        Lux Products 3M-22 Thermostat User Manual
         Contents
1.    Install guide 3M 22    Filtrete 3M            Your thermostat is a precise instrument  handle it with care     Turn off electricity to the appliance before installing or  servicing thermostat or any part of the system      Do not turn electricity back on until work is completed      Do not short  jumper  across electric terminals at control on  furnace or air conditioner to test the system  This will damage  the thermostat and void your warranty      All wiring must conform to local codes and ordinances      This thermostat is designed for use with 24 volt AC and  millivolt systems  The thermostat should be limited to a  maximum of 1 0 amps  higher amperage may cause damage          to the thermostat  J       Filtrete                         ENGLISH    Install guide 3M 22 Filtrete 3M    m To avoid electrical shock and to prevent damage to the furnace  air conditioner   Caution and thermostat  disconnect the power supply before beginning work     This can be done at the circuit breaker  or at the appliance               You will need a small Phillips screwdriver and possibly a drill    with 3 16 in   4 8mm  bit for wall mounting     Replacement installations   mount the new thermostat in place of the old one     New installations   follow the guidelines listed below     Locate the thermostat on an inside wall  about 5 ft   1 5m  above the floor  and  in a room that is used often  PG 1      Do not install it where there are unusual heating conditions  such as  in direct  sun
2.    Set Config jumpers per this diagram        3M 22 Features PG 23    This thermostat can be used with all millivolt and 24VAC heating and cooling systems  It  cannot be used with line voltage systems  This thermostat is digital and your desired heat or  cool temperatures can easily be set on the large screen with the     buttons on the front  A  minimum 4 minute off time protects heating and cooling systems from damage    This thermostat uses a new technique called sequential staging for more comfort with  faster reaction to requested temperature changes  When using a heat pump with Aux heat  if  the heat pump cannot keep up and or is  defective  remove jumper from position 8 and put  jumper on position 6 and the Aux heat will then  be your only source of heat  Be sure to restore it  to PUMP when the pump is again operational as  aux heat is more expensive than pump heat                    Your Wires Filtrete Terminal   RorV or VR  RH and RC Single power for HEAT and COOL   RH or 4 RH Power for HEAT  RH not connected to RC   RC RC Power for COOL  RH not connected to RC    W W Heat control   W2 W2 2nd stage HEAT or heat pump auxiliary heat     A 3rd wire for zoned hot water heat  see zoned  B and O   Y Y COOL control NOTE  i   Y2 Y2 2nd stage COOL control     GorF G FAN control thers are both  CorX C Common 24VAC power  to power thermostat  T ee  E Emergency heat  do not connect  tape off    oduct   L System monitor  do not connect  tape off  Bo NOT   T Outdoor sensor  do not
3.    To check COOL mode      Set the mode switch to COOL      Press the TEMP   button to a temp 5 degrees below the room temp   Allow the system 2 minutes to respond      Verify that cool air is blowing from the system     Congratulations  you have successfully installed your unit   Please proceed to the OPERATING Guide to initialize the 3M 22     NOTE  If you have labeled your wires  follow the correct Step By Step  and  these Check procedures do not operate your system call support at    1 888 607 5824 PG 12    PG 13    Power Options    BATTERIES ONLY   This thermostat can run on batteries only using 2AAA  alkaline batteries  The batteries will last at least 1 year  replace the batteries  once a year or when the low battery icon comes on the display  If the batteries  are not replaced  the thermostat will shut off the HVAC and then stop working     24VAC   This thermostat can run on the HVAC 24VAC  C wire  if available   As shown in the wiring diagrams  the C wire is the other side of the 24VAC  heating transformer and can be found where the other thermostat wires  connect at the wall or at the furnace  Do not use the common or ground side  of the line voltage  If the C wire is used  the batteries are then for back up in  case of power loss only and will last much longer  With the C wire connected   the thermostat will continue to work if the batteries die or are removed     Calibration    NOTE  Your thermostat comes from the factory calibrated to     1  of actual  temperatur
