Broan-NuTone Best By Broan ILB6 Inline Blower Options: 625 CFM Kitchen Hood
Contents
1. BY BROAN IN LINE BLOWER MODEL ILB6 Page 1 READ AND SAVE THESE INSTRUCTIONS A FOR DOMESTIC COOKING ONLY A WARNING A TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR IN JURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service discon necting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a quali fied person s in accordance with all applicable codes and stan dards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Con ditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities Ducted
2. TRANSITION 42 X 18 au 10 po 11 4 x 47 au 25 4 cm circulaire CONDUIT CIRCULAI DE 10 po 25 4 cm LN VAZZZZTBEZEF Raccordement de conduit typique un ventilateur converti en d charge droit angle MOD LE ILB6 BY BROAN Page 12 UTILISATION ET ENTRETIEN Pour nettoyer la soufflerie Retirer la panneau d access A x d brancher la soufflerie du boitier retirer les crous de fixation de Suivre les instructions de c blage fournies avec le hotte etrespecter 5 soufflerie et retirer d licatement la soufflerie du boitier Utiliser tous les codes locaux et provinciaux en vigueur de m me que le 5 accessoire d aspirateur appropri ou retirer la grille et nettoyer Code national de l lectricit l aide d un chiffon doux et de savon ou de d tergent doux pour AVERTISSEMENT Pour diminuer les risques de nettoyer la zone de d charge de la soufflerie et la roue NE PAS d charge lectrique d brancher la source LAISSER D EAU S INFILTRER DANS LE MOTEUR S assurer que d alimentation avant toute op ration d entretien la soufflerie est compl tement s che avant de la r installer Le moteur est lubrifi en permanence Ne pas lubrifier ou d monter le moteur PIECES DE RECHANGE L cENDE W DER F DESCRIPTION 97014744 Bo tier 97014728 Support 2 oblig 98009449 Registre 2 oblig 97014822 Ensemble de clapet de registre 2 oblig 99150415 Vis 8 18 x 1 4 18 oblig 98005512 Plaqu
3. TYPICAL INSTALLATION MOUNTING New Frame Construction 10 ROUND DUCT AV X 18 TO 10 ROUND TRANSITION Mounting brackets factory shipped in position for 2 ceiling material CEILING JOIST 24 centers l 10 ROUND Blower factory shipped DUCT in horizontal discharge position 4 X 18 TO 10 ROUND MOM TRANSITION SCREW Factory shipped unit installed in new construction MOUNTING Existing Frame Construction 42 X 1877 TO 10 2 X 4 FRAMING ROUND TRANSITION wide side down 4V X 18 TO 10 ROUND TRANSITION 10 ROUND DUCT MOUNTING SCREW MOUNTING BRACKETS Attached to opposite sides of housing amp upside down so housing is flush with finished ceiling CEILING JOIST 24 centers shown Blower factory shipped in straight through discharge position IMPORTANT Remove shipping tape from damper Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and air tight MODEL ILB6 Page 2 TYPICAL INSTALLATION MOUNTING USING HANGER KIT included EXTENSION SPRING 10 ROUND DUCT INTAKE HANGER KIT CHAIN HANGER KIT EYE BOLT 7 HANGER KIT NUT amp WASHER MOUNTING BRACKET GRILLE NUT Install into square holes in housing 10 ROUND DUCT OUTLET ACCESS i PANEL SCREW Blower factory shipped in straight throu
4. ce et c d crire la nature de tout d faut dans le produit ou la pi ce Au temps de demander le service sous garantie vous devez pr senter une preuve de la date d achat original Aux E U comuniquez avec Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 Au Canada comuniquez avec Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario L5T 1H9 905 670 2500 99043701B
5. 4 X 18 a 10 po VIGUETA DEL TECHO se muestran centros de 61 cm 24 po CONDUCTO REDONDO DE 25 4 cm 10 po TRANSICI N 11 44 X 47 a254 cm 4 X 18 2 a 10 po Ventilador enviado de f brica en posici n de descarga horizontal TORNILLO DE MONTAJE Unidad enviada de f brica instalada en una estructura nueva MONTAJE Estructura existente TRANSICI N 11 4 X 47 a 25 4 cm ESTRUCTURA DE 5 08 x 10 2 cm 2 x 4 po 434 X 1812 a 10 po con el lado del cableado hacia abajo TRANSICI N 11 4 X 47 a 25 4 cm 412 X 18 a 10 po CONDUCTO REDONDO DE 25 4 cm 10 po ADMISION CONDUCTO REDONDO DE 25 4 cm 10 po SALIDA TORNILLO DE MONTAJE ABRAZADERAS DE MONTAJE conectadas a los lad opuestos del alojamien hacia abajo para que el alojamiento quede a nivel del cielo raso terminado VIGUETA DEL TECHO se muestran centros de 24 61 cm Ventilador enviado de f brica en posici n de descarga derecho por del ventilador NOTA Aseg rese de quitar la cinta que fija la pesta a del regula dor durante la transportaci n y de que esta pesta a abra y cierre libremente dentro del conducto Utilice cinta de conductos para asegurar y hermetizar las conexiones de los conductos MODELO ILB6 P gina 6 INSTALACI N T PICA MONTAJE EL USAR KIT DE SUSPENDER incluido TORNILLO Y ARANDELA DE KIT DE SUSPENDER RESORTE EXTENCI N CONDUCTO REDONDO DE 25 4 cm 10 po CADENA DE
