Broan-NuTone MHS120L Combination Light Fan Exhaust Fan

image

Contents

1. b after being energized by cycling the power switch It can be adjusted from 5 to 60 minutes factory set at approx 20 minutes To adjust the TIMER 1 Disconnect power at service entrance and remove light lens 2 Through the grille locate the screwdriver slot marked TIMER 3 Using a small flat blade screwdriver carefully rotate the TIMER adjustment to desired setting from 5 to 60 minutes 4 Check operation by cycling the power switch as instructed under MANUAL ON WITH TIMED OFF Fan or by turning on a humidity source until the fan turns on 5 Turn humidity source off and time the unit 6 Repeat above steps if necessary TIMER ADJUSTMENT Motion Sensor The SENSAIRE fan light night light has a TIMER that controls the length of time that the light remains ON after motion has stopped It can be adjusted from 5 to 60 minutes factory set at approx 20 minutes To adjust the TIMER Disconnect power at service entrance Remove grille Locate the hole marked TIMER on the side of the motion control assembly Using a small flat blade screwdriver carefully rotate the TIMER adjustment to desired setting from 5 to 60 minutes Replace grille Turn on power and wait approximately 1 minute before activating unit After unit turns ON stay outside of its viewing area and time the unit 7 Repeat above steps if necessary AON o au VIEWING AREA ADJUSTMENT MOTION SENSOR The viewin
2. canales para soporte de la caja NOTA La caja se puede montar directamente a la viga usando los agujeros y las ranuras que se incluyen Use los soportes para apoyo adicional FIG 4 INSTALACION DEL VENTILADOR 1 Elija la posici n del ventilador Para asegurar el mayor rendimiento use el m nimo n mero posible de conductos y el m nimo de codos 2 Coloque la unidad entre las vigas y extienda los soportes de montaje Sit e los soportes de manera que el extremo inferior de la caja est a nivel con el cielo raso acabado Marque la parte superior de la ranura en los cuatro soportes de montaje FIG 5 3 Saque la unidad por unos momentos y clave los clavos parcialmente en las vigas en las cuatro posiciones marcadas FIG 6 4 Cuelgue la unidad en los clavos Use las gu as de medida en las esquinas de la caja para comprobar si la unidad est a nivel con el cielo raso acabado Clave los clavos completamente Si existen centros de viga anchos se puede usar un tornillo autoenroscable 8 x 3 8 para unir los soportes extendidos y crear una superficie de montaje r gida Para asegurar un montaje sin ruidos doble los canales de los soportes fuertemente alrededor de los soportes de montaje FIG 7 5 Conecte el conector del amortiguador conducto a la caja Compruebe que las leng etas en el conector cierran en las ranuras de la caja y que el amortiguador cierra por gravedad FIG 8 6 Instale conducto redondo de 4 pulg y extie
3. 5 a 60 minutos 4 Verifique el funcionamiento reciclando el interruptor de potencia como se indico en ENCENDIDO MANUAL ON CON TEMPORIZADOR APAGADO OFF VENTILADOR o prendiendo un aparato que produzca humedad hasta que se prenda el ventilador 5 Apague el aparato y gradue el tiempo en la unidad 6 Repita los pasos anteriores si es necesario COMO GRADUAR EL TEMPORIZADOR SENSOR DE MOVIMIENTO El Ventilador con luces diurna y nocturna SENSAIRE tiene un temporizador TIMER que controla el tiempo que la luz permanece prendida ON despu s de haber cesado el movimiento Puede ajustarse de 5 a 60 minutos el reglaje de f brica es aproximadamente 20 minutos Como Graduar el Temporizador TIMER 1 Desconecte la corriente en el servicio de entrada 2 Quite la rejilla 3 Ubique el orificio marcado TIMER en el costado del conjunto controlador de movimiento 4 Con un destornillador peque o de hoja plana haga girar con cuidado el reglaje del temporizador al punto deseado de 5 a 60 minutos 5 Reponga la rejilla 6 Conecte la fuerza el ctrica y espere aproximadamente un minuto antes de activar la unidad Luego que la unidad se ha prendido ON permanezca fuera del alcance de la visi n de la unidad y gradue el tiempo 7 Repita los pasos anteriores si es necesario AJUSTE DEL REA DE VISI N SENSOR DE MOVIMIENTO El rea de visi n por debajo de la unidad es en forma de cono con un di metro aproximado de 3 4 m al ni
