Home
AMX MET-6N User's Manual
Contents
1. an F Overview The MET 6N Metreau 6 Button Keypad with Navigation FG5794 01 features source control a navigation wheel that adjusts levels and provides up down left right and select button options as well as an LED bar for visual level feedback The MET 6N can be used as in individual keypad or in conjunction with the MET 7 and MET 13 keypads FIG 1 6 pre printed pushbuttons _ gt with blue LED indicators IR Sensor located here gt supports AMX IR 38kHz LED Bargraph provides level feedback Navigation Wheel amp pushbuttons ee FIG 1 MET 6N Metreau 6 Button Keypad with Navigation The MET E6N is an AxLink keypad suitable for use in NetLinx Control Systems Specifications MET 6N Specifications Front Panel Pushbuttons 6 tactile pushbuttons with blue LED indicators that Components illuminate when pressed to confirm the source function was selected and that it is currently being used These pre printed buttons are field replaceable IR Sensor Supports standard AMX IR 38 kHz only LED Levels Indicator set of 7 blue LEDs provide level feedback Navigation Wheel consists of 5 pushbuttons 4 directional pushbuttons Up Down Right Left 1 center pushbutton and bi directional rotating wheel for channel adjustments The Navigation wheel itself provides two button functions as well rotate CW button 12 and rotate CCW button 13
2. firmware transfers NetLinx Studio 2 is available for free download from www amx com 1 Open NetLinx Studio2 2 Goto Tools gt Firmware Transfers gt Send to Axcess Device This opens the Send to Axcess Dialog Window Browse to the location of the firmware file Select the file within the Files frame Click Query for Devices 6 Select the Metreau keypad within the Devices frame The MET E6N will appear as two devices in the Devices frame because it s built in IR Receiver is recognized as a separate online device The Device Address of the IR Receiver is always one number higher than the device number of the keypad itself to which the firmware is uploaded For example if the MET 6N is set to device number 127 then the IR Receiver on that MET 6N will appear as device number 128 Firmware must be sent to the keypad not the IR Receiver in this example device 127 7 Click Send and then Close 8 Upon confirmation of a successful send you can exit NetLinx Studio2 oa 93 5794 01 REV B UU ILL TL BPD
3. IP switch positions that are in the ON position Note that the ON position is indicated on the DIP Switch As an example the DIP switch in FIG 4 defines AXLink device number 129 1 128 129 If you later change the device number remove and reconnect the power connector to enter the new device number into memory Wiring Preparing captive wires Caution Do not connect power to the Metreau keypad until the wiring is complete Caution If using power from AxLink disconnect the wiring from the control system before wiring the Metreau keypads You will need a wire stripper and flat blade screwdriver to prepare and connect the Captive wires 1 Strip 0 25 inch 6 35 mm of wire insulation off all wires 2 Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section 3 Turn the flat head screws clockwise to secure the wires in the connector Note Do not over torque the screws doing so can bend the seating pins and damage the connector Wiring guidelines Metreau keypads require 12 VDC power to operate properly The necessary power is supplied via the AxLink or SWT cable The maximum wiring distance is determined by power consumption supplied voltage and the wire gauge used for the cable The following table lists wire sizes and the maximum lengths allowable based on the maximum power consumption rating of 170 mA AxLink Wiring Guidelines at 170 mA Maximum Wi
4. Navigation Wheel The Navigation Wheel itself can be rotated clockwise and counterclockwise and is intended to provide level control for example volume or lighting levels e When rotated clockwise the Navigation Wheel provides a channel event on button 12 e When rotated counter clockwise the Navigation Wheel provides a channel event on button 13 e The light on the Navigation Wheel can be illuminated by activating channel 11 Installation Note Before touching the device discharge the static electricity from your body by touching a grounded metal object FIG 3 shows the basic rear components of the MET 6N keypads not used gt i AxLink connector from NetLinx Controller Device Address DIP Switch a wi me not used iE a not used FIG 3 MET 6N Rear Components AxLink Device Addressing AxLink enabled Metreau keypads use an 8 position mini DIP switch to specify a unique device address for each keypad in a NetLinx Control System Note Before touching the device discharge the static electricity from your body by touching a grounded metal object 1 If connected disconnect the power supply 2 Locate the 8 position mini DIP switch on the rear panel see FIG 3 3 Set the DIP switch according to the values shown in FIG 4 switch 1 2 3 4 5 6 7 8 Example 129 Vae 1 2 4 8 16 32 64 128 FIG 4 8 position mini DIP Switch The device number is set by the total value of D
