1. r a AASTRA A Tel com J www aastra com ATP CNX 020 Document Revision 01 06 Aastra CNX Conference Network Switch Release 1 2 July 2005 ey Aastra CNX Conference Network Switch Installation and Setup Guide AASTRA Telecom Aastra Aastra Telecom and the Aastra Telecom corporate logo are registered trademarks of Aastra Technologies Limited Microsoft Microsoft Windows and Internet Explorer are trademarks of Microsoft Corporation NFS Sun SunOS Java JavaHelp Solaris and Sun Microsystems are trademarks of Sun Microsystems Inc Ethernet is a registered trademark of Xerox Corporation Inc UNIX is a registered trademark in the United States and other countries licensed exclusively through The Open Group All other third party trademarks and registered trademarks are the property of their respective owners 2005 Aastra Technologies Limited All rights reserved Information in this document is subject to change without notice Aastra Technologies Limited assumes no responsibility for any errors that may appear in this document Published in the USA Contents Warranty regulatory safety and copyright licensing notices Waranty Aasta Telecom WiC san den OA V Waranty LIMON si issssscerudeseenrenenecn sanspet eles aa v Regulatory TAHT UNO srini Sona ii anced bas seed ls rE EE a aaa vi USA QUIP wccasacceciecnduceeviasaassssersacusssast Gola dusttianiiaeoihyeliasderaaam acer cenueeigeepsereu vi C
2. Default Gateway 192 168 2 1 Is this correct y n 8 Enter y if the network information is correct and press lt Enter gt won Enter n if the network information is incorrect and press lt Enter gt wos Note If you entered n at the verification prompt repeat steps 3 through 7 to correct the network 6 information and then enter y at step 8 The following message and prompt display after entering y at the verification prompt Configuring Domain Name Service DNS Domain Name 10 continued ATP CNX 020 Rel 1 2 Doc Rev 01 06 Aastra CNX Installation and Setup Procedures Procedures Step Action 9 Enter the domain name for the Aastra CNX and press lt Enter gt For example Domain Name aastra com The following prompts display Nameserver 1 Nameserver 2 10 Enter the IP address of the DNS servers for the Aastra CNX and press lt Enter gt For example Nameserver 1 192 167 2 11 J Nameserver 2 192 168 2 12 J The following message and prompts display Before the following information is configured please verify the information below is correct before proceeding Domain Name aastra com Nameserver 1 192 LOTE ALL Nameserver 2 192 168 2 12 Is this correct y n continued ATP CNX 020 Rel 1 2 Doc Rev 01 06 11 Aastra CNX Quick Installation and Setup Guide Procedures Step Action 11 TR
3. brackets with six 6 Phillips head screws Truss head screws not provided One to four RJ 48C T1 E1 cable s not provided NOTE T1 E1 Ports 1 and 2 are available for the 30 port unit and the 60 port unit One 9 pin male DB 9 to female DB 9 RS 232 serial cable One or two RJ 45 10 100BaseT Ethernet cable s not provided Optional One 9 pin male DB 9 to female DB 25 RS 232 serial cable for modem connections not provided Tools required for rackmount installations In addition to the parts listed above the following tools are also required when installing an Aastra CNX rackmount unit e 2 Phillips screwdriver e Torque wrench e Nuidriver set Check the shipping contents Upon opening the shipping package inventory the contents to be sure there are no missing or damaged parts as described in the Welcome section of this document Determine location of Aastra CNX desktop or rackmount a If you are installing the Aastra CNX as a desktop unit place it on a flat surface in close proximity to your PC skip Step 2 and perform Steps 3 through 8 b If you are installing the Aastra CNX as a rackmount unit proceed to Step 2 2 ATP CNX 020 Rel 1 2 Doc Rev 01 06 Aastra CNX Installation and Setup Procedures Procedures Installing the Aastra CNX in a rack 2 Install the Aastra CNX in a rack Warning Before you install the Aastra CNX unit in a rack ensure that the rack is sturdy and well secured Caution The operatin
4. e The Aastra CNX must physically be connected to your console using an RS 232 DB 9 cable e The Aastra CNX must physically be connected to your network interface via the Ethernet port s e The Aastra CNX must be turned on e You must be running a terminal emulator on your PC Terminal emulator must be set as follows Baud Rate 9600 Data 8 bit Parity None Stop 1 bit Flow Control None The Aastra CNX setup script allows you to configure the following 1 Run network and time configuration The following procedure describes how to configure the network settings Note If at any time during the initial configuration process you want to backout of the configuration press lt ESC gt to cancel 8 ATP CNX 020 Rel 1 2 Doc Rev 01 06 Aastra CNX Installation and Setup Procedures Procedures 1 Run network and time configuration Use the following procedure to initially configure the network settings on the Aastra CNX hardware Step Action 1 After first time power up of the CNX the following displays in a terminal window Welcome to the Aastra CNX Conference Bridge Configuration Utility please press lt enter gt to continue Press lt Enter gt The following displays Hostname Enter the hostname for the Aastra CNX and press lt Enter gt For example Hostname cenxl J The following displays Configuring ENET 1 IP Address Enter th
