StarTech.com 3.5in eSATA USB Dual Removable SATA RAID External Hard Drive Enclosure
Contents
1. Driver Installation Windows 2000 XP Server 2003 1 When the Found New Hardware wizard appears on the screen insert the Driver CD into your CD ROM drive If you are prompted to connect to Windows Update please select the No not this time option and click Next 2 Select the option Install Drivers Automatically Recommended and then click the Next button 3 Windows should now start searching for the drivers Once this has completed click the Finish button Windows Vista 1 When the Found New Hardware window appears on the screen click on the Locate and install drivers software recommended option If prompted to search online select the Don t search online option 2 When prompted to insert the disc insert the Driver CD that came with the card into your CD ROM drive and Windows will automati cally proceed to search the CD 3 If a Windows Security dialog window appears click the Install this driver software anyway option to proceed 4 Once the driver is installed click the Close button Verifying Installation From the main desktop right click on My Computer Computer in Vista then select Manage In the new Computer Management window select Device Manager from the left window panel Double click on the SCSI and RAID Controllers or Storage Controllers in Vista option A Silicon Image card should appear under this category SE E SteelVine Manager Ins
2. 5 Plug in the power adapter and press the power button on the front 6 Press the SYS reset button on the unit to make sure it s configured for the proper mode 7 Plug in the USB or eSATA cable and the connect the other end to the computer system StarTech com Mla eSATA Controller Card Installation S352U2RERC only PEXESATA i e 5 AP a Enable external Set J1 J4 jumpers to pins 1 and 2 eSATA port J1 J4 Enable internal Set J1 J4 jumpers to pins 2 and 3 SATA port There are two SATA ports available on the PEXESATA1 card one internal SATA and one external eSATA Please note that only one of them will work at a time Using the jumper settings provided above please designate which port is to be used By default Port 2 internal is set to active 1 Turn your computer off and any peripherals connected to the computer ie Printers external hard drives etc Unplug the power cable from the rear of the power supply on the back of the computer 2 Remove the cover from the computer case 3 Locate an open PCI Express slot and remove the metal cover plate on the rear of the computer case Note that this card will work in PCI Express slots of additional lanes ie x4 x8 or x16 slots 4 Insert the card into the open PCI Express slot and screw the bracket to the rear of the case StarTech com 5 Place the cover back onto the computer 6 Insert the power cable into the socket on the power supply
3. JBOD MODE Ler BIG MODE sere E E S RAID T SAIC EE EE RAID JER RAID JET 250 EE ea SPECIALS sesiis Technical SU DOM Lean stn enanivennnctastmaccnevesdsecan Warranty Information s ranvvnnnvnnuvnnnennnnnnnevnnunnnnnnnuennnennner StarTech com Introduction Packaging Contents e 1x S352U2RER enclosure e 1x eSATA cable e 1x USB A to B cable e 1x Screw Kit e 1 x Power Adapter with power cord e 1 x Instruction Manual e 1 x PCI Express eSATA controller card S852U2RERC only System Requirements e An available USB 2 0 or eSATA port e 1 or 2 SATA Hard Drives e PCI Express enabled computer system S352U2RERC only e Microsoft Windows 2000 XP Server 2003 Vista Mac OS X Linux kernel 2 4 1 0 or later SE E Installation Front View y Power Button Power LED USB Link LED USB Activity LED eSATA Link LED eSATA Activity LED Rear View DC Power In 12V SYS Reset USB Connector eSATA Connector RAID Switch Fan Switch EE E Hardware Installation 1 Remove the drive trays from the enclosure by pressing the release button then pushing down on the arms to eject them and slide the trays out 2 Remove the brace from the trays then secure the hard drive into the trays with the supplied screws 3 Slide the trays back into the enclosure until they are fully seated then close the arms 4 Set the dip switches on the rear of the enclosure for the proper mode you want to use