6. 42 X 18 au 10 po 11 4 x 47 au 25 4 cm circulaire FIXATION Appareil install dans un b timent en cours de construction MONTAGE construction termin e TRANSITION 42 X 18 au 10 po 11 4 x 47 au 25 4 cm circulaire CHARPENTE 2x4 c t large en bas TRANSITION 42 X 18 au 10 po 11 4 x 47 au 25 4 cm circulaire CONDUIT CIRCULAIRE DE 10 po 25 4 cm SORTIE CONDUIT CIRCULAIRE DE 10 po 25 4 cm ADMISSION SUPPORTS fix s aux autres c t s du boitier et l envers pour que le boitier soit au ras du plafond fini SOLIVE DE PLAFOND 24 po 61 cm centre Soufflerie pr assembl e en position de d charge dans ligne REMARQUE Veiller retirer le ruban adh sif d exp dition du volet du registre et s assurer que ce dernier s ouvre et se ferme librement l int rieur du conduit Utiliser du ruban adh sif pour assurer et tancher les raccords des conduits MOD LE ILB6 Page 10 INSTALLATION TYPIQUE MONTAGE EN UTILISANT LE KIT DE CINTRE inclus VIS ET RONDELLE DE LE LE KIT POUR ACCROCHER id RESSORT DE PROLONGATION CONDUIT CIRCULAIRE DE 10 po 25 4 cm ADMISSION CHAINE DE LE KIT POUR ACCROCHER BOULON D OEIL DE LE KIT POUR TRANSITION CIRCULAIRE d DE8 t A VIS ET vov ij RONDELLE DE o LE KIT POUR eee ACCROCHER SUPPORTS ECROU DE Fi TT PANNEAU i D ACCESS Installez sur les trous carr s CONDUIT dans le logement CIRCULAIRE
7. 97014744 Housing Assembly 97014728 Mounting Bracket 2 req 98009449 Duct Connector 2 req 97014822 Damper Flap Assembly 2 req 99150415 Screw 8 18 x 18 req 98005512 Wiring Plate 99150471 Ground Screw 10 32 x 2 2 req 98005513 Wire Box Cover 99400035 Strain Relief Bushing 97006039 Wire Harness 99260477 Nut 4 20 12 req 97014745 Scroll Assembly 2 req 99020273 Blower Wheel 2 req 98009399 Inlet Ring 2 req 99080488 Motor 97014794 Motor Mounting Bracket 99100497 Rubber Isolator 4 req 99160380 Screw 10 24 x 7 8 4 req 99250399 Washer 4 req 99260306 Nut Hex 10 24 4 req 99250254 Washer 4 req 93260456 Nut Hex Flange 3 8 16 98009461 Scroll Mounting Channel 97016793 Blower Assembly Complete Includes Key Nos 5 amp 11 23 98009464 Access Panel 99420470 Access Panel Nut 4 req 99150472 Access Panel Mounting Screw 4 req 99150591 Screw 10 16 x 7 8 4 req 97016791 Hanger Kit S423 Transition 4 5 x 18 to 10 Round 97014597 Rough In Kit Order replacement parts by PART NO not by KEY NO Standard hardware may be purchased locally BLOWER Not shown assembled ASSEMBLY 2477 26 WARRANTY BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year fro
8. DE 10 po 25 4 cm SORTIE l VIS DE PANNEAU PANNEAU D ACCESS D ACCESS Soufflerie pr assembl e en position de d charge dans ligne INSTALLATION DES CONDUITS d charge de soufflerie dans ligne CONDUIT CIRCULAIRE DE 10 po 25 4 cm TRANSITION 42 X 18 au 10 po 11 4 x 47 au 25 4 cm circulaire CONDUIT CIRCULAIRE DE 10 po 25 4 cm CHAPEAU CIRCULAIRE DE 10 po 25 4 cm Deux mani res de raccorder les conduits un appareil pr mont BY BROAN CABLAGE DESSUS ARRIERE DU BOITIER FIL DE TERRE A PLAQUE DE CABLAGE PLAQUE DE CABLAGE ENTREE 120 VCA du le hotte Le ventilateur peut tre branch depuis l ext rieur du bo tier Utiliser des connecteurs homologu s UL pour les branchements conform ment aux codes locaux en vigueur OPTIONS DE MONTAGE Des crous six pans 4 20 fixent les supports au bo tier Desserrer et resserrer ou retirer et replacer les crous si n cessaire selon la position d sir e pour le support a 54 6 cm gt I 54 6 cm gt Supports retourn s et fix s de part et d autre de la sortie du bo tier Sortie perpendiculaire aux solives B timent d j construit Supports en position pr assembl e Sortie parall le aux solives B timent en cours de construction t J0 of M am 31 1 cm gt l Supports fix s de part et d autre de la sortie du bo tier Sortie perpendiculair
