Home
        Tripp Lite SmartOnline 100-120V 1.5kVA 1.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
         Contents
1.   4 16    Tripp Lite   1111 W  35th Street  Chicago  IL 60609 USA  Telephone  773 869 1234    www tripplite com    UPS Shipping Dimensions  hwd   38 7 x 33 x 61  cm       UPS Shipping Dimensions  hwd   in     15 2 x 13 x 24    ENVIRONMENTAL    0 to 95   non condensing    AC Economy Mode BTU   Hr   Full 260 4  Load  i    Battery Mode BTU   Hr   Full Load  609 7    AC Mode Efficiency Rating  100  o   87   Load     AC Economy Mode Efficiency Rating 94    100  Load     Audible Noise  lt  45 dB at front side 1m    COMMUNICATIONS    Communications Interface USB  HID enabled   DB9 Serial  Contact closure  EPO  emergency power off   Slot for SNMP Web interface    Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions  DB9 port supports RS232 and contact closure  communications    PowerAlert Software Included  Communications Cable USB and DB9 cabling included  WatchDog Compatibility Supports Watchdog application  OS and hard reboot restart options for remote applications    LINE   BATTERY TRANSFER    Transfer Time No transfer time  0 ms   in online  double conversion mode    Low Voltage Transfer to Battery 80V  100  load   65V    lt 70  load   Power  Setpoint     High Voltage Transfer to Battery 150  Power  Setpoint   SPECIAL FEATURES    Cold Start  Startup in Battery Mode  During a Power Failure        Cold start operation supported    5 6    Tripp Lite   1111 W  35th Street  Chicago  IL 60609 USA  Telephone  773 869 1234    www tripplite co
2.   online mode  economy bypass mode  on battery  overload  battery low  replace battery  and fault status information   includes 4 LED meter display for load and battery charge level  SURGE   NOISE SUPPRESSION    UPS AC Suppression Joule Rating    UPS AC Suppression Response  Time    UPS Dataline Suppression    EMI   RFI AC Noise Suppression    Instantaneous    1 line TEL DSL  1 in   1 out   10 100Base T Ethernet    PHYSICAL    OVERLOAD CAPACITY  Supports inverter operation up to 105  load continuously  125  load for 3 minutes  150   load for 30 seconds and  gt 150  load for 0 5 seconds before switching to BYPASS  when bypass input voltage and  frequency are WITHIN bypass limits  or SHUTDOWN  when bypass input voltage or frequency are OUTSIDE  bypass limits     Installation Form Factors Supported  with Included Accessories    Installation Form Factors Supported  with Optional Accessories  Primary Form Factor    UPS Power Module Dimensions   hwd  in      UPS Power Module Dimensions   hwd  cm     UPS Power Module Weight  Ibs    UPS Power Module Weight  kg     Stepdown Transformer Dimensions   hwd   in      Stepdown Transformer Dimensions   hwd   cm     Included Battery Pack Dimensions   hwd   in      Included Battery Pack Dimensions   hwd   cm     OVERLOAD CAPACITY  Supports inverter operation up to 105  load continuously  125  load for 3 minutes  150   load for 30 seconds and  gt 150  load for 0 5 seconds before switching to BYPASS  when bypass input voltage and  frequency are 
3. PS supported outlets  2  load banks  each with 3 outlets  can be independently controlled via a software interface to selectively reboot remote equipment or automatically shed less  critical loads to extend battery runtime for the most critical equipment  Battery backup time can be extended with the addition of multiple external battery packs   Includes slot for internal SNMP web card  plus DB9 enhanced serial monitoring port for unattended shutdown  remote control and monitoring of UPS system  and power data  HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X   Includes Tripp Lite s PowerAlert UPS Power Management Software  Compatible with Tripp Lite s Watchdog Service Monitoring Rebooting Software  Attractive  all black upright tower format   250 000 Ultimate Lifetime Insurance  U S   Canada  and Puerto Rico only     Features   e True on line  double conversion UPS provides constant  pure sine wave AC output   e Zero transfer time  on line  double conversion and economy mode operation supported   e Maintains continuous operation through blackouts  brownouts  voltage fluctuations and surges with zero transfer time   e Removes harmonic distortion  electrical impulses  frequency variations and other hard to solve power problems   e Accepts input voltages between 80V and 150V  65V to 150V at loads under 70    regulating output to 120V AC    2    e 1500VA 1200W output capacity with 6 NEMA 5 15R outlet