4. drive comes back online the enclosure will begin the rebuild process immediately to restore data redundancy Although the volume remains available during the rebuild process the volume is susceptible to data loss through damage to the remaining drive until redundancy is restored at the end of the rebuild verification process Host access takes precedence over the rebuild process so if you continue to use the SAFE volume during the rebuild the rebuild process will take longer to complete and the data transfer performance will also be affected NOTE Under Safe Mode if Drive B would start to Rebuild the Link LED of Drive B would start to flash P Dual Bay Disk Port 0 Port 1 Drive A 250GB Equal hard drives Unequal hard drives 12 EE E RAID SAFE33 SAFE33 creates two virtual volumes one SAFE volume and one BIG volume This should be used when you need one volume for critical data and another for non critical It reduces the cost of additional hard drives in operations where non critical data could be lost without severe consequences If one drive fails the SAFE volume is retrievable but the BIG volume is not When you replace the failed drive the SAFE volume is automatically rebuilt to the replacement drive When using a SATA host connection you must have a PM Port Multiplier aware host controller when using SAFE33 If your SATA host adaptor is not PM aware then ONLY the SAFE volume will be de
5. if they are equal or one half of the size of the smaller if they are not equal The size of the BIG volume will be the combination of all remaining Capacities NOTE Under Safe Mode if Drive B would start to Rebuild the Link LED of Drive B would start to flash mm snu Safe 125GB Drive B 750GB LZ Dual Bay Disk Port0 Port I Drive B 750GB Dual Bay Disk PortO Port 1 Equal hard drives Unequal hard drives 14 StarTech com Specifications SATA revision 2 0 Bus Interface USB 2 0 1 x eSATA 7 pin External Connectors 1 x USB type B Power USB Link USB Act eSATA Link eSATA Act Hens HDD A Act HDD A Link HDD B Act HDD B Link Cooling Fan 1 x 50mm Ball Bearing eSATA 3 Gbps Maximum Data Transfer Rate USB 480 Mbps JBOD BIG RAIDO RAID1 Supported RAID Modes SAFE33 SAFE50 Windows 2000 XP Server 2003 Supported Operating Systems Vista Mac OS X Linux kernel 2 4 1 0 or later 15 StarTech com Technical Support StarTech com s lifetime technical support is an integral part of our com mit ment to provide industry leading solutions If you ever need help with your product visit www startech com support and access our com prehensive selection of online tools documentation and downloads Warranty Information This product is backed by a one year warranty In addition StarTech com warrants its products against defects in materials and wor
6. Install the SteelVine Manager from the included CD or download the latest version from the StarTech com website www startech com 2 Launch the SteelVine Manager utility or click on the icon in the system tray Windows only 3 The main window will show you current status of the disks in the enclosure Click on the Configure button to set the RAID mode You will be prompted to enter the password The default is admin 57xx Steel ine Manager Y60ECK9G 3QDO9MRAF V60ECK9G 3QD09MRF Basic Configuration dark To Advanced hode for 57xx SteelVine Manager Hyyyyyyyy 4 Under the Storage Policy section fm set the RAID mode you want and lt click the Apply button Ballad Total GB s Left 1 TELI Cap 232 886 GB Gilicon Image StarTech com RAID Storage Policies NOTE The maximum supported partition size for 32 bit Windows systems is 2 TB Windows cannot detect multiple drives in any RAID mode if the total size exceeds 2TB Hard drives in non RAID mode JBOD are supported up to 2TB GUI MODE factory default GUI mode allows you to use the SteelVine Manager GUI to set the storage policy and other settings as well as monitor the status of the enclosure i e storage capacity and RAID mode of the
7. SS 52UZRER 352U2RERE Instruction Manual Dual SATA External Hard Drive Enclosure 3 5 eSATA USB Dual Removable SATA RAID External d Drive Enclosure INFONE StarTech com Making hard to find easy FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide rea sonable protection against harmful interference in a residential installation This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio com munications However there is no guarantee that interference will not occur in a particu lar installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Use of Trademarks Registered Trademarks and other Protected Names and Symbols This manual may make reference to trademarks registered trademarks and
