR 35985 SDLC DLSw A DLSw connection does not properly recover after bringing down the SDLC line during flow control CR 71175 Switched Services If you have backup circuits configured setting the schedule parameter to any valid value has no functional effect When the primary circuit fails the backup circuit
45. opy the associated user manual solely in support of authorized use of the Software by Licensee This license applies to the Software only and does not extend to Bay Networks Agent software or other Bay Networks software products Bay Networks Agent software or other Bay Networks software products are licensed for use under the terms of the applicable Bay Networks Inc Software License Agreement that accompanies such software and upon payment by the end user of the applicable license fees for such software 2 Restrictions on use reservation of rights The Software and user manuals are protected under copyright laws Bay Networks and or its licensors retain all title and ownership in both the Software and user manuals including any revisions made by Bay Networks or its licensors The copyright notice must be reproduced and included with any copy of any portion of the Software or user manuals Licensee may not modify translate decompile disassemble use for any competitive analysis reverse engineer distribute or create derivative works from the Software or user manuals or any copy in whole or in part Except as expressly provided in this Agreement Licensee may not copy or transfer the Software or user manuals in whole or in part The Software and user manuals embody Bay Networks and its licensors confidential and proprietary intellectual property Licensee shall not sublicense assign or otherwise disclose to any third party the Software or a
46. ork The router generates an error in buf_float c at line 113 CR 74946 X 25 An X 25 PTOP circuit may remain operational in the UP state after powering off either a modem eliminator or a CSU DSU device connected to the port CR 74977 IPEX X 25 Gateway IPEX Gateway Mode fails to keep track of whether it reports the PVC in a down state or its peer reports the PVC as down Rather it accepts TCP opens even when the X 25 PVC is down preventing X 25 from transmitting packets properly CR 74991 IPEX X 25 Gateway When IPEX is in gateway mode and the TCP side of an IPEX session terminates it resets the X 25 side and then re establishes the TCP session But under heavy load the TCP session can be reestablished before X 25 has completed its reset causing synchronization problems between the two sides of the IPEX session 301894 B Rev 00 11 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 74993 IPEX X 25 Gateway IPEX in gateway mode does not send Reset 1d if the server side router s TCP open fails After booting both routers and if the server is down when the client attempts to establish an IPEX session the server side router should send a Reset 1d to the client side router to notify the client that the IPEX session failed The log files shows that IPEX sent a reset message to X 25 but X 25 failed to transmit it because X 25 was not in a data transfer state CR 75519 QOSPF Non self genera
47. proximately each 3 to 4 months after a Major Release occurs A Maintenance Release replaces the current Major Release or the prior Maintenance Release on the Price List and will become the current shipping version of BayRS Each Maintenance Release will be a consolidation of the prior bug fixes made through Revision Releases and will roll up all such software bug fixes provided by the recent Revision Releases Year 2000 Compliance BayRS Version 12 02 and Site Manager Software Version 6 02 are Year 2000 Compliance Certified by Bay Networks They have successfully passed Bay Networks Test Procedure which tests conformance to Bay Networks Year 2000 compliance definition both of which can be found at Bay Networks Year 2000 Web Site at http www baynetworks com year2000 Image Builder Operational Note If you are using Image Builder in Site Manager Software Version 6 10 to modify a BayRS Version 12 02 router image you will receive an error Please contact Bay Networks Customer Support to obtain the patch for this problem PC Site Manager READ ME FIRST File The contents of the PC Site Manager READ ME FIRST file are unreadable The complete text appears below PC Site Manager 6 02 README FILE Bay Networks Inc Copyright 1988 1998 All Rights Reserved SYSTEM REQUIREMENTS 486 PC Pentium recommended 2 301894 B Rev 00 Release Notes Microsoft Windows 95 16 MB of RAM minimum 60 MB of