4. dampness control the SENSITIV ITY may need to be increased toward maximum MAX If the control is re sponding too often to changing environmental conditions movement toward less MIN SENSITIVITY may be required To adjust the SENSITIVITY 1 Disconnect power at service entrance and remove light lens 2 Through the grille locate the screwdriver slot marked SENSITIVITY 3 Using a small flat blade screwdriver carefully rotate the SENSITIVITY ad justment toward MAX or MIN 4 Turn on power and check operation by turning on the shower or other humid ity source until the fan turns on 5 Repeat above steps if necessary SUJECCION DE LA REJILLA 1 Enchufe el cableado de sensor de movimiento en conjunto de control de movimiento 2 Enchufe el cableado de la luz luz nocturna en conjunto de control de humidad 3 Fije el conjunto de la rejilla con dos tornillos de rosca phillips que se incluyen NO LOS SOBREAPRIETE Esto puede resultar en da os a la rejilla FIG 11 4 Saque el lente empujando suavemente de un extremo FIG 12 5 Instale las bombillas Luz primaria 100 vatios Max Luz nocturna 7 vatios tipo C7 USO Y MANTENIMIENTO ADVERTENCIA ANTES DE LIMPIAR AJUSTAR O SERVIR LA UNIDAD CORTE LA CORRIENTE EL CTRICA EN EL PANEL DE SERVICIO BLOQUEE EL PANEL DE SERVICIO PARA EVITAR QUE LA FUERZA EL CTRICA SE RECONECTE ACCIDENTALMENTE OPERACI N del TERMOSTATO y SENSOR Un termostato es p
5. mounting brackets Position brackets such that bottom edge of housing will be flush with finished ceiling Mark the top of keyhole slot on all four mounting brack ets FIG 5 Remove unit temporarily and pound nails partially into joists at all four marked locations FIG 6 Hang unit from nails Use measuring guides on cor ners of housing to check if unit will be flush with fin ished ceiling Pound nails tight For wide joist cen ters A 8 x 3 8 self tapping screw can be used to join extended brackets together and create a rigid mount To ensure a noise free mount crimp the bracket channels tightly around mounting brackets FIG 7 Snap the damper duct connector onto housing Make sure that tabs on the connector lock in hous ing slots and that gravity closes damper FIG 8 Install 4 round duct and extend duct to outside through a roof or wall cap Check damper to make sure that it opens freely Tape all duct connections to make them secure and air tight FIG 2 CAPTIVE SCREW TORNILLO CAUTIVO PREPARACION DEL VENTILADOR 1 Desune el tornillo cautivo que sujeta el conjunto del ventilador en su sitio Saque el conjunto de su caja FIG 2 2 Elija la parte lateral o la parte superior de la caja para hacer las conexiones el ctricas Saque el disco removible doblando ste para adelante y para atr s y as romper las leng etas FIG 3 3 Deslice los soportes ajustables de montaje en los
6. y no puede desarmarse para limpiarlo Funcionar m s eficientemente si se limpia la lente de cuando en cuando as 1 Desconecte la corriente el ctrica en el servicio de entrada 2 Emplee un trapo seco para despolvar o la aspiradora para limpiar las lentes y rejilla NO EMPLEE TELAS ABRASIVAS ALMOHADILLAS de VIRUTAS de ACERO o POLVOS para RESTREGAR 3 NO EMPLEE rociadoras solventes o agua en o cerca del sensor COMO LIMPIAR EL CONJUNTO VENTILADOR 1 Desconecte la corriente el ctrica en el servicio de entrada 2 Quite la rejilla y desconecte las luces los sensores y el ventilador Desune el tornillo cautivo y baje el conjunto ventilador de la caja Con la aspiradora limpie con cuidado el ventilador el motor y el interior de la caja LAS PARTES MET LICAS y ELECTRICAS NUNCA DEBEN SUMERGIRSE en AGUA 3 El motor lleva lubricaci n permanente y no se necesita lubricaci n adicional SERVICE PARTS PIEZAS DE SERVICIO MODEL MHS120L MODELO MHS120L Housing 97009275 Caja Venturi Plate Includes Key No 9 97014513 Placa Venturi incluye c digo 9 Blower 97011270 Soplador Motor 97012137 Motor Motor Cup 95000963 Cubierta del motor Motor Mounting Rubber 2 Req 99100412 Goma de montaje del motor se necesitan 2 Blower Wheel 99110735 Disco del soplador Screw 8 18 x 375 Black 99150491 Tornillo negro 8 18 x 0 375 9 Req se necesitan 9 Screw 8 18 x 625 Zinc 99150571 Tornillo de zinc 8 18 x 0 625 Wire Cover H