9. KIT DE SUSPENDER TRANSICI N 11 4 X 47 a254 cm 4 X 182 a 10 po OJO DE KIT DE SUSPENDER TORNILLO DE S 227 j TUERCA Y ARANDELA DE KIT DE SUSPENDER I TUERCA DE PANEL DE ACCESO Instale en los agujeros pequefios en la CONDUCTO cubierta REDONDO DE 25 4 cm 10 po TRANSICION 11 4 X 47 a 25 4 cm 4 X 182 a 10 po PANEL DE ACCESO 1 TORNILLO DE E PANEL DE ACCESO Ventilador enviado de f brica en posici n de descarga derecho por del ventilador COLOCACI N DE CONDUCTOS descarga derecha por del ventilador VENTILACI N EN EL ALERO CONDUCTO REDONDO DE 25 4 cm 10 po CONDUCTO REDONDO DE 25 4 cm 10 po TRANSICI N 11 44 X 47 a254 cm 42 X 18 a 10 po Cd Pg A TAPA DEL CODO REDONDO TECHO DE 25 4 cm 10 po Dos formas de conectar los conductos a una unidad enviada de f brica BY BROAN CABLEADO PARTE SUPERIOR POSTERIOR DEL ALOJAMIENTO TIERRAA LA PLACA DE CONEXIONES PLACA DE CONEXONES L NEA DE ENTRADA DE 120 VCA de la campana BLANCO A BLANCO El ventilador se puede conectar desde el exterior del alojamiento Use conectores aprobados por UL en la conexi n en cumplimien to con los c digos locales OPCIONES DE MONTAJE Las tuercas hexagonales de 4 x 20 aseguran las abrazaderas de montaje en el alojamiento Afloje y vuelva a apretar o quite y reem place las tuercas seg n sea necesario para colocar las abrazaderas d
10. LORSQU UN FEU SE DECLENCHE SUR LA SURFACE DE CUISSON SUIVEZ CES DIRECTIVES 1 ETOUFFEZ LES FLAMMES avec un couvercle herm tique une t le bis cuits ou un plateau en m tal puis teignez la cuisini re PRENEZ GARDE AUX BRULURES Si vous ne parvenez pas teindre imm diatement les flammes EVACUEZ LES LIEUX ET CONTACTEZ VOTRE POSTE LOCAL DE LUTTE CONTRE LES INCENDIES 2 NE VOUS EMPAREZ JAMAIS D UN PLAT QUI S EST ENFLAMME Vous risqueriez de vous br ler AVERTISSEMENT A 8 N UTILISEZ JAMAIS D EAU incluant les linges vaisselles ou serviettes mouill s car cela peut provoquer une violente explosion de vapeur 4 Utilisez un extincteur SEULEMENT si A Il s agit d un extincteur de classe ABC et que vous savez comment vous en servir B Il s agit d un petit feu qui ne se propage pas ailleurs que sur la cuisini re C Vous avez appel votre poste local de lutte contre les incendies D Vous pouvez combattre le feu tout en ayant acc s une sortie Bas sur Kitchen Fire Safety Tips dit par NFPA ATTENTION 1 Pour ventilation g n rale seulement Ne l utilisez pas pour vacuer les vapeurs ou mat riaux dangereux ou que peuvent exploser 2 Pour viter d endommager les coussinets du moteur et des turbines bruyantes et ou mal quilibr es assurez que l unit motrice est exempte de poussi re provenant des murs en pierres s ches et la construction 3 Si le ventilateur est install dans un endroit no
11. temperatura o cuando cocine alimentos que se puedan incendiar 3 Limpie con frecuencia los ventiladores No debe permitir que la grasa se acumule en el ventilador ni en el filtro 4 Utilice un sart n de tama o adecuado Siempre utilice el utensilio adecuado al tama o del elemento de superficie PARA REDUCIR EL RIESGO DE LESION A PERSONAS RESULTADO DE UN INCENDIO DEBIDO A GRASA ACUMULADA EN LAS HORNILLAS PROCURE LO SIGUIENTE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal despu s apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUE Y AVISE ALOS BOMBEROS 2 NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS Usted se podr quemar 3 NO UTILICE AGUA incluyendo toallas de cocina mojadas puede resultar una explosi n de vapor violenta ADVERTENCIA A 4 Utilice un extinguidor SOLAMENTE si A Usted sabe que tiene un extinguidor de clas ABC y lo sabe utilizar B El incendio es peque o y contenido dentro del rea donde se inici C Los bomberos han sido avisados D Usted puede combatir el incendio con una salida a su espalda Basado en las recomendaciones para Seguridad en la Cocina publicadas por la NFPA de los EEUU CUIDADO 1 Para uso de ventilaci n general solamente No lo use para extraer materiales 0 vapores peligrosos o explosivos 2 Para evitar da o a los cojinetes del motor y h lices ruidosas y o desequilibradas mantenga
12. A DEL VENTILADOR CONECTOR DEL CONDUCTO CONECTOR DEL CONDUCTO lt q Cambie la posici n del conector del ventilador y del conducto para una descarga Conector del ventilador y del conducto en posici n de descarga derecha por del ventilador ajuste de f brica Cambie la posici n del conector del ventilador y del conducto para una descarga ngulo recto COLOCACI N DE DUCTOS Descarga ngulo recto del ventilador CONDUCTO REDONDO DE 25 4 cm 10 po TRANSICI N 11 4 X 47 a254 cm 4 X 182 a 10 po CL dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd 2 gt lt N N Lo NA ZZ Conexi n t pica de los conductos al ventilador cambiado a descarga ngulo recto MODELO ILB6 BY BROAN Pagina 8 USO Y CUIDADO Para limpiar el conjunto del ventilador Quite el panel de acceso a desconecte el ventilador del alojamiento quite las tuercas de Siga las instrucciones para las conexiones el ctricas que vienen montaje del ventilador y cuidadosamente saque el ventilador del empacadas con el campana y observe todos los c digos locales alojamiento Use el aditamento apropiado de la aspiradora o un y estatales y el C digo El ctrico Nacional pa o suave y jab n o detergente suave para limpiar el rea de ADVERTENCIA Para reducir el riesgo de sufrir una Jescarga y la rueda del ventilador NO PERMITA QUE ENTRE descarga el ctrica antes de dar servicio al ventilador AGUA AL MOTO