5. as indicated in FIG 2 DIP switch 8 position mini DIP switch used to set the device address for the keypad on the AxLink Bus 1 255 AxLink connector 4 pin 3 5mm Phoenix connector for AxLink connection to the NetLinx Master Keypad and Mounting Plate 4 055 x 1 772 x 0 997 103mm x 45mm x 25 32mm Mounts into standard decora style wall plates Twat 2toe C8049 Operating Operating Temperature 32 104 F 0 40 C Environment Relative Humidity 5 85 non condensing Intended for indoor use only FCC Class B CE IEC60950 RoHS White FG5794 01 WH Black FG5794 01 BL Light Almond FG5794 01 LA Single Button Kit FG5794 10 Lutron Cairo Wallplates available in a variety of sizes and colors Rear Panel Components Dimensions HWD Certifications Optional Accessories Installation Guide MET 6N Metreau 6 Button Keypad with Navigation p Navigation Wheel Pushbuttons The top bottom left right and center points on the Navigation Wheel are pushbuttons that provide events on Channels 7 8 9 10 and 11 and can be programmed like any other AxLink button FIG 2 shows the button layout of the Navigation Wheel Directional pushbutton UP Rotate clockwise button 12 Rotate counter clockwise button 13 Directional pushbutton RIGHT Directional pushbutton LEFT Center pushbutton Directional pushbutton DOWN FIG 2 Navigation Wheel button layout
6. k and 12 VDC power supply wiring diagram Metreau keypad Note If you are not using power from AxLink disconnect the wiring from the controller before wiring the Metreau keypad Make sure the auxiliary power supply s PWR is not connected to the controller s AxLink connector AxLink Status LED The AxLink Status LED located next to the AxLink connector lights to indicate AxLink power data status see Operation Reference Guide for details If the LED is on and not flashing disconnect the AxLink connector and recheck all AxLink connections Then reconnect the AxLink connector to the panel and verify the LED is flashing once per second Mounting Procedures AMX recommends mounting Metreau keypads in standard U S style decora wallboxes e Conduit box should meet NEC specs section 370 e Minimum internal clearance of HWD 2 5 8 x 1 3 4 x 1 5 8 Note Before touching the device discharge the static electricity from your body by touching a grounded metal object For full warranty information refer to the AMX Instruction Manual s associated with your Product s 1 08 2008 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 e 800 222 0193 e fax 469 624 7153 technical support 800 932 6993 www amx com Wallbox Mounting 1 Use the cutout dimension for the wallbox to c
7. ring Length 690 42 feet 210 43 m 20 AWG 436 80 feet 133 13 m 22 AWG 272 33 feet 83 00 m 24 AWG 171 66 feet 52 32 m The maximum wiring lengths for using AxLink power are based on a minimum of 13 5 volts available If the distance is greater than what is listed in the table consult the Metreau Keypads Operation Reference Guide for wiring with external power sources AxLink Data and Power Connections Connect the control system s AxLink connector to the AxLink connector on the rear panel of the Metreau Keypad for data and 12 VDC power as shown in FIG 5 18 AWG PWR A LP AXP 1 AXP AXM AXM GND GND Metreau Keypad Control System FIG AxLink straight thru wiring Using AxLink for Data with an Auxiliary Power Supply Use an auxiliary 12 VDC power supply when the distance between the controller and server exceeds the limits described in the Wiring guidelines section Connect only the GND wire on the AxLink connector when using an auxiliary 12 VDC power supply Connect the NetLinx Controller s AxLink connector to the AxLink connector on the rear panel of the Metreau keypad as shown in FIG 6 12 VDC power supply PWR GND PWR LI PWR AXP T4 L AXP AXM AXM GND GND NetLinx Controller FIG 6 AxLin
8. utout the install surface 2 Connect the AxLink connector or SWT cable connectors to the rear of the keypad 3 Place the Mounting Plate on the wallbox align the screw holes with the mount ing holes and fasten the Mounting Plate to the wallbox using the screws sup plied Note Do not overtighten the screws when mounting the Mounting Frame The device should be flush with mounting surface Mounting Dimensions FIG 7 provides detailed dimensions for the 6 button Navigation Wheel keypads O83 C1480 Lite C45 00 J o247 LAET Le den dand Cis J Oe33 Ciel J Ogg 253 FIG 7 Mounting Dimensions MET 6N NetLinx Programming DEVICE IDs The MET 6N utilizes two distinct Device IDs One for the device itself and another for the IR Sensor Programming the Navigation Wheel The Navigation wheel on the MET 6N can be treated from a NetLinx programming perspective as 5 distinct pushbuttons plus Channel up and down The button layout for the Navigation Wheel is indicated in FIG 2 SEND_COMMANDs There are a select number or SEND_COMMANDs the Metreau keypad recognizes For a full list and descriptions consult the Metreau Keypads Operation Reference Guide Sending Firmware to Metreau Keypads AxLink The Firmware on the AxLink enabled Metreau keypads MET 6N MET 7 and MET 13 can be updated via the NetLinx Studio2 application Note Refer to the NetLinx Studio 2 online help for additional details on
Download Pdf Manuals
Related Search
Related Contents
16250 GA_LifeTech.QXP:GA Juin 2013 - Association des conseils en gestion linguistique SC-450 System Controller Oxyguard PPB OPERATION INSTRUCTIONS AND USER`S MANUAL Sony VGC-RC210G User's Guide Telfort Mobile Internet Software User Manual Hyperion eos-0615iDUO3-manual-Deutsch Iolite 3 User`s Manual Thermo Scientific APEX 500 Rx Metal Detector User's Guide Copyright © All rights reserved.