1. IMC Networks warrants to the original end user purchaser that this product EXCLUSIVE OF SOFTWARE shall be free from defects in materials and workmanship under normal and proper use in accordance with IMC Networks instructions and directions for a period of six 6 years after the original date of purchase This warranty is subject to the limitations set forth below At its option IMC Networks will repair or replace at no charge the product which proves to be defective within such warranty period This limited warranty shall not apply if the IMC Networks product has been damaged by unreasonable use accident negligence service or modification by anyone other than an authorized IMC Networks Service Technician or by any other causes unrelated to defective materials or workmanship Any replaced or repaired products or parts carry a ninety 90 day warranty or the remainder of the initial warranty period whichever is longer To receive in warranty service the defective product must be received at IMC Networks no later than the end of the warranty period The product must be accompanied by proof of purchase satisfactory to IMC Networks denoting product serial number and purchase date a written description of the defect and a Return Merchandise Authorization RMA number issued by IMC Networks No products will be accepted by IMC Networks which do not have an RMA number For an RMA number contact IMC Networks at PHONE 800 624 1070 in the U S and
2. Bas ALKEN Networks IE MediaChassis 2 DC Operation Manual FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment The use of non shielded I O cables may not guarantee compliance with FCC RFI limits This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de classe A prescrites dans le R glement sur le brouillage radio lectrique publi par le minist re des Communications du Canada Warranty
3. Canada or 949 465 3000 or FAX 949 465 3020 The end user shall return the defective product to IMC Networks freight customs and handling charges prepaid End user agrees to accept all liability for loss of or damages to the returned product during shipment IMC Networks shall repair or replace the returned product at its option and return the repaired or new product to the end user freight prepaid via method to be determined by IMC Networks IMC Networks shall not be liable for any costs of procurement of substitute goods loss of profits or any incidental consequential and or special damages of any kind resulting from a breach of any applicable express or implied warranty breach of any obligation arising from breach of warranty or otherwise with respect to the manufacture and sale of any IMC Networks product whether or not IMC Networks has been advised of the possibility of such loss or damage EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE IMC NETWORKS MAKES NO OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THIS IMC NETWORKS PRODUCT INCLUDING WITHOUT LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED IMC NETWORKS SHALL DISREGARD AND NOT BE BOUND BY ANY REPRESENTATIONS OR WARRANTIES MADE BY ANY OTHER PERSON INCLUDING EMPLOYEES DISTRIBUTORS RESELLERS OR DEALERS OF IMC NETWORKS WHICH ARE INCONSISTENT WITH THE WARRANTY SET FORTH ABOVE ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
4. PURPOSE ARE HEREBY LIMITED TO THE DURATION OF THE EXPRESS WARRANTY STATED ABOVE Every reasonable effort has been made to ensure that IMC Networks product manuals and promotional materials accurately describe IMC Networks product specifications and capabilities at the time of publication However because of ongoing improvements and updating of IMC Networks products IMC Networks cannot guarantee the accuracy of printed materials after the date of publication and disclaims liability for changes errors or omissions Table of Contents FCC Radio Frequency Interference Statement ss iccccswmvicesuadeldasevenbataneumicavaeins ii VATE OIE AAEE sailenresiognd eacancdechesnsbiatand eRe terksetn rasta tents ii About the lE MediaChassis 2 YG caer etcepvecieas acd otaeet caavarrnneiratenteedtian eee 1 Installing the IE Media hassis 2 DC sca cvcisseecsmauntaneastnedaseierer acute nw imei 1 Configuring and Installing MOCUIES oc scescs cstentarssscccvonanarehotedeheosnusscvtebteahesetaneartess 2 DC Power Supply Wiring InstrictOnssccciccsadedsbdladcrtvoannrecsorvindeodis cies cin contgerwanes 3 Rackmount PRECAUTIONS minine en e aA EEEE E 4 DC Power Supply PreCaUtlOns co csexscosivs stextsegeedasdetneta esteeslegs cdacaactestadustevunenearehcelatenn 5 IMC Networks Technical Support ss ssssssssssssssssssssissiesiessssstssisseesetnrenressessrsseesens 6 Specifications sonni iiiar a re a aE E A A e E EE 6 Electrostatic Discharge PIECAUL ONS acs 34sss
5. chassis and the device that will be interconnected and then plug the unit into a reliable filtered power source Configuring and Installing Modules IMC Networks recommends turning the chassis power off before proceeding 1 To install an iMcV module slide the module into the chassis until the module is firmly seated in the backplane Secure the module to the chassis by tightening the captive thumb screw on the iMcV module Attach the network cables between the iMcV module and other devices that will be interconnected Connect the DC power source DC Power Supply Wiring Instructions The following image shows the wiring configuration for a 48 VDC power supply in a negative ground system application For positive ground system applications remove the chassis ground shorting jumper and connect it between the positive terminal and the chassis ground terminal Alternatively the chassis grounding jumper can be eliminated and the chassis ground connected at the power source DC Power Supply Negative ground system configuration default position DP O Terminal Block a E Chassis Ground Jumper Positive L_ Negative Chassis GND ae Incorrect wiring will result in chassis malfunction The IE MediaChassis 2 DC is compliant with Isolated Grounding Plane practices The POSITIVE and NEGATIVE terminals are isolated from chassis ground and must have a ground reference at the power sourcing equipment This equi
6. disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information about proper disposal please contact local authorities waste disposal services or the point of purchase for this equipment Ray LAIN Networks 19772 Pauling Foothill Ranch CA 92610 2611 USA TEL 949 465 3000 FAX 949 465 3020 www imcnetworks com pade in ISO 9001 2000 S Nsa J REGISTERED RoHS Lig 2008 IMC Networks All rights reserved The information in this document is subject to change without notice IMC Networks assumes no responsibility for any errors that may appear in this document IE MediaChassis 2 is a trademark of IMC Networks Other brands or product names may be trademarks and are the property of their respective companies Document Number 50 80105 01 A3 November 2008 If the product s part number begins with an 8 it is compliant with the Restriction of Hazardous Substances RoHS directive
7. ice with a 3mm minimum contact gap in the fixed wiring Install only in Restricted Access Areas dedicated Equipment Rooms Equipment closets or the like in accordance with Articles 110 18 110 26 and 110 27 of the National Electric Code ANSI NFPA 70 Provide a listed circuit breaker suitable for branch circuit protection of the wiring and rated maximum 1A 48 VDC For supply connections use wires suitable for at least 75 C IMC Networks Technical Support Tel 949 465 3000 or 800 624 1070 in the U S and Canada 32 16 550880 Europe Fax 949 465 3020 E Mail techsupport imcnetworks com Web www imcnetworks com Specifications Environmental Operating Temperature 31 F to 176 F 35 C to 80 C Storage Temperature 67 F to 257 F 55 C to 125 C Humidity 5 to 95 non condensing DC Input Specification Input voltage 35 to 75 VDC Input Current 1 5A Output Current Capability 15A 5 VDC Dimensions 2 23 H x 4 75 W x 7 30 D 5 7 cm H x 12 1 cm W x 18 6 cm D Heat Generation 3 BTU hr maximum Fan turns on if the internal temperature exceeds 86 F 30 C Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to your add in modules Always observe the following precautions when installing or handling an add in module or any board assembly 1 Do not remove unit from its protective packaging until you re ready to install it 2 Wear an ESD wr
8. ist grounding strap before handling any module or component If you do not have a wrist strap maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold boards by the edges only do not touch the electronic components or gold connectors 4 After removal always place the boards on a grounded static free surface ESD pad or in a proper ESD bag Do not slide the board over any surface WARNING Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices Safety Certifications UL CUL Listed to Safety of Information Technology Equipment including Electrical Business Equipment CE The products described herein comply with the Council Directive on Electromagnetic Compatibility 2004 108 EC and the Council Directive on Electrical Equipment Designed for use within Certain Voltage Limits 2006 95 EC Certified to Safety of Information Technology Equipment Including Electrical Business Equipment For further details contact IMC Networks LISTED 5M80 ITE E156766 C European Directive 2002 96 EC WEEE requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be
9. ndavhia seiasl eens sda ddan deondev ed deg teayenceniavinse 7 Safety Certificato Seenaa p a a a aa aa 8 About the IE MediaChassis 2 DC The IE MediaChassis 2 DC is a stand alone chassis for use with iMcV modules As an unmanaged chassis the IE MediaChassis 2 DC supports two single wide or one dual wide iMcV module All iMcV modules with the exception of the SNMP management card will function properly in this chassis The IE MediaChassis 2 DC contains an internal Telco compatible DC power supply The iMediaChassis 2 DC includes a temperature triggered fan When the internal temperature of the chassis reaches 86 F 30 C the fan is activated As the temperature increases the fan drive duty cycle adjusts to increase the fan speed You can test the fan operation by depressing the fan test switch on the back of the chassis Fan Test Switch Installing the IE MediaChassis 2 DC Use the IE MediaChassis 2 DC as a table top chassis mount in a Rackmount shelf or mount it to a wall surface brackets are not required 1 Install the IE MediaChassis 2 DC by placing it on a flat surface 2 If mounting on a Rackmount shelf align screw holes and secure with screws 3 4 If mounting the chassis on a wall place two 10 panhead screws not supplied on the wall the distance of the holes on the chassis and then hang the unit on the screws Wall Mount Feature Attach the cables between the
10. pment is designed to permit the connection of the grounded conductor of the DC supply circuit to the grounded conductor at the equipment If this connection is made all of the following conditions must be met 1 This equipment shall be connected directly to the DC supply system grounded electrode conductor or to a bonding jumper from a grounded terminal bar or bus to which the DC supply system grounding electrode conductor is connected 2 This equipment shall be located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the grounded conductor of the same DC supply circuit and the grounding conductor and also the point of grounding of the DC system The DC system shall not be grounded elsewhere The DC supply source shall be located within the same premises as this equipment Switching or disconnecting devices shall not be in the grounded circuit conductor between the DC source and the point of connection of the grounding electrode conductor Rackmount Precautions 1 Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer Reduced Air Flow Installation of the equipment in a rack should be s
11. uch that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Grounding Reliable grounding of rackmounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips DC Power Supply Precautions The following precautions must be observed when installing the chassis model with an internal DC power supply 1 Check nameplate ratings to ensure there is no overloading of supply circuits that could effect over current protection and supply wiring 2 In addition the following must be observed a Connect the equipment to a 35 to 75 VDC power source that is electrically isolated from the alternating current source Route input wiring to terminal block and secure in such a manner that it is protected from damage and stress Do not route wiring past sharp edges or moving parts Incorporate a readily accessible disconnect dev
Download Pdf Manuals
Related Search
Related Contents
User`s Manual (v. 1.5) SPP-R200 - POSGuys.com INSTRUCTIONS MANUAL DIGITAL CLAMP METER ET-3610 自動絞り付きズームレンズ 取扱説明書 iDRAC7 Networking and Improved Remote Access Samsung AD68-04851A User's Manual OPERATOR`S MANUAL MANUEL de L`UTILISATEUR MANUAL del Serie KFU 2- / 4- Manual for 2 Channel 100 Mhz Digital Storage Copyright © All rights reserved.