Technical manual for Firstbeat Uploader

image

Contents

1. Copyright Firstbeat Technologies Oy version 1 0 0 0 Q cance Figure 3 login screen A valid username and password are to be entered in the login screen Data can only be uploaded after valid credentials are given as they are used to identify the account to which the data is associated with If login is not successful the screen shows information about the cause of the failure Invalid username or You mistyped you username or password password Your account has been closed An administrator has closed your account for Please contact the support some reason Contact the support about this issue Customer account has The customer account to that your account expired Please contact the belongs to has expired or is disabled Contact Support the support about this issue Your account does not have Your account needs to have all necessary personal information personal parameters given before you can use Firstbeat Uploader Login to the web service and complete the personal information After giving valid credentials the process of loading data from the device begins See the following chapters for how to load from certain type of device Copyright Firstbeat Technologies Ltd 1 3 2 Uploading data with Suunto Memory Belt When data is being transferred from Suunto Memory Belt a progress dialog is shown It can be seen in Figure 4 Load from Suunto Memory Belt x HA data is being transtered from
2. Memory Bek This might take few minutes depending on the duration of the measurements to be loaded LITT TT Figure 4 Suunto Memory Belt data loading progress dialog When data loading is complete a dialog for selecting what to upload is shown as seen in Figure 5 Load from Suunto Memory Belt x Select measurements to be loaded from Suunto Memory Belt Memory in use A SOX I T T Ti Load Start time Duration End time 1 2 2008 13 29 34 02 18 36 1 2 2008 15 48 70 8 2 2008 13 37 12 01 55 31 o 2 2008 15 32 45 20 10 2008 15 27 12 00 16 28 20 10 2008 15 43 40 20 10 2008 15 54 08 00 26 11 20 10 2008 16 20 15 29 10 2008 11 17 56 00 24 36 29 10 2008 11 42 32 29 10 2008 12 10 15 00 07 04 29 10 2008 12 17 19 24 10 2008 14 17 55 00 43 08 24 10 2008 15 01 07 24 10 2008 16 45 19 00 08 38 29 10 2008 16 53 57 30 10 2008 12 04 51 00 01 11 30 10 2008 12 06 02 Corrupt Loaded lt s K s sl A 8 s m o o o o o Do not show this again Upload and delete measurements automatically Figure 5 Suunto Memory Belt measurement selection screen In this dialog you can select which measurements you want to upload and which measurements to remove from the device You can also edit start times of the measurements should the device had had incorrect recording time The dialog s table has following columns Column name Description Load Check the box to have the measurement uploaded to the server Start time
3. Start time of the measurement Duration Duration of the measurement Copyright Firstbeat Technologies Ltd End time of the measurement Check the box to have the measurement removed from the device Corrupt The measurement could not be loaded from the device Either because of weak contact between the device and the docking station or the measurement has been corrupted in the device Loaded An X here indicates that this particular measurement has already been uploaded to the server You may face a pair of warning dialogs when you are shown the measurement selection dialog They can be seen in Figure 6 and Figure 7 Load from Suunto Memory Belt x i Measurements shorter than two minutes can not be loaded Do not show this again Figure 6 too short measurement warning Measurements shorter than two minutes are too short to contain any useful data and therefore can not be selected for loading Load from Suunto Memory Belt xX Measurements marked with red have invalid start LD times The start times must be corrected betore they can be loaded Donot show this again Figure 7 measurement start time warning Measurements older than one year or newer than one day are likely because of an incorrect clock time on the device Such measurements can not be uploaded before their start times have been corrected These measurements are also highlighted on the table with red color Editing a mea