5. mounting brackets with six Phillips head screws One Aastra CNX Technical Documentation CD ROM e One CD ROM envelope with License Key label For a list of additional parts that you need to install the Aastra CNX which are not included in the shipping package see the section Aastra CNX Installation and Setup Procedures on page 1 C 5 Li Aastra CNX unit s tae Power cable Console cable CompactFlash card RC D License Key p QE 6 O q 0 0 Rack mounting brackets with Technical documentation CD ROM CD ROM envelope with Phillips head screws license key label xiv ATP CNX 020 Rel 1 2 Doc Rev 01 06 Aastra CNX Installation and Setup Procedures Procedures Introduction This section provides quick installation and setup procedures for installing and starting up the Aastra CNX Conference Network Switch This section also provides a list of additional parts that you need to install the Aastra CNX References For information about configuring and using the Aastra CNX see related documentation on the Aastra CNX Conference Network Switch Documentation CD ATP CNX 020 Rel 1 2 Doc Rev 01 06 1 Aastra CNX Quick Installation and Setup Guide Procedures Preparing for the hardware installation 1 Prepare for hardware installation What you need for a single installation One Aastra CNX unit One AC power cable One CompactFlash memory card One set of rack mounting
6. the AC power cable 5 Connect the power cable Ground the chassis a Locate the 3 hole female power receptacle on the rear of the chassis b Plug the male 3 prong connector on the power cable into the power receptacle c Insert the plug at the other end of the power cable into a grounded power source 100 to 240 VAC NOTE North America 120 V at 15 A Europe 240 V at 10 A CONSOLE RESET AC power cord Connect to a grounded 15 A power source 100 to 240 VAC North America 120 V at 15 A Europe 240 V at 10 A ATP CNX 020 Rel 1 2 Doc Rev 01 06 Aastra CNX Installation and Setup Procedures Procedures Starting up and checking the Aastra CNX 6 Startup and check the Aastra CNX Apply power to the Aastra CNX To start up the Aastra CNX insert the CompactFlash card into slot 1 of the unit and apply power from the power source Powering up a new Aastra CNX e Starts diagnostic test routines on the Aastra CNX e Checks for a flash memory card in CompactFlash slot 1 of the Aastra CNX chassis e Initializes the Aastra CNX and if successful resets all LEDs to their normal state e Starts a one time software script that allows you to setup your network settings See Step 7 Check the LEDs a Check the common LEDs on the front panel 0000000006 The Power and Status LEDs should be ON green 0000000006 indicating the Aastra CNX is ready to take calls b Check the ENET LE
7. the date and time are correct and press lt Enter gt TE Enter n if the date and time are incorrect and press lt Enter gt won Note If you entered n at the verification prompt repeat step 14 to correct the date and time and oo then enter y at step 15 The following message displays after entering y at the verification prompt Configuring Network Time Protocol NTP You can configure up to 4 NTP servers To remove an existing server set it s address to 0 0 0 0 If no valid servers are given then ntp will be disabled Do you want to continue y n n 16 TR Enter y to continue and press lt Enter gt The following prompts display NTP Server 1 pool ntp org NTP Server 2 pool ntp org NTP Server 3 pool ntp org NTP Server 4 pool ntp org 14 continued ATP CNX 020 Rel 1 2 Doc Rev 01 06 Aastra CNX Installation and Setup Procedures Procedures Step Action 17 Enter up to four NTP servers in your network and press lt Enter gt For example 192 167 2 11 J 192 167 2 12 J 0 0 0 0 J 0 0 0 0 J NTP Server 1 pool ntp org NTP Server 2 pool ntp org NTP Server 3 pool ntp org NTP Server 4 pool ntp org Notes 1 You can enter up to four NTP servers If you have fewer than four NTP servers enter the IP address es for the NTP servers that you have and then enter 0 0 0 0 for the remainin
