Home

Eaton EX EXB 1000/1500

image

Contents

1. z Powering Business Worldwide Contents Uninterruptible Power Supplies Corporate OvervlIew 3 Sustainabi uuu u u ua a aa aa aayqa 4 Selecting the Right UPS 7 Pulsar Single Phase UPS 8 Source Transfer Switch 24 Power Distribution 26 Software amp Connectivity 28 UPS Quick Selection Guide 31 a IE Business Worldwide e Electrical systems and components for power quality distribution and control e Hydraulics components systems and services for industrial and mobile equipment e Hydraulics fuel and pneumatic systems for commercial and military aircraft e Intelligent truck drivetrain systems for safety and fuel economy e Automotive engine air management systems powertrain solutions and specialty controls for performance fuel economy and safety Sustainable by Design Sustainability has always been at the heart of Eaton s business this means meeting the current needs of our society while enabling future generations to meet their own needs Sustainable design for our products means helping our customers
2. Fax 91 44 2432 0249 Bangalore 8th Floor Unity Building J C Road Bangalore 560 002 India Tel 91 80 4901 2220 Fax 91 80 2227 1694 Ahmedabad 91 932 703 1597 Chandigarh 91 172501 1578 Coimbatore 91 934 541 9758 Gurgaon 91 124 436 6315 Hyderabad 91 40 4018 9606 Kolkata 91 33 3293 1395 Pune 91 20 3061 1886 Sales and Service Operations Sri Lanka 94 112871000 94 117520000 Nepal 97 714429777 97 714429888 97 714423376 Bangladesh 88002 7170368 7162568 8802 8835363 64
3. USB and DB9 serial port EXB module Operating condition standard and approval detection RJ 45 paralleling DB 15 Performance safety EMC surge protection IEC EN 62 040 3 IEC EN 62 040 1 1 IEC EN 62 040 2 class A class B as option 4 kV IEC 61 643 UL 1778 and CSA 22 2 Operating temperature noise approval Dimension HxWxD in mm Weight kg 0 C to 40 C continuous 45 dbA 10 UL T V GS mark CB C Tick CE IEC 61 931 MX RT standard backup tower 444 5x130 6x735 57 kg Tower 690 795 mm casters x444 5x735 250 kg Rack 16U x 444 5 compatible with 800 1000 mm deep rack MX RT standard backup rack 3Ux444 5 compatible with 800 1000 mm deep rack Tower 690 795 mm casters x444 5x735 250 kg Rack 16U x 444 5 compatible with 800 1000 mm deep rack MX EXB battery unit tower rack 444 5x130 6x650 3U x 444 5 70 kg dimension same as M X Frame 194 kg for 15 kVA 239 kg for 20 kVA MX ModularEasy paralleling kit dimension same as EXB battery unit 10kg Part number Convertible Tower Rack 68504 68513 68514 EXB 68515 E O N 2 MXs can be paralleled using M odularEasy At 70 load 4 IEC C13 10A 2 m long cables for use with retention clips 8 cables for use with MX Frame Frequency conversion for non paralleled units only Economy mode 91 in normal mode At 70 nominal rating with power factor 0 7 typical values after 3 charge discha
4. diagnostics and event log Outputs IEC 10A and 16A outlet sockets and hardwired outputs Built in Powershare system for remote reboot of the equipment connected sequential start up or load shedding while operating from battery to maintain the power to critical loads MX Frame is compatible with three phase or single phase Supplies Backup time 10 mins up to 2 hours by adding 3U battery extension modules 20 Minimum total cost of ownership TCO e More power with an output power factor of 0 9 e When the power supply needs to be upgraded the M X 5000 can be paralleled to provide 8 kVA or 10 kVA using the M odularEasy kit without extra cost on the initial purchase e MX Frame is a modular system with 5 kVA sub modules paralleled to provide up to 20 kVA or 15 kVA with redundancy Communications e Solution Pac 2 suite supplied for remote supervision Intelligent Power M anager for supervision via Ethernet IPM Is Compatible with standard network management systems Tivoli CA unicenter HP Openview e Compatible with Network Shutdown Module for monitoring a number of UPS and shutting down the servers on the network TECHNICAL SPECIFICATION Rating kVA kw 5 kVA 5 kVA 4 5 kW 20 kVA 20 kVA 18 kW 15 kVA 15 kVA 13 5 kW Technology Paralleling VFI SS 113 online double conversion with power factor correction convection cooled static bypass switch Maximum rating redundancy Input 10 kVA
5. pe Y MEMOL JOMOL JOMOL odl Ayiqede gt Aueneg papue x3 uoneu_nDiJuooO 1J ul qeO J N0S alaton ale UOIUO SIG DJIUOWWeH SION u SuoneueA Aduenbei SJju lsue1u HUIUDIIMS DP8l1JJOAIAO abeYOoMapuNn SHINS JOMOd bes JOMOd le JOMOd BHeOMISAOC obeyo Uspun ey alow JAOd Obes JOMOd LERENO SHINS J MOd Des J MOd LERES 1suiebv uon3 1oid o w s s XV W sd 3 Ysy sd 4 VA00SL 009 pinD uo INO Sd N UOISJ AUO7 lqnoq aul7 UO APAA SUIS QAIDCIIU SUIT DAIICJO IU SUIT u 1 JiO Aqpue1s DBo jouup l For more product Information please contact ToN E To Powering Business Worldwide Headquarters Eaton s Electrical Sector USA 8609 Six Forks Road Raleigh NC 27615 U S A South Asia Office Eaton s Electrical Sector South Asia Eaton Power Quality Pvt Ltd Unit No 1 Second Floor TDI Centre Jasola New Delhi 110 044 India Tel 91 11 4223 2300 Sales Hotline 91 11 4223 2329 Service Hotline 91 20 3061 1111 6633 0111 E mail EatonPowerQualitylndia eaton com www powerquality eaton com 2011 Eaton Corporation e All Rights Reserved e India Offices Across India Mumbai EL Floor VITS Luxury Business Hotel Andheri Kurla Road Andheri E Mumbai 400059 Tel 91 22 40053817 Fax 91 22 40053810 Chennai No 22 Chamier s Road Block D Ashika Chambers Teynampet Chennai 600 018 India Tel 91 44 2432 0249 50
6. 1 USB port 1 RS232 serial port and relay contact USB and RS232 port cannot be used simultaneously 1 mini ter minal block for remote ON OFF and Remote Power Off Communications card slot Operating condition standard and approval 1 slot for NMC Minislot card included in Netpack versions or NM C ModBus Bus or MC Contact Serial Operating temperature 0 to 40 C 0 to 40 C 0 to 40 C Noise level lt 45 dBA lt 50 dBA lt 50 dBA Performance Safety EMC IEC EN 62040 1 1 Safety IEC EN 62040 2 EN 50091 2 class B EMC IEC EN 62040 3 Performance IEC EN 61000 4 2 61000 4 3 61000 4 4 61000 4 5 61000 4 6 61000 4 8 EMI Approval CE CB report TUV CE CB report TUV CE CB report TUV Dimension HxWxD in mm Weight kg Dimension 86 2x440x509 2U 86 2x440x634 RT2U 86 2x440x634 RT2U 130 7x440 x484 RT3U 130 7x440 x484 RT3U Weight of the Tower Rack 24 3 33 8 33 8 RT2U 34 3 RT3U Dimension of EXB See UPS See UPS See UPS Weight of the EXB 30 4 417 417 Part Number Convertible Tower Rack 68456 68461 68462 EXB Model 68470 68471 68471 Runtimes are shown at 0 7 power factor Backup times are approximate and may vary with equipment configuration battery age temperature etc 17 Series 9 protection for all critical applications Technology Level 9 Double Conversion Online Rating 1000 3000 VA Configuration Tower Rack Convertible Maximum