4.  Connect the G wire to G on the 3M 22  123 ggg  STEP 6   Set Config jumpers per this diagram   Set jumper 1 if you have Gas or Oil aux heat        Your HVAC system is now connected  to the 3M 22     f Please Go To Page 9    3M 22  Terminals    4  C W2 W Y Y2 RH RC G  2 Stage Heat and Cool PG 21    STEP 1   Connect the W wire to the W terminal and W2 to   W2 on the 3M 22  This connects 2 stages of heat    STEP 2   Connect the Y wire to the Y terminal and Y2 wire   to Y2 on the 3M 22  This connects 2 stages of cool    STEP 3   Connect the RH or R wire to the RH terminal on senile  the thermostat  This connects the Heater Cooler Power  E   E  E  6E  E37 or  STEP 4   Connect the G wire to the G terminal on the 123 gry  Thermostat  This connects to the Fan    STEP 5   Set Config jumpers per this diagram  If you  have Electric heat set 5  if you have Gas or Oil set 7   Your HVAC system is now connected  to the 3M 22     POWER       Please Go To Page 9 OOOOOOQ QO  4021 CBOW WYY2RHRCGA        4 W RH  A   3 Zoned Hot Water   Motor Valve PG 22  Step 1   based on your valve type SET JUMPERS    Motor driven Valve  Connect the R  or RH  wire to the RH  terminal on the 3M 22  Connect the W wire to the W terminal        E     on the 3M 22  Connect the remaining wire to the A terminal  123  Solenoid valve  Connect the R  or RH  wire to the RH 4 3 E35  terminal on the 3M 22  Connect the W wire to the A terminal 60 EH 7  on the 3M 22  Connect the remaining wire to the W 8l  terminal     STEP 2
5.  connect  tape off  CONNECT B  Bor B Heat pump changeover  cool to heat  powered in heat  to B terminal   O O Heat pump changeover  heat to cool  powered in cool  CREE  9   B and O SEE NOTE ermina    Wire Reference cont    Your Wires Filtrete Terminal  Lennox Heat Pump   V or VRorR HH   M or Y Y   Y or W or W2 W2   ForG G   RorO O   XorX20r C C    Trane Products  American Standard   B    W or W1 W2          Zoned Systems    Your Wires    Ww WwW    3 Wire Zoned Hot Water    Motor Driven Valves  R RH    Ww Ww  Y  the 3rd wire  A    3 Wire Zoned Hot Water    Solenoig Valves    W A  Y  the 3rd wire  W    Jumper Reference RESET UNIT  AFTER CHANGING JUMPERS  r   5 CLOSED OPEN  Configuration jumpers allow your  SINGLE  3M 22 to be adapted to many _ HVAC   POWERIR  w m POWER RH  different HVAC control applications  4 POWERRC  NORM PUMP AUX  AUX 12hrclock CELSIUS SELECT  TYPE 24hr clock FAHRENHEIT  CLOSED HEAT PUMP S CLOSED m m OPEN  PUMP AUX AUX ONLY 6  GasoRoi Ahr CELSIUS      m HEAT    1 a 2 2  PUMP CLOSED m m OPEN  PUMP AUX 12hr FAHRENHEIT j  ELECT  OPEN                               Filtrete             Customer Support  888 607 5824 or  Visit our website www radiothermostat com filtrete    Printed in China    PG 25    Filtrete Terminal  2 wire Zoned Hot Water  R RH    PG 26    GAS ELEC HEAT  SELECT          ELECTRIC  OR PUMP  CLOSED    GAS OR OIL    HEAT  CLOSED          1002 005    
6. This may  require you to find the  other end  connection for each wire on your heating or  air conditioning equipment and read the label there    If you have a wire marked  C  it is optional  If you do connect it  the  thermostat will draw power from the C wire  This extends battery life  Pa 6                                     Find the set up diagram for your system Pa 7    C W RH   Find the referenece page with your wiring   From a Ul diagram and jumper set up information    pum Remember  the C wire is optional           ACW RH GEC W Y RH G HC W Y RHRCG  cf LW  Ra From     3Wire   FO    4Wire From 5 Wire    Furnace    Furnace            Heat Cool Heat Cool    W RHA    From 3 Wire  Fuma  Zoned    Hot Water       c  Ww   ral E    wy  RH NL  Go To Page 16 Go To Page 17 Go To Page 18          z z z  HC B or O  Y RH G  amp  C Bor O  W2 Y RH G BC W2 W Y Y2 RH G  Froe 4 Wire Heat Pump  Fome  5Wire race 2 stage Cool         w o Aux Heat Heat Pump    2 stage Heat  w  Aux Heat    or or  Go To Page 19 Go To Page 20 Go To Page 21       f you combination of wires is not above you can use the  wiring table on pages 24 25 to determine your connections   or call our USA support line at 1 888 607 5824 for help  PG 8      Mountthe 3M 22 0 Wall      Hold the 3M 22 against the wall  with the wires coming 3M 22  over the top above terminal block  The 3M 22 will cover the  hole in the wall     Position 3M 22 for best appearance  Use the optional stand   offs if more space for wires is needed be
