1. Special Ord 2 AIPHONE oE MYW BA M Long Distance Video Adaptor For MY Monitors INSTRUCTIONS The MYW BA M adaptor extends the distance between the first and last monitor in an MY video entry system to 1000 feet Any video system using the MYH CU or MYH CUB sub monitors along with an IE LEF or TD H audio intercom can be used Aiphone cable 851602 is required for the video signal WIRING DIAGRAMS 1 USING MY CU and MYH CU with IE or TD H Audio Audio system not shown MK DAC Max 509 851602 Aiphone Low capacitance 16AWG Wire 851602 MYW BA M PE insulated wire Aiphone Wire 851602 MYH CU VIDEO DOOR STATIONS Any Aiphone MK or MY Series video door station can be used MK DAC Surface mount black MK DBC Semi flush mount black MK DGC Semi flush mount metal cover MY DGV Semi flush mount vandal proof stainless steel cover MK DS B Surface mount fixed camera n i Wire 841806 Wire 841 806 wires doubled wires doubled Total 1000 Individual Components for System NOTE MYW BA M Long distance adaptor for MY monitors A separate audio intercom system is required MY CU Master monitor surface mount for proper system operation Select the MYH CU Sub monitor surface mount appropriate system based on overall distance MYH CUB Sub monitor flush mount and communication requirements MYW P1L Single camera adaptor for LEF system BA 3 MYW P3L Three camera adaptor for LEF sy
2. bled Total 1000 SPECIFICATIONS Power Source 18V DC Use PS 18C for every three video units including adaptor and monitors Current consumption 250 mA standby Scanning lines 525 lines Wiring distance MK Camera to MY CU or MYW adaptor Max 330 with 18 AWG wire MY CU or MYW adaptor to MYW BA M Max 500 with Aiphone cables 841806 amp 851602 Max distance from first to last MY monitor is 1000 with Aiphone cables 841806 amp 851602 Total distance from first monitor adaptor to farthest sub monitor cannot exceed 1000 feet Dimensions 7 1 2 H x 3 W x 1 5 8 D CAUTION Do not connect any AC wires to any terminal on any unit as damage may occur Connect only specified power source to and terminals Do not install more or different power sources than specified for the system Do not attempt to install or connect wires on the MY system while the system s power supply is plugged in i MY monitors and related equipment unless specified as weather resistant are designed for indoor use only Video door stations MK DAC MK DBC MK DGC MK DS MY DGV may be installed outdoors in a protected area Do not expose i any equipment directly to rain or extreme weather conditions IMPORTANT Any other manufacturer s products installed with the system power supply external device etc are not covered under Aiphone s warranty Do not mount Aiphone equipment in the following places as it may cause t
3. he system to malfunction High or extreme cold temperature areas under direct sunlight near equipment that varies in temperature in front of air conditioner inside a refrigerated area etc Places subject to moisture or humidity extremes i Places subject to environmental conditions such as dust oil chemicals salt etc All intercom and video units are electronic devices which must not be subjected to water or any other liquid Severe weather conditions such as lightning storms may cause damage to Aiphone equipment We recommend that power surge protection be installed to minimize potential component level damage Install the SA 1 surge arrestor to protect the power supply from a surge Additional SA 1 surge arrestors should be installed on all communication lines one SA 1 for every two connected to master Aiphone Communication Systems Toll Free Technical Support 1700 130th Ave N E Bellevue WA 98005 1 800 692 0200 Pg 2 425 455 0510 FAX 1 800 832 3765 MYW BA M Instr FAX 425 455 0071 E mail tech serv aiphone com 0703bkjs
4. stem MYW BA M TERMINAL DEFINITIONS PS 1820UL 18V DC 2A Power Supply AI Video signal input from IE 1GD 1 Door 4 Room master handset a MY monitor adaptor IE 2AD 2 Door 4 Room Master handset B1 Output to IEH 1CD Sub handset for IE 1GD and IE 2AD B2 s b m nit rs IE 8MD 2 Door 6 Room master handset IE 8HD Sub handset for IE 8MD LEF 5 5 call open voice master surface or desk mount A reas Ye P LEF 10 10 call open voice master surface or desk mount rg ia SU MORNO LEF 10S 10 call open voice master with All call button surface desk mount 4 Positive 18V DC LEF 5C 5 call open voice master Semi flush mount Negative LEF 10C 10 call open voice master Semi flush mount Pg 1 2 MYW P3L with MYH CUB and LEF C Audio Audio system not shown MK DAC MYW P3L NOTE An audio intercom system is required for proper system operation Select the appropriate system based on overall distance and communication requirements Max 500 Wire 851602 MYW BA M mn Wire 851602 MYH CUB A i VIDEO DOOR STATIONS Any Aiphone MK or MY Series video door station can be used MK DAC Surface mount black MK DBC Semi flush mount black MK DGC Semi flush mount metal cover MY DGV Semi flush mount vandal proof stainless steel cover MK DS B Surface mount fixed camera PS 1820UL PS 1820UL i i i i i i onnect i Wire 841806 Wire 841806 wires doubled wire dou

Download Pdf Manuals

image

Related Search

Related Contents

Philips HD2393    PORTÉGÉ M800  Manual De Instalacion PUHZ-SHW80-140 Mitsubishi Electric Aire  User Manual - Sütron electronic GmbH  Manual de Instrucciones  User`s manual. Accelerometer. Applicability.  ABUS Secvest 2WAY  Fisher-Price C5843 Instruction Sheet    

Copyright © All rights reserved.
Failed to retrieve file