1. 117 5 x 68 3 x 15 mm NOTE Refer to the TH11x user guide for techni cal specifications CT230 120GA 120GB 240GA 240GB Supply PB112 120 1800 W 120 VAC 60 Hz 15 A resistive PB112 240 3600 W 240 VAC 60 Hz 15 A resistive GFCI GA 5 mA GB 30 mA Certification c CSA us Size H W D BASE 4 63 x 2 7 x 1 45 in 117 5 x 68 3 x 37 mm Size H W D INTERFACE 4 67 x 2 74 x 0 67 in 118 6 x 69 6 x 17 mm Service If you have any questions concerning the installation of the master thermostat or slave units contact our technical support team at Montreal area 450 358 4600 Canada U S 1 800 831 AUBE 2823 Fax 450 358 4650 Email service aubetech com Monday to Friday from 8 30 AM to 5 00 PM EST For more information on our products visit us at www aubetech com Warranty AUBE TECHNOLOGIES INC ONE 1 YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a one year period following the initial date of purchase During this period AUBE Technologies Inc will repair or replace at our option and without charge any defective product which has been used under normal conditions The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation This warranty cancels and replaces any other manufacturer s express or implied warranty as well as any other company commitment A
2. The master thermostat controls a single or multiple floor heating zones driven by slave units The master thermostat can control up to 10 slave units Each slave unit drives its own zone and is equipped with a GFCI test button and warning light as well as an On Standby switch to facilitate maintenance on specific zones of the floor installation 2 Operation Master Thermostat The master unit controls the temperature and sends a signal to slave units when heating is required The floor sensor is connected to the master unit The master unit is powered by the slave units Slave Unit The slave unit receives the signal sent by the master unit and activates its load NOTE There must be a minimum of one slave unit ON to power the master unit 3 Installation Turn off power to the heating system at the main power panel to avoid electrical shock Installation should be carried out by an electrician 3 1 Wiring Guidelines The wire distance between the master thermo stat and slave unit should not exceed 500 ft 150 m e The floor sensor cable should not exceed 200 ft 60 m A 3 wire 20 AWG cable is recommended 3 2 Slave Units Installation and Wiring Installation Instructions MASTER THERMOSTATS TH113 A F AF 12VDC TH114 A F AF 12VDC TH115 A F AF 12VDC TH116 A F AF 12VDC SLAVE UNITS CT230 120GA CT230 120GB CT230 240GA CT230 240GB The slave units can operate on different voltages e g
3. 5 units 120 V and 5 240 V e Required parts CT230 120GA 120GB 240GA or 240GB Installation On an electrical box e Location Installation near the master thermostat is not required i e can be installed in a utility room e Wiring The power bases are joined through a daisy chain connection Connect the 120 V or 240 V power base wires to the power line and to the load floor using solderless con nectors for copper wires and secure the base to the electrical box Affix the wiring sticker in the CT230 box to the base Connect the slave power bases together as per FIGURE 1 Once installation and wiring is com plete mount the CT230 interface a Align the bracket tabs of the CT230 with the holes located on top of the power base b Secure the CT230 interface using the screw captive POWER Switch all slave power bases to STANDBY by sliding the protective door upwards and positioning the switch to STANDBY Install and connect the master unit see 3 3 UP TO 10 ey 12 VDC 12 VDC FIGURE 1 pave DRIVE Connections enn lo GND Q gt Sensor TH11X A F AF 12 VDC TH113 A F AF 12 VDC TH114 A F AF 12 VDC TH115 A F AF 12 VDC TH116 A F AF 12 VDC O O O CESAS 1 2 3 4 1 2 3 4 SS E
4. TH113 amp TH116 A F AF Owner s Guide Thank you for choosing Aube s non programmable thermostat Your new electronic thermostat is equipped with a microprocessor and proportional integral adaptive PIA temperature control technology for total comfort Depending on the selected model this thermostat has been designed to control A The Ambient temperature using an electric heating system AF The Ambient temperature with Floor temperature limit using a floor heating system to heat the room F The Floor temperature floor heating NOTE This control module must be mounted on a PB112 Series power base alia technologies The thermostat has an On Standby switch making it possible to put the thermostat in sleep mode when its use is no longer required e g summer O Control Module Installation Align the bracket tabs on the control module with the holes located on the power base Follow the same procedure for the TH116 Control module Power base NOTE Keep the thermostat s air vents clean and free from obstructions NOTE The screw cannot be removed completely ap Model Selection switch FOR A AND AF MODELS ONLY At the rear of the control module is a switch that has been factory set to the applicable temperature control NOTE The AF model can be used for all temperature control types A F and AF Floor Note The ambient Sensor sensor is not z operational
5. UBE Technologies Inc cannot be held liable for related or random damages following the installation of this product The defective product as well as the purchase invoice must be returned to the place of purchase or mailed prepaid and insured to the following address Aube Technologies Inc 705 Montrichard Saint Jean sur Richelieu Quebec Canada J2X 5K8 400 230 000 C 5 12 05 2 2