13. R Aseg rese de que el conjunto del ventilador descon ctelo del suministro el ctrico est completamente seco antes de volverlo a instalar El motor est permanentemente lubricado No lubrique ni desmonte el motor PIEZAS DE SERVICIO CLAVE PIEZA DESCRIPCI N 97014744 Conjunto del alojamiento 97014728 Abrazaderas de montaje se req 2 98009449 Conector del conducto se req 2 97014822 Conjunto de la solapa de compuerta de tiro se req 2 99150415 Tornillos 8 18 x 14 se req 18 98005512 Placa de conexiones 99150471 Tornillos de conexi n a tierra 10 32 x t se req 2 98005513 Cubierta de la caja de conexiones 99400035 Buje de alivio de tensi n 97006039 Arn s de alambre 99260477 Tuercas 4 20 12 req 97014745 Conjunto del caracol 2 req 99020273 Rueda del ventilador 98009399 Anillo de entrada 2 req 99080488 Motor 97014794 Abrazadera montaje de motor 99100497 Aislador de caucho se req 4 99160380 Tornillos 10 24 x 7 8 se req 4 99250399 Arandelas se req 4 99260306 Tuercas hex 10 24 se req 4 99250254 Arandelas se req 4 93260456 Tuerca hex pesta a 3 8 16 98009461 Ranura montaje de caracol 97016793 Conjunto del ventilador completo Incluye clave N s 5 y 11 23 98009464 Panel de acceso 99420470 Tuercas de panel de acceso se req 4 99150472 Tornillos de montaje de pane de acceso se req 4 99150591 Tornill
14. R R DUIRE LE RISQUE D INCENDIE DE CHOC LECTRIQUE O DE BLESSURES PERSONNELLES OBSERVEZ CE QUI SUIT 1 Utilisez cette unit seulement de la fa on pr vue par le fabricant Pour d autres renseignements contactez le fabricant l adresse ou au num ro de t l phone qui se trouve dans la garantie 2 Avant d effectuer une r paration ou un entretien sur cet appareil coupez le courant au tableau d alimentation et verrouillez celui ci pour emp cher que la tension soitremise accidentellement Lorsque le verrouillage de la d connexion n est pas possible mettez bien en vue un signal d avertissement telle qu une tiquette sur le panneau d alimentation 3 L installation et la pose des fils lectriques doivent tre effectu es par une ou des personnes qualifi es conform ment tous les codes et normes applicables incluant les normes de construction en rapport aux incendies 4 ll faut suffisamment d air pour une combustion appropri e et l chappement des gaz par le tuyau de la chemin e de l quipement br lant du combustible pour pr venir un contre courant Suivez les instructions du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et des autorit s du code local 5 Lors de la coupe ou du per age dans un mur ou un plafond prenez soin de ne pas e
15. Y if A You know you have a Class ABC extinguisher and you already know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION 1 For general ventilating use only Do not use to exhaust hazard ous or explosive materials and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 3 If ventilator is installed in an unconditioned space such as an attic Surround the ventilator with thermal insulation to minimize possible condensation 4 Please read specification label on product for further informa tion and requirements TABLE OF CONTENTS This manual is divided into sections as follows TYPICAL INSTALLATION This section shows a common installation Mounting New Frame Construction Mounting Existing Frame Construction Mounting Using Hanger Kit included Ducting straight through blower discharge Wiring MOUNTING OPTIONS WIRING OPTIONS Wiring Plate Position e DUCTING OPTIONS Blower Discharge Positions Ducting vertical blower discharge USE AND CARE SERVICE PARTS WARRANTY Installer Leave this manual with the homeowner Homeowner Use and Care information on page 4 Let BY BROAN
