Tripp Lite PR40

image

Contents

1. If the product should prove defective in material or workmanship within that period Seller will repair or replace the product in its sole discretion Service under this Warranty can only be obtained by your delivering or shipping the product with all shipping or delivery charges prepaid to Tripp Lite 1111 W 35th Street Chicago IL 60609 Seller will pay return shipping charges Call Tripp Lite Customer Service at 773 869 1234 before sending any equipment back for repair THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ALL IMPLIED WARRANTIES INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSE QUENTIAL DAMAGES Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This Warranty gives you specific legal rights and you may have other rights which vary from jurisdiction to jurisdiction TRIPP LITE 1111 W 35TH STREET CHICAGO IL 60609 WARNING The individual user should take care to determine prior to use whether this device is suitable adequa
2. OWNER S MANUAL PR amp TL Series Precision Regulated DC Power Supplies For use in 120V 60 Hz environments THE POWER PEOPLE M TRIPP LITE D Ag 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 www tripplite com PR 3 PR 3UL PR 4 5 PR 7 PR 10 PR 12 PR 15 PR 20 PR 25 PR 30 PR 40 PR 50 PR 60 TL 11 TLC 11 APPLICATIONS Tripp Lite PR and TL Trimline series DC power supplies convert standard 120 Volt AC VAC 60 Hz power into regulated 13 8 Volt DC VDC power 12V DC output nominal PR and TL series models are ideal for powering a wide range of equipment designed to run on 12V DC power including CB Ham and commercial land mobile radios car stereos amplifiers etc PR and TL series models can also be used as general purpose test bench power sources BATTERY CHARGING NOTE DO NOT use PRand TL series models rated at 12 amps and lower for battery charging If you connect a battery to any of these models with the unit NOT plugged into a live 120 Volt AC outlet or the unit plugged in but turned OFF you may burn out the unit because of reverse current flow You MAY use PR and TL series models rated at 15 amps and higher for battery charging However the battery must be separately fused with a fuse not greater than the value of the unit s nameplate amperage rating Other wise the battery can cause current flow greater than the unit s amperage rating back into the unit under certai
3. R and TL power supplies POSITIVE RED and NEGATIVE BLACK With all equipment turned OFF connect the DC equipment to these terminals making sure to observe the polarity of the wiring Connect Positive to Positive Red to Red and Negative to Negative Black to Black Power Supply Start Up Plug the power supply line cord into a 120V AC 60 Hz outlet Depress the ON OFF switch on the front panel The switch body or indicator light on smaller models will illuminate RED indicating the power supply is functioning properly Turn the connected DC equipment ON only after the power supply has been turned ON CURRENT RATINGS Tripp Lite PR and TL series power supply current ratings are based on the industry standard ICS Intermittent Communications Service limited by heat buildup This translates to a 50 duty cycle of 5 minutes ON 5 minutes OFF Equivalent heat loading would result from 7 minutes ON at 25 load followed by 3 minutes ON at 100 load This cyclical type of loading is similar to the operation of a transceiver Make sure the equipment you are using is properly sized to the capacity of the power supply The maximum current draw of the equipment should not exceed the continuous duty output of the power supply If unsure about your particular application or current output capacities call Tripp Lite Customer Service at 773 869 1234 The PRand TL series features electronic foldback current limiting which protects a
4. UHF ham radios commercial land mobile radios low power linear amps 40 watt transmitters VHF UHF ham radios commercial land mobile radios low power linear amps Same as PR 10 Also designed with footprint to match most popular base station radios Motorola GE EF Johnson and others Same as PR 10 Also designed with integrated enclosure to match most popular base station radios Motorola GE EF Johnson and others 50 watt transmitters VHF UHF ham radios commercial land mobile radios low power linear amps 60 watt transmitters VHF UHF ham radios commercial land mobile radios low power linear amps test bench 75 100 watt transmitters VHF UHF ham radios commercial land mobile radios low power linear amps test bench 125 watt transmitters VHF UHF ham radios commercial land mobile radios medium power linear amps test bench 150 200 watt transmitters VHF UHF ham radios commercial land mobile radios medium power linear amps test bench 225 watt transmitters VHF UHF ham radios commercial land mobile radios medium power linear amps test bench 250 300 watt transmitters VHF UHF ham radios commercial land mobile radios multi piece equipment installations microwave radio applications test bench Intermittent Communications Service 93 1322 9904217 5 99 Printed on Recycied Paper