4. Tripp Lite    1111 W  35th Street     Chicago  IL 60609 USA  Telephone  773 869 1234    www tripplite com       SmartOnline 100 120V 1 5kVA 1 2kW On Line Highlights    Double Conversion UPS  Extended Run  SNMP  oe ae Sea  Webcard  Tower  USB  DB9 Serial ee  MODEL NUMBER  SU1500XL e 110 120V    2  output at    50 60HZz  high efficiency  economy mode option   e Expandable runtime   Hot swappable battery modules   e USB  RS232  amp  EPO ports   support for SNMP WEB card  options   e Front panel status LEDs with  detailed load and battery metering   e 2 independently switchable  output load banks   e NEMA 5 15P input  5 15R outlets       Package Includes   e SU1500XL UPS System   e PowerAlert Software   e USB  DB9 and EPO cabling    e Owner s manual with warranty    Description    Tripp Lite s SmartOnline SU1500XL on line  double conversion UPS protects critical server  networking or  telecommunications equipment from blackouts  brownouts  voltage fluctuations and surges  Large capacity  1 5kVA 1200W UPS continuously converts incoming AC to DC  then back to perfect sine wave AC output at A RON  120V AC     2    Removes harmonic distortion  fast electrical impulses  frequency fluctuations and other   hard to solve power problems not addressed by other UPS systems  True sine wave output and zero transfer time provides guaranteed compatibility with all  equipment types  Highly efficient operation in optional economy mode setting  saving BTU heat output and energy costs  Includes 6 U
5. WITHIN bypass limits  or SHUTDOWN  when bypass input voltage or frequency are OUTSIDE  bypass limits     10 2x9x 19 5  26 x 22 9 x 49 5    OVERLOAD CAPACITY  Supports inverter operation up to 105  load continuously  125  load for 3 minutes  150   load for 30 seconds and  gt 150  load for 0 5 seconds before switching to BYPASS  when bypass input voltage and  frequency are WITHIN bypass limits  or SHUTDOWN  when bypass input voltage or frequency are OUTSIDE  bypass limits     OVERLOAD CAPACITY  Supports inverter operation up to 105  load continuously  125  load for 3 minutes  150   load for 30 seconds and  gt 150  load for 0 5 seconds before switching to BYPASS  when bypass input voltage and  frequency are WITHIN bypass limits  or SHUTDOWN  when bypass input voltage or frequency are OUTSIDE  bypass limits     OVERLOAD CAPACITY  Supports inverter operation up to 105  load continuously  125  load for 3 minutes  150   load for 30 seconds and  gt 150  load for 0 5 seconds before switching to BYPASS  when bypass input voltage and  frequency are WITHIN bypass limits  or SHUTDOWN  when bypass input voltage or frequency are OUTSIDE  bypass limits        OVERLOAD CAPACITY  Supports inverter operation up to 105  load continuously  125  load for 3 minutes  150   load for 30 seconds and  gt 150  load for 0 5 seconds before switching to BYPASS  when bypass input voltage and  frequency are WITHIN bypass limits  or SHUTDOWN  when bypass input voltage or frequency are OUTSIDE  bypass limits   
6. erant electronic bypass maintains utility output during a variety of UPS fault conditions    e Diagnostic LEDs    e Built in RJ 11 EPO  Emergency Power Off  jack allows connection to site emergency power off systems    e  250 000 Ultimate Lifetime Insurance  U S   Canada  and Puerto Rico only  for connected equipment  USA and Canada Only     Specifications    OUTPUT    Output Capacity Details    Output Volt Amp Capacity  VA   Output kVA Capacity  kVA   Output Watt Capacity  Watts   Output kW Capacity  kW   Power Factor   Crest Factor    Nominal Output Voltage s   Supported    Nominal Voltage Details  Frequency Compatibility  Frequency Compatibility Details    Output Voltage Regulation  Line  Mode     Output Voltage Regulation   Economy Line Mode     Output Voltage Regulation  Battery    Mode     Output Receptacles    OVERLOAD CAPACITY  Supports inverter operation up to 105  load continuously  125  load for 3 minutes  150   load for 30 seconds and  gt 150  load for 0 5 seconds before switching to BYPASS  when bypass input voltage and  frequency are WITHIN bypass limits  or SHUTDOWN  when bypass input voltage or frequency are OUTSIDE  bypass limits     1500  1200    100V  110V  120V    120V default  50   60 Hz  Output frequency matches input nominal on startup  defaults to 60 Hz on cold start        10         2         6  5 15R    2 6    Tripp Lite    1111 W  35th Street  6 Chicago  IL 60609 USA  Telephone  773 869 1234    www tripplite com    OVERLOAD CAPACITY  Supports inver