7. HED ON ACCIDENTALLY THERMOSTAT amp SENSOR OPERATION A thermostat is built into the SENSAIRE fan light night light to assure proper sen sor operation The fan may turn ON if it was OFF if the light is ON for an ex tended period of time The unit uses a sophisticated humidity sensor that responds to a rapid to mod erate user adjustable increases in humidity or b humidity above a user adjust able set point 50 100 Relative Humidity The humidity sensor may occa sionally turn the fan ON when environmental conditions change If the fan con tinuously responds to changing environmental conditions SENSITIVITY adjust ment may be required MANUAL ON WITH TIMED OFF Fan The SENSAIRE fan light night light has an additional operation feature For odor or vapor control the fan can be energized by cycling the power switch Once the fan has been energized in this manner it will remain on for the user adjustable TIMER period approx 5 to 60 minutes This period is factory set for approxi mately 20 minutes To manually energize the fan 1 If fan power switch is already ON proceed to Step 2 otherwise turn power switch ON for more than 1 second 2 Turn fan power switch OFF for less than 1 second 3 Turn fan power switch back ON and fan will turn ON SENSITIVITY ADJUSTMENT Humidity Sensor The SENSITIVITY has been factory set for most shower applications However if the fan is in a tub area or is being used for
8. Instrucciones para el tendido de conductos El ventilador funcionar de la forma m s eficiente cuando se sit e donde se necesite el m nimo n mero de conductos y el menor n mero posible de codos 2 Planificaci n del cableado el ctrico Planifique suministrar a la unidad el voltaje de l nea y el cable de potencia apropiados El cable de potencia debe llevarse primero a la caja de interruptores y luego a la unidad Vea Figs 9 y 10 No controle esta unidad con un control de velocidad Esto resultar en da os a la unidad del sensor Siga los siguientes pasos b sicos cuando instale esta unidad e Clave la caja a las vigas o soportes e Fije los conductos e Conecte el cable de potencia Instale el conjunto del ventilador e Fije la rejilla a la caja PREPARE THE FAN 1 2 Disengage the captive screw holding the fan assem bly in place Lift assembly from housing FIG 2 Choose either the top or side of housing for electri cal connection Remove the knockout by bending it back and forth to break tabs FIG 3 Slide adjustable mounting brackets into bracket channels on housing NOTE Housing may be mounted directly to joist using holes and slots pro vided Use brackets for additional support FIG 4 INSTALL THE FAN 1 Choose the location for your fan For best possible performance use the shortest possible duct run and a minimum number of elbows Position unit between joists and extend
9. RO YA QUE ES CONMUTADO USE UN LAPIZ COLORANTE CABLEADO ELECTRICO DEL VENTILADOR 1 Los dos m todos m s comunes de conectar este ventilador se muestran en las Figuras 9 y 10 Siga el que haya elegido cuando plane la instalaci n NOTA Normalmente se necesita una caja extra profunda de acople sencillo o doble Compruebe los requisitos de c digo 2 Saque la cubierta de la caja de cables y conecte la unidad siguiendo el diagrama Lleve el cable el ctrico de la forma m s directa posible a la unidad No permita que el cable toque los lados o la parte superior de la unidad despu s que la instalaci n se haya completado Empuje todos los cables hacia una esquina de la unidad Coloque de nuevo la cubierta de la caja de cables 3 Coloque de nuevo el conjunto del ventilador y a segure ste con el tornillo cautivo 4 Enchufe los conectores en sus enchufes ATTACH GRILLE 1 Plug motion sensor wiring into motion control as sembly 2 Plug light night light wiring into humidity control as sembly 3 Attach grille assembly with 2 phillips head screws provided DO NOT OVERTIGHTEN Damage to grille may result FIG 11 4 Remove lens by gently pulling on one edge FIG 12 5 Install bulbs Primary 100W Max Night Light 7 W Type C7 USE AND CARE WARNING BEFORE CLEANING SERVICING OR ADJUSTING THE UNIT SWITCH POWER OFF AT SERVICE PANEL LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITC
10. SENSAIRE SERIES MODEL MHS120L MOTION HUMIDITY SENSING FAN LIGHT NIGHT LIGHT READ AND SAVE THESE INSTRUCTIONS SERIE SENSAIRE MODELO MHS120L VENTILADOR LUZ LUZ NOCTURNA CON SENSORES DE MOVIMIENTO Y HUMEDAD LEA Y CONSERVE ESTAS INSTRUCCIONES WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOW ING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warn ing device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all ap plicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and ex hausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the Na tional Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB and the local code autho
