Home

Mobotix MX-CBL-MU-STR-05 USB cable

image

Contents

1. max 50 m 55 yd and one via MxBus It is likewise disallowed to connect one MX 232 I0O Box to several cameras Only use MOBOTIX USB cables USB cables are not part of the delivery and are to be ordered separately Options for Connecting to Cameras Function Option 1 USB Option 2 MxBus oo mwen ny Se O menion A can be switched to powered output 12 V ee a Connecting additional MxBus devices to MX 232 lO Box ee S ae Length of the connection to the camera 0 5 2 5 m 1 6 6 6 16 4 ft Max 50 m 55 yd USB Cables for Connection to Camera MX CBL MU STR 05 2 5 MX CBL MU EN STR 05 2 5 straight straight Eue e aLe ae IXe MOBOTIX USB cable 0 5 2 5 m 1 6 6 6 16 4 ft order separately iN O Only use MOBOTIX USB cables USB cables are not part of the delivery and are to be ordered separately Technical Specifications Option 1 USB Option 2 MxBus 2 galvanically separated inputs AC DC self powered up to 50 V Isolated relay output AC DC up to 50 V 60 W 2 A With jumper Powered output 12 V max cable length 50 m 55 yd see Changing the Mode of Output Outl Powered output 12 V max cable length 50 m 55 yd 400 mW 500 mW Rx Tx RTS CTS GND max 115 kbaud Minimum 0 14 mm2 AWG 26 Maximum 0 5 mm2 AWG 20 IP65 DIN EN 60529 30 to 60 C 22 to 140 F DIN EN 50125 Typically 1 W INI IN2 IN2 Output Out ounmA Operating mode can switched to powered output using th
2. to 7 mm into the casing in such a way that the rims stick out equally on both sides The max baud rate of the RS232 cable depends on the cable length and on the cross sectional area of the wires The length of the entire MxBus wiring must not exceed 50 m 55 yd Cross sectional area of the MxBus wires 0 6 to 0 8 mm 0 8 mm recommended to reduce line losses Drilling Template for New M24 Wall Mount with MX 232 lO Box 80 mm 3 15 in S f oP S E O O M24 Wall Mount HiRes Video Innovations The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its decentralized concept has made high resolution video systems cost efficient MOBOTIX AG D 67722 Langmeil Tel 49 6302 9816 0 Fax 49 6302 9816 190 sales mobotix com C FC 2012 Declaration of Conformity www mobotix com gt Support gt Media Library gt Certificates MxBus plug of MOBOTIX D14 Copyright MOBOTIX AG 2012 Made in Germany Technical information subject to change without notice
3. MX OPT RSI EXT O 2 O Q O z s S MX 232 10 Box Quick Install MA The HiRes Video Company MOBOTIX o o MX 232 10 Box Weatherproof Signal Input Output and RS232 son cl rotection C ro 60 CI 22 t0 1407 e 2 self powered inputs for connecting sensors Connection of external sensors and switching of e 2 outputs 1 powered output 1 isolated relay output can external devices via MOBOTIX cameras RS232 be switched to second powered output interface connection to camera using USB or e RS232 interface when using USB cable to connect to camera MxBus Connection of Peripheral Devices Examples MOBOTIX MX 232 l0 Box MX OPT RSI EXT RS232 connection only when connecting to camera via USB cable of oT n t iny mill Weather Station Pan Tilt head Max 10 m 11 yd Relay e g Eltako ER12 002 UC Door sensors Options for Connecting to Camera USB or MxBus MOBOTIX MX 232 I0 Box MOBOTIX D14Di DualDome MX OPT RS1 EXT MX D14Di Sec D22D22 Caution Option 1 MOBOTIX USB cable to the One MX 232 l0 Box must not camera 0 5 2 5 m 1 6 6 6 16 4 ft If you would like to use twice be connected to one camera the number of signal inputs via USB and MxBus at the and outputs you can attach same time two MX 232 10 Box modules Option 2 2 wire MxBus wiring to to one camera one via USB camera
4. ar intervals 1x RS232 communication 2 2 2 2800 Displays status of inputs outputs and RS232 alternately pauses if there is no RS232 communication Installation Instructions 1 Attach the box Attach the MX 232 l0 Box at the mounting position with the cable ports pointing downwards torque 0 4 Nm Next remove the box cover three screws 2 Establish connection to the camera You need to follow different procedures depending on the connection option e Option 1 USB Remove the slim sealing ring of the straight plug of the USB cable Pull the delivered blue sealing ring over the plug so that the smaller opening points into the same direction as the plug s contacts Remove blue bayonet catch of the MX 232 lO Box and pull out the blue plug Plug the USB cable with attached sealing ring into the MX 232 IO Box and secure the cable using the blue bayonet catch Connect the USB cable to the camera gt Camera Manual e Option 2 MxBus Before proceeding make sure there is no voltage on the MxBus wires Cutthe MxBus wires to size 2 wire 0 6 to 0 8 mm diameter When using wires without jacket strip the insulation of the wires for 5 mm and push the wires through the eight wire plug right When using a cable with jacket remove the pre installed eight wire plug and insert the appropriate cable plug 3 to 5 mm or 5 to 7 mm Press the rubber plug into the casing in su