7. 86x440x640 88x440x640 131x440x490 131x440x490 Tower EXB 440x242x153 21 kg 440x242x153 21 kg 490x131x440 3U 42 kg 490x131x440 3U 42 kg Rack EXB 483x86 5x438 2U 24 5 kg 483x86 5x438 2U 24 5 kg 490x131x440 3U 42 kg 490x131x440 3U 42 kg Part Number Tower 68181 68183 68401 68403 Rack 68182 68184 68401 68403 EXB 68185 68185 68405 68405 1 Maximum rating with EXB battery units EX 1000 800 W EX 1500 1200 W EX 3000 2400 W 2 Lower limits for lt 20 lt 33 lt 66 gt 66 of nominal power VA For active output power greater than 0 7 and 0 8 nominal rating the lower limit is 180V and 190V respectively 3 Derated by 15 when used as a frequency converter 4 USB and RS232 serial ports cannot be used simultaneously 19 Superior de centralised power protection for medium to high Technology Level 9 Double Conversion Online Rating 5 20 KVA Configuration Tower Rack Convertible Continuous power supply e Two front access hot swappable sub modules power and battery for maintenance without load interruption e Automatic battery test e Internal bypass built in to supply the load even if the UPS fails e Large input voltage and frequency ranges to avoid using the batteries unnecessarily Flexible e Can be used as a free standing tower unit or 19 rack mounted only 3U for MX 5000 and 15000 16U for MX Frame LCD multilingual display with mimic and LEDs for rapid view of the UPS status
8. Single phase UPS products delivering even greater value to its customers In fact the majority of Fortune 500 companies rely on Eaton for their power protection distribution and management solutions MGE Office Protection Systems products are a part of the Pulsar series of solutions offered by Eaton The products are designed and manufactured to offer secured power products and solutions for enterprises small business and homes with a range of uninterruptible power systems and surge suppressors With all our products Eaton strives for continued success in leveraging technical innovation to develop next generation solutions Our power quality portfolio was designed to fulfill Specific customer requirements complement a new or pre existing solution and to deliver a comprehensive solution Single Phase Products And Solutions Eaton s power management solutions are based on protecting the nine most common power problems present in any environment This unique approach makes your product selection decisions about power protection much simpler The nine power problems listed below are potentially harmful to both your data and your hardware The Level 3 UPS primarily protects against three of the nine power problems including power failures power sags and power Surges This essential cost effective protection is necessary in order to prevent damage such as data loss file corruption flickering lights hardware damage and equipme
9. availability e Configuration Double conversion on line UPS with automatic by pass and power factor correction e Powershare The EX output sockets are controlled to provide load shedding to maximise the backup time and provide remote reboot and sequential start up as standard e Continuous power supply Hot swappable batteries The HotSwap MBP Maintenance By Pass module allows the UPS to be replaced without interrupting the power supply e Long backup times 1 to 4 EXB battery units can be added Minimum total cost of ownership e Easy operation Multilingual display Access to a wide range of measurements and set up menus e Remote supervision A wide range of options using the Solution Pac supplied SNMP and HTML ModBus Bus and relay outputs 18 Flexibility EX is available in tower format or RT2U convertible rack tower version for shallow rack mounting Connections With FlexPDU and HotSwap MBP the RT2U models can be connected by sockets or terminal blocks Compatible with low power factor loads EX is rated for 0 9 total power factor Interfaces USB serial remote start stop slot for optional communications card ConnectUPS Web SNMP Card For connecting the UPS to an Ethemet 10 100 network raising SNMP alarms and supervising the UPS using a simple browser interface Environmental Monitoring Probe Monitoring the temperature humidity and 2 relay contacts via SNMP or HTML Intelligent Power M anager For comprehen
10. if the ON OFF button is set to OFF Battery monitoring Battery replacement indicator red LED Battery replacement indicator red LED Replaceable battery Access via the front panel Access via the front panel Startup without mains power cold start Can be used as a mobile power source Can be used as a mobile power source User interface Interface 1 illuminated ON OFF button 1 Fault and Overload LED 1 battery Fault LED audible alarms Power management port USB on Nova AVR USB USB on Nova AVR USB Power management Software supplied with the UPS amp free download from www powerquality eaton com Typical runtime for 1 PC min 20 30 Typical runtime for 2 PC min 8 15 Typical runtime for 3 PC min 8 Technical standard Safety and EM C Dimension and weight EN 50 091 IEC 62 040 CE logo EN 50 091 IEC 62 040 CE logo Dimension HxWxD in mm 143x125x350 188x170x376 Weight ko 5 9 12 8 Part number With USB 66823SG 66824SG 2 IEC cables supplied The highest level of protection for business computers Ellipse ASR Technology Level 3 Standby Rating 600 1500VA Configuration Tower Rack e Ellipse ASR UPSs not only provide a battery backed up supply Monitoring and system shutdown to keep equipment operating when there is a power cut but e UPS control panel also provide effective protection against damaging surges Log Ellip
11. power distribution within the rack Industrial e Compatible with all types of generator set e Can be integrated into building management systems e Steel casing e Operating temperature up to 45 C e Meets marine vibration test requirements Battery Integration System to support up to 8 modules 1 hour runtime 1 transformer module Ideal for critical applications requiring high operating continuity Compatible with the most demanding environments Power management e Solution Pac 2 software suite on CD Supplied as standard e Optional ConnectUPS SNM P Webcard Connect to Ethernet alarms and supervision using a Web interface EMP Environmental Monitoring Probe e SNMP and Web monitoring of temperature RH status of 2 contacts e NMS Supervision through Intelligent Power M anager or NMS integration kit HP Openview Tivoli Netview CA Unicenter J bus Modbus card For connecting the UPS to a building management system TECHNICAL SPECIFICATION Technology 7 kVA 11 kVA online double conversion with PFC Power Factor Correction system M Active power kVA kW 7 49 11 8 Rated input voltage 200 208 220 230 240 250V single phase or 380 400 415V three phase Input voltage range 30 20 230 V 20 15 400 V 30 20 230 V 20 15 400 V Input output frequency range 40 70 Hz 50 60 HZ autoselection frequency converter as a standard Output voltage THDU 2
12. utilise electrical power more efficiently while significantly improving environmental performance a An Eaton Green Solution At Eaton we apply the ISO 14001 an international environmental management system on site and R amp D certification to all of our facilities In addition to clearly demonstrate and communicate the environmental value of the products to customers and consumers Eaton has developed a rigorous evaluation process based on the guidelines of international organisations such as the International Standards Organisation ISO Eaton products and services meeting the environmental standards of this process earn the Eaton Green Leaf label Though all of our products are designed to meet government standards and public expectations for protecting the environment Green Leaf products and solutions go well beyond normal Standards to provide exceptional benefit to our customers and the environment We also care for the way our parts and materials are supplied Eaton is a part of Green Suppliers Network a network that helps its component suppliers to develop Lean and Clean manufacturing processes that result in reduced waste and saved money all while reducing their impact on the environment For more information on how Eaton is Sustainable by Design please visit www eaton com sustainability Power Quality Business Eaton Power Quality Division a part of the Electrical Sector has more than 45