48. rt CR 35143 DLSw If a NetBIOS client attempts to connect to an Ethernet LANE server or a token ring LANE server the router terminates operation CR 35177 DLSw BayRS is not fully compliant with RFC 1434 or RFC 1795 when operating with two half duplex TCP connections CR 35204 DLSw A bus error may occur in TCP when IP is bounced on a DLSw router CR 35268 DLSw When the router receives a multicast SSP NETBIOS NQ ex the ARE experiences several errors including an exception vector 5 VBM error CR 35328 ARE When you use IP traffic filters in ISP mode with the action set to Accept a bus error occurs if the filter is on an ATM ARE board CR 35361 IP A bus error may occur when you delete an access policy in the BCC if it was also created in the BCC CR 35414 IP In a multiline setup with three or more lines if one of the lines goes down the router may fail to resolve the far end host address via ARP 301894 B Rev 00 31 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 35428 DLSw When you run NetBIOS over DLSw Version 2 0 a panic may occur in dls_utils c as a result of a race condition when establishing connections CR 35447 IP The router intermittently returns a Fragmentation Needed but DF set ICMP Destination Unreachable message with an incorrect Next Hop MTU at the end of the ICMP header low order 16 bits CR 35494 APPN When you transfer an APPN topol
49. se agreement that may pertain to or accompany the delivery of this computer software the rights of the United States Government regarding its use reproduction and disclosure are as set forth in the Commercial Computer Software Restricted Rights clause at FAR 52 227 19 Statement of Conditions In the interest of improving internal design operational function and or reliability Bay Networks Inc reserves the right to make changes to the products described in this document without notice Bay Networks Inc does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein Portions of the code in this software product may be Copyright 1988 Regents of the University of California All rights reserved Redistribution and use in source and binary forms of such portions are permitted provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation advertising materials and other materials related to such distribution and use acknowledge that such portions of the software were developed by the University of California Berkeley The name of the University may not be used to endorse or promote products derived from such portions of the software without specific prior written permission SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED AS IS AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLI
50. sing data after several hours 10 to 15 The more hours IPEX is running the more sessions stop passing data The log shows no messages other than clock updates Statistics show that all X 25 IPEX and TCP sessions are still in active states CR 35685 IP When you use a regular expression for example 4 123 1247 2447 5432 amp in either BGP policy or ip bgp_routes R IP returns more matches than expected because the regular expression code incorrectly expands the I CR 35721 IPEX If the IPEX tcp_accept call fails the IPEX session is not cleaned up This causes IPEX sessions to remain in the TCPUP state CR 35798 BGP If you have multiple BGP connections to the same router and the BGP Collision Detect parameter is set to Disable the router drops one of the connections and logs a message stating that the connection was dropped because one exists CR 35878 DLSw DLSw interoperability fails with Cisco 11 3 and IBM routers running RFC 2166 301894 B Rev 00 33 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 35887 OSPF When you use an OSPF Announce Policy filter to aggregate a range of external networks the aggregated LSA may constantly refresh if a network within the range is unstable CR 35893 IP A router configured in ISP mode experiences a bus error within a few minutes following a reboot operation This happens before BGP imports the full routing table CR 35911
51. ted QOSPF Resource Reservation Advertisements RRA and Deterministic ABR Advertisements DABRA received from a neighbor were not flooded out to other neighbors causing the route pinning feature to fail CR 75484 DLSw During certain protocol exchanges DLSw connections can get stuck in CIRCUIT_PENDING and fail to recover until you reset DLSw or LLC or reboot the router CR 33106 MOSPF The router experiences a tag violation error causing it to fault under heavy traffic CR 33530 Telnet When there are many dynamic environment variables defined an outbound TELNET session hangs and freezes the entire Technician Interface session CR 34511 Translation Bridge Configuring translation bridge XB dynamically over TR LANE causes an Exception Vector 2 MCP error to occur on an ARE processor module CR 35570 PPP The IPX maximum frame size for a PPP link is calculated to be 4 bytes less than its required value CR 36062 DLSw An orphan buffer occurs when a DLSw connection is terminated 301894 B Rev 00 Release Notes CR 71025 DLSw DLSw causes an orphan buffer over ARE in DLSw version 1795 environment The DLSw peer is also running RFC 1795 CR 71423 QLLC A DLSw connection receives CANUREACH but will not generate an X 25 call to the adjacent host CR 71517 IPX An IPX Static Route is not properly installed in the router s IPX route table CR 71975 DLSw The DLSw connection fails to recover after