8. desired hard drive To select this mode ensure that the hard disk drives are installed set DIP switch on the back of the device to the GUI position and turn on the power In this mode no virtual volume s will be created until the storage policy and volume selections are made through the SteelVine Manager GUI To change from GUI mode to some other fixed storage policy thereafter set the DIP switch to the desired position and press the SYS reset button to create the new virtual volume s GUI ONLY N A van 234 JBOD MODE JBOD enables each hard drive to be seen separately or if only a single hard drive is installed When using a SATA host controller JBOD should only be used if the SATA host controller provides Port Multiplier PM support If a host is not PM aware only a single drive is visible drive A No such limitation exists if using a USB host connection JBOD o ERE 9 StarTech com BIG MODE BIG concatenates a series of physical hard drives into a single large volume Hard drives A and B are combined with a storage capacity that is equal to the sum of the two drives There is no data redundancy so if one of the disks fail the data on that disk will be lost Once the hard drives A and B are installed in the enclosure set the DIP switch to BIG mode and press the SYS reset button A single disk drive will now appear with the total capacity of the two separate hard drives BIG y _ NC or MB Q z Bi
9. g 1000GB fc O O Dual Bay Disk ort 0 Port I E Drive A 250GB Equal hard drives Unequal hard drives ae Drive A 250GB 10 StarTech com RAID 0 Fast RAIDO is a combination of two physical hard drives where the data is striped split between them It presents the best data speed as the data is split and written to both disks at the same time but there is no data redundancy If either of the disks fail then all of the data will be lost If two equal capacity hard drives are used the capacity of the hard drives are combined If two unequal capacity hard drives are used the capacity is double that of the smaller hard drive woo Saye T ON 1234 JE eS Dual Bay Disk Dual Bay Disk Port 0 Porti Port 0 Porti Drive B 750GB Striping across disks tt Striping across disks e a Equal hard drives Unequal hard drives 11 StarTech com RAID 1 Safe RAID1 allows the enclosure to automatically copy data to both hard drives It stores all data in duplicate on separate drives to protect against data loss due to drive failure It provides the highest level of data protection for critical data that you cannot afford to lose if a hard drive fails The capacity is equal to the smaller of the two hard drives If one drive fails the SAFE volume is still usable but it is in a vulnerable state because its mirror duplicate hard drive is inaccessible When the offline
10. kmanship for the periods noted following the initial date of purchase During this period the products may be returned for repair or replacement with equivalent products at our discretion The warranty covers parts and labor costs only StarTech com does not war rant its products from defects or damages arising from misuse abuse alteration or normal wear and tear Limitation of Liability In no event shall the liability of StarTech com Ltd and StarTech com USA LLP or their officers directors employees or agents for any dam ages whether direct or indirect special punitive incidental consequen tial or otherwise loss of profits loss of business or any pecuniary loss arising out of or related to the use of the product exceed the actual price paid for the product Some states do not allow the exclusion or limitation of incidental or consequential damages If such laws apply the limita tions or exclusions contained in this statement may not apply to you 16 StarTech com A Making hard to find easy StarTech com has been making hard to find easy since 1985 providing high quality solutions to a diverse IT and A V customer base that spans many channels including government education and industrial facilities to name just a few We offer an unmatched selection of computer parts cables A V products KVM and Serv er Management solutions serving a worldwide market through our locations in the United States Ca