13. years of experience in designing and producing innovative power quality products The result is an expansive portfolio of products which help to protect our customer s business processes critical applications and systems from all power problems and failures Eaton product and service range e AC UPS from 350 VA to 4000kVA e DC systems of all sizes e A broad portfolio of rack based power distribution units ePDU e Software and connectivity products for power management and remote control e Technical support and maintenance e Complete power quality solutions Eaton products are manufactured in Finland USA China Taiwan India India Brazil UK and New Zealand About Eatons Pulsar Series Solutions Eaton offers the largest selection of power management and protection solutions available in the industry From the desktop to the data centre from AC powered to DC powered equipment Eaton is your one stop partner for all your power needs Eaton s Pulsar series solutions provide the confidence that power problems will not disrupt your systems data and operation Eaton Corporation s acquisition of M GE Office Protection Systems November 2007 created a larger stronger power quality business with a globally enhanced competitive position and a wide range of single phase UPS products expertise and resources Through the acquisition Eaton has secured its position as the world s second largest manufacturer and supplier of
14. 00 208 230 240 250 V 2 THDU lt 2 200 208 230 240 250 V 2 THDU lt 2 Overall efficiency normal mode 91 eco mode 97 normal mode 91 eco mode 97 THDI THDI lt 5 THDI lt 5 Crest factor short circuit current 3 1 100 A 3 1 150A Overload capacity gt 150 500 ms 150 30 s 125 60 s 110 120 s gt 150 500 ms 150 30 s 125 60 s 110 120 s Temperature operating Back up times at 70 load 45 C for 8 Hrs 40 C continuous 45 C for 8 Hrs 40 C continuous from 10 up to 15 min from 15 up to 20 min Standard 1 power mod 3U 1 battery mod EXB 3U 6U Standard 1 battery mod EXB 3U 9U Standard 1 power mod 3U 1 battery mod EXB 3U 6U Standard 1 battery mod EXB 3U 9U from 40 up to 65 min Connection Standard 2 battery mod EXB 3U 12U Standard 2 battery mod EXB 3U 12U Input output Communication terminal block for 13 mm stranded cable or 10 mm solid cable Port type 6 voltage free contacts DB9 2 A 48 V DC 1 RS 232 RJ 11 for remote emergency power off Slot 1 slot for inter unit communication card 1 slot for inter unit communication card Standard and certification Performance and safety IEC 62040 1 IEC 60950 UL 1778 and CSA 22 2 IEC 62040 1 IEC 60950 UL 1778 and CSA 22 2 EMC IEC 62040 2 EN 50091 2 FCC class A EMC B level IEC 62040 2 EN 50091 2 FCC class A EMC B level Cert
15. 220V 230V 240V Frequency 50 60Hz autoselect 50 60Hz autoselect 50 60Hz autoselect 50 60Hz autoselect Surge protection Integral surge protection device to IEC 61643 1 Total surge absorption 525 J oules Circuit breaker with reset with reset with reset with reset Connection IEC socket 4 4 8 8 UNI socket 2 x IEC 2 x IEC 4 x IEC 4 x IEC 2 x UNI 2 x UNI 4 x UNI 4 x UNI Socket with surge protection amp backup 3 1 3 1 4 4 4 4 socket with surge protection for peripheral Battery Replaceable battery Compact sealed lead acid Compact sealed lead acid Compact sealed lead acid Compact sealed lead acid Battery charger Operates when the UPS is under power Operates when the UPS is under power Cold start no mains Yes Yes Yes Yes Deep discharge protection 4 hours 4 hours 4 hours 4 hours Battery replacement indicator LED audible alarm LED audible alarm LED audible alarm LED audible alarm 50 load backup min 15 13 18 16 70 load backup min Communication 7 6 9 8 Communications port Combined USB and serial port Combined USB and serial port Software supplied as standard Compatible with Windows Linux Novell Mac OS X Compatible with Windows Linux Novell Mac OS X Line protection Standard Tel Fax M odem Intemet Ethernet available for all models Safety IEC EN 62040 1 1 IEC EN 60950 CB Report CE mark IEC EN 62040 1 1 IEC
16. 2U RT2U tower rack 2U Line Interactive High Frequency Booster Fader RT2U tower rack 3U Input voltage and frequency range without using battery 160V 294V adjustable to 150V 294V 47 to 70 Hz 50 Hz system 56 5 to 70 Hz 60 Hz system up to 40 Hz in low sensitivity mode programmable using Personal Solution Pac software Output voltage and frequency 230 V 6 10 Adjustable to 200 V 10 derating of output power 208 V 220 V 230 V 240 V 50 60 Hz 0 1 Connection Input 1 IEC C14 10 A socket 1 IEC C20 16 A socket 1 IEC C20 16 A socket Output 8 IEC C13 10 A 8 IEC C13 10 A socket 8 IEC C13 10 A socket 1 IEC C19 16 A socket 1 IEC C19 16 A socket Remotely controlled socket 2 groups of 2 x IEC C13 10 A 2 groups of 2 x IEC C13 10 A 2 groups of 2 x IEC C13 10 A Additional outputs with HS MBP 3 BS socket or 6 IEC 10 A socket or terminal blocks HW version Additional outputs with FlexPDU Battery 6 BS socket or 12 IEC 10 A socket Typical backup times for 50 and 70 load Evolution S min Evolution S 1 EXB min Evolution S 4 EXB min Battery management Interface 20 14 105 60 300 200 17 11 85 55 290 200 15 10 60 42 210 135 Automatic weekly test period adjustable automatic recognition of external battery units gt continuous maximisation of backup time deep discharge protection Communication port
17. 5 kVA 5 kVA redundancy 15 kVA 10 kVA 5 kVA redundancy 5 kVA 2 x5 kVA redundancy 20 kVA 15 kVA 5 kVA redundancy 10 kVA 2 x5 kVA redundancy Number of phase input connection L N terminals up to 6 mm L N or 3P N terminals up to 35 mm separate or common AC normal and AC bypass Nominal voltage 200 208 220 230 240 250 V 200 208 220 230 240 250 V L N or 380 400 415 V 3P N Voltage range without using battery 120 280 V 120 280 V L N 250 465 V 3P N Input frequency range THDI Output 40 70 Hz lt 7 40 70 Hz lt 7 40 70 Hz lt 7 Output connection terminals 8 IEC C13 10A 2 IEC C19 16A terminals 8 IEC C13 10A 4 IEC C19 16A Remotely controlled Powershare socket 2 groups 2 IEC C13 10A per group 2 groups 2 IEC C13 10A per group 2 groups 2 IEC C13 10A per group Output voltage and frequency THDU efficiency Backup time 200 208 230 240 250 V 50 60 Hz autoselect frequency converter as standard lt 2 97 M X standard backup time 70 load 10 min 8 min 8 min MX EXB MX 2 EXB MX 3 EXB 35 60 95 min 35 min 3 EXB 60 min 6 EXB 90 35 min 4 EXB 60 min 8 EXB 90 min 9 EXB min 12 EXB Communication Slot 1 slot or 2 slots Frame compatible with ConnectUPS NMC ModBus J Bus Contact Serial Port Remote Power off RJ 11 5 output contact DB9 setup using Solution Pac 8
