Home
Kramer Electronics WP-110XL
Contents
1. 6 Technical Specifications Figures Figure 1 WP 110xl UXGA Data Line Transmitter Figure 2 Connecting the WP 110xl UXGA Data Line Transmitter Figure 3 Ground Connection Figure 4 TP PINOUT Figure 5 WP 110xl US Wall Plate Figure 6 WP 110xl EU Wall Plate COO OND FP WWWNHD a N 00NOA prope Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront video audio presentation and broadcasting professionals on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 14 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products GROUP 12 Digital Signage and GROUP 13 Audio and GROUP 14 Collaboration Congratulations on purchasing your Kramer WP 110xl UXGA Data Line Transmitter which is ideal for the following typical applications e Presentation and multimedia applications e Long range graphics distribution for schools hospital
2. Warranty To obtain a remedy under this limited warranty you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you For a list of authorized Kramer Electronics resellers and or Kramer Electronics authorized service providers please visit our web site at www kramerelectronics com or contact the Kramer Electronics office nearest you In order to pursue any remedy under this limited warranty you must possess an original dated receipt as proof of purchase from an authorized Kramer Electronics reseller If this product is returned under this limited warranty a return authorization number obtained from Kramer Electronics will be required You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product If itis decided that this product should be returned directly to Kramer Electronics this product should be properly packed preferably in the original carton for shipping Cartons not bearing a return authorization number will be refused Limitation on Liability THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY
3. and you may have other rights which vary from country to country or state to state This limited warranty is void if i the label bearing the serial number of this product has been removed or defaced ii the product is not distributed by Kramer Electronics or iii this product is not purchased from an authorized Kramer Electronics reseller If you are unsure whether a reseller is an authorized Kramer Electronics reseller please visit our Web site at www kramerelectronics com or contact a Kramer Electronics office from the list at the end of this document Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the online product registration form Kramer Electronics thanks you for purchasing a Kramer Electronics product We hope it will give you years of satisfaction For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com KRAMER E mail info kramerel com SAFETY WARNING Disconnect the unit from the power e supply before opening and servicing P N 2900 300294 Rev 3
4. capture button item 1 on Figure 5 and Figure 6 The EDID status LED item 2 on Figure 5 and Figure 6 flashes slowly several times The new EDID is captured when the LED stops flashing and lights solid Note If the status LED flashes quickly for a few seconds and then stays on solid the WP 110xI could not capture the EDID and loaded the default EDID instead 5 Unplug the power adapter from the mains and disconnect it from the WP 110xl 6 Replace the faceplate and secure the four screws removed in Step 1 Capturing the E 5 2 Loading the Default EDID To load the default EDID 1 Using a Philips screwdriver remove the four screws holding the faceplate to the PCB assembly 2 Do not connect a display to the PC IN input 15 pin HD connector 3 Connect the 12V DC power adapter to the power terminal block see Figure 1 on the WP 110xI and connect the adapter to the mains electricity 4 Press the EDID capture button item 1 on Figure 5 and Figure 6 The EDID status LED item 2 on Figure 5 and Figure 6 flashes quickly for a few seconds and then stays on solid 5 Unplug the power adapter from the mains and disconnect it from the WP 110xl 6 Replace the faceplate and secure the four screws removed in Step 1 Figure 5 WP 110xI US Wall Plate 10 WP 110xI Capturing the EDID Figure 6 WP 110xI EU Wall Plate WP 110xI Capturing the EDID 6 Technical Specifications INPUT OU
5. of any defective parts within a reasonable period of time free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete 2 Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product 3 Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty What Kramer Electronics will not do Under This Limited Warranty If this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up this product any adjustment of user controls or any programming required for a specific installation of this product How to Obtain a Remedy under this Limited