4. e Screen resolution at 1024x768 and 16 bit colours e Hard disk drive free space 50MB e Adobe Acrobat Reader 5 0 or later e Compatible measurement devices Suunto Memory Belt Suunto Smart Belt Omron Pedometer HJ 720 1 3 Using Firstbeat Uploader 1 3 1 Logging in When Firstbeat Uploader is started it shows icon in the notification area of Windows taskbar as seen in Figure 1 18 F il a l i k l Figure 1 Firstbeat Uploader in notification area The programs functions are accessed from the main menu by right clicking the icon The menu can be seen in Figure 2 Copyright Firstbeat Technologies Ltd Search devices Suunto Memory Belt Config Tool Options About Close program ht i The main menu has following functions Search devices Initiates upload operation for currently connected devices Suunto Memory Bemory Belt Opens the configuration tool for Suunto Config Tool Memory Belt Options Opens the Options dialog About Shows About dialog with version information Close program Closes the program Figure 2 the main menu When you select Search devices from the main menu or double click the icon the program searches for supported devices When a supported device is detected you are asked for your credentials to begin the upload process The login screen is shown in Figure 3 Copyright Firstbeat Technologies Ltd Rr RSTBEAT TTR ITEN gt TNP A ps Firstbeat Uplioadel
5. Firstbeat Uploader Technical Manual version 1 0 0 0 Table of contents CEC HINIC AL PUN arias ceca reader cc ceseeac en ecedcadecusnaedewcevacceeaucecescdenecscedacstuecuscececeeasacere 1 1 OPM WARE FEATURES eccacencceteccecaunncuceaecaccescnsnessseucecsacuensiencwcssieseesewucsausaceecdusaceesenceeesseacece 3 1 2 MINIMUM SYSTEM REQUIREMENTS wscscccccccecccccecceuceuneuneuneuneeneeneuneuaeuneuaeuaeuaeuaeuneuaeuneuaeueuneuns 3 1 3 USING FIRSTBEAT UPLOADER ccrisnrisaano a a a a a 3 1 3 1 E a A 3 1 3 2 Uploading data with Suunto Memory Belt cccccceececeeeeseeeeeeeeeeaeeeeesaeeaeseeaesaeseeaesaeeaegess 6 1 3 3 Uploading data with Omron Pedometer HJ 720 cccccecceececeeeeeeeeeeeeeeeeaeeaeeeeaeeaeeeeaesaeeengess 8 1 3 4 DONS Gl NOG a xsce var cease seq rccawecancanaetatzansseeccaussiancantanaseancushaegssueauiaeratauice tauianespsascuueravci 10 1 3 5 Suunto Memory Belt Config TOOl cccccccsecceceeeeeeeeeeseeeeeeeeeeseeaeeaeeeeaeeaesaeaeeaesaeseeaesaegaeas 12 Copyright Firstbeat Technologies Ltd 1 TECHNICAL MANUAL 1 1 Software features Firstbeat Uploader is software for PC computers developed and owned by Firstbeat Technologies Ltd It used for reading information related to bodily functions from external devices The information is uploaded to a server 1 2 Minimum system requirements e Compatible with Windows 2000 Windows XP and Windows Vista e Windows ME and 98 are not tested e 512MB of RAM e 1GHz CPU
6. lly performed without user interaction 1 3 5 Suunto Memory Belt Config Tool The Suunto Memory Belt Config Tool offers means to configure the Suunto Smart Belt Following options can be configured e Synchronizing belt internal clock e Turning belt tones on off e Turning radio transmission on off turning the radio transmission off saves the battery e Memory full warning limit percentage warning is given when free memory is below this limit e Number of free logs low warning limit warning is given when number of free logs is below this limit Copyright Firstbeat Technologies Ltd e Identifier string for the belt Suunto Memory Belt Config Tool Default User Synchronize the belt s internal clock by pressing button Sync Smart Belt Time Save the new configuration by pressing button Save or close the tool with button Cancel Copyright Firstbeat Technologies Ltd 13
7. rded during the day Calories Amount of energy in kcal consumed Having selected what to upload press the OK button You will see a message in the notification area once the upload is complete Copyright Firstbeat Technologies Ltd 10 1 3 4 Options dialog Options dialog is used to configure the functionality of the program The general tab contains options related to overall functionality it can be seen in Figure 12 x General Memory Belt Pedometer Select language Finnish f English Firstbeat files root tolde Folder C Firstbeat Files Browse Server address Jhttps trainer firstbeat fi w eb raner Restore default OF Cancel Apply Figure 12 gereral tab of options The tab offers following options Language Changes the language of the user interface across the program Firstbeat files folder Changes the location of the folder containing measurement backup files Server address Changes the address of the server to which the program connects The Memory Belt tab contains options related to Suunto Memory Belt as shown in Figure 13 Copyright Firstbeat Technologies Ltd General Memory Belt Pedometer x W Synchronize Memon Belt clack automatically W Create backups of loaded measurements M Show measurement start tine warning Show too short measurement warning When measurements can be merge f Ask what to do Me