18. EN 60950 CB Report CE mark EMC IEC 62040 2 EN 50091 2 IEC 62040 2 EN 50091 2 IEC 62040 2 EN 50091 2 IEC 62040 2 EN 50091 2 Surge protection Mounting color dimension and weight IEC 61643 1 IEC 61643 1 IEC 61643 1 IEC 61643 1 Dimension HxWxD in mm 270x82x265 270x82x265 305x80x312 317x80x390 Weight kg 4 2 4 4 8 1 11 19 rack mounting kit 2U 2U 2U 2U Colour Titanium Grey Titanium Grey Titanium Grey Titanium Grey Part number UNI 66771 66775 66779 66783 IEC 66772 66776 66780 66784 11 Power protection for workstations and small servers Ellipse MAX Technology Level 5 Line Interactive Rating 600 1500VA Configuration Tower Rack Availability e Line Interactive technology Ellipse MAX provides effective protection even in disturbed electrical environments Fluctuations in voltage are automatically corrected by an AVR device booster fader without using the batteries Surge protection Ellipse MAX includes a high performance Surge protective device which complies with IEC 616431 standard Robust A wide tolerance of input voltage avoids excessively frequent changeover to battery power This means that maximum capacity is always available Value e Easy installation Ellipse MAX USBS models are supplied with power management software amp communications cables 12 Flexibility e Connection 4 or 8 standard IEC outlets IEC version also available
19. Integration Ellipse MAX can be installed in vertical position over amp under the desk or horizontally under a monitor Rackable the optional 2U kit allows you to install the Ellipse MAX in a 19 rack Power management the Ellipse MAX models feature a combined USB and serial port Associated communication Personal SolutionPac power management software the essential option Monitoring and system shutdown e UPS control panel Log e Alarms sent by SMS or e mail e When there is a long power cut the system shuts down or hibernated under Windows and restarts automatically e Advanced personalisation features for expert users Practical e Compatible with Windows MacOS Linux e USB or serial port connection e Supplied on CD ROM and can be downloaded from www eaton com powerquality TECHNICAL SPECIFICATION 600 USBS 850 USBS 1100 USBS 1500 USBS Rating VA Watt 600 VA 360 W 850 VA 550 W 1100 VA 660 W 1500 VA 900 W Technology Line Interactive High Frequency Automatic Voltage Regulation Characteristic Input voltage 165 V 285 V adjustable to 150V 285 V 165 V 285 V adjustable to 150V 285 V Output voltage on battery 230 V adjustable to 220 V 230 V 240 V 230 V adjustable to 220 V 230 V 240 V Frequency 50 60 Hz autoselect 50 60 Hz autoselect 50 60 Hz autoselect 50 60 Hz autoselect Surge protection Integral surge protection device to IEC 61643 1 Total surge absor
20. Solutions the user is notified immediately of the status of the power quality and distribution system and can initiate automatic actions depending on the events control the system remotely and manage it more effectively Benefits of using Eaton s Power Management Solutions Real time notification makes it easy to prevent or analyse possible failures immediately Helps to prevent data losses by enabling controlled shutdown of servers and PC operating systems e View and analyse power events and measured values from recorded logs Save time and money with remote equipment control which removes the need for additional site visits to restart equipment It also enables prolonged runtime of essential equipment during power outages by allowing orderly remote shutdown of non critical systems and processes Connection to IP networks There are two ways of connecting a UPS to an IP network e adding aWeb SNMP card to the UPS which becomes the Interface to the network e using a nearby PC or server connected to the network as a proxy 28 Network Management Card Web SNMP cards are recommended for central UPS systems that protect a complete network or for UPS systems providing backup for critical equipment When the card is fitted the UPS has its own IP address with local intelligence to serve web pages with reports settings and alarms plug in to SNM P based network management systems such as Openview IBM Tivoli Netview and Com
21. can choose the most relevant views for their needs Complete information and control is only a click away since there is a link to the web interface of each individual device Secure operation Intelligent Power Manager uses Secure Sockets Layer SSL and several levels of password administrator user and so on for comprehensive security Scalable and cost efficient A version of Intelligent Power M anager limited to 10 monitored devices is available free with each networked UPS This version can also be used to evaluate the software for use with a more extensive network before purchasing the full version which can be used to manage 100 or more power devices UPSs and ePDUSs Eo EEE E a Protection shutting down servers To ensure the integrity of the system and the data a computer operating system must be shut down in the correct sequence Dedicated shutdown software must be installed on the servers to execute various functions before the power supply is cut off These functions include e executing a script to close applications running on the server e initiating a shutdown sequence or hibemation after a preset timeout or just before total battery discharge e rebooting the operating system automatically or manually when the mains power is restored e showing UPS alerts to the user The Network Shutdown Module can be used to carry out actions selectively for redundant UPS systems Servers with multiple power sup
22. ckup times 1 to 4 EXB battery units can be added to the Evolution S e Pure sinewave output when operating in batterie mode the Eaton Evolution still provides high quality output signal for sensitive connected equipment Minimum total cost of ownership e Line interactive HF technology the best price performance ratio e No additional cost all models are provided with tower stands and rail kits e Remote supervision a wide range of options using the Eaton Software suite including point to point power management SNMP relay outputs etc 16 Total flexibility e Format Evolution S is available in RT2U convertible rack tower version optimised for rack mounting or RT3U for tower or Short depth racks e Connections with FlexPDU and HotSwap MBP the Evolution S can be connected by sockets or terminal blocks They can be installed as required behind on the side or on top of the unit e Compatible with high power factor loads the Evolution S are rated for 0 9 total power factor 1250 VA 1150 W 1750 VA 1600 W 2500 VA 2250 W and 3000 VA 2700 W e Communication the Evolution S includes both serial and USB ports plus remote On Off connector and an extra slot for optional communication cards The UPS comes with a complete Eaton software suite TECHNICAL SPECIFICATION Rating VA Watt 1250 1250 VA 1150 W 2500 2500 VA 2250 W 3000 3000 VA 2700 W Format Characteristic Technology RT2U tower rack