8. Canada a approuv le mat riel NOTE L tiquette du minist re des Communications du Canada indique que l appareillage est certifi c est dire qu il respecte certaines exigences de s curit et de fonctionnement visant les r seaux de t l communications Le minist re ne garantit pas que l appareillage fonctionnera la satisfaction de l utilisateur Avant d installer l appareillage s assurer qu il peut tre branch aux installations du service de t l communications local L appareillage doit aussi tre raccord selon des m thodes accept es Les r parations de l appareillage certifi devraient tre confi es un service d sign par le fournisseur En cas de r paration ou de modification effectu es par l utilisateur ou de mauvais fonctionnement de l appareillage le service de t l communications peut demander le d branchement de l appareillage Pour leur propre s curit les utilisateurs devraient s assurer que les mises la terre des lignes de distribution d lectricit des lignes t l phoniques et de la tuyauterie m tallique interne sont raccord es ensemble Cette mesure de s curit est particuli rement importante en milieu rural ATTENTION Les utilisateurs ne doivent pas proc der ces raccordements mais doivent plut t faire appel aux pouvoirs de r glementation en cause ou un lectricien selon le cas viii ATP CNX 020 Rel 1 2 Doc Rev 01 06 Regulatory i
9. Ds on the front panel If your Aastra CNX has a physical Ethernet link to your network from the 10 100 ENET ports 1 or 2 on the back panel and no alarms are present the ENET LEDs 1 and or 2 should be ON green NOTE The ENET LEDs FLASH green when there is Rx Tx activity c The T1 E1 ports are disabled by default in the Aastra CNX software configuration The top row of T1 E1 LEDs should be OFF To enable these ports and check the LEDs the System Administrator must enable the T1 E1 ports using the Aastra CNX GUI 1234 POWER 12 OO ACTIVE STATUS O OOOO ALARM 10 100 ENET T1 E1 Alarm Indicators a Check that the Status LED is not ON Red If the Status LED is ON Red an alarm condition exists in the unit Contact your System Administrator NOTE During bootup of the Aastra CNX the Status LED is ON Red for 1 second This is a normal condition at bootup b When the T1 E1 port s are enabled check that the T1 E1 LEDs on the bottom row are OFF If the T1 E1 LED s on the bottom row are ON Amber a yellow alarm is present on the T1 E1 link If the T1 E1 LEDs are ON Red a Red alarm is present on the T1 E1 link Contact your System Administrator ATP CNX 020 Rel 1 2 Doc Rev 01 06 7 Aastra CNX Quick Installation and Setup Guide Procedures Configuring the network settings T Configure the network settings Requirements The following is required before you configure the Aastra CNX for the first time
10. Enter y if the DNS information is correct and press lt Enter gt wos Enter n if the DNS information is incorrect and press lt Enter gt won Note If you entered n at the verification prompt repeat steps 9 and 10 to correct the DNS woos information and then enter y at step 11 The following message and prompts display after entering y at the verification prompt Unpacking timezones please wait one moment Timezone Configuration Africa Chile GMT Jamaica Navajo US America Cuba GMT 0 Japan PRC UTC Antarctica EET GMT 0 Kwajalein PST8PDT Universal Arctic EST GMTO Libya Pacific W SU Asia ESTSEDT Greenwich MET Poland WET Atlantic Egypt HST MST Portugal Zulu Australia Eire Hongkong MST7MDT ROC Brazil Etc Iceland Mexico ROK CET Europe Indian Mideast Singapore CST6CDT GB Iran NZ Turkey Canada GB Eire Israel NZ CHAT UCT Enter a choice back to go up one level or cancel to cancel 12 Enter your local timezone and press lt Enter gt For example Enter a choice back to go up one level or cancel to cancel EST J Note Some of the options in the Timezone Configuration list display an additional list of options For example if you select America from the Timezone Configuration list another list of options displays for timezones in America The following message and prompt displays Timezone EST Are you sure
11. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service vi ATP CNX 020 Rel 1 2 Doc Rev 01 06 Regulatory information If you experience trouble with this equipment please contact Aastra Telecom for repair and warranty information If there is a problem with the network the telephone company may request that you remove the equipment from the network until the problem is resolved Aastra Telecom recommends that you install an AC surge protector in the AC outlet to which the equipment is connected This helps to prevent damage to the equipment caused by local lightning strikes or other electrical surges THE AASTRA CNX HAS NO USER SERVICEBLE PARTS FCC and telephone company procedures and requirements In order to connect this equipment to the network you must provide the local telephone company with the registration number of this equipment and you must order the proper connections To order the proper service provide the telephone company with the following information e Number of required jacks and their USOC numbers e Sequence in which the trunks are to be connected e Facility interface codes by position CSA certification U S and Canada This equipment has been certified by CSA for use in the U S and Canada to the requirements of UL 1950 Third Edition Safety of Information Technology Equipment Including Electrical Business e