11. SOR DE MOVIMIENTO LIGHT LUZ NIGHT LIGHT ON OFF LUZ NOCTURNA ENCENDIDO APAGADO FAN AUTO OFF VENTILADOR AUTOMATICO APAGADO BLK NEG HUMIDITY SENSOR SENSOR DE HUMIDIDAD BLK NEG WHT BLC SWITCH BOX CAJA DE INTERRUPTORES UNIT UNIDAD CODE REQUIRES BOTH ENDS OF THIS WIRE S INSULATION TO BE COLORED BLACK SINCE IT IS SWITCHED USE A FELT TIPPED MARKER EL CODIGO REQUIERE QUE AMBOS EXTREMOS DEL AISLAMIENTO DE ESTE CABLE SEAN DE COLOR NEGRO YA QUE ES CONMUTADO USE UN LAPIZ COLORANTE FIG 10 WIRING OPTION 2 Fan can be turn ON OFF or set to operate automatically OPCI N DE CONEXI N 2 El ventilador se puede encender apagar o poner en funci n autom ticamente MODEL MODELO 77DV 77DW P77DV P77DW 4 FUNCTION CONTROL PURCHASE SEPARATELY CONTROL DE 4 FUNCIONES COMPRESE POR SEPARADO HUMIDITY SENSOR SENSOR DE FAN MOVIMIENTO _ fO vENTILADOR VENTILADOR RED ROJ ENCENDIDO AUTOMATICO BLk NEG NIGHT LIGHT ON OFF l LUZ NOCTURNA ENCENDIDO APAGADO ORG NRJ AZL MOTION SENSOR SENSOR DE HUMIDIDAD LIGHT AUTO OFF LUZ l AUTOMATICO APAGADO LIGHT LUZ 120vac BLK NEG LINE IN Linea DE WHT BLC ENTRADA 120 VCA SWITCH Bi UNIT UNIDAD CODE REQUIRES BOTH ENDS OF THIS WIRE S INSULATION TO BE COLORED BLACK SINCE IT IS SWITCHED USE A FELT TIPPED MARKER EL CODIGO REQUIERE QUE AMBOS EXTREMOS DEL AISLAMIENTO DE ESTE CABLE SEAN DE COLOR NEG
12. arness Assembly 97011912 Cubierta de cable Conjunto de cables Includes Key No 24 preconfigurados incluye c digo 24 Ground Clip 99390015 Clip de tierra Wire Clip 2 Req 99420643 Clip de cable se necesitan 2 Sheet Metal Nut 8 18 4 Req 93260454 Tuerca de hoja de metal 8 18 se necesitan 4 Damper Duct Connector 97014185 Conector amortiguador conducto Mounting Bracket 4 Req 98003036 Soporte de montaje se necesitan 4 Grille Nut 2 Req 99420631 Tuerca de la rejilla se necesitan 2 Light Lens 99110736 Lente de la luz Screw 6 20 x 2 875 2 Req 99150542 Tornillo 6 20 x 2 875 se necesitan 2 Lamp Socket Assembly 97012135 Conjunto del cubo de la bombilla Rivet 125 Dia x 212 99230342 Remache 0 125 de di metro x 0 212 Grille Assembly Includes Key 97011909 Conjunto de la rejilla Nos 19 8 20 incluye c digos 19 y 20 Humidity Control Assembly 97011835 Conjunto de control de humedad Motion Control Assembly 97011164 Conjunto de control de movimiento Screw 8 18 x 375 Zinc 99150570 Tornillo 8 18 x 0 375 zinc Lens Mask 99078495 M scara del lente Standard Hardware May be purchased locally Material est ndar Puede ser adquirido localmente Not shown No se muestra Order service parts by PART NO NOT by KEY NO Encargue piezas de servicio por NO PIEZ NO por NO CODIGO BROAN NUTONE ONE YEAR LIMITED WARRANTY Broan NuTone warrants to the original con sumer purchaser of its products that such produ
13. arte integrante del conjunto SENSAIRE de ventilador con luces diurna y nocturna para asegurar el funcionamiento correcto del sensor El ventilador puede prenderse ON si estuvo apagado OFF si la luz queda prendida ON por largo tiempo La unidad lleva un sensor de humedad de gran refinamiento t cnico que re sponde a a de r pidos a moderados aumentos de la humedad regulables por el usuario o b humedad que excede el punto fijado por el usuario 50 100 Humedad Relativa El sensor de humedad puede en ocasiones activar el ventilador ON cuando ocurren cambios medioambientales Si el ventilador re sponde continuamente a condiciones medioambientales cambiantes puede ser necesario ajustar la sensibilidad SENSITIVITY ENCENDIDO MANUAL ON CON TEMPORIZADOR APAGADO OFF VENTILADOR El ventilador con luces diurna y nocturna SENSAIRE tiene una caracter stica de funcionamiento adicional Para controlar el olor y el vapor el ventilador puede activarse apagando y encendiendo el interruptor Una vez ue el ventilador est energizado de esta manera A prendido ON por el tiempo que el usuario haya marcado en el temporizador TIMER aproximadamente de 5 a 60 minutos El reglaje de f brica es aproximadamente 20 minutos Para energizar el ventilador manualmente 1 Si el interruptor de potencia ya est encendido ON proceda al paso 2 de otra manera conecte el interruptor ON por m s de 1 segundo 2 Desconecte el interruptor de p