5. d environment l E Equipment Installation PR models Place your equipment next to your PR model power supply CAUTION DO NOT block the louvers on PR models Allow at least 2 above the top of the PR cabinet for ventilation The compact space saving design of the PR has been made possible by careful placement of the cabinet louvers and design of the external heat sinks to provide adequate internal cooling for long life and reliable performance If you are installing a radio transceiver or other equipment directly on top of PR models you must construct a small raised shelf with at least 2 clearance for the equipment to rest on The PR models louvers are intentionally designed to prevent direct installation of equipment on top of them Equipment Installation TL 11 and TLC 11 Trimline models TL 11 and TLC 11 models are designed specifically to accept the installation of popular name brand radios Simply set the radio on top of the power supply TL 11 models or slide the radio into the space between the top of the power supply and underneath the cabinet cover TLC 11 models TLC 11 models provide an integrated base station appearance while providing protection for the radio Compatible radio models that will fit inside the TLC 11 cover include Motorola Radius and GM 300 GE MVS MTD and TMX GE Monogram Maxon SM 4000 GE Marc and EF Johnson GT ML81 GT ML83 Equipment Connection There are two DC power output terminals on the rear of P
6. gainst short circuits on the DC output The foldback circuitry reduces the output current to less than one amp when shorted When the overload is removed normal current and voltage outputs are automatically restored The PR 7 through PR 60 and the TL models feature time controlled current limiting that delays onset of foldback current limiting for about one second This allows a brief delivery of higher than rated current during this time period allowing operation of incandescent lamp loads up to approximately 65 of the PR and TL s current rating The power supply will also supply repetitive peak currents of up to 160 of the current rating for operation of high power Class B audio amplifiers CAUTION This time controlled current limiting will NOT overcome severe or sustained overloads Some loads may demand peak current more than twice as high as their average current demand This fact should be kept in mind when using the PR and TL series power supplies TROUBLESHOOTING If the power supply stops working check the DC output connections and tighten if loose Check the external fuse If blown replace with the same amperage size only Units with an internal fuse should be checked by a qualified technician 1 YEAR LIMITED WARRANTY Seller warrants this product if used in accordance with all applicable instructions to be free from original defects in material and workmanship for a period of 1 year from the date of initial purchase
7. n circumstances and may burn out the unit FEATURES e Solid State Integrated Circuit provides excellent voltage regulation to within 0 5 V DC output voltage is maintained from 0 to 95 of full load Crowbar Overvoltage Protection prevents overvoltage surges from damaging con nected equipment 15 amp and larger models e High Quality Filtering provides low noise operation excellent for sensitive commu nications receivers 0 1 to 0 15 volts maximum ripple Current Limiting Electronic Foldback automatically limits current and voltage outputs in case of overload time controlled on 7 amp and larger models e Heavy Duty Power Transformer provides complete line isolation Large Heat Sinks and Vented Cabinet provides cool continuous operation and long component life e Compact Attractive Design size and color harmonize with all modern communica tions equipment narrow front profile conserves operating space e Common Ground and Battery Minus Bonded contributes to low noise operation Copyright 1999 Tripp Lite All rights reserved INSTALLATION Power Supply Installation Place your PR or TL power supply in a well ventilated location Note The unit will generate heat as it operates especially if used at or near its current output limits WARNING Hazardous voltages are present inside the unit DO NOT expose the unit to rain or moisture PR and TL models should only be used in a dry indoor protecte
8. te or safe for the use intended Since individual applications are subject to great variation the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application The policy of Tripp Lite is one of continuous improvement Specifications are subject to change without notice SPECIFICATIONS ICS Amps Continuous Model Duty Amps Fusing Chassis Mount Chassis Mount Chassis Mount Chassis Mount Chassis Mount Dimensions H x W x D in Ripple Voltage 1 volt max Weight Ibs 3x 4 1 2x 7 1 2 t volt max 4 1 4x3x 7 1 2 3 1 4 x 3 x 8 1 4 IS volt max 3 3 4 x 6 1 2 x 7 1 2 15 volt max 4 1 2 x 6 3 4 x 7 3 4 15 volt max 4 1 2 x 6 3 4 x 7 3 4 15 volt max 3 1 4 x 7 3 4x9 15 volt max 6 1 4 x 7 3 4 x 9 overall 2 1 8 x 7 5 8 x 9 opening 15 volt max 4 1 2x6x 10 15 volt max 4 1 2x6x 10 6 3 4 x 6 1 4 x 10 1 4 15 volt max 6 3 4 x 6 1 4 x 10 1 4 15 volt max 6 3 4 x 10 1 2 x 11 1 2 15 volt max 6 3 4 x 10 1 2 x 11 1 2 15 volt max 6 3 4 x 10 1 2 x 11 1 2 33 General Applications Guide Home use of CB radios car tape players Home use of single sideband SSB CB radios car tape players tape recorders Home use of single sideband SSB CB radios car tape players tape recorders Home use of single sideband SSB CB radios high power car stereos low power VHF UHF ham radios 30 watt transmitters VHF