12. OR CONSEQUENTIAL DAMAGES OF ANY KIND OR NATURE OR OTHER LOSS DAMAGE OR EXPENSE DIRECTLY OR INDIRECTLY ARISING FROM CUSTOMER S USE OF OR INABILITY TO USE PRODUCT EITHER SEPARATELY OR IN COMBINATION WITH OTHER EQUIPMENT ATP CNX 020 Rel 1 2 Doc Rev 01 06 v Aastra CNX Quick Installation and Setup Guide Regulatory information Regulatory information U S A requirements The AASTRA CNX has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commission FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense Do not attempt to repair or modify this equipment All repairs must be performed by Aastra Telecom or an authorized Aastra Telecom representative FCC Part 68 general information The AASTRA CNX complies with Part 68 of the FCC rules and the requirements adopted by the ACTA On the bottom of this equipment is a label that contains among o
13. able to an Ethernet port on the back panel of the Aastra CNX and the other end to a LAN port To connect a modem a Attach the 9 pin male connector on the serial cable to the female console port on the rear panel of the Aastra CNX b Attach a 25 pin male connector on the modem cable to the modem s DB 25 RS 232 port DB 9 port on PC PC or terminal Aastra CNX Ethernet LAN Console port DB 9 to DB 9 console cable Modem AT or Hayes compatible DB 25 RS 232 port To console port on Aastra CNX DB 9 to DB 25 modem cable 4 ATP CNX 020 Rel 1 2 Doc Rev 01 06 Aastra CNX Installation and Setup Procedures Procedures Connecting the network cables 4 Connect network cables Make sure you have the network cables that you need for your facility and connect them to the following interfaces as appropriate e T1 E1 Connect the RJ 48C T1 E1 cable s to the RJ 48C T1 E1 port s on the rear panel of the Aastra CNX e Ethernet Connect the RJ 45 Ethernet UTP cable s to the RJ 45 10 100 ENET port s on the rear panel of the Aastra CNX O O TIEI 10100 ENET O O 1 2 3 4 CONSOLE RESET 1 2 Q fe 100 240VAC O 1 0A 47 63HZ T1 E1 RJ 48C Ethernet RJ 45 connectors connectors ATP CNX 020 Rel 1 2 Doc Rev 01 06 Aastra CNX Quick Installation and Setup Guide Procedures Connecting
14. ain protection for this equipment e Ensure that rack installation does not result in airflow blockage to power supply vents or chassis vents e Before installing the Aastra CNX rackmount version ensure that the rack is sturdy and well secured Lithium battery caution CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Discard used batteries according to the manufacturer s instructions ATTENTION Il y a danger d explosion s il y a remplacement incorrect de la batterie Remplacer uniquement avec une batterie du m me type ou d un type recommand par le constructeur Mettre au rebut les batteries usag es conform ment aux instructions du fabricant Compliances The Aastra CNX is in compliance with regulations as follows Environmental 32 104 F 0 40 C Humidity 10 85 non condensing s 400 BTUs hour 28 dBA maximum acoustic noise e Safety Certifications cUL 950 NTRL UL 1950 TUV EN 60 950 e Telecom Approvals FCC Part 68 Industry Canada CTR4 EMI RF FCC Part 15 Class A EN55022 Class A CISPR EN55024 x ATP CNX 020 Rel 1 2 Doc Rev 01 06 Software licensing and copyright Software licensing and copyright The Aastra CNX product consists of an Aastra designed hardware platform distributed with embedded Linux operating system and application software This embedded software consists of multip
15. anadian STIS dirai ideal niateiner nues vii European FOQUITEIN GINS nn re demise easier nea ane ix SOIT WOMMINGS sssscccdsecsensnasesssiacagiarsvunnesaci tense sstra vei gdarreadiastisacessia mnie daira miadanradeevete x Gerora AN EEE RP nie dasu tian tadietupalemu eed x LOC PASS AO en una one ttre E EE x CORTICES TE PI Re x Sofiware licensing and copyright du serum on tant ann audi tt miv ana xi Welcome POINT EEI E E E E medi agunileuchatsieaushdaneitecbiaeasideedsduiiadastiannueees xiii What doss Me Aasia CNA GOT seisseen xiii What is in the Aastra CNX shipping package ccceeeeeeeeeeeeceeeeeeeeeeeeeeeeeesenaaees xiv Aastra CNX Installation and Setup Procedures Procedu eiro a en Rata nn ie 1 LES L RER ea eto eaamaintee 1 Preparing for the hardware installation lt 2ssuiciccevsssseddecerssnnedeeesssaswsaeevisasdsseeesasausesecrnuese 2 installing the Aastra CNX ina Tack sistema 3 Connecting to fie console POr ssssssscnssssmnessenaserenissnenmasanssrenanprets 4 Connecting the network cables saurai patrie emmaaammanaanraaaagiatanddadinied 5 Connecting the AC power cable ssisissinsss siias ia 6 Starting up and checking the Aastra CNX sissccsssessucessssnsssscspsisnsssccasriassncseessanieesessnnneaas 7 Configuring the network Settings nant anna nRa 8 Using the Aastra CNX GUI via the Wob nine nant sion 16 ATP CNX 020 Rel 1 2 Doc Rev 01 06 sJue u01 Warranty regulatory safety and copyright licensing notices Warranty A