16. ate d achat original IL N Y A PAS D AUTRES GARANTIES EXPRIMEES OU IMPLICITES INCLUANT MAIS NON PAS LIMITE AUX GARANTIES IMPLICITES POUR FIN DE COMMERCIALISATION ET DE CONVENANCE DANS UN BUT PARTICULIER Pendant cette p riode d un an Broan son choix r parera ou remplacera gratuitement tout produit ou pi ce qui s av re d fectueux sous utilisation et service normaux CETTE GARANTIE NE COUVRE PAS LES DEMARREURS DE LAMPES FLUORESCENTES ET LES TUBES Cette garantie ne couvre pas a l entretien et le service normal ou b tout produit ou pi ce endommag par suite de mauvais usage n gligence accident entretien inappropri ou r paration autre que par Broan mauvais installation ou installation contraire au mode d installation recommand La dur e de toute garantie implicite est limit e une p riode d un an tel que sp cifi pour la garantie exprim e L ENGAGEMENT DE BROAN DE R PARER OU DE REMPLACER AU CHOIX DE BROAN SERA LA SEULE OBLIGATION EXCLUSIVE SOUS CETTE GARANTIE BROAN NE SE TIENDRA PAS RESPONSABLE DES DOMMAGES DIRECTS INDIRECTS OU SP CIAUX SURVENANT CAUSE DE OU EN RAPPORT A L UTILISATION OU LA PERFORMANCE DE SES PRODUITS Cette garantie vous donne des droits l gaux sp cifiques et il se peut que vous ayez d autres droits Cette garantie annule toutes les garanties pr c dentes Pour le service sous garantie vous devez a aviser Broan l adresse ci dessous b donner le num ro du mod le et l identification de la pi
17. e aux solives B timent en cours de construction 8 8 a 6 4 WE y Em 0 0 LE 54 6 cm Supports retourn s pour donner environ po de d gagement suppl mentaire Sortie perpendiculaire aux solives B timent en cours de construction 24 1 a 273a ay ger 54 6 cm gt Supports fix s sur le dessus de part et d autre du bo tier Sortie parall le aux solives B timent en cours de construction ou d j construit l 54 6 cm gt Supports retourn s et fix s sur le dessus de part et d autre du boitier Sortie parall le aux solives B timent en cours de construction ou d j construit MOD LE ILB6 Page 11 OPTIONS DE CABLAGE POSITION DE LA PLAQUE DE CABLAGE BRANCHEMENT DU CABLE D ALIMENTATION LA VERTICALE BRANCHEMENT DU di CABLE D ALIMENTATION A L HORIZONTALE La plaque de c blage se fixe sur le c t ou sur le dessus du bo tier OPTIONS D INSTALLATION DES CONDUITS POSITIONS DE LA DECHARGE DE LA SOUFFLERIE RACCORD DE CONDUIT RACCORD DE CONDUIT Modifier la position du raccord de soufflerie et de conduit pour une d charge droit angle Raccord de soufflerie et de conduit en position de d charge dans ligne pr assembl e Raccord de soufflerie et de conduit en position de d charge droit angle INSTALLATION DES CONDUITS d charge de soufflerie droit angle 3 AN CHAPEAU DE TOIT
18. e de cablage 99150471 Vis de terre 10 32 x 1 2 2 oblig 98005513 Couvercle de la bo te de c blage 99400035 R ducteur de tension 97006039 Harnais fils 99260477 Ecrou 4 20 12 oblig 97014745 Volute 2 oblig 99020273 Roue de soufflerie 98009399 Bague d arriv e 2 oblig 99080488 Moteur 97014794 Support de montage de moteur 99100497 Isolant de caoutchouc 4 oblig 99160380 Vis 10 24 x 7 8 4 oblig 99250399 Rondelle 4 oblig 99260306 Ecrou Hex 10 24 4 oblig 99250254 Rondelle 4 oblig 93260456 Ecrou Hex Flange 3 8 16 98009461 Barre de montage de volute 97016793 Soufflerie ensemble inclut n l gende 5 et 11 23 98009464 Panneau d access 99420470 Ecrou de panneau de access 4 oblig 99150472 Vis de fixation de panneau de access 4 oblig 99150591 Vis 10 16 x 7 8 4 oblig 97016791 Kit pour accrocher 423 Transition 11 4 x 47 a 25 4 cm 4 x 18 2 a 10 po 97014597 Kit de plaque de ventilateur ENSEMBLE DE Commander les pi ces de rechange par num ro de r f rence et non a l aide du num ro de l gende SOUFFLERIE Visserie standard peut tre achet e localement GARANTIE GO J O O1 BR C ND GARANTIE LIMIT E D UN AN DE BROAN Broan garantit l acheteur consommateur original de ses produits qu ils sont exempts de d fauts dans les mati res premi res ou la main d oeuvre pour une p riode d un an compter de la d
19. e montaje en la posici n deseada 2 9 i Loo i ba zo lt I 54 6 cm gt Abrazaderas de montaje en la Abrazaderas de montaje posici n ajustada en f brica volteadas y montadas a los lados La salida queda paralela a las de la salida del alojamiento viguetas Estructura nueva La salida queda perpendicular a las viguetas Estructura existente q y L e31 1 cm Abrazaderas de montaje montadas en los lados de la salida del alojamiento La salida queda perpendicular a las viguetas Estructura nueva Abrazaderas de montaje volteadas para permitir un espacio adicional de aprox 1 2 54 cm La salida queda paralela a las viguetas Estructura nueva 54 6 cm gt 54 6 cm gt Abrazaderas de montaje Abrazaderas de montaje montadas en la parte superior volteadas y montadas en la de los lados del alojamiento parte superior de los lados del La salida queda paralela a las alojamiento viguetas Estructura nueva o existente La salida queda paralela a las viguetas Estructura nueva o existente MODELO ILB6 P gina 7 OPCIONES PARA LA CONEXI N EL CTRICA COLOCACI N DE LA PLACA DE CONEXIONES CONEXI N VERTICAL DEL CABLE DE ALIMENTACI N HORIZONTAL DEL CABLE DE ALIMENTACI N La placa de conexiones se monta a los lados o en la parte superior del alojamiento OPCIONES PARA LA COLOCACI N DE CONDUCTOS POSICIONES DE LA DESCARG
