Home
3D Connexion RMR203HG User's Manual
Contents
1. 2007 8 9 5 27 38 PM LED status indicator Wall mount hole Battery compartment RESET hole CHANNEL switch G e w N S GETTING STARTED 1 Remove the battery compartment 2 Insert the batteries matching the polarities see FIG 2 RMR203HG IM EN R5 indd 3 MEANING LocATION Clock alarm Main unit batteries low Outdoor temperature Sensor batteries low and humidity area REMOTE SENSOR The main unit can collect data from up to 3 sensors To set up the sensor 1 Open the battery compartment see FIG 3 2 Select a channel then press RESET 3 Close the battery door 4 Place the sensor within 30 m 98 ft of the main unit using the table stand or wall mount TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 1 5 m 5 ft and which can shield it from direct sunlight or wet conditions for an accurate reading 2007 8 9 5 27 41 PM 1 5 m 5 ft HHHHHHHH NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing To search for a sensor Press and hold MODE simultaneously The sensor reception icon in the remote sensor area shows the status RMR203HG IM EN R5 indd 4 CLOCK DESCRIPTION Main unit is searching for sensor s A channel
2. has been found The sensor cannot be found TIP The transmission range may vary depending on many factors You may need to experiment with various locations to get the best results This product is designed to synchronize its clock automatically with a clock signal Slide EU UK to select the signal received EU DCF 77 signal within 1500 km 932 miles of Frankfurt Germany UK MSF 60 signal within 1500 km 932 miles of Anthorn England To enable disable signal reception Press and hold A to enable or W to disable signal reception NOTE Reception takes 2 10 minutes If the signal is weak it can take up to 24 hours to get a valid signal If signal 2007 8 9 5 27 44 PM L SSE RMR203HG IM EN R5 indd 5 reception is unsuccessful place your unit next to a window press and hold A to force another signal search Clock signal reception indicator WEAK SIGNAL STRONG SIGNAL NO SIGNAL To set the clock manually disable the signal reception first 1 Press and hold MODE 2 Press A or Yy to change the settings 3 Press MODE to confirm 4 The settings order is time zone 12 24 hr format hour minute year calendar mode day month month day month day and language Time zone offset sets the clock 23 hours from the received clock signal time NOTE The language options are English E German D French F Italian 1 and Spanish S To select dis
3. IT www2 oregonscientific com service support asp OR LxWxH 73 x 47 x 132 5 hes ane ee Call 1 800 853 8883 2 87 x 1 85 x 5 22 in For international inquiries please visit RMR203HG IM EN R5 indd 6 2007 8 9 5 27 47 PM ee www2 oregonscientific com about international asp EU DECLARATION OF CONFORMITY Hereby Oregon Scientific declares that this Temperature and Humidity Station with Atomic Time Model RMR203HG is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service cE COUNTRIES RTTE APPROVED COMPLIED All EU countries Switzerland CH and Norway ND RMR203HG IM EN R5 indd 7 2007 8 9 5 27 47 PM
4. L SSE ee Temperature and Humidity Station EU Declaration of Conformity cccessseeee eee 7 with Atomic Time Model RMR203HG USER MANUAL CONTENTS OVOIVIOW niieccesisscecsctseriedsntvectectestennedsctsttecteacestieteeviessezeates 2 Front View Back View Remote Sensor Getting Started c ccsccscissccccccccteccsarsceccecrsessccctzssescecszeeseees 3 Insert Batteries RemoteSensor Sensor Data Transmission Glock RECeplION iisie z csccisss ss satisarieenicnaiceccecitie amiss 4 Manually Set Clock Temperature And Humidity a a a i A N EN petee cepereerr re erste A E 5 Precautions Specifications About Oregon Scientific ccc eseseeseeeeseeseneeseneeeeeeeee 6 RMR203HG IM EN R5 indd 1 2007 8 9 5 27 36 PM Remote sensor reception indicator Clock signal reception indicator MODE Change settings display LIGHT Activate backlight for 5 seconds a Pe NS A I vV Increase decrease settings activate deactivate clock reception signal Outdoor temperature and humidity 7 Indoor temperature and humidity gt RMR203HG IM EN R5 indd 2 9 10 Clock with weekday MEM View current maximum minimum temperature humidity Ice alert LED indicator BACK VIEW FIG 2 1 2 3 C F Select temperature unit RESET Reset unit to default settings EU UK Select the nearest radio signal
5. play mode Press MODE to choose between clock with seconds weekday calendar TEMPERATURE AND HUMIDITY To toggle temperature unit Press C F To auto scan between sensors Press and hold y MEM to display each sensor s data for 3 seconds To end press A 5 To toggle between current minimum and maximum records for the selected sensor Press MEM repeatedly To clear the records Press and hold MEM If the channel 1 sensor falls between 3 C to 2 C 37 F to 28 F LED indicator will flash and will stop flashing once the temperature is out of this range BACKLIGHT Press LIGHT to activate backlight for 5 seconds RESET Press RESET to return to the default settings PRECAUTIONS Do not subject the unit to excessive force shock dust temperature or humidity e Do not cover the ventilation holes with any items such as newspapers curtains etc Do not immerse the unit in water If you spill liquid over it dry it immediately with a soft lint free cloth e Do not clean the unit with abrasive or corrosive materials EN 2007 8 9 5 27 46 PM Do not tamper with the unit s internal components This invalidates the warranty Weight 241 g 8 5 oz without battery e Only use fresh batteries Do not mix new and old Temperature range 5 C to 50 C 23 F to 122 F batteries 7 7 e Images shown in this manual may differ from the actual Resolution OTC 0AF display Signal freq
6. uency 433 MHz e When disposing of this product ensure it is collected Humidity range 25 95 separately for special treatment e Placement of this product on certain types of wood Humidity resolution 1 may result in damage to its finish for which Oregon Scientific will not be responsible Consult the furniture Power 2 x UM 3 AA 1 5 V batteries manufacturer s care instructions for information REMOTE UNIT THGN132N e The contents of this manual may not be reproduced without the permission of the manufacturer e Do not dispose old batteries as unsorted municipal 1 97 x 0 87 x 3 78 in waste Collection of such waste separately for special treatment is necessary e Please note that some units are equipped with a Transmission range 30 m 98 ft unobstructed battery safety strip Remove the strip from the battery F s z F compartment before first use 20 C to 60 C 4 F to 140 F LxWxH 50 x 22 x 96 mm Weight 62 g 2 22 ounces Temperature range Humidity range 25 95 NOTE The technical specifications for this product and the pa 2 contents of the user manual are subject to change without Power 1 x UM 3 AA 1 5 V batteries notice ABOUT OREGON SCIENTIFIC SPECIFICATIONS Visit our website www oregonscientific com to learn more about Oregon Scientific products TYPE DESCRIPTION If you re in the US and would like to contact our Customer Care department directly please visit MAIN UN
Download Pdf Manuals
Related Search
Related Contents
Dynacord MP7 User's Manual Bulletin technique 駐車場灯 Wireless Differential Pressure Transmitter US A5 nur f pdf Teil 1 Philips Wall light 34022/11/76 OWNERS MANUAL & WARRANTY Gateway Convertible Tablet PC Laptop User Manual Copyright © All rights reserved.
Failed to retrieve file