16. astra Telecom Inc Aastra Telecom Inc Aastra warrants Warranty to its customer that i Aastra has good and marketable title to the Product at the time of delivery to its customer free and clear of any and all security interests liens claims charges or encumbrances and ii the Product shall be free from defects in design material and workmanship and shall perform in accordance with the Aastra specifications in all material respects when used for the intended purpose for a period of twelve 12 months from the date of purchase of the Product by such customer from Aastra Warranty Period This Warranty specifically excludes any representation warranty condition or other term relating to any software contained in the Product At its sole option Aastra shall either repair or replace defective Product returned during the Warranty Period Any repaired or replacement Product shall subsequently be covered for the balance of the original Warranty Period or ninety 90 days whichever is longer Upon customer s specific request Product that fails after the Warranty Period expires may be returned for repair at the then current rates with the cost of such repairs and shipping to be borne by customer Customer shall obtain a returned material authorization RMA number from Aastra and comply with shipping instructions for all defective Products being returned to Aastra Defective Products shall be returned to Aastra at the customer s sole ex
17. e IP address for the Ethernet port for which you want to use as a management interface and press lt Enter gt For example IP Address 192 168 2 6 The following displays Netmask Enter the Netmask for the Ethernet port for which you want to use as a management interface and press lt Enter gt For example Netmask 255 255 255 0 J The following displays Default Gateway continued ATP CNX 020 Rel 1 2 Doc Rev 01 06 9 Aastra CNX Quick Installation and Setup Guide Procedures Step Action TR Enter y if the network information is correct and press lt Enter gt wos Enter n if the network information is incorrect and press lt Enter gt won Note If you entered n at the verification prompt repeat steps 3 through 7 to correct the network woo information and then enter y at step 8 The following message and prompt display after entering y at the verification prompt Configuring Domain Name Service DNS Domain Name 7 Enter the Default Gateway for the Ethernet port for which you want to use as a management interface and press lt Enter gt For example Default Gateway 192 168 2 1 J The following displays Before the following information is configured please verify the information below is correct before proceeding Hostname cnx1 IP Address 192 168 2 6 Broadcast Address 192 168 2 255 Netmask 255 255 255 0
18. faction Before installing this equipment ensure that it is permissible to connect to the facilities of the local telecommunications company You must install this equipment using an acceptable connection method ATP CNX 020 Rel 1 2 Doc Rev 01 06 vii Aastra CNX Quick Installation and Setup Guide Regulatory information Repairs to certified equipment should be made by a supplier designated representative If you make repairs or alterations to this equipment or if the equipment malfunctions the telecommunications company may request that you disconnect the equipment You should ensure for your own protection that the electrical ground connections for the power utility telephone lines and internal water pipe system if present are connected This precaution may be particularly important in rural areas CAUTION You should not attempt to make such connections You should contact the appropriate inspection authority or electrician Canada CS 03 R gles et reglements AVIS Le pr sent mat riel est conforme aux sp cifications techniques d Industrie Canada applicables au mat riel terminal Cette conformit est confirm e par le num ro d enregistrement Le sigle IC plac devant le num ro d enregistrement signifie que l enregistrement s est effectu conform ment une d claration de conformit et indique que les sp cifications techniques d Industrie Canada ont t respect es Il n implique pas qu Industrie