7. e  It is an accurate instrument  If you want your thermostat to  display the same temperature as another thermometer in your home  you  can adjust its calibration    To change the calibration    Set the Mode switch to HEAT or COOL   Locate the TIME SET button and press it  The HOME  current calibration factor       of the 3M 22 will appea C P S  in the LCD display as well as the modified temp  EAD     WES  Push the UP or DOWN arrows until the desired eC  jm  calibration factor is reached     Press HOME to save  The new calibrated temperature  will be displayed on the LCD  PG 14           Calibrate button    HC W RH  2WIRE HEAT Heating GAS MILLIVOLT or 24vac Pa 15    STEP 1   Connect the R  or RH  wire to the RH terminal on   the 3M 22  This connects the Heater Power to the thermostat    STEP 2   Connect the W wire to the W on the 3M 22  HOE me  15  This connects the heater control line to the 3M 22  123   EJ  STEP 3   Set Config jumpers per this diagram  SET JUMPERS        Your Heater is now connected to the 3M 22   Please Go To Page 9    3M 22  NOTE  Wires marked with   OOO W OOOO O  dotted line are optional    C B O W2 W Y Yo RHRC GA    jj CW RH G  3 Wire Heat pa 16  STEP 1   Connect the R  or RH  wire to the RH terminal  on the 3M 22  This connects to the Heater Power      OPTIONAL POWER    STEP 2   Connect the W wire to the W terminal on the E   3E  Mis    gt  of  3M 22  This connects the heater control line to the 123 gr    3M 22    STEP 3   Connect the G wire to the G t
8. erminal on the  thermostat  This connects the Fan to the 3M 22  STEP 4   Set Config jumpers per this diagram  If you    have Electric heat set 5  if you have Gas or Oil set 7   OPTIONAL POWER    SET JUMPERS       Your system is now connected to the 3M 22   Please Go To Page 9 OOOO    jc WYRHG  A4Wire Heat Cool Pa 17  STEP 1   Connect the W wire to the W terminal on the SET JUMPERS    thermostat  This connects to the heater control line  a   1   4 E15  STEP 2   Connect the Y wire to the Y terminal on the EGE 6   E37 9   3M 22  This connects to the Cooler compressor  123 gr    STEP 3   Connect the RH or R wire to the RH terminal on  the thermostat  This connects the Heater Cooler Power   STEP 4   Connect the G wire to the G terminal on the  Thermostat  This connects to the Fan   STEP 5   Set Config jumpers per this diagram  If you  have Electric heat set 5  if you have Gas or Oil set 7   Your HVAC system is now connected            to the 3M 22    lt  Please Go To Page 9 OOOOOQ    2 C B O W2 W    Terminals    dC WYRHRCG 5 Wire Heat Cool Pa 18    STEP 1   Connect the W wire to the W terminal on the   thermostat  This connects to the heater control line  SET JUMPERS    STEP 2   Connect the Y wire to the Y terminal on the E     E  4E     or  3M 22  This connects to the Cooler compressor  123 gr s  STEP 3   Connect the RH wire to the RH terminal and the  RC wire to the RC terminal on the 3M 22  This connects  the Heater and Cooler Power    STEP 4   Connect the G wire to the G termi
9. hind the 3M 22  Wires    Attach the base to the wall with the screws provided       f you are mounting the base to sheet rock or if you are using  the old mounting holes  use the plastic anchors provided  Drill     a 3 16 in   4 8mm  hole for the insert at  om     each screw location  then mount the base                          Wall anchor       Pa 9    Install AAA Batteries      The 3M 22 requires 2 AAA batteries to operate     e Switch MODE switch to OFF and the FAN switch to AUTO      Install 2 AAA alkaline batteries according to the polarity noted in  the compartment  LCD segments will go on    e Press the RESET button  under top cover  to clear transient  program memory  NOTE  Replace the batteries when this LOW  battery indicator appears on the display or once a year      Replace top and bottom covers on unit  j                   PG 10    11  Check Unit is    Temperature  TEMP Display Mode    have correctly installed the 3M 22  UP button SUCH  To check Fan   If you connected the  G wire   fan relay    Hear     Switch the FAN switch to the ON Fr E  position  Verify that air is blowing from ME MT    the system  Return to AUTO position    for normal operation     Follow these procedures to verify you                               To check HEAT mode  Mon  Set the mode switch to HEAT  TEMP  Set the fan switch to AUTO  DOWN button      Using the TEMP   button raise the Target Temp to 90deg    Allow the system 2 min to respond      Verify that heat is blowing from the system 