52. tion file in dynamic mode the router may have an error which prevents you from saving the file in either Site Manager or the Technician Interface CR 33424 BootP If there is not enough space in the vendor field of a BootP packet the following message is logged 2 09 12 97 14 03 03 410 DEBUG SLOT 2 BOOTP Code 8 Received request on interface 68 224 252 224 inserting subnet mask Not enough space in vendor field to insert subnet mask CR 32629 DLSw This is an enhancement request to support Remote Data Link Correlator Added wfDIsConnectionEntry wfDIsConnectionRemoteDLCorr which contains the Data Link Correlator CR 32752 FTP During an FTP session if you interrupt a command by entering Ctrl C an orphaned buffer fault may occur and the FTP session terminates CR 32779 QLLC After you reset the LLC base in a DLS QLLC environment you cannot reestablish a session between a PC3270 client and token ring host 301894 B Rev 00 23 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 32840 IPX In network configurations where a remote router uses group mode frame relay to connect to two different routers network costing may be set so that one of the local routers connected to the remote router s group mode frame relay will not have an IPX host entry for the remote router This causes all IPX pings from the remote router to fail It also causes IPX pings to the remote frame relay interface
53. warding decisions for self generated IP traffic CR 21299 APPN APPN parameters wfAppnNodePortMaxRcvBtuSize wfAppnNodePortMaxSendBtuSize in wfAppnNodePortEntry and wfAppnNodeLsMaxSendBtuSize in wfAppnNodeLsEntry need to be changed from 2057 to 1500 to accommodate the 1600 MTU size of a WAN port CR 23552 Switched Services If a dial on demand circuit is active in standby mode and you disconnect and then reconnect the BRI line the standby circuit connection is not properly reestablished CR 24390 ATM An MCP may occur after you dynamically change a Hybrid Mode PVC on an ATM interface CR 27324 ISDN This is an enhancement request to allow you to configure the number of times a router will attempt to register a SPID for basic rate ISDN with an ISDN switch The following parameters were added to wfIsdnLocalPhoneNumEntry wfIsdnSpidRetries wfIsdnSpidRetryAttempts wfIsdnSpidRetryTimer and wfIsdnSpidResetBri CR 27745 DLSw When you reset an IP interface on a DLSw router a bus error occurs 20 301894 B Rev 00 Release Notes CR 28088 IPX For IPX Route Filters the log message IPX Route Filter with rule number 1 includes rule number 2 on circ index 1 is generated despite the fact that the filters are configured correctly CR 28250 FTP When you transfer a file with a file name that starts with a numeric value to the router the router faults and receives orphan buffers CR 28589 BootP If
54. you configure DHCP on a multinetted interface the last IP address configured should become the DHCP gateway If you reboot the router the last configured IP address is no longer the DHCP gateway Instead another IP address on that interface becomes the gateway CR 29517 IPX If a router receives an IPX SAP packet on an interface with a network number that is different from the one for which the packet is destined the packet is not dropped CR 29813 ARP Routers fail to update the ARP table according to specifications in RFC 826 CR 30380 ATM An MCP error occurs when you disable and enable ATM signaling entities CR 30440 ISDN After you reset an ISDN BRI interface using the Technician Interface SPIDs get rejected 301894 B Rev 00 21 BayRS Version 12 02 and Site Manager Software Version 6 02 Release Notes CR 30591 DLSw There is no mechanism to display and monitor DLS and LLC2 connections on a per slot and per interface basis The following four MIB attributes were added wfDlsSlotCurrentSessions displays the number of DLSw connections on the slot that are ina CONNECTED state wfDIsSlotHi WaterSessions displays the maximum value reached by wfDIsSLotCurrentSessions since DLSw was enabled or since wfDIsSlotHi WaterReset was set to 2 wfLlcInterfaceCurrentLinks displays the number of links on the LLC interface wfLleInterfaceHiWaterLinks displays the maximum value reached by wfLIcInterfaceCurrentLinks since the LLC