8. rge automatically C Do nothing Measurement merging time limit 1 00 00 hh mm OF Cancel Apply Figure 13 Memory Belt tab of options The tab offers following options fopton erp Load and delete measurements automatically Belt Synchronize Memory clock automatically Create backups of loaded measurements Show measurement start time warning Show too short measurement warning Measurement merging Measurement merging time Determines maximum period of time between Toggles if measurement loading and deleting is performed without user interaction Toggles if Memory Belt s time is synced every time it is connected Toggles if backup files are created of all measurements uploaded to the server They are placed under the Firstbeat Files folder Toggles if warning of measurement start times is shown Toggles if warning of too short measurements is shown Controls what is done when measurements matching the merging interval are detected Copyright Firstbeat Technologies Ltd 11 measurements to be applicable for merging The pedometer tab contains options related to Omron pedometer as shown in x General Memory Belt Pedometer Load and clear pedometer contents automatically Cancel Apply Figure 14 Pedometer tab of options The tab offers following options Load and clear pedometer Toggles if step data loading and deleting is contents automatica
9. surement s start time is done by double clicking the start time row of the measurement this opens a date and time editor in the table as seen in Figure 8 Copyright Firstbeat Technologies Ltd Load from Suunto Memory Belt Select measurements to be loaded from Suunto Pemo Start time Duration 26 10 2008 15 54 08 00 26 11 29 10 2008 11 17 00 24 36 Figure 8 measurement start time editor The checkbox in the screen can be used to have the whole screen skipped next time When this is selected all measurements are automatically uploaded to the server and all logs are removed from the device without user interaction Having selected what to upload press the OK button This may open a question dialog about measurement merging Some measurements may have been fragmented into several shorter ones Measurement merging merges such measurements into a whole one The question dialog can be seen in Figure 9 Load from Suunto Memory Belt X One of more measurements are closer than 1 00 00 P vr do you want to merge them Remember my answer and do not show this again Figure 9 measurement merging question The checkbox in the dialog can be used to have the merging done automatically in the future or not done at all Finally a progress dialog for the data uploading is shown as seen in Figure 10 Firstbeat Uploader x Measurements are being uploaded to the server This might take few minutes depending on
10. the duration of the measurements and the quality of the network connection Figure 10 measurement upload progress dialog After the upload has been successfully completed the selected measurements are removed from the device and the program returns to the initial state 1 3 3 Uploading data with Omron Pedometer HJ 720 After data transwith Omron device is completed a selection dialog is shown as seen in Figure 11 Copyright Firstbeat Technologies Ltd Load from Omron pedometer x Select data to be loaded from pedometer Aerobic steps Calories 2 17 3 2009 16 3 2009 15 3 2009 14 3 2009 13 3 2009 Clear pedometer contents Do not show this again Load and dear pedometer contents automatically Ez Select all ok Close Figure 11 Omron device loading screen In this dialog you can select which day s steps you want to upload If you want to clear the pedometer s memory select the option Clear pedometer contents You can select not to see this dialog in the future and have all days step data uploaded automatically followed by clearing of the pedometer s memory This is select by checking the lower checkbox The dialog s table has following columns Column name Description Load Check the box to have the day s step data uploaded to the server Date Date of the day Aerobic steps Amount of aerobic steps recorded during the day Steps Amount of steps reco

Download Pdf Manuals

image

Related Search

Related Contents

AMD CS5535 User's Manual  webConnect User Manual  取扱説明書  Home Decorators Collection 4772810410 Instructions / Assembly  Development Manual - Tinovimba G. Motsi  Installationsanleitung  Raclette - Grill - Fondue Gourmet - Set Raclette-Grill  (応用編)p.27「2台以上使用する」  Manuel d`installation, d`utilisation et d`entretien de la famille Sun  STATION MÉTÉO PROFESSIONNELLE METEOTIME  