10. light  near a lamp  radio  television  radiator register  or fireplace  near hot  water pipes in a wall  near a stove on the other side of a wall      Do not locate in unusual cooling conditions  such as  on a wall separating an  unheated room  or in a draft from a stairwell  door  or window      Do not locate in a damp area  This can  lead to corrosion that will shorten thermostat  life      Do not locate where air circulation is poor   Such as  in a corner or an alcove  or behind  an open door      Do not install the unit until all construction  work and painting has been completed      This thermostat does not require leveling           IMPORTANT   LABEL ALL WIRES      Switch electricity to the furnace and BEFORE DISCONNECTING THEM     air conditioner OFF  then proceed with the  following steps     Remove cover from old thermostat  Most are  snap on types and simply pull off  Some have  locking screws on the side or front  These must S    be loosened  Note the letters printed near the terminals  Attach  labels  enclosed  to each wire for identification   C z Read instructions carefully before removing any wiring from eun thermostat     Caution   Wires must be labeled before they are removed  THERE IS NO STANDARD  COLOR CODE  When removing wires rom ihel terminals  ignore the color of          the wires since these may not comply wi    PG 3      Label the wires one at a time  You must label all the wires before  you proceed  With all wires labeled  remove them from the old 
11. nal on the  Thermostat  This connects to the Fan    STEP 5   Set Config jumpers per this diagram  If you  have Electric heat set 5  if you have Gas or Oil se  Your HVAC system is now connected    to the 3M 22  OQOOOQO  T Please Go To Page 9 22  6 B O W2 W    Terminals             dC BorO YRG 4 Wire Heat Pump w o Aux Pa 19    STEP 1   Connect O wire to the O terminal or B wire to the B terminal on  the 3M 22   If you have both O and B   connect O wire to O terminal  DO NOT connect B to B terminal   see pg 24 Trane for B wire terminal     This connects the change over valve    STEP 2   Connect the Y wire to Y on the 3M 22  SET JUMPERS  This connects the Compressor  BIBIH  4m ms  STEP 3   Connect the R wire to RH on the 3M 22  123 9L L7  This connects to the 24vac power  em    STEP 4   Connect the G wire to the G terminal on the  3M 22  This connects the Fan   STEP 5   Set Config jumpers per this diagram         Your HVAC system is now connected  to the 3M 22  OOOOOO OO  Please Go ToPage9      G BO W2 WY Y2 RH RC G            E     BorO W2Y RHG   5 Wire Heat Pump w  Aux Heat Pa 20    STEP 1   Connect O wire to the O terminal or B wire to the B terminal on  the 3M 22   If you have both O and B  connect O wire to O terminal DO  NOT connect B to B terminal   see pg 24 Trane for B wire terminal   STEP 2   Connect the W2 wire to W2 on the 3M 22  SET JUMPERS  STEP 3   Connect the Y wire to Y on the 3M 22  Am m5  STEP 4   Connect the R wire to RH on the 3M 22     EIEE  6  E37  STEP 5  
12. unit     Make sure the wires do not fall back inside the wall  You can wind  them around a pencil to keep them from falling      Loosen all screws on the old thermostat and remove it from the wall     Fill wall opening with non combustible insulation to prevent drafts     Prepare wires From Wal      You will need at least 2 6  of wire for each  of your connections to the 3M 22       f you do not have enough wire  splice  additional wire to allow enough slack      Fan out wires below the hole as shown                          PG 5  Before you Connect Wires  C   Please follow these guidelines for safe and secure CN   wire connections  YA      Easy Terminals do not require stripping the wire      Clip any bare wire from previous installation      Take care not to damage the labels for each wire in handling      Fan wires out as illustrated with 3M 22 below the wall opening      Wires will dress behind the 3M 22 and up over the terminal area     Use the Step By Step diagram as your guide      Do not bunch wires behind 3M 22  Feed slack back into the wall  opening     Caution Do not allow wires to touch each other or parts on thermostat       Insert the wire in the terminal and tighten foe  the screw securely      You will need to set Configuration  Jumpers per the Step By Step  diagram  A needle nose plier may be  required to modify jumper positions    What wires do you have     Determine which step by step wiring  diagram below you should use  Make  sure your wires are labeled  
    