23. ction IEC 61643 1 IEC 61643 1 IEC 61643 1 IEC 61643 1 Mounting dimension and weight Dimension HxWxD in mm 314x82x301 314x82x410 314x82x410 314x82x410 Weight kg 5 75 10 2 10 2 10 2 19 rack mounting kit 2U 2U 2U 2U Part number UNI 68547 68551 68555 68559 IEC 68548 68552 68556 68560 13 High density protection for network devices Evolution Technology Level 5 Line Interactive Rating 1550 2000 VA Configuration Tower Rack Maximum availability Total flexibility Powershare the Eaton Evolution output sockets are Format Evolution is available in tower format RT2U individually controlled to provide load shedding to maximise convertible rack tower 2kVA model the backup time and provide remote reboot and sequential e Communication the Evolution includes both serial and start up as standard USB ports plus remote On Off connector and an extra slot Continuous power supply Hot swappable batteries The for optional communication cards The UPS comes with a optional HotSwap MBP Maintenance By Pass module allows complete Eaton software suite the UPS to be replaced without interrupting the power supply e Pure sinewave output when operating in batterie mode the Eaton Evolution still provides high quality output signal for sensitive connected equipment Minimum total cost of ownership e Line interactive HF technology the best price performance ratio e No additional cost RT models are provided wit
24. ght potential problems in harsh environments Based on the parameters defined by your application you can select a UPS from the level that best matches your power protection needs Basic solution Protection from three potential problems G Power Failure Power Surge pan Intermediate solution Protection from five potential problems 0 Power Power Failure Sag Power Surge Under voltage lls Complete solution Protection from all nine potential problems O 0 Power Under gah Power Failure Surge voltage eae Line Frequency Switching Harmonic Noise Variation Transient Distortion Cost effective solution for protection personal and professional PC Nova AVR Technology Level 5 Line Interactive Rating 625 1250 VA Configuration Tower The NOVA AVR range of UPS units provide the user with cost effective and rugged protection against electrical interference and power outages e Line Interactive technology automatic voltage correction via Booster Fader e Wide tolerance to fluctuations in the Power Management via USB interface Personal Solution Pac software can be interfaced with NOVA AVR for advanced Power management UPS monitoring automatic system shutdown Telephone Modem Broadband line filtering for total IT protection The NOVA AVR is equipped with protection for the telephone fax modem and Intemet line including ADSL essential in order to
25. h the rail kits e Remote supervision a wide range of options using the Eaton Software suite including point to point power management SNMP relay outputs etc 14 TECHNICAL SPECIFICATION 1550 2000 Rating VA Watt 1550 VA 1100 W 2000 VA 1600 W Format Tower RT2U tower rack 2U Characteristic Technology Line Interactive High Frequency Booster Fader Line Interactive High Frequency Booster Fader Input voltage and frequency range without using battery 160V 294V adjustable to 150V 294V 47 to 70 Hz 50 Hz system 56 5 to 70 Hz 60 Hz system up to 40 Hz in low sensitivity mode programmable using Personal Solution Pac software Output voltage and frequency Connection 230 V 6 10 Adjustable to 200 V 10 derating of output power 208 V 220 V 230 V 240 V 50 60 Hz 0 1 Output 4 IEC C13 10 A 8 IEC C13 10 A Remotely controlled socket 2 groups of 1 x IEC C13 10 A 2 groups of 2 x IEC C13 10 A Additional output with HS MBP Additional output with FlexPDU Battery 3 BS socket or 6 IEC 10 A socket or terminal blocks HW version 6 BS socket or 12 IEC 10 A socket 6 BS socket or 12 IEC 10 A socket Typical backup times for 50 and 70 load min Battery management Interface 14 7 14 7 Automatic weekly test period adjustable automatic recognition of extemal battery unit gt continuous maximisation of backup time deep discharge protection Com
26. ification UL 2 TUV GS mark CB C Tick CE IEC 68 2 6 vibration tests Marine approval Dimension HxWxD in mm weight single phase input three phase input EX RT standard backup tower EX RT standard backup Network Pack rack mounting 444 5x2612x700 88 3 kg 89 5 kg 2612 6U x444 5x700 96 1 kg 973 kg 444 5x2612x700 94 2 kg 95 3 kg 2612 6U x444 5x700 102 kg 103 1 kg Comet EX RT Power module 444 5x130 6x700 130 6 3U x444 5x700 23 kg 24 2 kg 444 5x130 6x700 130 6 3U x444 5x700 24 9 kg 26 kg Battery module EXB RT 444 5x130 6x650 130 6 3U x444 5x650 64 5 kg 444 5x130 6x650 130 6 3U x444 5x650 68 5 kg EX RT CLA module EX RT Transformer 130 6 3U x444 5x650 12 kg 87 kg 130 6 3U x444 5x650 12 kg 87 kg Part number Single phase 68070 68110 Three phase 68074 68114 EXB 68078 68118 1 applicable to single phase models 2 single phase input value 3 at nominal output power for 230 V or 400V input and 230V output 4 typical values after 3 discharge cycles batteries 3 5 years longer backup times available using the CLA or EXB module ask for details 5 option for single phase model 23 Source Transfer Switch STS 16 With the Pulsar STS 16 power from 2 independent sources can be supplied to servers and circuit equipment which only have one input power supply Redundancy At present only top of the range servers are eq
27. imension HxWxD in mm 44x483x80 BS 52x483x120 52x483x120 89x483x90 Connection Input 1 IEC C20 16A connector and 2 IEC models 1 IEC C20 16A Pre wired 0 5 m cable for connection cables 1 IEC 16A 16A cable and 1 connector and 1 IEC 16A 16A to the UPS terminal block IEC 10A 16A cable for connection cable 1 HW Hard Wired terminal to any UPS block Output IEC 12 IEC 10A socket 1 IEC 16A 6 IEC sockets 1 IEC 16A socket 8 IEC 10A sockets 4 IEC 16A socket with 2 circuit breakers with 1 circuit breaker socket with 4 circuit breakers HW NA Terminal block Cascading yes IEC 16A output socket except HW Retaining clip retaining clip on the IEC input and output socket Operating condition standard and approval Operating temperature 0 C to 45 C continuous 0 C to 45 C continuous 0 C to 45 C continuous Performance Safety EMC IEC models IEC 60 320 1 EN 60 320 1 HW models IEC 60 950 EN 50 IEC EN 60 320 1 091 Approval CE CE CE Part number IEC 68438 68433 BS 68437 68432 HW 68434 66857 27 Equipment reliablity and data integrity Power Management Solutions Improve equipment reliability and guarantee data integrity Uninterruptible power supplies UPSs are used as backup systems in case of a power failure to prevent downtime This type of protection is essential but is only fully effective if the user is in control of the situation With Eaton s Power Management
28. munication port 1 USB port 1 RS232 serial port and relay contacts USB and RS232 ports cannot be used simultaneously 1 mini terminal block for remote ON OFF and Remote Power Off Communications card slot Operating condition standard and approval 1 slot for NMC Minislot card or NMC ModBus Bus or MC Contacts Senal Operating temperature 0 to 40 C 0 to 40 C Noise level lt 40dbA lt 45 dBA Performance Safety EMC Approvals Dimension HxWxD in mm Weight kg IEC EN 62040 1 1 Safety IEC EN 62040 2 EN 50091 2 class B EMC IEC EN 62040 3 Performance IEC EN 61000 4 2 61000 4 3 61000 4 4 61000 4 5 61000 4 6 61000 4 8 EMI CE CB report T V Dimension of the Tower 234x147x492 440x86 2x509 2U Dimension of the Rack 86 2x440x509 2U Weight of the Tower Rack 16 53 20 25 7 Part Number Tower Rack 68457 68460 15 High density protection for network devices Evolution S Technology Level 5 Line Interactive Rating 1250 3000 VA Configuration Tower Rack Maximum availability e Powershare the Eaton Evolution S output sockets are individually controlled to provide load shedding to maximise the backup time and provide remote reboot and sequential Start up as standard e Continuous power supply Hot swappable batteries The optional HotSwap MBP Maintenance By Pass module allows the UPS to be replaced without interrupting the power supply e Long ba