5. camera configuration to the local computer Admin Menu gt Configuration gt Save Resetting the MX 232 IO Box If the MX 232 lO Box had been connected to a different camera before and not deactivated or reset before detaching the left LED MxBus status may blink red after establishing the MxBus connection In this case you need to reset the connected and activated MX 232 lO Box to factory defaults e Remove the box cover three screws e Bridge the contact surfaces below the Factory Reset label red circle in figure 32 using a screw driver for example both LEDs are flashing red blue with increasing fA a MOBOTIX frequency e Only remove the bridge if both LEDs of the MX 232 lO Box are flashing green on off 3 times to indicate that the process has finished successfully e Mount the cover back onto the box torque 0 4 Nm e Set up the MX 232 lO Box in the camera see nifializing the MX 232 IlO Box Notes e The MOBOTIX MX 232 IO Box is to be used only for providing signal inputs outputs and an RS232 interface only when connecting to a camera using USB for MOBOTIX cameras in IP65 environments e For MOBOTIX cameras with MxBus connector and software version MX V4 1 4 11 or higher e Make sure that you adhere to all relevant laws regulations and that you fulfill all certification requirements for the intended use Torque for all screws 0 4 Nm Press the white cable plug eight wire plug or cable plug 3 to 5 mm or 5
6. ch a way that the rims stick out equally on both sides Push the cable through the plug remove the jacket on a length of 15 mm and strip the insulation of the wires for about 5 mm Connect the MxBus wires to the terminals of the MX 232 lO Box using the screwdriver Make sure to maintain the polarity see sticker in front of the terminal Connect the MxBus wires as described in the corresponding manual to the MOBOTIX camera or to another MxBus module connected to a camera e g KeypadRFID DoorMaster Make sure not to exceed the overall length of the MxBus wiring of 50 m 55 yd 3 Connect the peripheral devices Connect the other wires cables as required and by using the corresponding cable plugs inputs outputs RS232 MxBus 4 Lock the cable in place Li lt Insert one or two cable ties depending on the attached cables as shown irae ey ay Stee ci viii a i Pull the cable ties tightly around the cables in order to provide strain relief z ttt 5 Mount the cover Mount the cover back onto the MX 232 IO Box and affix it using the cover screws torque 0 4 Nm Initializing the MX 232 IO Box 1 Open the MOBOTIX camera s user interface in the browser e Enterthe P address of the camera that is connected to the MX 232 lO Box in the browser admin access rights required http lt camera IP address gt 2 Make sure that the camera uses PoE class 3 e Open the Admin Menu gt Ethernet Interface dialog
7. e f Power Supply has not been set to Power over Ethernet Class 3 click on the Change link follow the steps of the wizard and activate Power over Ethernet Class 3 3 Activate MX 232 IO Box e Open the Admin Menu gt Manage Hardware Expansions dialog e Option 1 USB In the line MX 232 IO Box USB click on Connect e Option 2 MxBus If the LED icon in the line MxBus Interface is not green click on Connect In the Admin Menu gt Manage MxBus Modules dialog Devices section MX 232 lO Box line click on the Activate button If the Update SW button appears in this line click on it to update the software of the module 4 Configure events when using the signal inputs outputs e Open the Setup Menu gt Event Overview dialog e In the Signal Events section click on Edit and set the parameters as required open the help page for this dialog by clicking on e You can now use the new events in the Setup Menu gt Action Group Overview dialog see the help page for this dialog by clicking on D 5 Configure RS232 interface only when using Option 2 USB e Open Admin Menu gt Serial Interface gt Setup and configure the parameters in the Serial Interface and Modem as required see the help page for this dialog by clicking on 6 Store the camera configuration e Inthe Live screen of the camera click on Admin Menu gt Configuration gt Store permanently store the camera configuration and reboot the camera e Save the
8. e supplied oun jumper Changing the Mode of Output Out In order to use output Out as powered output you need to stick the jumper on the jumper pins at the right as shown in the figure The other jumper will be used in the future and must not be used at present When connecting use the terminals Out1 A and Out2 Please note that the total output rating of the MX 232 lO Box is split between the two powered outputs in this mode see Technical Specifications In this mode the max cable length for Out is also 50 m 55 yd HiRes Video Innovations The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its decentralized concept has made high resolution video systems cost efficient MOBOTIX AG D 67722 Langmeil Tel 49 6302 9816 0 Fax 49 6302 9816 190 sales mobotix com 31 321_EN_V1_08 2012 Z T Drilling templates for other MOBOTIX wall mounts www mobotix com gt Support gt Manuals O 2 O Q O z s S MX 232 1I0O Box Quick Install A The HiRes Video Company MOBOTIX LED Signaling Operation I O Status t00 Connection to Camera Not connected Regular operation Unencrypted communication MX 23240 Box et Communication error 1x Input 1 closed O ES 2x Input 2 closed I O Status 1x Output 1 closed amp LED permanently on right 2x Output 2 closed LED flashes at regul

Download Pdf Manuals

image

Related Search

Related Contents

Bissell 6801 User's Manual  Cisco Systems ASA 5500 Security Camera User Manual  Marshall Amplification JVM205C User's Manual  Télécharger - Jeunesse & Santé  Sony DCR-DVD850 Operating Guide  R0E5571MLDMB01 User`s Manual Debugging MCU Board for 144  Mini LED Projector "The Atom"  MANUAL DO USUÁRIO  OpenVox GSM Gateway Function User Manual  Tide Tool 9.2 Manual V2.0 - University of Hawaii Sea Level Center  

Copyright © All rights reserved.
Failed to retrieve file