Home
American Standard Centerset Lavatory Faucet with SpeedConnect Drain 1480.110 User's Manual
Contents
1. Americam Standard Installation Instructions SEVA 1480 110 Centerset Lavatory Faucet with 1480 115 SpeedConnect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Speed Connect Drain e Fewer parts installs in less time Certified to comply with ANSI A112 18 1 e Never needs adjustment M968305 REV 1 1 e Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the Speed Connect drain Heplful tips for removing your current drain can be found in the Troubleshooting section of these instructions To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Required tools Screwdriver Channel Locks Adjustable Wrench Tubing Cutter INSTALL FAUCET main supply Turn off hot and cold water supplies before beginning Note Putty is not required unless mounting surface is uneven Apply a bead of PUTTY along the edge of the underside of the BODY 1 if required Insert FAUCET 4 and CABLE CONNECTOR 2 through mounting holes of Sink or mounting surface Fig A Assemble LOCKNUTS 3 onto SHANKS 4 from under side of Sink Hand tighten firmly Fig B HAND TIGHTEN PUTTY IF REQUIRED SINK OR MOUNTING SURFACE POP UP DRAIN Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under D
2. RAIN POP UP 3 Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B I ey il REMOVE FLANGE Thread FLANGE 1 counter clockwise and remove FLANGE 4 and FOAM GASKET 2 from drain body Fig A Thread LOCKNUT 3 clock wise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE From under side of SINK Tighten LOCKNUT 1 firmly with Adjustable install DRAIN BODY 1 up Wrench or Channel Locks through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly FLANGE GASKET AND POP UP KNOB Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A m POP UP KNOB 1 must be fully down Fig B WHITE FOAM GASKET DRAIN NOT VISIBLE FLANGE M968305 REV 1 1 ATTACH CABLE CONNECTOR Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 O D Fig B CHECK OPERATION OF POP UP Operate LIFT KNOB 11 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these in
3. structions MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS MUST BE PURCHASED SEPARATELY Connect water supply to FAUCET 4 with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect 1 1 4 O D tailpiece on POP UP DRAIN to 1 2 PIPE l waste outlet THREAD 3 FLEXIBLE SUPPLIES 3 8 COMPRESSION CONNECTION COUPLING NUT 3 8 O D BULL NOSE RISERS COMPRESSION NUT FERRULE M968305 REV 1 1 TEST INSTALLED FITTING With HANDLE 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks Remove AERATOR 3 Operate both HANDLE 1 to flush water lines thoroughly Replace AERATOR 3 CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions Release POP UP KNOB 4 down and check all drain connections and P trap for leaks Tighten mp if necessary SERVICE By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold the HOT LIMIT SAFETY STOP reduces risk of accidental scalding To set
4. the maximum hot water temperature of your faucets all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP Loosen SET SCREW 2 with 2 5mm hex wrench Pull HANDLE 1 off valve stem Pull off CAP 3 Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP 4 Follow Step A or B to adjust min max discharge temperature O being the hottest to 7 the coldest temperature setting Factory set at 0 Replace ESCUTCHEON CAP 3 eee taeda HANDLE 1 tighten HANDLE A AND ROTATE COUNTER SCREW 2 CLOCKWISE ONE CLICK A A TEMPERATURE IEN SETTING NUMBERS 7 gt a B ADJUSTMENT WHEN PRY RED RING FORWARD WATER IS TOO HOT AND ROTATE CLOCKWISE lt B ADJUSTMENT WHEN WATER IS TOO COLD RED RING HOT LIMIT SAFETY STOP 1 2 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE 4 M968305 REV 1 1
Download Pdf Manuals
Related Search
Related Contents
User`s Guide - Proma GAMESS-UK USER'S GUIDE and REFERENCE MANUAL Version 201103_Cover Story_A4カタログ Manual del usuario File - ULM Technologie 580 et 590 Série L MB629-3224 明電産業用スイッチングハブ MEISWAY TW900 Copyright © All rights reserved.
Failed to retrieve file