Home

Allied Telesis Patch sr264-03 User's Manual

image

Contents

1. 2 The L3 filter nomatchaction parameter was not applied for some IP traffic on the switch This issue has been resolved PCR 40405 Module ENCO Level 2 If the ENCO process used to encrypt an ISAKMP packet failed a switch reboot could occur This issue has been resolved PCR 40415 Module VRRP Level 2 When a master VRRP router was configured from a boot script the transition to the MASTER state occurred before the Layer 2 interface had been initialised preventing the gratuitous ARP from being sent This issue has been resolved Patch sr264 03 for Software Release 2 6 4 C613 10407 00 REV C Patch sr264 03 for AT 8600 series switches 3 Patch sr264 03 for Software Release 2 6 4 C613 10407 00 REV C PCR 40417 Module OSPF Level 3 When LS Acks Link State Advert acks were received they were compared against the transmitted LSA Link State Advert If it was the same the LSA was removed from the re transmission list The algorithm used in this check has been changed to be compliant with the algorithm specified in section 13 1 of RFC2328 to determine if the LS Ack received is the instance as the LSA PCR 40440 Module CLASSIFIER Level 3 For those classifiers that specified the IP protocol as a match criterion the IP protocol number was being stored and displayed ina configuration file as a hexadecimal value rather than a decimal value This issue has been resolved PCR 40441 Module IPG VRRP Level 4 If VRRP wa
2. Release 2 6 4 C613 10407 00 REV C
3. Patch Release Note Patch sr264 03 for AT 8600 series switches Introduction This patch release note lists the issues addressed and enhancements made in patch sr264 03 for Software Release 2 6 4 on existing models of AT 8600 series switches Patch file details are listed in Table 1 Table 1 Patch file details for Patch sr264 03 Base Software Release File st 264 rez Patch Release Date 30 July 2004 Compressed Patch File Name sr264 03 paz Compressed Patch File Size 40912 bytes This release note should be read in conjunction with the following documents E Release Note Software Release 2 6 4 for AT 8600 Series switches Document Number C613 10404 00 REV A available from www alliedtelesyn co nz documentation documentation html m AT 8600 Series Switch Documentation Set for Software Release 2 6 4 available on the Documentation and Tools CD ROM packaged with your switch or from www alliedtelesyn co nz documentation documentation html WARNING Using a patch for a different model or software release may cause unpredictable results including disruption to the network Information in this release note is subject to change without notice and does not represent a commitment on the part of Allied Telesyn International While every effort has been made to ensure that the information contained within this document and the features and changes described are accurate Allied Telesyn International can not accept any type of lia
4. authenticator to perform authentication message exchanges or access services not controlled by the authenticator s controlled port Initial 802 1x control begins with an unauthenticated supplicant and an authenticator A port under 802 1x control acting as an authenticator is in an unauthorised state until authentication is successful 1 Either the authenticator or the supplicant can initiate an authentication message exchange The authenticator initiates the authentication message exchange by sending an EAPOL packet containing an encapsulated EAP Request Identity packet The supplicant initiates an authentication message exchange by sending an EAPOL Start packet to which the authenticator responds by sending an EAPOL packet containing an encapsulated EAP Request Identity packet 2 The supplicant sends an EAPOL packet containing an encapsulated EAP Response Identity packet to the authentication server via the authenticator confirming its identity 3 The authentication server selects an EAP authentication algorithm to verify the supplicant s identity and sends an EAP Request packet to the supplicant via the authenticator 4 The supplicant provides its authentication credentials to the authenticator server via an EAP Response packet 5 The authentication server either sends an EAP Success packet or EAP Reject packet to the supplicant via the authenticator 6 Uponsuccessful authorisation of the supplicant by the authenticator ser
5. bility for errors in or omissions arising from the use of this information MVE Allied Telesyn Simply connec ting the world Patch Release Note Some of the issues addressed in this Release Note include a level number This number reflects the importance of the issue that has been resolved The levels are Level1 This issue will cause significant interruption to network services and there is no work around Level2 This issue will cause interruption to network service however there is a work around Level3 This issue will seldom appear and will cause minor inconvenience Level4 This issue represents a cosmetic change and does not affect network operation Features in sr264 03 Patch sr264 03 includes all issues resolved and enhancements released in previous patches for Software Release 2 6 4 and the following enhancements PCR 31225 Module IPG Level 3 While the switch was set with a CIDR interface address when it received an ECHO request with a network broadcast destination address for a class C network the switch sent the ECHO reply packet Also the switch forwarded the ECHO request packet using a broadcast MAC address These issues have been resolved PCR 40355 Module VRRP Level 2 When an IP interface is in a down state and VRRP is configured on the interface VRRP should be disabled If it was enabled VRRP could transition to INITIAL state This issue has been resolved PCR 40357 Module SW56 Level