19. g NTP entries 2 If you do not have your own NTP server and the Aastra CNX has Internet connectivity you may use the default server entry of pool ntp org 3 Aastra Telecom strongly recommends the use of NTP servers either your own or the default servers NTP servers avoid clock slippage and inconsistent conference start times on the Aastra CNX However you may completely disable the NTP server feature by setting the IP address of all four servers to 0 0 0 0 The following displays Before the following information is configured please verify the information below is correct before proceeding NTP Server 1 192 167 2 11 NTP Server 2 192 167 2 12 Is this information correct y n n 18 oo Enter y if the NTP information is correct and press lt Enter gt wos Enter n if the NTP information is incorrect and press lt Enter gt RE Note If you entered n at the verification prompt repeat step 17 to correct the NTP information and oo then enter y at step 18 ed The following message displays after entering y at the verification prompt The conference bridge has now been configured the system will now reboot to reflect the changes 19 You have successfully initialized the Aastra CNX When you have completed initializing and configuring the Aastra CNX go to Step 8 Using the Aastra CNX GUI via the Web on page 16 For more info
20. g environment must provide unobstructed front to back airflow to the chassis mounted in a rack To install an Aastra CNX in a rack a Mount the rackmount brackets to the Aastra CNX unit in a flush mount position using the 6 Phillips head screws b Align the bracket holes to the rack and insert truss head screws not provided c Tighten the screws to 15 in lb 69 Nm oe WN aN N lt a i 0O0OOCOOOOOOOO00 OGE0OCOCOCOCOO DODOOCODOCOOOOCOOCCEC ATP CNX 020 Rel 1 2 Doc Rev 01 06 3 Aastra CNX Quick Installation and Setup Guide Procedures Connecting to the console port 4 3 Connect to the console You can access the Aastra CNX console locally or remotely Ensure that you Console port parameters configure your terminal or PC terminal emulator console port parameters Parameter Value Local connection Baud rate 9600 To connect a local PC or terminal Flow control None a Attach the 9 pin male DB 9 connector on the serial cable to the Databits 8 female console port on the rear panel of the Aastra CNX Stop bits 1 b Attach the 9 pin female connector on the serial cable to the male console Parity None port on the back of your PC or terminal Remote connection To connect a remote PC and an Aastra CNX to an Ethernet LAN a Attach one end of an Ethernet cable to the Ethernet port on the PC and the other end to a LAN port b Attach one end of an Ethernet c
21. le Aastra and third party programs each individual program may be subject to one or more Copyrights or Software Licenses the overall aggregation and distribution of these separate programs is protected as a collective work Copyright Aastra Telecom Inc 2005 Use and distribution of the CNX product are deemed to be acceptance of the Software Licensing terms contained within the Aastra CNX Service Level Agreement Associated third party license agreements and applicable Open Source software licenses are incorporated by reference the full text of all licenses can be found on the Aastra CNX documentation CDROM The following is a list of Aastra CNX software licenses See the Aastra CNX documentation CD for more information about these licenses Aastra SLA 1 5 e Copying GPLv2 e Nettfilter licensing e Asterisk credits LINUX note e Apachev11 e APLv11 OpenORB EXOLAB e MPLv1 e MPLv11 e OpenH323 LINUX PAM e Sun Microsystems Popt X11 ATP CNX 020 Rel 1 2 Doc Rev 01 06 PWLIB PCMCIA CS BSD Syslogd Klogd Copying LIB LGPL 2v1 GLIBC Sendmail WU ftpd Xinetd Ntpd OpenSSL BerkleyDB LFS bootscripts Octasic Device Enabling xi Welcome Introduction Congratulations You have purchased a highly functional cost effective easy to use Aastra CNX Conference Network Switch for use in your network The Aastra CNX is easy to install and operate and provides a comprehensive set of security fea
22. nformation European requirements CE EMI EN 55 022 statement This certifies that the Aastra CNX Asterisk Network Switch is shielded against the generation of radio interference in accordance with the application of Council Directive 89 336 EEC Conformity is declared by the application of EN 55 022 1998 and EN 55 024 1998 WARNING This is a Class A product In a residential area this product may cause radio interference in which case the user may be required to take the appropriate measures EC declaration of conformity This product conforms to the provisions of Council Directive s EMC Directive 89 336 EEC Low Voltage Directive 73 23 EEC and R TTE Directive 1999 5 EC ATP CNX 020 Rel 1 2 Doc Rev 01 06 ix Aastra CNX Quick Installation and Setup Guide Safety warnings Safety warnings General warnings The following safety warnings apply e Mechanical hazards and electrical shock hazards are possible if you remove one or more of the modules There are no operator serviceable modules Only qualified personnel should service this equipment This equipment must be connected to a protective ground according to the instructions in this manual Improper grounding may result in electrical shock This equipment does not provide safety isolation between any port that is connected to a digital network termination point or any port to which terminal equipment is connected e The wall circuit breaker provides the m