7. m    High Availability UPS Features Automatic inverter bypass  Hot swappable batteries    High efficiency economy mode operation  Individually controllable load banks  Schedulable daily hours of economy    Green Energy Saving Features mode operation    CERTIFICATIONS    UPS Certifications Tested to UL1778  USA   Tested to CSA  Canada   Tested to NOM  Mexico   Meets FCC Part 15 Category A  EMI     WARRANTY  Product Warranty Period  Worldwide    2 year limited warranty    Connected Equipment Insurance     U S   Canada  amp  Puerto Rico   250 000 Ultimate Lifetime Insurance          2015 Tripp Lite  All rights reserved  All trademarks are the sole property of their respective owners  Tripp Lite has a policy of continuous improvement   Specifications are subject to change without notice  Photos may differ slightly from final products     6 6    
8. s   e Two built in  individually switchable load banks  each with 3 outlets  can be controlled via software interface to selectively reboot remote equipment or  automatically shed less critical loads to extend battery runtime for the most critical equipment   e Standard internal battery set provides 14 min  runtime at half load and 4 5 min  at full load   e Runtime is expandable with BP48V24 2U  limit 1   BP48V60RT 3U  multi pack compatible  and BP48V27 2US  multi pack compatible  external battery    1 6    TRIPP LITE    Tripp Lite   1111 W  35th Street  Chicago  IL 60609 USA  Telephone  773 869 1234  www tripplite com       packs    e Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software  see manual     e Attractive all black upright tower format    e Simultaneous communications via HID compliant USB port  DB9 serial port  and SNMP web card slot    e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X    e DB9 serial network interface supports RS 232 and contact closure messaging  e Slot for optional SNMP web card  part  SNMPWEBCARD   e Included PowerAlert UPS Power Management Software and cabling provides monitoring of in depth site power conditions  full UPS status and fault    warnings  output load level and load bank power control  e Compatible with Tripp Lite s WatchDog Service Monitoring Rebooting Software  part   WATCHDOGSW   e Fault tol
9. ter operation up to 105  load continuously  125  load for 3 minutes  150   UPS Output Receptacles  Surge load for 30 seconds and  gt 150  load for 0 5 seconds before switching to BYPASS  when bypass input voltage and  Suppression Only  frequency are WITHIN bypass limits  or SHUTDOWN  when bypass input voltage or frequency are OUTSIDE  bypass limits     Load Management Receptacles Two switchable three outlet 5 15R load banks    INPUT    12A  120V   14A  110V   15 44  100V     Recommended Electrical Service 15A 120V  Input Phase Single Phase    BATTERY    Full Load Runtime  min   4 5 min   1200w   Half Load Runtime  min   14 min   600w   Expandable Battery Runtime Extended runtime supported via optional external battery packs    External Battery Pack Compatibility   BP48V24 2U  limit 1   BP48V60RT 3U  multi pack compatible   BP48V27 2US  multi pack compatible     Battery Recharge Rate  Included Less than 6 hours from 10  to 90   typical  full load discharge   Batteries    Internal UPS Replacement Battery RBC48 SUTWR   Cartridge    Battery Access Battery access door  Battery Replacement Description Hot swappable  user replaceable batteries    VOLTAGE REGULATION    USER INTERFACE  ALERTS  amp  CONTROLS       3 6    Tripp Lite   1111 W  35th Street  Chicago  IL 60609 USA  Telephone  773 869 1234    www tripplite com    Audible alarm indicates UPS startup  power failure  low battery  overload  UPS fault and remote shutdown conditions  a    LED Indicators 14 LEDs indicate line power
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Cidricole et jus de fruits  LEVEL - LIFT RO OF 32 EVO  Manual electrónico    manuale di sicurezza  Elektronische Verschließzange und Entbördelwerkzeuge  Consignes de Sécurité  Notice d`installation LogoCondens 50  Samsung MG28H5125NW Manuel de l'utilisateur  製品安全データシート - 大日本スクリーン製造    Copyright © All rights reserved. 