29. nt shutoff For example if the utility fails you could lose all of your work in progress The Level 3 UPS offers a degree of protection against the remaining power problems and is most commonly used to protect single workstations and point of sale POS equipment Level 5 UPS are most effective against five power problems power failures power Sags power Surges under voltage and over voltage and offer a degree of protection against other power problems Some of the damages you risk by not using a Level 5 UPS include premature hardware failure data loss and corruption data error keyboard lockup storage loss and system lockup Level 5 UPS are recommended for small network systems all the way up to enterprise networking environments Level 9 UPS protects against all nine power problems power failures power Sags power surges under voltage electrical line noise over voltage frequency variation switching transients and harmonic distortion Level 9 comprehensive protection minimises the opportunity for component stress bumt circuit boards data crashes and program failures Level 9 UPSs offer the highest level of power protection available and are always recommended for mission cntical applications like server farms hospitals and Voice Over Internet Protocol VOIP applications Eaton products offer three levels of power protection Level 3 Level 5 and Level 9 plus the rugged FERRUPS product line that provides protection from ei
30. nto any type of installation they can be rack mounted horizontally 1U or vertically or directly onto all MGE RT format rack tower UPSs Comet PDU Socket blocks for single phase UPS with output terminal blocks e Comet PDUs Power Distribution Units make it easy to connect equipment to single phase UPS with output terminal blocks Comet EX RT etc e Comet PDU Power Distribution Units contain 8 IEC 10A and 4 IEC 16A sockets on a 2U rack mounting module All the outputs have retaining clips for highly reliable connections 26 HotSwap MBP High availability for all UPSs up to 3 kVA e HotSwap MBP provides a maintenance bypass for all UPSs up to 3 kVA UPSs can be hot swapped or upgraded without Interrupting the power supply e HotSwap MBP has an IEC16A input connector with retaining clip for compatibility with any UPS now and in the future from Eaton or any other supplier e HotSwap MBP units can be installed as required at the back Side top of the UPSs or rackmounted horizontally 15U or vertically TECHNICAL SPECIFICATION FlexPDU HotSwap MBP Comet PDU Current rating 16 A 16 A 52A Voltage rating 220 230 240 250 V 220 230 240 250 V 220 230 240 250 V Installation Format 1U except BS 19 rack mounting gt 1U 19 rack mounting with multi 2U 19 rack with multi position mountings position mountings Installation 19 rack horizontal or vertical 19 rack or wall mounting mounting or on RT UPSs D
31. omputer bays Environmental conditions temperature humidity and opening and closing of doors can also affect system availability To address this Eaton provides an environment sensor which incorporates a temperature sensor humidity sensor and two switch inputs It is designed to work with Web SNMP cards and can be easily installed in various environments Linux and Eaton uninterruptible power supplies For several years Eaton has been actively supporting the trend towards open source software by providing the most advanced power management facilities One example is the new Personal Solution Pac management system for Linux which is based on the open source code to which Eaton has made a significant contribution Connection to IP networks Network M anagement Card Web Web browser Power Manager Unix Network Shutdown Module x Network Management Proxy Intelligent L l NMS Snap IN MacOSX Network Management Card gt 1 Environment sensors Imdividual computer applications When the UPS is protecting only one device the point to point link RS232 or USB is used The operating system plug and play solution Some operating systems such as Windows have built in power management functions for critical tasks Eaton s Pulsar series UPS units are plug and play when the UPS is connected to the system using a USB cable the operating system detects the UPS automatically and ins
32. plies paralleled UPSs etc to provide the highest availability and data integrity for the most critical data Eaton Network Shutdown Modules operate equally well with Web SNMP card and SNMP proxy systems and can easily be configured remotely via a browser Additional functions Individual outlet socket control The Network Shutdown Module can be used to carry out actions Many systems from Eaton have individual output receptacles for turning groups of devices on and off This feature is particularly useful for e shedding non critical systems when there is a power cut e defining start up sequences e individual management of several IT systems connected to a central UPS Remote on off control As an entire UPS or some of its outlets can be turned on and off remotely it becomes a smart IT equipment switch This function makes it possible for example to restart a locked up hardware device from a remote site Outlet control can be automatic or manually controlled locally or remotely Saving energy function This function can be used to program shutdown and restart sequences for all UPS protected devices For example workstations printers network devices and selected servers can be shut down and powered off outside of business hours 29 Supervision Protection Windows Network connection Other options Environment Sensor for Web SNMP card UPSs are often used in sensitive environments such as c
33. prevent surge and the destruction of sensitive electronic components Ideal protection for 1 to 3 PCs either in a business environment or at home The NOVA AVR range of UPS units provide the user with cost effective and rugged protection against electrical interference and power outages Ideal protection for 1 to 3 PCs either in a business environment or at home Easy to use and maintain Very simply the NOVA AVR uses e 3 indicator lamps to display the principal states ON OFF Replace Batteries Fault supplemented by audible alarms e The batteries are easy to replace Its cold start function can tum the NOVA AVR into a mobile power source for IT equipment TECHNICAL SPECIFICATION 625 AVR 1250 AVR Rating VA Watt 625 VA 360 W 1250 VA 660 W Characteristic Input voltage 165 V to 280 V 160 V to 290 V Output voltage 230V 230V Frequency 50 60 Hz auto detection 50 60 Hz auto detection Surge protection Total energy dissipation 220 J oules Total energy dissipation 220 J oules Protection Fuse Circuit breaker user resettable circuit breaker Fuse Circuit breaker user resettable circuit breaker Data line protection Protection for Telephone M odem Intemet line including ADSL Connection Output 3 x IEC 4 x IEC Technology Line Interactive with Booster 18 and Fader 15 Line Interactive with Booster 18 and Fader 15 Battery Battery recharging Continuous battery recharging even