14. at service entrance 2 Use a dry dustcloth or lightly vacuum to clean lens and grille DO NOT USE ABRASIVE CLOTH STEEL WOOL PADS OR SCOURING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor FAN ASSEMBLY CLEANING 1 Disconnect power at service entrance 2 Remove grille and unplug the light night light sensors and fan Disengage cap tive screw and lower fan assembly from housing Gently vacuum fan motor and interior of housing METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER 3 Motor is permanently lubricated No additional lubrication is necessary USO Y MANTENIMIENTO Continuo COMO GRADUAR EL TEMPORIZADOR SENSOR DE HUMEDAD El ventilador con luces diurna y nocturna SENSAIRE lleva un temporizador TIMER que controla el tiempo que el ventilador queda prendido ON a despu s que el sensor ha dejado de detectar un aumento de la humedad y el nivel de humedad es menor que el punto fijado por el usuario o b despu s de reciclar el interruptor de potencia Se puede ajustarlo de 5 a 60 minutos el reglaje de f brica es aproximadamente 20 minutos Para graduar el temporizador TIMER 1 Desconecte la fuerza en el servicio de entrada y quite los cristales de las luces 2 A trav s de la rejilla ubique la ranura para destornillador marcada TIMER 3 Con un destornillador peque o de hoja plana haga girar con cuidado el reglaje del temporizador TIMER hasta el punto deseado de
15. cts will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MER CHANTABILITY OR FITNESS FOR A PAR TICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a nor mal maintenance and service or b any prod ucts or parts which have been subject to mis use negligence accident improper mainte nance or repair other than by Broan NuTone faulty installation or installation contrary to rec ommended installation instructions The duration of an implied warranty is limited to the one year period as specified for the ex press warranty Some states do not allow limi tation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO RE PAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CON SEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential dam ages
16. d minimum number of elbows will be needed 2 Plan the wiring Plan to supply the unit with proper line voltage and ap propriate power cable Power cable should be routed to the switch box first and then to the unit See Figs 9 8 10 Do nat control this unit with a speed control Damage to the sensor unit will result Follow these basic steps when installing this unit Nail housing to joists e Attach ductwork e Connect power cable e Install fan assembly e Fasten grille to housing FIG 1 POWER CABLE CEILING CABLE DE JOIST POTENCIA VIGA DEL MOUNTING BRACKET HOUSING SOPORTE DE MONTAJE mi CAJA DRYWALL PARED DE YESO GRILLE REJILLA PLANIFICACION DE LA INSTALACION 1 Elija la posici n de instalaci n La posici n de su ventilador SENSAIRE es muy importante Siga estas instrucciones para un mejor funcionamiento Instrucciones para el sensor de humedad a El ventilador SENSAIRE usa un sensor de humedad que reacciona a aumentos de humedad y a humedad alta El sensor de humedad puede activar el ventilador ON en ocasiones cuando hay combios medioambientales Si el ventilador responde continuamente a condiciones medio ambientales combiantes se puede necesitar ajustar la sensibilidad SENSITIVITY b Coloque la unidad se necesita un circuito protector desviador a tierra en caso de corto circuito GFCI a 1 52 m o m s 5 pies o m s de la ducha c Coloque la unidad alejada de fuent
17. de servicio y asegure el panel de servicio para evitar que se encienda accidentalmente Cuando el dispositivo para desconectar el servicio el ctrico no puede ser cerrado con alg n tipo de traba sujete fuertemente al panel de servicio una etiqueta de advertencia prominente 3 El trabajo de instalaci n y el cableado el ctrico deben de llevarse a cabo por personal calificado de acuerdo con todos los c digos y las normas aplicables incluyendo los c digos y normas de construcci n contra incendios 4 Se requiere una cantidad de aire suficiente para la combusti n de gases por la chimenea del equipo que quema combustible para evitar retrogresi n de la llama Siga las especificaciones y est ndares de seguridad para equipos de calefacci n del fabricante tales como los publicados por la Asociaci n Nacional de Protecci n Contra Incendios NFPA por sus siglas en ingl s y la Sociedad Americana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado ASHRAB y los c digos de las autoridades locales 5 Cuando corte o taladre en una pared o cielo raso no da e los cables el ctricos u otras instalaciones no visibles 6 Los ventiladores con conductos deben siempre extraer hacia el exterior 7 Esta unidad puede ser usada sobre una ba era o ducha cuando est instalada con un circuito protector desviador a tierra en caso de corto circuito GFCI solamente instalaci n del cielo raso 8 Si esta unidad va a ser insta