6. recycling 3 Overview The WP 110xI is a high performance twisted pair TP transmitter for computer graphics signals over extended distances using CAT 5 6 cable The transmitter can be connected to compatible receivers such as the PT 120xl TP 122xI and the TP 126xl for 250m range or the PT 120 TP 120 TP 120 od TP 122 TP 122N TP 122 od TP 124 TP 124 od and the TP 124 for 100m range The WP 110xI comes in three models the WP 110xI 69mm US version and the two WP 110xI 80 86mm European versions More specifically the WP 110xl features Resolution up to WUXGA 1080p HDTV compatibility up to 1080p Extended transmission range of up to 250m 820ft with suitable devices EDID Capture copies and stores the EDID from a display device Increased level of protection against noise spikes and interference in adverse environments 3 1 Defining the WP 110xl UXGA Data Line Transmitter This section defines the WP 110xl WP 110xI Overview WP 110xl EU 80 WP 110xl US WP 110xl EU 86 Figure 1 WP 110xl UXGA Data Line Transmitter Feature Function PC IN 15 pin HD connector Connects to the computer graphics source ON LED Lights green when powered on 12V GND Terminal Block Connects to the 12V DC power supply 4 LINE OUTPUT RJ 45 Connector Connects to the twisted pair receiver for example the PT 120 or TP 126xl Ground Terminal Crimp terminal connects to earth WP 1
7. 10xI Overview 4 Connecting and Installing the WP 110xI Always switch off the power to each device before connecting it to your WP 110xI After connecting your WP 110xI connect its power and then switch on the power to each device To connect the WP 110xI as illustrated in the example in Figure 2 1 Connect the LINE OUTPUT Ru 45 connector on the rear panel of the WP 110xl to the TP receiver for example the PT 120 or the TP 126xl 2 Ground the wall plate see Section 4 1 3 Connect the 12V DC power supply to the 12V and GND terminals taking care to observe the correct polarity 4 Install the WP 110xI into a suitable wall box or rack mount 5 Connect a computer graphics source for example a PC to the PC IN 15 pin HD connector WP 110xI S 1Y9 Ni A To il PT120 TP 126xl Computer Graphics Source Figure 2 Connecting the WP 110xl UXGA Data Line Transmitter WP 110xI Connecting and Installing the WP 110xI 4 1 Grounding the Wall Plate Grounding the WP 110xI is recommended The grounding wire is connected to the rear of the chassis of the unit The grounding screw is used to earth the unit to the ground of the building This helps prevent static electricity from interfering with product performance To connect the grounding to the WP 110xl as shown in Figure 3 1 Crimp the ring tongue terminal to the building grounding point wire We recommend that you use a green yellow 18 AWG wir
8. KRAMER ELECTRONICS LTD USER MANUAL MODEL WP 110x UXGA Data Line Transmitter P N 2900 300294 Rev 3 This guide helps you install and use your product for the first time For more detailed information go to http www kramerelectronics com support product_downloads asp 1 to download the latest manual or scan the QR code on the left Step 1 Check what s in the box A K WP 110xI UXGA Data Line Transmitter A 1 Quick Start Guide A 1 Power supply 12V DC Step 2 Connect the TP line and the power 12V DC PT 120xl 100m Power Supply TP 126x 250m Always use Kramer high performance cables for connecting AV equipment to the WP 110x1 Step 3 Install the WP 110xl Mount the WP 110xl in a suitable wall box and connect a computer graphics source Earth Step 4 Capture an EDID If necessary remove the front panel attach a display and capture the display EDID or load the default EDID without an attached display See Section 5 Contents 1 Introduction 2 Getting Started 2 1 Achieving the Best Performance 2 2 Safety Instructions 2 3 Shielded Twisted Pair Unshielded Twisted Pair 2 4 Recycling Kramer Products 3 Overview 3 1 Defining the WP 110xI UXGA Data Line Transmitter 4 Connecting and Installing the WP 110xl 4 1 Grounding the Wall Plate 4 2 Wiring the TP LINE OUT RJ 45 Connector 5 Capturing the EDID 5 1 Capturing the EDID from a Display Device 5 2 Loading the Default EDID
9. Some countries districts or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or exclusions may not apply to you Exclusive Remedy TO THE MAXIMUM EXTENT PERMITTED BY LAW THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPICABLE LAW IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A CONSUMER PRODUCT UNDER THE MAGNUSON MOSS WARRANTY ACT 15 U S C A 2301 ET SEQ OR OTHER APPICABLE LAW THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU AND ALL IMPLIED WARRANTIES ON THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW Other Conditions This limited warranty gives you specific legal rights
10. TPUT VIDEO RESOLUTION RANGE COUPLING POWER CONSUMPTION OPERATING TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non condensing WALL PLATE SIZE 2 gang EU US DIMENSIONS 2 gang USA 11 4cm x 3 5cm x 11 4cm 4 49 x 1 4 x 4 49 W D H 2 gang Europe 15 2cm x 3 5cm x 8 0 8 6cm 5 98 x 1 4 x 3 15 3 39 W D H WEIGHT 0 14kg 0 31lbs approx ACCESSORIES Power supply OPTIONS 19 rack adapters for EU and US wall plates Kramer on wall boxes 1 VGA UXGA on a 15 pin HD connector 1 RJ 45 LINE OUTPUT connector Up to WUXGA 1080p Up to 250m 820ft 12V DC 70mA gt Specifications are subject to change without notice at http www kramerelectronics com WP 110xI Technical Specifications LIMITED WARRANTY The warranty obligations of Kramer Electronics for this product are limited to the terms set forth below Whatis Covered This limited warranty covers defects in materials and workmanship in this product What is Not Covered This limited warranty does not cover any damage deterioration or malfunction resulting from any alteration modification improper or unreasonable use or maintenance misuse abuse accident neglect exposure to excess moisture fire improper packing and shipping such claims must be presented to the carrier lightning power surges or other acts of nature This limited warranty does no