6. removed prior to release 2 6 4 This issue has been resolved PCR 40374 Module PORTAUTH USER UTILITY Support has been added for EAP types TLS TTLS and PEAP when the switch is acting as an 802 1x authenticator See The Authentication Server on page 5 for more information PCR 40414 Module TM CORE Level 3 Factory Autoburn test caused a switch reboot when BIST started to run This issue has been resolved Patch sr264 03 for Software Release 2 6 4 C613 10407 00 REV C Patch sr264 03 for AT 8600 series switches Patch sr264 03 for Software Release 2 6 4 C613 10407 00 REV C The Authentication Server The authentication server verifies the supplicant s details passed to it by the authenticator This implementation of 802 1x control requires that a port acting as an authenticator must communicate with a RADIUS authentication server The RADIUS server must be capable of receiving and deciphering EAP in RADIUS packets The authentication server must be connected to a port on the switch which does not have port authentication enabled or is set with CONTROL AUTHORISED The supported supplicant encryption mechanisms for communication with the RADIUS server are EAP MD5 and EAP OTP With this enhancement the encryption methods supported by authenticators are EAP MD5 EAP OTP EAP TLS EAP TTLS and EAP PEAP Steps in the Authentication Process Until authentication is successful the supplicant can only access the
7. s enabled and a reset ip command was issued followed by a disable vrrp command then the device would still reply to pings even though the device was no longer the VRRP master Duplicate echo replies were seen on the device sending the pings This issue has been resolved PCR 40446 Module DHCP Level 2 In certain situations if a DHCP client used a DHCP relay agent to request IP addresses from the switch acting as the DHCP server on a different subnet it was not be able to renew the IP address allocated to it This issue has been resolved PCR 40447 Module CORE SWI SW56 Support was added for new fibre uplink modules A45SC A45SCSM and GBIC uplink module A47 PCR 40453 Module IPG Level 2 Particular IP packets unicast destination IP but multicast destination MAC could result in a memory leak which in some cases could cause the device to stop responding to the command line This issue has been resolved Patch Release Note Features in sr264 02 Patch file details are listed in Table 2 Table 2 Patch file details for Patch sr264 02 Base Software Release File st 264 rez Patch Release Date 06 July 2004 Compressed Patch File Name sr264 02 paz Compressed Patch File Size 9288 bytes Patch sr264 02 includes the following resolved issues and enhancements PCR 40360 Module SWITCH Level 3 Factory LED tests enable disable switch led test for AT 8800 series switches only and enable disable switch stpf were
8. ver a port under 802 1x control is in an authorised state unless the MAC associated with the port is either physically or administratively inoperable Also upon successful authorisation of the supplicant by the authenticator server the supplicant is allowed full access to services offered via the controlled port If piggybacking is enabled on the authorised authenticator port any other device connected will also be give full access 6 Patch Release Note 7 When the supplicant sends an EAPOL Logoff message to the authenticator the port under 802 1x control is set to unauthorised A successful authentication message exchange initiated and ended by a supplicant using OTP authentication is shown in below messages to an Authenticator Port Access Entity PAE from a third party A To minimise the risk of denial of service attacks by issuing EAPOL Logoff device we recommend that 802 1x not be used in a shared media LAN Figure 1 Authentication Messaging Exchange Initiated by the Supplicant Supplicant PAE Authenticator PAE aal EAP Request Identity EAP Response Identity Steet sesecseuseeacseeadeeuos gt Exchange of EAPOL frames Exchange of EAP frames carried by RADIUS 8021X5 Availability Patches can be downloaded from the Software Updates area of the Allied Telesyn web site at www alliedtelesyn co nz support updates patches html A licence or password is not required to use a patch Patch sr264 03 for Software

Download Pdf Manuals

image

Related Search

Related Contents

USER'S MANUAL OF UNDERSTYLE  取扱説明書 兼 無償修理規定  IP-PBX との連携で 効率的な検索を実現!  WHOLE HOUSE HUMIDIFIER  Read All Instructions In This Manual And Component Part  Samsung SRS705IC User Manual  none 93033ORB Use and Care Manual  Française - Food and Agriculture Organization of the United Nations  View - Logistics Management Division  User Guide - Nurse Rosie Products  