34. ption 525 J oules Circuit breaker with reset with reset with reset with reset Connection IEC socket 4 8 8 8 UNI socket 2 x IEC 4 x IEC 4 x IEC 4 x IEC 2 x UNI 4 x UNI 4 x UNI 4 x UNI Socket with surge protection and backup 3 1 4 4 4 4 4 4 socket with surge protection for peripherals Battery Replaceable battery Compact sealed lead acid Compact sealed lead acid Compact sealed lead acid Compact sealed lead acid Battery charger Operates when the UPS is under power Operates when the UPS is under power Battery management Battery test Cold start no mains Deep discharge protection Battery replacement indicator LED audible alarm LED audible alarm LED audible alarm LED audible alam Typical backup times for 50 and 70 of the VA rating min Communication 12 7 18 12 15 9 12 7 Communication port Combined USB amp Serial port Combined USB amp Serial port Software supplied as standard Line protection Compatible with Windows Linux Novell Mac OS X Tel Fax M odem Internet and Ethernet 10 100 M B Compatible with Windows Linux Novell Mac OS X Tel Fax M odem Internet et Ethernet 10 100 MB Standard Safety IEC EN 60950 1 IEC EN 62040 1 1 CB Report CE mark IEC EN 60950 1 IEC EN 62040 1 1 CB Report CE mark EMC IEC 62040 2 EN 50091 2 IEC 62040 2 EN 50091 2 IEC 62040 2 EN 50091 2 IEC 62040 2 EN 50091 2 Surge prote
35. puter Associates Unicenter e communicate with shutdown software installed on the servers to be protected Network Management Proxy The Web SNMP Proxy is a more economical solution for small UPS systems It allows a UPS to be controlled over the network without adding to the basic cost of the UPS The proxy software agent is installed on the system to which the UPS is connected via a USB or RS232 port The Web SNMP Proxy agent is used to manage a UPS remotely using a standard browser or network management system UPS system supervision Supervision using a web browser A Network Management Card enables UPS management using a standard web browser The web interface provides details of all UPS parameters measurements and settings from any point in the network by using the IP address of each UPS Supervision using a Network Management System NMS SNMP protocol is the standard way of monitoring networked devices such as servers switches routers disks and also UPSs among other devices Eaton Network Management Cards communicate with leading NM Ss for example HP OpenView BM Tivoli and CA Unicenter using SNMP Network administrators can use the same familiar tools and alarm management methods for UPS monitoring as for any other piece of IT equipment Eaton provides SNMP MIBs Management Information Base which cover all the Eaton product specific functions and data They can be easily incorporated into NMSs or server management soft
36. rge cycles with 3 5 year old batteries Weekly battery test without interrupting the load daily or monthly if required EXB compatible with 0 8 power factor loads With MX Frame EXB 4 battery units Solution Pac CD ROM supplied as standard Applicable to US models 0 50 dbA above 5 kVA 21 Perfect for rack servers enclosures and industnal environment EX RT Technology Level 9 Double Conversion Online Rating 7 0 KVA Configuration Tower Rack Convertible High availability Hot swappable UPS and battery modules Internal bypass and maintenance bypass included as standard The UPS can be connected to two independent electrical sources sources 1 and 2 can be common or separate Large input voltage range without draining the battery 230V 20 to 30 single phase and 400V 15 to 20 three phase Batteries tested automatically at regular intervals and protected against deep discharge N 1 redundancy supported by two single units Wide choice of backup times e From 10 minutes to 2 hours with battery modules or up to 8 hours using the CLA charger module e Optional Battery Integration System for automatic recognition of battery modules and minimising size Ergonomy Multilingual LCD display and LEDs for rapid view of the UPS Status and the operating log e Self diagnosis and fault messages 22 Computer Tower 6U Rack convertible e Comprehensive range of Power Distribution Units for convenient
37. se ASR Advanced Surge Reduction UPSs include a high e Alarms sent by SMS or e mail performance surge protective device which complies with IEC e When there is a long power cut the system shuts down or 616431 hibernated under Windows and restarts automatically e Ellipse ASR UPS also protects telephone broadband and e Advanced personalisation features for expert users Ethernet for complete protection e Compatible with Windows MacOS Linux e USB or serial port connection The widest range of sockets e Supplied on CD ROM and can be downloaded from www 4 IEC sockets 600 750 models or 8 IEC sockets 1000 1500 eaton com powerquality models The greatest flexibility Extra flat for easy installation in all business environments Vertical box format or below the desk e Horizontal under a monitor e 19 rack mounted optional 2U kit The best compatibility with computer equipment The Ellipse ASR is designed for compatibility with a wide variety of computers e Combined USB and serial ports e Power management software e Available under Windows Linux and Mac OS 10 TECHNICAL SPECIFICATION 600 USBS 750 USBS 1000 USBS 1500 USBS Rating VA Watt 600 360 750 450 1000 600 1500 900 Technology Standby Standby Standby Standby Characteristic Input voltage 184V to 264V adjustable from 161V to 284V 184V to 264V adjustable from 161V to 284V Output voltage 230V settable to 220V 230V 240V 230V settable to
38. sive management of a set of UPS using a Windows PC Relay Interface Card To provide UPS status outputs via relay contacts emergency stop and a second serial port ModBus Bus card For combined SNMP HTML and ModBus Bus supervision TECHNICAL SPECIFICATION Rating VA Watt 1000 1000 RT2U 1000 VA 900 w 1500 1500 RT2U 1500 VA 1350 w 2000 2200 VA 1980 W 3000 3000 VA 2700 w Technology Online double conversion Online double conversion Online double conversion Online double conversion Format Mini tower or RT2U tower rack 2U RT2U tower rack 2U RT2U tower rack 2U Characteristic Architecture Online double conversion with automatic by pass and power factor correction Input voltage and frequency range without using battery 100 120 140 160 V to 284V 40 to 70 Hz 100 120 140 160 V to 284V 40 to 70 Hz Output voltage and frequency 230V adjustable to 200 208 220 240 250 V 50 60 Hz auto select or frequency converter mode A Connection Input 1 IEC C14 10A socket 1 IEC C14 10A socket 1 IEC C20 16A or terminal block on HotSwap M BP Hard Wired Output 6 IEC C13 10A socket 6 IEC C13 10A socket 8 IEC C13 10A socket 1 IEC C19 16A socket Remotely controlled Powershare socket 2 independent groups 2 1 IEC C13 10A socket 2 groups of 2 x IEC C13 10A Outputs with HotSwap M BP 6 IEC 10A socket or terminal blocks HW version or 3 BS socket Ou