11. e 0 82mm crimped with a proper hand tool 2 Insert the M3x6 screw through the toothed locking washers and the ring tongue terminal in the order shown in Figure 3 3 Insert the M3x6 screw with the two toothed lock washers and ring tongue terminal in place into the grounding screw hole on the rear of the WP 110xl and tighten the screw l Item Figure 3 Ground Connection 4 2 Wiring the TP LINE OUT RJ 45 Connector This section defines the TP pinout using a straight pin to pin cable with RJ 45 connectors EIA TIA 568B PIN Wire Color 1 Orange White Green White rs oren s eom Figure 4 TP PINOUT W WP 110xl Connecting and Installing the WP 110xI 5 1 Capturing the EDID The WP 110x can capture an EDID from a connected display or can load a default EDID when no display is available or the unit cannot capture the EDID from the connected display Capturing the EDID from a Display Device To capture an EDID from a display 1 Using a Philips screwdriver remove the four screws holding the faceplate to the PCB assembly 2 Using a short cable for example Kramer model number C MGM MGM 1 connect the PC IN input 15 pin HD connector on the WP 110xl to the 15 pin HD connector of the display and turn the display on 3 Connect the 12V DC power adapter to the power terminal block see Figure 1 on the WP 110xI and connect the adapter to the mains electricity 4 Press the EDID
12. he wall before installing Shielded Twisted Pair Unshielded Twisted Pair We recommend that you use Shielded Twisted Pair STP cable and stress that the compliance to electromagnetic interference was tested using STP cable There are different levels of STP cable available and we advise you to use the best quality STP cable that you can afford Our non skew free cable Kramer BC STP is intended for analog signals where skewing is not an issue In cases where there is skewing our Unshielded Twisted Pair UTP skew free cable Kramer BC XTP may be advantageous and UTP cable might also be preferable for long range applications In any event when using UTP cable it is advisable to ensure that the cable is installed far away from electric cables motors and so on which are prone to create electrical interference Recycling Kramer Products The Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility For details of Kramer s recycling arrangements in your particular country go to our recycling pages at http www kramerelectronics com support
13. s stores and security applications troauction 2 1 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Go to http www kramerelectronics com support product_downloads asp to check for up to date user manuals application programs and to check if firmware upgrades are available where appropriate Achieving the Best Performance To achieve the best performance Use only good quality connection cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your Kramer WP 110xI away from moisture excessive sunlight and dust This equipment is to be used only inside a building It may only be connected to other equipment that is installed inside a building WP 110xI Getting Started 2 2 2 3 2 4 Safety Instructions Caution There are no operator serviceable parts inside the unit Warning Use only the Kramer Electronics input power wall adapter that is provided with the unit Warning Disconnect the power and unplug the unit from t
14. t cover any damage deterioration or malfunction resulting from the installation or removal of this product from any installation any unauthorized tampering with this product any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs or any other cause which does not relate directly to a defect in materials and or workmanship of this product This limited warranty does not cover cartons equipment enclosures cables or accessories used in conjunction with this product Without limiting any other exclusion herein Kramer Electronics does not warrant that the product covered hereby including without limitation the technology and or integrated circuit s included in the product will not become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used How Long Does this Coverage Last Seven years as of this printing please check our Web site for the most current and accurate warranty information Whois Covered Only the original purchaser of this product is covered under this limited warranty This limited warranty is not transferable to subsequent purchasers or owners of this product What Kramer Electronics willdo Kramer Electronics will at its sole option provide one of the following three remedies to whatever extent it shall deem necessary to satisfy a proper claim under this limited warranty 1 Elect to repair or facilitate the repair