23. pense Aastra shall repair or replace defective Products returned under Warranty at no charge to customer and Aastra shall bear the expense of the return shipment of the repaired or replacement Product to customer Aastra does not warrant the Product to be compatible with the equipment of any particular telephone company or their network This Warranty does not extend to Products damaged by improper installation or operation alteration accident neglect abuse misuse fire or natural causes such as storms or floods Aastra reserves the right to use refurbished parts in the repair or replacement of defective Products Unauthorized modification or repair will void the Warranty To exercise the Aastra CNX Warranty 1 First contact your reseller for instructions 2 Alternatively you can contact Aastra Telecom at 1 866 599 7399 Warranty Limitation THE FOREGOING PRODUCT WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES AS TO THE CONDITION OPERATION AND PERFORMANCE OF THE PRODUCT EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTIES AND OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AASTRA S SOLE AND EXCLUSIVE LIABILITY AND CUSTOMER S SOLE AND EXCLUSIVE REMEDY FOR ANY AASTRA BREACH OF WARANTIES HEREUNDER SHALL BE AASTRA S OBLIGATION TO REPAIR OR REPLACE THE PRODUCT AS SET FORTH IN THIS SECTION AND AASTRA SHALL NOT BE LIABLE FOR ANY DAMAGES WHATSOVER INCLUDING BUT NOT LIMITED TO DIRECT INDIRECT INCIDENTIAL
24. quipment and Canadian Standards Association CAN CSA C22 2 No 950 95 Third Edition Canadian requirements Canadian Department of Communications Radio Interference Regulations This digital apparatus Aastra CNX does not exceed the Class A limits for radio noise emissions from digital apparatus as documented in the Radio Interference Regulations of the Canadian Department of Communications R glement sur le brouillage radio lectrique du minist re des Communications Cet appareil num rique Aastra CNX respecte les limites de bruits radio lectriques visant les appareils num riques de classe A prescrites dans le R glement sur le brouillage radio lectrique du minist re des Communications du Canada Canada CS 03 rules and regulations NOTICE This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is confirmed by the registration number The abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment NOTE The Canadian Department of Communications label identifies certified equipment The certification means that the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the user s satis
25. rmation about logging in see the Aastra CNX System Administrator Guide ATP CNX 020 Rel 1 2 Doc Rev 01 06 15 Aastra CNX Quick Installation and Setup Guide Procedures Using the Aastra CNX GUI via the Web 8 Using the Aastra CNX GUI via the Web To begin using the Aastra CNX GUI via the Web interface Important The JRE allows you to use the Aastra CNX graphical user interface GUI to configure manage and maintain the Aastra CNX You must have JRE installed in order to use the Aastra CNX GUI If your PC running Windows is connected to the Internet the JRE automatically installs if not already installed when accessing the Aastra CNX GUI If you do not have access to an Internet connection OR if you are using the Aastra CNX in a Linux environment you must acquire the applicable JRE and install it manually before using the Aastra CNX GUI a Open your web browser and enter the URL or IP address of the Aastra CNX For example http cnx1 aastra com or http 192 168 112 15 b Enter the username and password provided by the System Admininstrator Note Default username and password for System Administrators is cnxadmin c Enter the Aastra CNX License Key and click APPLY The License Key can be found on the label located on the Documentation CD ROM envelope The Aastra CNX reboots Close your web browser and wait a few minutes before logging in again d Repeat steps a and b when the reboot is complete e Change