39. talls the appropriate drivers Personal Solution Pac Additional control and settings to those built in the operating system can be provided by the Eaton Personal Solution Pac This system can be used to fine tune shutdown parameters and provide additional capabilities such as controlling individual devices programming responses to events and calculating true backup time in case of mains power loss 66 102 NMC Minislot for Eaton Evolution and Eaton Evolution S Eaton EX Eaton MX Eaton MX SNMP Frame Eaton EX RT SNMP Proxy On the Solution Pac 2 CD ROM delivered with most UPSs or free from the web www eaton com powerquality Protection Network Shutdown Module powerquality Remote management and monitoring On the Solution Pac 2 CD ROM delivered with most UPSs or free from the web www eaton con Snap in application for HP Compaq Insight M anager Available free of charge from the web www eaton com powerquality M anagement Pac 66923 Intelligent Power Manager Base license up to 10 devices Available on the CD bundled with each UPS or free of charge from the web www eaton com powerquality Support for 11 100 IP addresses 66925 Support for unlimited IP addresses 66926 Other option Environmental Sensor 66846 30 suolldnisip u usnoiu 1ISAOd MH 9 Dal Pey MoL JqHAUOD MH 9 4l Pey MoL JqHAUOD 941 De YAMOL JAl lqr u AuoO 3 gt 5 W lAO
40. tputs with FlexPDU Battery 12 IEC 10A socket 12 IEC 10A socket 12 IEC 10A socket 12 IEC 10A socket Typical backup times for 50 and 70 load EX min 16 12 13 9 17 12 15 10 EX 1 EXB min 75 50 50 35 85 60 60 40 EX 4 EXB min 250 200 180 120 285 200 190 150 Battery management Interface Automatic weekly test period adjustable using LCD display or in software supplied automatic recognition of external battery unit gt continuous maximisation of backup time deep discharge protection Indicators and display 3 LEDS adjustable multilingual display display of measurement access to control and set up menu Communication port 1 USB port 1 RS232 serial port and relay contact 1 mini terminal block for remote ON OFF and emergency stop Communications slot Operating condition standard and approval 1 slot for NMC Minislot card or NMC ModBus Bus or MC Contact Serial Operating temperature noise level 0 C to 40 C continuous 45 dBA 0 C to 40 C continuous 45 dBA Performance Safety EMC IEC EN 62 040 3 VFI SS 113 IEC EN 62 040 1 1 IEC EN 60 950 1 RD IEC EN 62 040 2 C1 Class Approval CE TuV GS CB report cTuV US CE TuV GS CB report cTuV US Dimension HxWxD in mm Weight kg Tower 440x242x153 15 kg 490x242x153 18 kg 640x86x440 2U 31kg 640x86x440 2U 31kg 490x131x440 3U 30 kg 490x131x440 3U 30 kg Rack 86 5x438x483 86 5x438x483
41. uipped with a dual electrical power supply In their original form the majonty of these types of equipment including concentrators switches auto routers invoicing servers SMS servers and middle of the range servers are single connection that is to say they have only one electrical input supply With the Pulsar STS every rack of critical equipment can be connected to a redundant power Supply Both sources primary and secondary are connected in a very Straightforward manner to the STS in the base of the rack The Pulsar STS then controls the redundancy of this electrical power supply If the primary source fails transfer to the secondary source is automatic and instantaneous Simple and cost effective Considering its advanced design the price of the Pulsar STS is highly competitive compared with the dual power supply options available from suppliers of computer equipment LU high the unit can be installed easily within the rack Five LEDs indicate the status of the sources and the STS 24 Reliability Designed to provide redundancy as close as possible to the equipment the Pulsar STS deploys a break before make technology based on relays e In the event of a short circuit the Pulsar STS ensures that the fault cannot affect the alternative source so that power continues to be supplied to the fault free equipment e Power is transferred without overlap of the sources in order to prevent any node of reliabilit
42. ware Supervision using Intelligent Power Manager Easy supervision of power protection and distnbution Intelligent Power M anager is a software tool for managing networked UPS and PDU systems more easily and at lower cost than the major NMS platforms and is a dedicated tool for power management functions Administrators have an overall consolidated view of the main operating parameters of all UPS systems The web based interface is intuitive and easy to use while also having high configurability and powerful features Devices can be grouped by function or location and sorted according to parameters like status description type and location Device icons can be freely placed on background images such as maps or floor plans to aid identification Powerful alarm management Intelligent Power M anager centralises alarm management It can collate several events into a single message and deliver the message via email or SMS Events and actions are stored in a log to help in analysing and mitigating power problems The calendar view provides quick way to get an overview of event history Simple start up Intelligent Power M anager Is very easy to install only a few clicks of the mouse are needed Once running the software discovers manageable power devices automatically and is operational in just a few seconds Informative views Intelligent Power Manager features several view panels which summarise the operational status of a UPS Users
43. y e Even if it suffers a fault the Pulsar STS continues to supply power to the equipment from the remaining available source Associate communication A simple and complete mimic diagram displays the various Status of the sources and the Pulsar STS An STS COM communication port of the dry contact type indicates the status of the sources and the Pulsar STS primary source e source OK e fault within the Pulsar STS TECHNICAL SPECIFICATION STS 16 Nominal current 16 A Compatibility with all uninterruptible power supplies which use on line double conversion technology Voltage input frequency 208 220 230 240 V 12 50 60 Hz Output protection 1 thermal cutout per set of IEC 13 connectors Input 2 connecting cables with IEC C20 connector 16 A male connector Output 2 set of 3 IEC C13 connector 1 set of 1 IEC C19 connector Transfer time Safety EN 50091 1 EMC EN 50022 B IEC 1000 4 Marking CE TUV GS UL Dimension 430x43x250 Net weight STS 16 66028 25 Power Distribution for UPS Flex PDU HotSwap MBP Comet PDU FlexPDU Having the right connectors just where you need them e FlexPDUs Power Distribution Units are flexible mounting multiway socket blocks for easy connection of multiple loads or either free standing or rack mounted UPSs e FlexPDUs have a large number of sockets 12 IEC 10A sockets which fit into a very compact unit 1U 19 e FlexPDUs are easy to implement i

Download Pdf Manuals

image

Related Search

Related Contents

AvanTax eForms Help & User Guide  Yosemite Home Decor LINDSEY-RB Instructions / Assembly  Philips Carafe HD5212  START! 楽しい 簡単編集 ビデオカメラ  Avvitatore pneumatico ad aria ISTRUZIONI PER L`USO E    Dell B5465dnf Administrator's Guide  M - Crown Equipment Corporation  Operator Control and Monitoring Devices  Magnavox MBP5320F Setup Guide  