20. fans must always be vented to the outdoors To reduce the risk of fire use only metal ductwork If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Never place a switch where it can be reached from a tub or shower 10 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings B Always turn hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Pepper corn Beef Flambe C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOW ING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels vio lent steam explosion will result 0 Y 0 WARNING A 4 Use an extinguisher ONL
21. g Outlet parallel to joists New or existing construction MODEL ILB6 Page 3 WIRING OPTIONS WIRING PLATE POSITION E NN l VERTICAL POWER CABLE CONNECTION d HORIZONTAL POWER CABLE CONNECTION Wiring plate mounts to side or top of housing DUCTING OPTIONS BLOWER DISCHARGE POSITIONS DUCT CONNECTOR DUCT CONNECTOR connector positions for right angle discharge Blower and duct connector Blower and duct connector in straight through dis in right angle discharge charge position Factory position shipped DUCTING Right angle blower discharge 42 X 182 TO 10 ROUND TRANSITION Typical ductwork connection to a ventilator converted to right angle discharge MODEL ILB6 BY BROAN USE AND CARE Follow wiring instructions packed with range hood and adhere to all local and state codes and the National Electrical Code Page 4 To clean blower assembly Remove access panel unplug blower from housing remove blower mounting nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge WARNING To reduce the risk of electric shock area and wheel DO NOT ALLOW WATER TO ENTER MOTOR disconnect from power supply before servicing Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor SERVICE PARTS
22. gh discharge position DUCTING Straight through blower discharge 3 7 ROOF CAP 412 X 1812 TO 10 ROUND TRANSITION Ce hh hh LA 10 ROUND ELBOW CL LAN Two ways to connect ductwork to a factory shipped unit BY BROAN WIRING TOP BACK OF HOUSING GROUND TO WIRING PLATE WIRING PLATE 120 VAC LINE IN from range hood Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes MOUNTING OPTIONS 4 20 hex nuts secure mounting brackets to housing Loosen and re tighten or remove and replace nuts as necessary for desired mounting bracket position yoo gu A 0 0 A lu 21 9 I Mounting brackets in factory shipped position Outlet parallel to joists New construction Mounting brackets flipped over and mounted to outlet sides of housing Outlet parallel to joists Existing construction 11 2 ooo i 5 0 I 21 gt Mounting brackets flipped over to give approx 1 more clearance Outlet parallel to joists New construction le 12 9 Mounting brackets mounted to outlet sides of housing Outlet perpendicular to joists New construction 91 2 to 10 3 4 to 113A ET E 21 Mounting brackets mounted to top of sides of housing Outlet parallel to joists New or existing construction Mounting brackets flipped over and mounted to top of sides of housin
23. i n de una garant a impl cita por lo que esta limitaci n tal vez no se aplica al caso suyo LA OBLIGACION DE BROAN DE REPARAR O CAMBIAR A OPCION DE BROAN SERA EL UNICO Y EXCLUSIVO REMEDIO AL COMPRADOR BAJO ESTA GARANTIA BROAN NO SERA RESPONSABLE POR DANOS INCIDENTALES CONSECUENTES O ESPECIALES QUE SURJAN DE O EN RELACION A EL USO O DESEMPENO DEL PRODUCTO Algunos estados no permiten la exlusi n o limitaci n de da os incidentales o consecuentes por lo que esta limitaci n o exclusi n tal vez no se aplica en su caso Esta garant a le da derechos legales espec ficos y usted puede tener otros derechos que var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para calificar para servicio bajo esta garant a usted debe a notificar a Broan en la direcci n que aparece abajo o al tel fono 1 800 637 1453 b dar el n mero de modelo y la identificaci n de pieza y c describir el defecto en el producto o pieza Al solicitar servicio bajo la garant a usted debe presentar evidencia de la fecha de compra original En los Estados Unidos llame Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 En Canada llame Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario L5T 1H9 905 670 2500 99043701B BY BROAN VENTILATEUR MONTAGE DANS LIGNE LIRE ET CONSERVER CES INSTRUCTIONS MODELE ILB6 Page 9 A POUR USAGE DOMESTIQUE SEULEMENT A AVERTISSEMENT A POU