11. nada the United Kingdom and Taiwan Visit www startech com today for complete information about all our products and to access exclusive interactive tools such as the Cable Finder Parts Finder and the KVM Reference Guide
12. other protected names and or symbols of third party companies not related in any way to StarTech com Where they occur these references are for illustrative purposes only and do not represent an endorsement of a product or service by StarTech com or an en dorsement of the product s to which this manual applies by the third party company in question Regardless of any direct acknowledgement elsewhere in the body of this doc ument StarTech com hereby acknowledges that all trademarks registered trademarks service marks and other protected names and or symbols contained in this manual and related documents are the property of their respective holders StarTech com Table of Contents IMTFOGUGCTION saa Packaging GOMGINS scsais vxxnnerencniapiunessanncanneddnrimteesapsnnminieteedieseems System Requirements i c cccsescinccedoncccdcancncdeesaneoeewecnedesucededaneeecee IM STAS ON vante Hardware Installation sassmedndemnmanndsedtdemdddaduhken eSATA Controller Card Installation S852U2RERC only Driver Installation uusueerarnssnsesenhjmubannvmv ti Verifying Ag EL 1 eg EEE EEE EN SteelVine Manager Installation eornrnrnnnnnrrnrennnnnnvennnrnnnnnnnnen ConnguratiO saomssmmsm smeden Mode SSIS C WOU RE EEE EE SteelVine Manager Operation rurannnnonnnnvnnnnnnrnvennennnnennnrnnsnnnnnene RAID Storage Policies nnunannnnnunnnunnnunnnnnnnnunnnunnnunnnunnnuenn GUI MODE factory default Lusumeneiansinimevnenmenisn
13. tallation 1 Insert the included CD and AutoPlay will start vile Leshi nstallaton process Silicon SteelVineManger A 4 Image 2 Select the Install option and proceed through the installation process i 57xx SteelVine ilicon Welcome to the 5 7xx SteelVine Setup Wizard Gi Image The installer will guide you through the steps required to install Revision 5 1 24 of the 57xx SteelVine storage processor volume management software on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law 3 Once complete you should have the tray icon present from which you can launch the SteelVine Manager utility StarTech com Configuration Mode Selection 1 Make sure the enclosure is powered on and not connected to a computer system 2 Set the DIP switches to the appropriate mode SYS Reset DIP Switch RAID 1 SAFE 33 RAID 1 SAFE 50 GUI ONLY ol StarTech com SteelVine Manager Operation To use the SteelVine Manager to configure the enclosure the DIP switches on the enclosure must be configured for GUI mode 1
14. tected and the BIG volume will not be accessible No such limitation exists when using a USB host connection The size of the SAFE volume will be one third of the size of one hard drive if they are equal or one third of the size of the smaller if they are not equal The size of the BIG volume will be the combination of all remaining capacities NOTE Under Safe Mode if Drive B would start to Rebuild the Link LED of Drive B would start to flash PE Dual Bay Disk Dual Bay Disk Port 0 Port 1 Port 0 Port 1 Equal hard drives f Unequal hard drives 13 StarTech com RAID SAFESO SAFE50 creates two virtual volumes one SAFE volume and one BIG volume This should be used when you need one volume for critical data and another for non critical It reduces the cost of additional hard drives in operations where non critical data could be lost without severe consequences If one drive fails the SAFE volume is retrievable but the BIG volume is not When you replace the failed drive the SAFE volume is automatically rebuilt to the replacement drive When using a SATA host connection you must have a PM Port Multiplier aware host adapter when using SAFE50 If your SATA host adaptor is not PM aware then ONLY the SAFE volume will be detected and the BIG volume will not be accessible No such limitation exists when using a USB host connection The size of the SAFE volume will be one half of the size of one hard drive
Download Pdf Manuals
Related Search
Related Contents
7000LA XGA Proyector de Instalación mode d`emploi Proximos Argus Manuel d`utilisation Samsung A/C Ventana DC150 Manual de usuario (E) Gebrauchsanleitung Insel-Dunstabzugshaube voir la plaquette M-Cab 7000253 USB cable catalogo daikin vrv Copyright © All rights reserved.
Failed to retrieve file