18. enciona abajo o al tel fono 1 800 637 1453 b dar el n mero del modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar servicio cubierto por la garant a usted debe de presentar evidencia de la fecha original de compra Broan NuTone LLC 926 West State Street Hartford WI 53027 EE UU 1 800 637 1453 99042976F
19. es de calor o frio que puedan afectar los niveles de humedad d Coloque la unidad solamente en cielos rasos planos de hasta 3 66 m 12 pies de alto para una detecci n apropiada e La unidad debe ser instalada en el cielo raso para detectar humedad de manera apropiada f No coloque la unidad cerca de una ventana La unidad puede responder al nivel de humedad exterior Instrucciones para el sensor de movimiento a La unidad responder al movimiento de personas y animales Despu s que la unidad deja de detectar movimiento continuar ENCENDIDA durante unos 20 minutos aproximadamente La duraci n del tiempo en que la unidad permanece encendida se puede regular de 5 hasta 60 minutos aproximadamente b El rea de detecci n del sensor tiene forma de cono con un di metro de aproximadamente 3 35 m 11 pies al nivel del suelo en una habitaci n de 2 44 m 8 pies El rea de detecci n se puede reducir para que calce en su instalaci n c Haga referencia a la secci n de USO Y MANTENIMIENTO de la p ginas 5 y 6 para detalles sobre c mo ajustar el tiempo y el rea de detecci n d Sit e la unidad alejada de pasillos y otras reas de alto tr fico para evitar arranques indeseados e Coloque la unidad solamente en cielo rasos planos de hasta 3 66 m 12 pies de alto para una detecci n apropiada f Sit e la unidad en flujo normal de tr fico La unidad no detectar movimiento en un rea remota de la habitaci n
20. g area below the unit is cone shaped with a diameter of approximately 11 ft at floor level in an 8 ft high room The viewing area can be reduced by applying a mask to the sensor lens Two washer shaped masks are provided The larger diameter mask will reduce the viewing area to approximately 7 ft the smaller diameter mask used with the larger one will reduce the viewing area to a diameter of approximately 3 ft To prevent the unit from sensing from a certain direction adjacent hallway for example cut and use a portion of the mask To mask the lens 1 Remove the mask from its backing and apply it to the lens with light pressure 2 Turn unit ON and wait approximately 1 minute before checking operation 3 If necessary cut out a portion of the mask with a pair of scissors and re apply to lens HUMIDITY SENSOR CLEANING The humidity sensor is behind the grille The sensor will operate most reliably when cleaned occasionally as follows 1 Disconnect power at service entrance 2 Remove the grille Use a dry dustcloth of lightly vacuum to clean sensor and grille DO NOT USE ABRASIVE CLOTH STEEL WOOL PADS OR SCOUR ING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor MOTION SENSOR CLEANING The motion sensor is permanently mounted in the grille and cannot be disas sembled for cleaning The sensor will operate most reliably when the lens is cleaned occasionally as follows 1 Disconnect power
21. he fan continu ously responds to changing environmental conditions SENSITIVITY adjustment may be required Locate unit above GFCI protected circuit required or within 5 feet of shower head Locate unit away from heating or cooling sources which can affect humidity levels Locate unit only on flat ceilings up to 12 feet high for proper sensing Unit must be installed in ceiling to properly sense moisture Do not locate near window Unit may respond to the outdoor humidity level Motion sensing guidelines a e f Unit will respond to movement by people and animals After the unit stops sensing movement it will stay ON for an additional 20 minutes approx The length of ON time can be adjusted from approx 5 to 60 min utes The sensor s viewing area is cone shaped with a di ameter of approximately 11 ft at floor level in an 8 ft high room The viewing area can be reduced to ac commodate your installation Refer to USE AND CARE section on pages 5 amp 6 for details about adjusting the time and the viewing area Locate unit away from hallways and other high traffic areas to prevent unwanted start ups Locate unit only on flat ceilings up to 12 feet high for proper sensing Locate unit in normal traffic flow Unit will not sense motion in remote areas of room Ducting guidelines The fan will operate most efficiently when located where the shortest possible duct run an