26. the default password by clicking the Change Password button Configure the Aastra CNX and or schedule conferences as required Note Available tasks are dependent on whether you are a System Administrator or Registered User faa Additional Notes 1 After port upgrades and major software releases on the Aastra CNX a System Administrator must enter a new license key to activate the software See the Aastra CNX System Administrator Guide for more details 2 The CNX performs an automatic reboot as part of an upgrade process For configuration details System Administrators only See the Aastra CNX Conference Network Switch System Adminstrator Guide provided on the Aaster CNX Conference Network Switch Documentation CD All documentation is provided in PDF format For troubleshooting If you are having problems using your Aastra CNX contact your reseller or Aastra Telecom Technical Support 16 ATP CNX 020 Rel 1 2 Doc Rev 01 06 Aastra CNX Conference Network Switch Installation and Setup Guide Printed in the USA ATP CNX 020 Aastra CNX Release 1 2 Document Revision 01 06 July 2005 AASTRA Telecom
27. ther information a product identifier in the format US 2L4DDNANAASTRAO1 If requested this number must be provided to the telephone company This Aastra CNX uses the following USOC RJ 48 jacks Interface Service Code Facility Code 1 544 Mb s superframe format SF without line power 6 0Y 04DU9 BN 1 544 Mb s superframe format SF and B8ZS without line power 6 0Y 04DU9 DN 1 544 Mb s ANSI extended superframe format ESF without line 6 0Y 04DU9 1KN power 1 544 Mb s ANSI extended superframe format ESF and B8ZS 6 0Y 04DU9 1SN without line power A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA A compliant telephone modular plug is provided with this product It is designed to be connected to a compatible modular jack that is also compliant See installation instructions for details If the AASTRA CNX causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facility equipment operations or procedures that could affect the operation of the AASTRA CNX
28. tures you would expect from a state of the art call conferencing product What does the Aastra CNX do The Aastra CNX is a conference network switch that provides High quality voice conferences for up to 30 participants in up to 15 active conferences upgradable to 60 participants and 30 active conferences or 120 participants and 60 active conferences Allows for permanent and scheduled conferences Comprehensive conference controls for host and participants using a simple touch tone telephony interface Simple to install configure manage and use through an intuitive web interface Integrates with existing office systems connects to Private branch exchange PBX using ISDN PRI and IP PBXs using SIP or H 323 Comprehensive security features Cost effective conferencing for small to medium size enterprises ATP CNX 020 Rel 1 2 Doc Rev 01 06 xiii Aastra CNX Quick Installation and Setup Guide Introduction What is in the Aastra CNX shipping package The Aastra CNX is carefully and securely packaged within the shipping container Upon opening the shipping package inventory the contents to be sure there are no missing or damaged parts The following parts are included e One Aastra CNX unit e One Power cable for connection to AC power source e One DB 9 to DB 9 console cable One CompactFlash memory card that contains the software required to operate the unit for use in CompactFlash memory slot 1 e One set of rack
29. y n continued 12 ATP CNX 020 Rel 1 2 Doc Rev 01 06 Aastra CNX Installation and Setup Procedures Procedures 14 Step Action 13 Enter y if the timezone is correct and press lt Enter gt Enter n if the timezone is incorrect and press lt Enter gt Note If you entered n at the verification prompt repeat step 12 to correct the timezone and then enter y at step 13 TA The following message and prompts display after entering y at the verification prompt Pleas nter the date and time Four digit year 2005 onth 03 Day 09 Hour 19 Minutes 40 The defaults for the date and time are the current date and time on your PC If these defaults are correct press lt Enter gt at each prompt without making an entry If a default is incorrect enter the correct value and press lt Enter gt to continue In the following example 14 is entered for the hour since the default of 19 is incorrect Four digit year 2005 Month 03 Day 09 Hour 19 14 Minutes 40 The following displays Before the following information is configured please verify the information below is correct before proceeding Date 2005 03 09 14 40 00 Is this the correct time y n n continued ATP CNX 020 Rel 1 2 Doc Rev 01 06 13 Aastra CNX Quick Installation and Setup Guide Procedures Step Action 15 TR Enter y if

Download Pdf Manuals

image

Related Search

Related Contents

Smeg ALFA41VEK Installation Manual  Traitement eau – Filtration Perfecteau inc. – tête de contrôle CLACK  Télécharger  xendos 1800 Series 1 1 INTRODUCTION 1.1 Warnings, Cautions  eXAS - Trader Admission User Manual  Guide visiteur forum Post-bac - Institut Confucius (Paris 7)  RENTRÉE 2014 MODE D`EMPLOI  Bootloader – Istruzioni per l`uso  Istruzioni per l`uso - Bockwoldt GmbH & Co. KG  