24. la unidad de potencia lejos de roc os de yeso polvo de construcci n etc 3 Si el ventilador se instala en un rea sin acondicionamiento como por ejemplo en un tico Rodee el ventilador con material de aislamiento t rmico para minimizar la posible condensaci n 4 Para m s informaci n y requisitos favor leer la etiqueta de especificaciones del producto CONTENDIO Este manual consiste en las siguientes secciones INSTALACI N T PICA Esta secci n muestra una instalaci n com n en una estructura nueva y en una existente Montaje estructura nueva Montaje estructura existente Montaje el usar kit de suspender Conexiones el ctricas Colocaci n de conductos descarga derecho por del ventilador OPCIONES DE MONTAJE OPCIONES PARA LA CONEXI N EL CTRICA Colocaci n de la placa de conexiones OPCIONES PARA LA COLOCACI N DE CONDUCTOS Posiciones de la descarga del ventilador Colocaci n de conductos descarga ngulo recto del ventilador USO Y CUIDADO PIEZAS DE SERVICIO GARANT A Instalador Deje este manual con el due o de casa Due o de casa Informaci n del uso y mantenimiento en la p gina 8 BY BROAN INSTALACION TIPICA MONTAJE Estructura nueva CONDUCTO REDONDO DE 25 4 cm 10 po Abrazaderas de montaje enviadas de fabrica en posici n para montarse en una vigueta de 1 2 1 27 cm del techo TRANSICI N 11 4 X 47 a254 cm
25. m the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan faulty installation or installation contrary to recommended installation instructions The duration of an implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN S OBLIGATION TO REPAIR OR REPLACE AT BROAN S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WAR RANTY BROAN SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This
26. n conditionn tel qu un grenier Entourez le ventilateur d un isolant thermique afin de r duire toute condensation ventuelle 4 Veuillez lire l tiquette de sp cifications sur le produit pour d autres renseignements et exigences TABLE DES MATI RES Ce manuel se divise comme suit INSTALLATION TYPIQUE Cette section montre une installation standard dans un b timent en cours de construction ou d j construit Montage construction en cours Montage construction termin e Montage kit pour accrocher Installation des conduits d charge de soufflerie dans ligne C blage OPTIONS DE MONTAGE e OPTIONS DE C BLAGE Position de la plaque de c blage OPTIONS D INSTALLATION DES CONDUITS Positions de la d charge de la soufflerie Installation des conduits d charge de soufflerie droit angle UTILISATION ET ENTRETIEN PIECES DE RECHANGE GARANTIE Installateur Remetez ce manuel au protpri taire de maison Propri taire de maison Mode d utilisation et soin la page 12 Let BY BROAN INSTALLATION TYPIQUE MONTAGE Construction en cours CONDUIT CIRCULAIRE DE 10 po 25 4 cm TRANSITION 42 X 18 au 10 po 11 4 x 47 au 25 4 cm circulaire Supports pr assembl s pour plafonds de Ye po 1 27 cm d paisseur SOLIVE DE PLAFOND 24 po 61 cm centre CONDUIT CIRCULAIRE Soufflerie pr assembl e DE 10 po 25 4 cm en position de d charge horizontale TRANSITION
27. ndommager les fils lectriques et les autres utilit s dissimul es 6 La d charge des ventilateurs conduit par l vent doit toujours se faire l ext rieur 7 Pour r duire le rsque d incendie utilisez seulement des donduits de ventila tion en m tal 8 Si cette unit doit tre install e au dessus d une baignoire ou d une douche elle doit tre marqu e comme tant appropri e pour l application et tre connect e un circuit d riv prot ge GFCI interrupteur de circuit en cas de d faut de mise la terre du neutre 9 Ne placez jamais un interrupteur dans un endroit o il peut tre rejoint d une baignoire ou d une douche 10 Cette unit doit tre mise la terre AFIN DE DIMINUER LES RISQUES D INCENDIE POUVANT SE DECLENCHER SUR LA SURFACE DE CUISSON 1 Ne jamais laisser sans surveillance des unit s de surface r gl es feu vif En plus de g n rer de la fum e les d bordements de graisse peuvent prendre feu Chauffer les huiles lentement feu doux ou moyen 2 Toujours mettre en marche la hotte durant la cuisson feu vif ou la cuisson d aliments flamber 3 Nettoyer r guli rement les ventilateurs d a ration On ne doit tol rer aucune accumulation de graisse sur le ventilateur ou sur le filtre 4 Utiliser une casserole de grosseur appropri e Toujours utiliser une batterie de cuisine proportionnelle l l ment de surface AFIN DE DIMINUER LES RISQUES DE BLESSURES POUVANT SURVENIR