22. lada sobre una ba era o ducha debe ser marcada como apropiada para esta aplicaci n 9 Nunca coloque un interruptor donde pueda ser alcanzado desde una ba era o ducha 10 No use esta unidad con aparatos de estado s lido de control de velocidad 11 Esta unidad debe ser conectada a tierra PRECAUCION 1 Solamente para uso de ventilaci n general No se Use para extraer materiales o vapores peligrosos o explosivos Este producto est dise ado solamente para instalarse en los techos planos NO MONTE ESTE PRODUCTO EN LAPARED 3 Para evitar da os al cojinete del motor y o impuldores ruidosos o desequilibrados mantenga la fuente de potencia lejos de roc os de pared de yeso de polvo de construcci n etc 4 Lea la etiqueta de especificaciones del producto para m s informaci n y requisitos N INSTALLER Leave This Manual With The Homeowner HOMEOWNER Use and Care Information on Pages 5 amp 6 INSTALADOR Deje este manual con el due o de casa DUENO DE CASA Informaci n del uso y mantenimientoen la p ginas 5 y 6 PLAN THE INSTALLATION 1 Choose the installation location The location of your SENSAIRE fan is very important Follow these guidelines for best operation Humidity sensing guidelines a e f The SENSAIRE fan uses a humidity sensor that re sponds to both increases in humidity and to high hu midity The humidity sensor may turn the fan ON when environmental conditions change If t
23. nda el conducto hacia el exterior a trav s de la cubierta del cielo raso o la pared compruebe que el amortiguador abre con libertad Cubra con cinta adhesiva todas las conexiones de conductos para hacerlas seguras y herm ticas WIRE THE FAN 1 The two most common methods of wiring this fan are shown in Fig ures 9 amp 10 Follow the one you chose when you planned the in stallation NOTE An extra deep single ganged and or double ganged box is usually required Check code requirements 2 Remove wiring cover Run elec trical cable as directly as possible to unit Do not allow cable to touch sides or top of unit after in stallation is complete Push all wiring into corner of unit Replace wiring cover 3 Replace fan assembly and se cure with captive screw 4 Plug wiring connectors into their receptacles WIRING OPTION 1 Allows fan to operate in automatic mode or manual on with timed off mode for odor control by cycling ON OFF switch Allows fan circuit to be turned OFF when desired OPCION DE CONEXION 1 Permite que el ventilador funcione autom tica o manualmente con el temporizador apagado para controlar los olores reciclando el interruptor ON OFF Permite apagar OFF el circuito del ventilador si se desea MODEL MODELO 66V 66W P66V P66W 3 FUNCTION CONTROL PURCHASE SEPARATELY CONTROL DE 3 FUNCIONES COMPRESE POR SEPARADO r LIGHT AUTO OFF LUZ AUTOMATICO APAGAGO MOTION SENSOR SEN
24. ntenimiento y servicio normales o b cualquier producto o piezas que hayan sido utilizadas de forma err nea negligente que hayan tenido un accidente o que hayan sido reparadas o mantenidas inapropiadamente por otras compa as que no sean Broan NuTone instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un per odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant a impl cita por lo que la limitaci n antes mencionada puede no aplicarse a usted LA OBLIGACION DE BROAN NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DE BROAN NUTONE DEBERA SER EL UNICO Y EXCLUSIVO RECURSO LE GAL DEL COMPRADOR BAJO ESTA GARANTIA BROAN NUTONE NO SERA RESPONSABLE POR DA OS INCIDENTALES CONSIGUIENTES O POR DA OS ESPECIALES QUE SURJAN A RAIZ DEL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consiguientes por lo que la limitaci n antes mencionada puede no aplicarse a usted Esta garant a le proporciona derechos legales espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para calificar en la garant a de servicio usted debe a notificar a Broan NuTone al domicilio que se m