6. Y This product is guaranteed against workmanship defects for a one year period following the initial date of purchase During this period AUBE Technologies Inc will repair or replace at our option and without charge any defective product which has been used under normal conditions The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation This warranty cancels and replaces any other manufacturer s express or implied warranty as well as any other company commitment AUBE Technologies Inc cannot be held liable for related or random damages following the installation of this product The defective product as well as the purchase invoice must be returned to the place of purchase or mailed prepaid and insured to the following address Aube Technologies Inc 705 Montrichard Saint Jean sur Richelieu Quebec Canada J2X 5K8 If you have any questions concerning the TH113 or the TH116 thermostat call our technical support team at Phone Montreal area 450 358 4600 Canada U S 1 800 831 AUBE 2823 Fax y 450 358 4650 Email service aubetech com Monday to Friday from 8 30 AM to 5 00 PM EST For more information on our products visit us at www aubetech com 01 08 03 920 113 001 00 1 A aube technologies by par Honeywell 1 Introduction This master and slave unit system is specially designed for large floor heating applications exceeding 15 A
7. e notch points to the desired temperature The TH113 and TH116 are equipped with a remote input which allows connection of an optional telephone controller CT240 or any other remote control system When a command signal is received through this input the thermostat automatically lowers its setpoint by 3 5 C The LED lights up to indicate the signal s presence except for GA and GB models Bypass not available for GA and GB power base The TEST button can be used to bypass the signal for a 2 hour period The LED goes off to indicate the bypass NOTE When combined with a GA GB power base the TEST button is used only for GFCI testing The bypass function is not available with these power base models Technical Specifications Models TH113 and TH116 A AF F Setting range 45 F 59 F to 95 F 7 C 15 C to 35 C Potentiometers minimum 41 F to 77 F 5 C to 25 C maximum 59 F to 95 F 15 C to 35 C Accuracy 0 9 F 0 5 C Storage 4 F to 120 F 20 C to 50 C Setpoint Definition Turn the dial to the desired temperature TH113 The dial is located on the front of the control module TH116 The dial is located on the rear of the control module The min position indicates the minimum temperature setpoint 45 F 7 C Temperature dial Test ON kia a Warranty AUBE TECHNOLOGIES INC ONE 1 YEAR LIMITED WARRANT
8. tof I tot GQ G Gp D oOo gf zZz D N Z Z J b 2 oO VU oO O m g m i 2 CT230 XXXXX CT230 120GA CT230 120GB CT230 240GA CT230 240GB an9 JA40 IMN 400 230 000 C ano gt 5 12 05 1 2 3 3 Master Thermostat Installation and Wiring WARNING Make sure all slave units are in STANDBY mode Required parts TH113 A F AF 12VDC TH114 A F AF 12VDC TH115 A F AF 12VDC or TH116 A F AF 12VDC Location anywhere easily accessible to users Temperature control AF ambient with floor limit A ambient e Install the master thermostat in the controlled area e Choose a location about 5 ft above the floor in an area where the tempera ture is stable e Avoid locations where there are air drafts top of staircase air outlet dead air spots behind a door direct sunlight or concealed chimneys or stove pipes Temperature control F floor Can be installed anywhere Wire the 12 VDC base to the nearest slave unit The floor sensor must be installed in an area where average temperature can be read The cable must follow the wall down to the floor and must not cross any heater wires or be directly on or adjacent to a heating wire For maximum performance the sensor probe should be centered between the wires in the mat max 80 C Push the excess wire into the wall secure the base using the provided screws and wall anchors and install the TH11
9. when the switch is set to up Ambient sensor Floor Switch sensor 3 A i O GFCI Test ca amp GB power base only The GFCI monitors the electrical flow for any loss of current if there is any loss the thermostat will cut off power to the heating system We recommend you test the GFCI immediately after installing the control module and once a month thereafter to ensure it is operating properly To test Press the TEST button Successful TEST warn ing light is ON and power to heating system is cut off Unsucessful The TEST warning light is OFF Cut power to heating system from the main power panel and call customer service When successful reset thermostat GSTANDBY ON to power heating system NOTE If the test warning light comes ON during normal operation cut power to heating system from the main power panel and have an electrician verify the installation 2 Temperature Lock TH113 only At the rear of the control module are two potentiometers These potentiometers act like a temperature lock Even when occupants adjust the temperature using the dial on the front rear of the control module the potentiometers override the dial and maintain the temperature within the locked in minimum and maximum range gt A ambient temperature gt F amp AF floor temperature limit Use a flat tip screwdriver to rotate the potentiometers until th
10. x thermostat onto the base Once the thermostat is installed return power to heating system and switch all slave units and the master thermostat to ON 3 4 Slave Units GFCI Test We recommend you test the GFCI immediately after installing the thermostat and once a month thereafter to ensure it is operating properly If the test warning light comes ON during normal operation cut power to heating system from the main power panel and verify the installation Slide the protective door upwards and make sure the switch is ON Press TEST e The test is successful if the TEST warning light is ON and power is cut off e Ifthe test fails first installation test a Verify installation b Check the load wires c Once you ve identified the problem run the GFCI test again e Ifthe test fails monthly maintenance a Cut power to heating system from the main power panel and call customer service When the test is successful reset the slave unit by switching from ON to STANDBY then back to ON Repeat steps 1 to 3 for all slave units Technical Specifications Temperature Operation 32 F to 122 F 0 C to 50 C Storage 4 F to 122 F 20 C to 50 C TH113 TH114 TH115 TH116 A F AF 12VDC Power supply 12 V from remote unit Maximum up to 10 slave units per slave units master thermostat Wire gauge 20 AWG Size H W D BASE 4 63 x 2 7 x 0 61 in