28. onstrucci n a prueba de incendios 4 Se necesita suficiente aire para la combusti n y extracci n de gases por la chimenea del equipo que quema combustible para evitar la retrogresi n de las llamas Siga las directrices del fabricante y est ndares de seguridad como los publicados por la Asociaci n Nacional de Protecci n Contra Incendios o por sus siglas en ingl s NFPA y la Sociedad Americana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado o por sus sigles en ingl s ASHRAE y los c digos de las autoridades locales 5 Cuando corte o taladre en una pared o cielo raso no da e cableado el ctrico o instalaciones no visibles 6 Ventiladores con conductos siempre deben extraer hacia el exterior 7 Para reducir el riesgo de incendio use s lo ductos de metal 8 Si esta unidad va a instalarse sobre una ba era o ducha debe marc rsela como correcta para dicha aplicaci n y debe conectarse a un protegido GFCI Cortacicuito Accidental a Tierra 9 Nunca instale un interruptor donde se pueda alcanzar desde una ba era o ducha 10 Esta unidad se debe conectar a tierra PARA REDUCIR EL RIESGO DE INCENDIO DEBIDO A GRASA ACUMULADA EN LAS HORNILLAS 1 Nunca deje sin atender las unidades de superficie cuando tengan ajustes altos Los reboses pueden provocar humo y derrames grasosos que se pueden incendiar Caliente lentamente el aceite en un ajuste bajo o medio 2 Siempre ENCIENDA la campana cuando cocine con alta
29. os 10 16 x 7 8 se req 4 97016791 Kit de suspender 423 Transici n 11 4 X 47 a 25 4 cm 4 X 1812 a 10 po 97014597 Kit de place del ventilador NL Nac Pida las piezas de repuesto por N DE PIEZA no por N DE CLAVE 24 26 Herraje estandar se puede comprar localmente No demostrado montado GARANTIA LIMITADA DE BROAN DE UN ANO Broan le garantiza al consumidor comprador original de sus productos que tales productos estaran libres de defectos en materiales o mano de obra por un periodo de un a o a partir de la fecha de compra original NO HAY OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR Durante este per odo de un afio Broan reparar o cambiar a su opci n y sin cobro cualquier producto o pieza que se encuentre defectuosa bajo uso y servicio normal ESTA GARANTIA NO SE EXTIENDE A ARRANCADORES DE LAMPARAS FLUORESCENTES Y TUBOS Esta garant a no cubre a mantenimiento y servicio normales o b cualquier producto o pieza que hayan sido sometidos a uso equivocado negligencia accidente mantenimiento o reparaci n indebida excepto por Broan instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n La duraci n de cualquier garant a impl cita se limita a un per odo de un afio seg n se especifica en la garant a expl cita Algunos estados no permiten limitaci n a la durac
30. warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan at the address or phone number stated below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Best by Broan P O Box 140 Hartford WI 53027 1 800 637 1453 99043701B BY BROAN VENTILADOR PARA MONTAJE EN L NEA lt MODELO ILB6 P gina 5 LEA Y CONSERVE ESTAS INSTRUCCIONES PARA COCINAR EN CASA SOLAMENTE ADVERTENCIA A PARA REDUCIR EL RIESGO DE INCENDIO GOLPE ELECTRICO O LESION A PERSONAS OBSERVE LO SIGUIENTE 1 Use esta unidad solamente de la manera indicada por el fabricante Si tiene preguntas p ngase en contacto con el fabricante a la direcci n o tel fono que aparecen en la garant a 2 Antes de limpiar o de poner en servicio la unidad apague el interruptor en el panel de servicio y asegure el panel de servicio para evitar que se encienda accidentalmente Cuando el dispositivo para desconectar el servicio el ctrico no puede ser cerrado con alg n tipo de traba sujete fuertemente al panel de servicio una etiqueta de advertencia prominente 3 Eltrabajo de instalaci n y cableado el ctrico deben estar hechos por personal capacitado de acuerdo con todos los c digos y est ndares aplicables incluyendo c digos y est ndares de c
Download Pdf Manuals
Related Search
Related Contents
2014 Boston National College Fair Exhibitor Service Manual VERTEX VD 26 SERIES USER MANUAL Inbetriebnahme Servodyn-GC16 Bedienungsanleitung Beats by Dr. Dre Mixr r`s Manua| Covering Model ARTSC8651 Tripp Lite USB 3.0 SuperSpeed Device Cable (AB M/M), 6-ft 18 VOLT SAWZALL PASSE-PARTOUT SAWZALL 18 V SIERRAS 2 - Industry Support Siemens Manual Port Copyright © All rights reserved.