25. otencia del ventilador OFF por menos de 1 segundo 3 Vuelva a conectar el interruptor ON para que se prenda el ventilador REGULACI N DE LA SENSIBILIDAD SENSOR DE HUMEDAD La sensibilidad SENSITIVITY viene ajustada de f brica para la mayor parte de las aplicaciones de ducha Sin embargo si el ventilador est ubicado sobre una ba era o se est usando para control de humedad la sensibilidad tal vez se deba aumentar hacia el m ximo MAX Si el control est respondiendo con mucha frecuencia a condiciones medioambientales cambiantes se puede requerir un ajuste hacia menos MIN sensibilidad SENSITIVITY Para graduar la sensibilidad SENSITIVITY 1 Desconecte la corriente el ctrica en el servicio de entrada y quite las lentes de las luces 2 Por la rejilla ubique la ranura para destornillador marcada SENSITIVITY 3 Con un destornillador peque o de hoja plana haga girar con cuidado el reglaje SENSITIVITY hacia MAX M ximo o MIN M nimo 4 Reconecte la corriente y verifique el funcionamiento abriendo la ducha u otro aparato que produzca humedad hasta que el ventilador se prenda 5 Repita los pasos anteriores si es necesario USE AND CARE Continued TIMER ADJUSTMENT Humidity Sensor The SENSAIRE fan light night light has a TIMER that controls the length of time that the fan remains ON a after the sensor has stopped sensing a rise in humidity and the humidity level is below the user adjustable set point or
26. rities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to outdoors 7 This unit may be used over a tub or shower enclo sure when installed in a GFCI protected branch cir cuit ceiling installation only 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application 9 Never place a switch where it can be reached from a tub or shower 10 Do not use this unit with any solid state speed con trol device 11 This unit must be grounded CAUTION 1 For general ventilating use only Do not use to ex haust hazardous or explosive materials and vapors 2 This product is designed for installation in flat ceil ings only DO NOT MOUNT THIS PRODUCT IN A WALL 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construc tion dust etc off power unit 4 Please read specification label on product for fur ther information and requirements ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA ELECTRICA O LESIONES PERSONALES CUMPLA CON LOS SIGUIENTES PUNTOS 1 Solamente use esta unidad de la manera propuesta por el fabricante Si tiene alguna pregunta p ngase en contacto con el fabricante en la direcci n o tel fono anotados en la garant a 2 Antes de limpiar o de poner en servicio la unidad apague el interruptor en el panel
27. so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan Nutone at the address stated be low or telephone 1 800 637 1453 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting war ranty service you must present evidence of the original purchase date Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 GARANTIA BROAN NUTONE LIMITADA POR UN A O Broan NuTone garantiza al comprador consumidor original de sus productos que tales productos estar n libres de defectos en materiales o en mano de obra por un per odo de un a o a partir de la fecha original de compra NO EXISTEN OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICU LAR Durante el per odo de un a o y a su propio criterio Broan NuTone reparar o reemplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso ESTA GARANTIA NO SE APLICA A TUBOS Y ARRANCADORES DE LAMPARAS FLUORESCENTES Esta garant a no cubre a ma
28. vel del piso en un cuarto con una altura de 2 4 m El rea de visi n puede reducirse poniendo mascarilla o recuadro en las lentes del sensor Se sumimistran dos mascarillas en forma de arandelas la de mayor di metro reducir la visi n a aproximadamente 2 m la de menor di metro en combinaci n con la grande reducir la visi n a un di metro de aproximadamente 91 cm Para impedir que la unidad detecte im genes que vienen de cierta direcci n entrada o vest bulo contiguo por ejemplo corte y use una secci n de la mascarilla Para cubrir las lentes 1 Quite el respaldo de la mascarilla y apl quela a las lentes con ligera presi n 2 Prenda la unidad ON y espere aproximadamente un minuto antes de verificar la operaci n 3 Si fuera necesario corte una secci n de la mascarilla con tijeras y vuelva a aplicarla a la lente COMO LIMPIAR EL SENSOR DE LA HUMEDAD El sensor de la humedad se halla detr s de la rejilla El sensor funcionar m s eficientemente cuando se lo limpie de cuando en cuando as 1 Desconecte la corriente el ctrica en el servicio de entrada 2 Quite la rejilla Emplee un trapo seco para despolvar o la aspiradora para limpiear las sensor y rejilla NO EMPLEE TELAS ABRASIVAS ALMOHADILLAS de VIRUTAS de ACERO o POLVOS para RESTREGAR 3 NO EMPLEE rociadoras solventes o agua en o cerca del sensor COMO LIMPIAR EL SENSOR DE MOVIMIENTO El sensor de movimiento est permanentemente instalado en la rejilla